首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
Experience with prenatal karyotyping of 237 fetuses with sonographic evidence of malformation is reported. Abnormal karyotype was found in 40 cases (16-8 per cent): chromosomal aberrations were found in 19 of the 178 fetuses with an isolated structural anomaly (10-6 per cent) and in 21 of the 59 fetuses with multiple malformations (35-6 per cent). Detailed cytogenetic and morphological information concerning fetuses affected by omphalocele, duodenal atresia, hydrocephalus, multicystic kidney, unilateral hydronephrosis and cystic hygroma is reported. The need for a very careful ultrasound evaluation of fetal anatomy in these pregnancies is stressed, as the risk of a chromosomal anomaly depends mainly on the existence of more than one ultrasonically diagnosed structural defect.  相似文献   

3.
4.
5.
6.
The aim of the study was to assess the value of sonographic measurement of fetal humerus and femur lengths in the second trimester as a screening tool for Down syndrome (DS). We reviewed retrospectively fetal sonographic biometry made at the time of amniocentesis between 15 and 19 weeks. The study group consisted of 27 DS fetuses. The control group comprised 500 normal fetuses chosen randomly. The expected humeral and femoral lengths for a given biparietal diameter were estimated by linear regression equations from the 500 normal fetuses. Receiver operating characteristic curve analysis was performed to evaluate both the detection rate and the false-positive rate of different cut-off values of measured to expected lengths ratios. The median femur and humeral lengths in DS fetuses were 0·91 times the expected values. No significant differences in the detection rate and false-positive rate were found between the humerus and femur lengths. When the humeral and femoral lengths were combined, we observed a remarkable reduction in the false-positive rate. A measured to expected length ratio of 0·91 detected 44·4 per cent of DS fetuses with 7·6 per cent false positives. These results suggest that the combination of femoral and humeral lengths may permit a more efficient use of ultrasound in screening for Down syndrome than the use of either alone.  相似文献   

7.
8.
9.
10.
11.
12.
Flow cytometry was used to measure neutrophil and monocyte β2-integrin expression in fetuses with trisomy 18 (n=7) and trisomy 21 (n=7) at 20–25 weeks' gestation. The values were compared with those of 112 chromosomally normal fetuses. There were no significant differences in β2-integrin expression between normal and aneuploid fetuses. These findings demonstrate that in trisomies 21 and 18, alteration in β2-integrin expression is unlikely to contribute to the pathogenesis of immunological deficiencies that have been observed in these aneuploidies both prenatally and postnatally.  相似文献   

13.
14.
Structural pathology and outcome were studied in 170 chromosomally abnormal fetuses. Numerical chromosomal abnormalities were established in 158 (93 per cent) cases, of which 110 (71 per cent) represented trisomies, 30 (18 per cent) Turner syndrome, and 18 (11 per cent) triploidy. Structural chromosomal abnormalities were diagnosed in 12 (7 per cent) cases. Gestational age at referral was significantly shorter for pregnancies with Turner syndrome than for the other chromosomal abnormalities. Referral before 20 weeks of gestation was mainly based on fetal structural pathology alone (92 per cent); after 20 weeks, patients were referred because of structural pathology combined with small for gestational age, oligohydramnios, or polyhydramnios. Referral as a result of suspected multiple organ pathology occurred in 73.5 per cent of pregnancies. An abnormal amniotic fluid volume was present in 59/170 (34.5 per cent) chromosomally affected pregnancies, i.e., oligohydramnios in 31 and polyhydramnios in 28 cases. Birth weight was below the tenth percentile in over half of the chromosomally abnormal fetuses, except for Turnersyndrome. Fetal outcome was poor, with a survival rate at 1 month of 30 per cent for trisomies which was mainly determined by trisomy 21 (14/18=77.5 per cent).  相似文献   

15.
16.
Flow cytometry was used to enumerate the lymphocyte subpopulations in fetal blood obtained by cordocentesis from eight trisomy 18 fetuses at 20–36 weeks' gestation. Compared with values in chromosomally normal fetuses, in trisomy 18 the mean T- and natural killer (NK) cell counts were significantly lower (t= − 7·63, P<0·001 and t= − 3·58, P<0·01, respectively); the mean B-cell count was not significantly different (t= − 1·32). These findings demonstrate that in trisomy 18 there is abnormal intrauterine development of the immune system.  相似文献   

17.
An evaluation of all fetuses from our institution with prenatally diagnosed cephaloceles was conducted to determine the frequency and spectrum of genetic syndromes associated with this abnormality. Review of the sonographic images, postnatal autopsy or pathology reports, delivery room records, paediatric neurosurgical findings, radiographs, and cytogenetic data were collected. Fifteen postnatally confirmed cases of prenatally diagnosed cephaloceles and two misdiagnosed cases were identified. Thirteen were midline occipital lesions, one was frontoparietal, and one was frontoethmoidal. Excluding microcephaly, hydrocephaly, and distortion of intracranial anatomy, 9 of 15 (60 per cent) had other associated anomalies, including two fetuses with aneuploidy. The prenatal diagnosis of a cephalocele should initiate a thorough search for other abnormalities. In this series, there were three multifactorial, two chromosomal, two sporadic, and two autosomal recessive syndromes identified. An accurate diagnosis is critical in determining the prognosis and providing appropriate genetic counselling.  相似文献   

18.
19.
20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号