首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Abstract

The objective of this research was to investigate a sequentially loaded and regenerated granular activated carbon (GAC) biofilter system and to determine whether regenerative ozonation/advanced oxidation could improve the removal and biodegradation of a volatile organic compound from a contaminated airstream. Bench-scale reactors were constructed to operate in a manner analogous to a commercially available system manufactured by Terr-Aqua Environmental Systems (only with longer contact time). The GAC system consisted of two GAC biofilter beds that operated in a cyclical manner. On a given day, the first GAC bed adsorbed methyl isobutyl ketone from a simulated waste airstream, while the second bed underwent regeneration; then on the next day, the second bed was in the adsorption mode while the first was regenerated.

Three bench-scale systems were used to compare the performance under three operating conditions: (1) ozone/ associated oxidant regeneration of a GAC biofilter system that was seeded with microorganisms from a field site, (2) a humid air regeneration of a seeded GAC biofilter, and (3) a humid air regeneration of an unseeded GAC biofilter. For the advanced oxidant regenerated GAC biofilter, a maximum removal efficiency of >95% was achieved with an empty bed contact time of 148 sec and an influent concentration of 125 ppm methyl isobutyl ketone, and 90–95% was achieved at 148-sec empty bed contact time and a 1150-ppm influent.  相似文献   

2.
There seems to be a general impression on the part of the public and many technical people that dust collecting systems on the open hearth furnace are simply a matter of giving a contract for a duplicate system to that previously installed; signing a check for a sum to cover the cost of the cleaning equipment itself, pressing the start-up button and then sitting back to receive the plaudits of a grateful community. This paper will briefly present some of the problems common to all of the installations to date. It will also explain why the cost of the cleaning equipment itself is such a small portion of the total cost.  相似文献   

3.
The future for electrocoagulation as a localised water treatment technology   总被引:1,自引:0,他引:1  
Electrocoagulation is an electrochemical method of treating polluted water whereby sacrificial anodes corrode to release active coagulant precursors (usually aluminium or iron cations) into solution. Accompanying electrolytic reactions evolve gas (usually as hydrogen bubbles) at the cathode. Electrocoagulation has a long history as a water treatment technology having been employed to remove a wide range of pollutants. However electrocoagulation has never become accepted as a 'mainstream' water treatment technology. The lack of a systematic approach to electrocoagulation reactor design/operation and the issue of electrode reliability (particularly passivation of the electrodes over time) have limited its implementation. However recent technical improvements combined with a growing need for small-scale decentralised water treatment facilities have led to a re-evaluation of electrocoagulation. Starting with a review of electrocoagulation reactor design/operation, this article examines and identifies a conceptual framework for electrocoagulation that focuses on the interactions between electrochemistry, coagulation and flotation. In addition detailed experimental data are provided from a batch reactor system removing suspended solids together with a mathematical analysis based on the 'white water' model for the dissolved air flotation process. Current density is identified as the key operational parameter influencing which pollutant removal mechanism dominates. The conclusion is drawn that electrocoagulation has a future as a decentralised water treatment technology. A conceptual framework is presented for future research directed towards a more mechanistic understanding of the process.  相似文献   

4.
Regional haze regulations require progress toward reducing atmospheric haze as measured by particle scattering coefficient of visible light. From a practical perspective, this raises the following question: Given a decrease in extinction, what is the probability that people will notice an improvement in visibility? This paper proposes a quantitative definition of the probability of a perceptible increase in visibility given a decrease in light extinction and a general method to estimate this probability from perception measurements made in the field under realistic conditions. Using data from a recent study of visibility perception by 8 observers, it is estimated that a 2-4 deciview change gives a 67% maximum probability of detecting the improvement. Stated another way, the odds of seeing a difference are at most 2:1 for a change of 2-4 deciviews. A 90% probability requires a change of at least 3.5-7.0 deciviews. The limitations and possible bias in the results of this study are discussed. These results may have a major effect on the cost-benefit analysis of regulatory actions to improve visibility.  相似文献   

5.
Mercury (Hg) contamination in piscivorous birds, especially methylmercury (MeHg), has been drawing much attention worldwide in regard to its bioaccumulation and biomagnification in food chains. In this study on Hg in the soft tissues of white-tailed eagles (n = 22) and ospreys (n = 2) from Poland, total Hg (THg) range was 0.15–47.6 while MeHg range was 0.11–8.05 mg kg−1 dry weight. In both species, median THg and MeHg concentrations were lower in the muscle and brain than in the liver and kidney. Median nephric residues were just under 3 and 5 mgTHg kg−1 or 0.9 and 3.7 mgMeHg kg−1 for white-tailed eagle and osprey, respectively. In Norwegian data from the 1970s and in our results, MeHg in the muscle of white-tailed eagle was ~60 % THg (%MeHg = MeHg/THg × 100), lower than in other piscivorous birds. A clear similarity in THg tissue levels was found between Polish and German populations of white-tailed eagles.  相似文献   

6.
This paper develops a simple model and suggests a plausible chemico-physical mechanism for a non-linear response between atmospheric sulphur and sulphur emissions. It contains simplified representations of transport, deposition and conversion processes and uses a proxy in-cloud oxidant-limited reaction along a pathway connecting an emission source with a receptor site. Individual pathway responses to emissions show linear behaviour above a threshold. However, by averaging the values of SO2 at the receptor site from different pathways a continuous non-linear relationship is obtained. As emissions reduce, distant emission sources become less significant contributors of sulphur dioxide at a receptor site but their emissions are still counted in an emission inventory, leading to an apparent non-linearity. Sulphate is always found to contribute a signal to the receptor site total. This model goes someway to explaining a proposed 'crossover' between observed proportions of wet and dry deposited sulphur in the UK as emissions have been reduced.  相似文献   

7.
A rapid spectrophotometric determination of persulfate anion in ISCO   总被引:10,自引:0,他引:10  
Due to a gradual increase in the use of persulfate as an in situ chemical oxidation (ISCO) oxidant, a simple measurement of persulfate concentration is desirable to analyze persulfate distribution at designated time intervals on/off a site. Such a distribution helps evaluate efficacy of ISCO treatment at a site. This work proposes a spectrophotometric determination of persulfate based on modification of the iodometric titration method. The analysis of absorption spectra of a yellow color solution resulting from the reaction of persulfate and iodide in the presence of sodium bicarbonate reveals an absorbance at 352 nm, without significant interferences from the reagent matrix. The calibration graph was linear in the range of persulfate solution concentration of 0-70 mM at 352 nm. The proposed method is validated by the iodometric titration method. The solution pH was at near neutral and the presence of iron activator does not interfere with the absorption measurement. Also, analysis of persulfate in a groundwater sample using the proposed method indicates a good agreement with measurements by the titration method. This proposed spectrophotometric quantification of persulfate provides a simple and rapid method for evaluation of ISCO effectiveness at a remediation site.  相似文献   

8.
The objective of this research was to investigate a sequentially loaded and regenerated granular activated carbon (GAC) biofilter system and to determine whether regenerative ozonation/advanced oxidation could improve the removal and biodegradation of a volatile organic compound from a contaminated airstream. Bench-scale reactors were constructed to operate in a manner analogous to a commercially available system manufactured by Terr-Aqua Environmental Systems (only with longer contact time). The GAC system consisted of two GAC biofilter beds that operated in a cyclical manner. On a given day, the first GAC bed adsorbed methyl isobutyl ketone from a simulated waste airstream, while the second bed underwent regeneration; then on the next day, the second bed was in the adsorption mode while the first was regenerated. Three bench-scale systems were used to compare the performance under three operating conditions: (1) ozone/ associated oxidant regeneration of a GAC biofilter system that was seeded with microorganisms from a field site, (2) a humid air regeneration of a seeded GAC biofilter, and (3) a humid air regeneration of an unseeded GAC biofilter. For the advanced oxidant regenerated GAC biofilter, a maximum removal efficiency of >95% was achieved with an empty bed contact time of 148 sec and an influent concentration of 125 ppm methyl isobutyl ketone, and 90-95% was achieved at 148-sec empty bed contact time and a 1150-ppm influent.  相似文献   

9.
ABSTRACT

Researchers have applied open path optical sensing techniques to a variety of workplace and environmental monitoring problems. Usually these data are reported in terms of a path-average (or path-integrated) concentration. When assessing potential human exposures along a beam path, this path-average value is not always informative, since concentrations along the path can vary substantially from the beam average. The focus of this research is to arrive at a method for estimating the upper-bound in contaminant concentrations over a fixed open beam path. The approach taken here uses a statistical model to estimate an upper-bound concentration based on a combination of the path-average and a measure of the spatial variability computed from point samples along the beam path. Results of computer simulations and experimental testing in a controlled ventilation chamber indicate that the model produced conservative estimates for the maximum concentration along the beam path. This approach may have many applications for open path monitoring in workplaces or wherever maximum concentrations are a concern.  相似文献   

10.
Loss of filtration efficiency in a fabric filter baghouse is typically caused by bag failure, in one form or another. The degree of such failure can be as minor as a pinhole leak or as major as a fully involved baghouse fire. In some cases, local air pollution regulations or federal hazardous waste laws may require estimation of the total quantity of particulate matter released to the environment as a result of such failures. In this paper, a technique is presented for computing the dust loading in the baghouse exhaust when one or more bags have failed. The algorithm developed is shown to be an improvement over a previously published result, which requires empirical knowledge of the variation in baghouse pressure differential with bag failures. An example calculation is presented for a baghouse equipped with 200 bags. The prediction shows that a small percentage of failed bags can cause a relatively large proportion of the gas flow to bypass the active bags, which, in turn, leads to high outlet dust loading and low overall collection efficiency from the baghouse.  相似文献   

11.
The performance of phillipsite as a matrix for slow-release formulation of oxamyl [N,N-dimethyl-2-methylcarbamoyl-oxymino-2-(methylthio)acetamide] was tested. The adsorption kinetics followed a first-order law, and the adsorption isotherm fitted well in a two-surface Langmuir model, suggesting a double mechanism of interaction between oxamyl and the sorbent. The sorption mechanism, studied by FTIR, provided two fractions of oxamyl. The first one is sorbed on the mineral surface, linked by H-bonding, and the second one is constituted by a multilayer of oxamyl molecules linked by a water bridge between them. The release kinetics of oxamyl from a substratum zeolite-oxamyl also follows a first-order law, with two stages that correspond to both fractions of oxamyl previously detected.  相似文献   

12.
A semianalytical soil-pesticide transport model is formulated based on a compartmental approach to determine spatial and temporal variations of pesticide residues across a soil profile. The compartmental model is implemented by drawing an analogy between a series of continuous-flow stirred tank reactors and a soil horizon that consists of multiple perfectly mixed compartments. The analogy is strengthened by exploiting a relation between the compartment series and the conventional convective-dispersive equation (CDE) for vertical transport in the soil. Consequently, the number of compartments in the model formulation is not free, but dictated as a function of transport parameters. The model formulation allows consideration of arbitrary boundary value specifications and also, for some cases, spatially varying initial concentration profiles. Sorption kinetics is represented via a two-site model that involves a linear sorption isotherm and a first-order irreversible sorption or a radial diffusive penetrating model. For these three cases, analysis of the compartmental model allows the resultant concentration profiles to be expressed in terms of the Poisson distribution. When a nonlinear kinetic sorption model is used to simulate the sorption processes, an analytical solution is not found and a numerical approach is required.  相似文献   

13.
14.
This paper presents results of source size distribution measurements over the size range from 0.1 μm to 5 μm for six classes of particulate sources and fractional efficiency measurements on five full scale electrostatic precipitators and one pilot scale precipitator. The precipitators all showed moderately high to high particulate collection efficiencies for particles having diameters larger than a few micrometers or smaller than a few hundredths of a micrometer and a minimum in collection efficiency for particles having diameters of a few tenths of a micrometer.  相似文献   

15.
The motion of a vertically-projected buoyant jet, in a cross-flow of uniform velocity and uniform stable density-stratification, is investigated by a combination of the ‘integral’ approach with dimensional analysis. For this purpose it is assumed that the distributions of properties such as density deficit over a plane at right angles to the path of the jet remain axisymmetric throughout the motion.The calculations are supported by extensive experimental results obtained by towing an inverted model of a chimney at the surface of a stably-stratified water tank.  相似文献   

16.
This paper focusses on a conceptual overview of ways to address a comprehensive analysis of ecosystem services (ES) in a country as large and heterogeneous as Russia. As a first step, a methodology for assessing the services for the federal subjects of Russia was chosen, i.e., its constituent provinces and similar entities, in physical terms. Russia harbors a great diversity of natural conditions and ecosystems which are suppliers of ES, and likewise a variety of the socio-economic conditions that shape the demand for these services and their consumption. The methodological approach described permits several important tasks to be addressed: the evaluation of the degree of satisfaction of people’s needs for ES, the identification of ecological donor and acceptor regions, and zoning of the country’s territory for ES assessment. The next step is to prepare a prototype of a National Report on ES in Russia, for which we are presenting the planned structure.  相似文献   

17.
Two herbicides, 2,4-D and triclopyr esters (application ratio 1.6:1 acid equivalents) were applied as a tank mix by a crew of 8 backpack sprayer applicators, a mixer/loader, and a field supervisor. The crew was employed in a conifer release program in northern California during the summer of 2002. Biomonitoring (urine, 24 h) utilized 2,4-D and triclopyr (a.e.) as rapidly excreted exposure biomarkers. The absorbed dosages of 2,4-D and triclopyr were calculated based upon cotton whole body suits and biomonitoring. Dosages based upon accumulation of the herbicides on body suits averaged 42.6 μg (a.e.) 2,4-D/kg-d and 8.0 μg (a.e.) triclopyr/kg-d. Six consecutive days of concurrent urine collections showed that backpack applicators excreted an average of 11.0 μg (a.e.) 2,4-D/kg-d and 18.9 μg (a.e.) triclopyr/kg-d. Estimates based upon curve fitting were 17.1 and 29.3 μg (a.e.)/kg-d, respectively. Results suggest that passive dosimetry for 2,4-D consistently overestimated the dosage measured using biomonitoring by a factor of 2-3 fold, while for triclopyr, passive dosimetry underestimated the absorbed dose based on biomonitoring by a factor of 2-4 fold.  相似文献   

18.
The impact of the meteorological situation and chemistry on dry deposition to the southern North Sea is investigated. The studies are performed using a high-resolution meteorology/chemistry model system of different complexity for a five-day period in June 1998. The simulations consider passive tracer transport (Case I), gas phase chemistry (Case II), gas phase plus simple aerosol chemistry (Case III), gas phase plus size dependent aerosol chemistry (Case IV). The results show a very good agreement of meteorology model results with measured data and a reasonable agreement for the concentrations. The dry deposition to the southern North Sea differs a factor of three to seven within the investigated five-day period. Differences are larger for a more complex chemistry. The average dry deposition increases by a factor of three when including gas phase reactions or adding a simple aerosol model and up to a factor of eleven when considering a sectional aerosol model. The input composition depends on the chemistry considered.  相似文献   

19.
Researchers have applied open path optical sensing techniques to a variety of workplace and environmental monitoring problems. Usually these data are reported in terms of a path-average (or path-integrated) concentration. When assessing potential human exposures along a beam path, this path-average value is not always informative, since concentrations along the path can vary substantially from the beam average. The focus of this research is to arrive at a method for estimating the upper-bound in contaminant concentrations over a fixed open beam path. The approach taken here uses a statistical model to estimate an upper-bound concentration based on a combination of the path-average and a measure of the spatial variability computed from point samples along the beam path. Results of computer simulations and experimental testing in a controlled ventilation chamber indicate that the model produced conservative estimates for the maximum concentration along the beam path. This approach may have many applications for open path monitoring in workplaces or wherever maximum concentrations are a concern.  相似文献   

20.
Lee BD  Hosomi M 《Chemosphere》2001,43(8):1127-1132
In order to mitigate the strong microbial resistance of benz(a)anthracene [B(a)A] in soil, a hybrid treatment of Fenton oxidation followed microbial culture was carried out. Based on optimal Fenton oxidation, i.e., 1.0 ml of ethanol, 0.2 ml of 0.5 M Fe2+, and 0.3 ml of 30% H2O2 per 1 g of 500 mg B(a)A/kg soil, about 43% of B(a)A-7,12-dione was generated during oxidation of 97% B(a)A. When the comparative biodegradability between B(a)A-contaminated soil and B(a)A-contaminated soil after Fenton oxidation was examined, it was found that 98% of B(a)A-7,12-dione degraded after 63 d in comparison with only 12% of B(a)A over the same period; results demonstrating that Fenton oxidation enhances biodegradability of B(a)A through B(a)A-7,12-dione.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号