首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Simultaneous nitrification and denitrification (SND) effect and phosphor removal were investigated in a one-staged aerobic submerged membrane bioreactor on pilot-scale with mixed liquor suspended solids (MLSS) 19--20 g/L. The effects of DO concentration, sludge floc size distribution on SND were studied. Test results suggested that SND was successfully performed in the membrane bioreactor (MBR) and about 70% total nitrogen removal efficiency was achieved when DO concentration was set to 0.2-- 0.3 mg/L. The main mechanisms governing SND were the suitable sludge floc size and the low DO concentration which was caused by low oxygen transfer rate with such a high MLSS concentration in the MBR. In the meantime, phosphor removal was also studied with polymer ferric sulfate (PFS) addition and 14 mg/L dosage of PFS was proper for the MBR to remove phosphor. PFS addition also benefited the MBR operation owing to its reduction of extracellular polymer substances (EPS) of mixed liquor.  相似文献   

2.
采用有效容积为240 L的中试Carrousel氧化沟处理模拟生活污水,研究了溶解氧对氧化沟同步硝化反硝化脱氮和除磷效果的影响。结果表明:溶解氧的变化对系统中有机物的去除影响不显著;过高或过低的溶解氧均会降低系统总氮和总磷的去除率,溶解氧控制在1.0~1.5 mg/L,系统可获得较高的氨氮和总氮去除率,当溶解氧为1.5 mg/L时,总磷去除率达最高,为71.00%;溶解氧对污泥沉降性能影响显著,低溶解氧运行易引起污泥膨胀。  相似文献   

3.
应用A/O中试装置处理实际生活污水,研究了低DO浓度下系统对有机物、氨氮和总氮的去除效果.研究结果表明,低DO浓度下COD和氨氮的平均去除率分别为85%和92%.由于进水C/N比仅为2.93,总氮平均去除率仅为64%,但提高亚硝酸氮积累率可以提高总氮去除率,当亚硝化率从15%增加到85%,总氮去除率将增加12%.氨氮去除率和硝化速率、总氮去除率具有较好的相关性.维持低DO浓度可以实现亚硝酸型同步硝化反硝化反应,基于氮的物料平衡可知它占系统总氮去除率的5%~12%,增加DO浓度将破坏同步硝化反硝化(SND)现象.  相似文献   

4.
溶解氧对膜生物反应器处理高氨氮废水的影响   总被引:4,自引:0,他引:4  
采用膜生物反应器(MBR)处理高氨氮有机废水,探讨了溶解氧(DO)对有机物、氨氮、总氮等去除效果的影响。当进水COD1500mg/L,NH4+-N150mg/L,TP为15mg/L,pH7.5~8.0,MLSS控制在6000~7000mg/L,DO在0.5~4mg/L时对COD的去除效果没有明显影响,都可高达95%;在DO为4.0和2.0mg/L时对NH4+-N的去除率都很高,最高可达99.17%,在DO为0.5mg/L时明显降低,最低降至48.30%。在DO2.0mg/L时,取得了较好的同步硝化反硝化效果,COD、NH4+-N、TN去除率分别高达97%、97%、68%。MBR中硝化反应的比氨氮消耗速率与氨氮浓度成零级反应动力学,比氨氮硝化速率为0.0979/d,比常规处理系统中的污泥硝化活性高。  相似文献   

5.
氧化沟不同A/O分区对脱氮效果影响的模拟实验研究   总被引:1,自引:0,他引:1  
采用3种不同曝气模式的模拟氧化沟分别形成2、4、7个缺氧-好氧(A/O)分区,研究了3种工况下氧化沟的脱氮方式和脱氮效果.结果表明,在好氧缺氧区体积比例相同的条件下,A/O分区越多,则好氧区平均DO浓度越小,硝化菌活性越低,在2、7个4、A/O分区的3种工况下的硝化菌活性分别为4.80、和3.73mg·g·h4.65-1-1;A/O分区少,则每一分区的缺氧段和好氧段长,进水后反硝化菌利用的有机物就多,在好氧区中的有机物就少,用于硝化的DO量多,从而硝化和脱氮效果好.试验中3种工况的总氮平均去除率分别为60.14%、47.93%、57%,出水总氮平均浓度分别为17.01、22.17和27.92mg·L-1.在氧化沟工艺中,氮的去除途径主要是缺氧反硝化及同步硝化反硝化(SND).分区多,则主要通过同步硝化反硝化脱氮;分区少,则以缺氧反硝化脱氮为主,这是由于碳源限制致使同步硝化反硝化的脱氮效率比缺氧反硝化低.  相似文献   

6.
In the Orbal oxidation ditch,denitrification is primarily accomplished in the outer channel.However,the detailed characteristics of the flow field and dissolved oxygen(DO)distribution in the outer channel are not well understood.Therefore,in this study,the flow velocity and DO concentration in the outer channel of an Orbal oxidation ditch system in a wastewater treatment plant in Beijing(China)were monitored under actual operation conditions.The flow field and DO concentration distributions were analyzed by computed fluid dynamic modeling.In situ monitoring and modeling both showed that the flow velocity was heterogeneous in the outer channel.As a result,the DO was also heterogeneously distributed in the outer channel,with concentration gradients occurring along the flow direction as well as in the cross-section.This heterogeneous DO distribution created many anoxic and aerobic zones,which may have facilitated simultaneous nitrification-denitrification in the channel.These findings may provide supporting information for rational optimization of the performance of the Orbal oxidation ditch.  相似文献   

7.
影响MBR脱氮效率的因素研究   总被引:17,自引:0,他引:17  
郑祥  刘俊新 《环境科学学报》2005,25(10):1325-1329
采用重力出流式膜生物反应器,考察了采用2种脱氮运行方式对生活污水脱氮的效果,同时对影响脱氮效率的相关因素进行了分析.研究结果表明,C/N是影响A/O与同步硝化反硝化(SND)2种运行方式脱氮效率最关键的因素.当C/N比小于12时,A/O方式的脱氮效率高于SND;随着C/N的升高,A/O与SND脱氮效率的差距逐渐缩小.对于A/O运行方式,在低C/N条件下可以通过提高回流比与增加缺氧段的HRT来提高系统的总氮去除率.而对于SND运行方式,好氧反硝化的完成是建立在有足够有机物作碳源的基础上,此时,DO的控制就成为提高脱氮效率的关键因素.  相似文献   

8.
A2O工艺处理生活污水短程硝化反硝化的研究   总被引:6,自引:2,他引:4       下载免费PDF全文
在常温条件下,采用A2O工艺处理低C/N比实际生活污水,通过控制好氧区DO为0.3~0.5mg/L以及增大系统内回流比以降低好氧实际水力停留时间(AHRT),成功启动并维持了短程硝化反硝化;系统亚硝态氮积累率稳定维持在90%左右.在C/N比仅为2.34的情况下,短程硝化系统对总氮(TN)的去除率高达75.4%.通过对不同碳源类型、不同硝化类型以及不同DO水平下A2O系统脱氮效率的比较研究发现,低氧短程硝化反硝化阶段与外加碳源的全程硝化反硝化阶段的TN去除率相当.同时研究表明,低DO运行并不会导致A2O工艺发生污泥膨胀.当接种污泥为膨胀污泥时,控制DO在0.3~0.5mg/L反而有助于改善污泥沉降性能和出水水质.  相似文献   

9.
To achieve high efficiency of nitrogen and phosphorus removal and to investigate the rule of simultaneous nitrification and denitrification phosphorus removal(SNDPR),a whole course of SNDPR damage and recovery was studied in a pilot-scale,anaerobicanoxic oxidation ditch(OD),where the volumes of anaerobic zone,anoxic zone,and ditches zone of the OD system were 7,21,and 280L,respectively.The reactor was fed with municipal wastewater with a flow rate of 336 L/d.The concept of simultaneous nitrification and denitrification (SND)rate(rSND) was put forward to quantify SND.The results indicate that:(1)high nitrogen and phosphorus removal efficiencies were achieved during the stable SND phase,total nitrogen (TN) and total phosphate(TP) removal rates were 80%and 85%,respectively;(2)when the system was aerated excessively,the stability of SND was damaged,and rSND dropped from 80% to 20%or less;(3)the natural logarithm of the ratio of NOx to MJ4 in the effluent had a linear correlation to oxidation-reduction potential (ORP);(4)when NO3- was less than 6 mg/L.high phosphorus removal efficiency could be achieved;(5)denitrifying phosphorus removal (DNPR) could take place in the anaerobic-anoxic OD system.The major innovation was that the SND rate was devised and quantified.  相似文献   

10.
以模拟低C/N比污水为研究对象,采用集成模块式污水处理装置与技术,在反应器主反应区实现了同步硝化反硝化(SND),研究了在不同DO、HRT、C/N比、pH值下污水氨氮、总氮的去除,研究结果表明,DO=1.2~1.4mg/L,总HRT=20h(主反应区HRT=8h),原水C/N=5:1,pH=7.5时,NH3--N可以从15mg/L降至2.5mg/L,总氮可以从20mg/L降至4mg/L,去除率可以达到83%和80%;主反应区SND动力学模型求解得出集成模块式污水处理SND动力学方程及反硝化过程中硝酸盐氮饱和常数 =1.55mg/L,远高于普通活性污泥反硝化过程中的饱和常数0.06~0.2mg/L.集成模块式污水处理技术能高效去除低C/N比污水中的总氮,且具有运行稳定和抗冲击等优点.为中小城镇生活污水深度脱氮提供了技术支持和理论基础.  相似文献   

11.
移动床膜生物反应器同步硝化反硝化特性   总被引:11,自引:3,他引:8  
杨帅  杨凤林  付志敏 《环境科学》2009,30(3):803-808
采用挂膜填料代替传统膜生物反应器(MBR)的活性污泥,构建一种新型的移动床膜生物反应器 (MBMBR),考察其处理模拟生活污水的效果及同步硝化反硝化(SND)特性.结果表明,移动床膜生物反应器运行67 d,对模拟生活污水表现出良好的去除有机物及同步硝化反硝化能力.进水COD浓度为573.5~997.7 mg/L时,膜出水COD去除率为88.3%~99.2%.进水氨氮浓度为45.5~99.2 mg/L时,膜出水氨氮去除率为72.1%~99.8%,总氮去除率为62.0%~96.3%.批式实验结果表明,生物膜去除总氮的最佳溶解氧浓度为1 mg/L,其中氨氮和总氮去除率分别为100%和60%.生物膜系统内可能存在好氧反硝化现象.DO为3 mg/L且有机碳源充足时,生物膜总氮去除率为99.0%,SND率达到99.8%.扫描电镜对生物膜的观察发现生物膜内部存在着明显的孔隙,有利于溶解氧和有机基质从外界向生物膜内部传递.  相似文献   

12.
HITNP同步除磷脱氮新工艺   总被引:5,自引:0,他引:5  
HITNP同步除磷脱氮新工艺采用复合式活性污泥生物膜系统,避免了硝化菌和聚磷菌的污泥龄矛盾.利用反硝化除磷的“一碳两用”缓解原水碳源不足的矛盾.通过独特的硝化液回流方式,使全部污泥经历了释磷和聚磷循环,厌氧池污泥浓度是缺氧池污泥浓度的1.5~2倍,对进水中的大分子有机物降解效果好,厌氧池COD的去除率高,强化系统的除磷能力.以低碳氮比的生活污水为处理对象,长期的运行结果表明,该工艺出水中的总磷、氨氮、总氮和COD的去除率分别为91.1% 、88.7%、58.1%和88.6%.出水水质平均值为磷0.27  mg/L,氨氮1.74  mg/L,总氮17.30  mg/L和COD 24.38  mg/L.HITNP同步除磷脱氮新工艺具有稳定的同步除磷脱氮效果,出水达到国家城市污水厂污染物排放标准GB18918-2002一级B标准要求.  相似文献   

13.
氧化沟工艺低氧同步脱氮启动研究   总被引:1,自引:1,他引:0  
在常温条件下,采用小试Pasveer氧化沟处理低C/N实际污水,通过控制好氧区平均ρ(DO)为0.2~0.4 mg/L,保持好氧区与缺氧区体积比为1∶1,成功实现低氧脱氮过程。其中,模式1先接种好氧污泥并逐渐降低好氧区DO,然后接种缺氧污泥;模式2初始阶段保持低氧环境,并直接接种好氧和缺氧混合污泥。结果显示:两种方式均能成功启动低氧脱氮并保持较高的脱氮率;同时,当C/N值为1.94时,氨氮去除率较高;当C/N值为3.00时,总氮去除率较高,低氧低碳条件下脱氮效果较好。  相似文献   

14.
利用城市实际污水考察了ρ(MLSS)在2 400、3 350、4 300和5 250 mg/L 4种工况下SBR反应器(厌氧/好氧/缺氧/再好氧/沉淀/排水/预缺氧运行模式)的脱氮除磷效果,并分析了反应器单个周期内有机物、氮和磷的转化过程及污泥产量. 结果表明:ρ(MLSS)由2 400 mg/L升至5 250 mg/L时,系统TN去除率由52.5%升至66.6%;后续缺氧及预缺氧工序的脱氮比例(该工序TN去除量占系统TN总去除量的比例)由12.7%增至23.1%;ρ(MLSS)为4 300 mg/L时系统TP去除率(75.6%)达到最大. 后续缺氧及预缺氧工序中,ρ(MLSS)与内源反硝化速率呈正相关(R2=0.703 7);提高ρ(MLSS)可使PAOs(聚磷菌)在下一个周期内获得更多的碳源,使厌氧释磷量由1.62 mg/L升至9.10 mg/L,但PAOs吸磷动力会减弱,对除磷不利. 在后置反硝化、污泥衰减、能量解偶联等减量机制共同作用下,ρ(MLSS)为4 300 mg/L时系统污泥减量可提高24.4%. 从脱氮除磷及污泥减量效果综合考虑,ρ(MLSS)是双重后置反硝化工艺重要的控制参数,在该研究条件下控制在4 300 mg/L最优.   相似文献   

15.
DO C/N对同步硝化反硝化影响的试验研究   总被引:4,自引:1,他引:3  
在序批式活性污泥反应器(SBR)内,以模拟的城市污水为处理对象,研究DO、C/N等因素对同步硝化反硝化脱氮效率的影响。研究表明:采用连续曝气工艺,在进水COD=200mg/L,NH4+-N=30mg/L条件下,控制DO在0.5~1.5mg/L范围内时,出水TN浓度为1.98~6.3mg/L,TN的平均去除率在80%以上,最高去除率达到93.74%,并可推断出在反应系统内存在好氧反硝化菌;C/N在3.3~10之间时,C/N越高,出水NO3--N浓度越低,SND效果越好。  相似文献   

16.
为了解厌氧/好氧运行的序批式反应器(SBR)中,强化生物除磷(EBPR)与同步硝化反硝化(SND)的耦合脱氮除磷特性,以实际低C/N (约为3.5)生活污水为处理对象,先通过调控进水C/N考察其对EBPR启动和聚磷菌(PAOs)富集情况的影响,再通过调控好氧段DO浓度考察其对系统脱氮除磷性能、SND率及碳源转化特性的影响.结果表明,DO浓度为2.0mg/L,当进水C/N由3.2提高至7.5并降至3.8时,反应器出水PO43--P浓度由3.9mg/L逐渐降至0.5mg/L以下,且厌氧释磷量(PRA)由3.3mg/L逐渐升高至约30mg/L.此后,当DO浓度逐渐降至约1.0mg/L时,SND现象愈加明显,且其与EBPR耦合使得系统总氮(TN)和PO43--P去除率分别提高至85%和94%.但当DO浓度约为0.5mg/L时,硝化过程进行不完全,亚硝酸盐积累较为明显,耦合系统中存在同步短程硝化反硝化现象.DO浓度为约1.0mg/L时,系统具有最高的脱氮除磷性能.此外,当DO浓度由2.0mg/L降至0.5mg/L时,PAOs较聚糖菌(GAOs)在厌氧内碳源储存中的贡献逐渐减小(PPAO,An由30.3%逐渐降至20.2%),PRA降低约7mg/L.DO浓度为1.0~1.5mg/L最有利于系统厌氧段内碳源PHA的合成.  相似文献   

17.
采用单级A/O程序复合膜生物反应器(HSMBR)处理高氨氮废水,研究在低DO浓度下系统对有机物、氨氮和总氮的去除效率。研究结果表明:在低DO浓度下,CODCr、氨氮的平均去除率分别为94.4%和92.8%。由于进水CODCr/TN值仅为2.01,则使得总氮平均去除率仅为69.4%,但是当系统亚硝化累积率从60.5%~67.1%提高到83.5%~86.4%时,系统总氮去除率提高了17.7%。另外,维持低DO浓度可以实现亚硝酸型同时硝化反硝化反应。  相似文献   

18.
李冬  李悦  杨敬畏  李雨朦  张杰 《中国环境科学》2022,42(10):4581-4587
室温下接种成熟好氧颗粒污泥于SBR反应器中,以实际生活污水为进水基质,采用梯度进水联合优化A/O/A时间配比策略以期提高污泥的脱氮除磷效果.结果表明,缺氧时间由0.5h延长至1.5h时,能同时保证脱氮除磷高效进行.此时A/O/A时间比为1:1.6:1,平均TN去除率提高至81.27%,平均TP去除率保持90%以上,平均COD去除率保持在85%以上.同时,同步硝化反硝化(SND)率降低至25.24%,缺氧吸磷比例由0.43%上升至2.81%,进而说明此A/O/A时间比下反硝化糖菌(DGAOs)的反硝化作用对脱氮的贡献增加.缺氧时间延长至2h,A/O/A时间比为3:5:4时,过度缺氧导致微生物内源呼吸和丝状菌繁殖,平均TN、TP去除率降低至51.48%、72.46%.缺氧时间为1.5h时,MLSS为3501mg/L较低,但MLVSS/MLSS(f)升高至0.95,说明淘洗掉了非功能菌,使脱氮除磷功能菌大量生长.随缺氧时间延长至1.5h,即A/O/A时间比为1:1.6:1,PN/PS增加至6.89,故颗粒稳定性不断增强,在1h以内缺氧时间延长对LB-EPS影响更大且对EPS含量影响不大,超过...  相似文献   

19.
好氧颗粒污泥膜生物反应器脱氮特性   总被引:4,自引:1,他引:3  
好氧颗粒污泥膜生物反应器(GMBR)连续运行71 d,对模拟生活污水表现出良好的有机物去除及同步硝化反硝化(SND)能力.进水TOC浓度为56.8~132.6mg/L时,膜出水TOC去除率为84.7%~91.9%;进水氨氮浓度为28.1~38.4mg/L时,稳定运行阶段氨氮去除率为85.4%~99.7%,总氮去除率为41.7%~78.4%.结合反应器中污泥生长形态,对不同粒径污泥的同步硝化反硝化研究表明,好氧条件下絮状污泥几乎没有反硝化能力,SND能力来源于颗粒污泥,并且随着污泥粒径的增大,反硝化速率以及总氮去除效率提高.通过扫描电镜对颗粒污泥外观以及沿传质方向剖面内部特征的观察分析,对颗粒污泥同步硝化反硝化的作用过程进行了探讨.  相似文献   

20.
内循环对A2/O-曝气生物滤池工艺脱氮除磷特性影响   总被引:8,自引:6,他引:2  
在原水温度为15℃和C/N为4.9的条件下,以实际生活污水为研究对象,重点考察了内回流比为100%、200%、300%和400%时小试规模A2/O-曝气生物滤池工艺脱氮除磷特性.结果表明,该生化系统可实现有机物、氮和磷的同步深度去除.在总HRT为8.0 h、SRT为15 d、污泥回流比为100%和MLSS为4.0 g·...  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏