首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
2.
3.
Antoine Ghauch   《Chemosphere》2008,72(2):328-331
The following comments are proposed to clarify some related issues on the use of zero valent iron micrometric particles for the treatment of a thiobencarb pesticide solution published in a recent article by Nurul Amin et al., [Nurul Amin Md., Kaneco, S., Kato, T., Katsumata, H., Susuki, T., Otha, K., 2008. Removal of thiobencarb in aqueous solution by zero valent iron. Chemosphere 70 (3), 511–515], and discussed later by Chicgoua Noubactep.  相似文献   

4.
5.
6.
7.
Chemical composition of rainwater was studied in the northeastern Romania, Iasi region, and the concentrations of major inorganic and organic ions were measured in samples collected between April 2003 and December 2006. The pH of the rainwater is 5.92 (volume weighted mean average, VWM) suggesting a sufficient load of alkaline components neutralizing its acidity. On average, 97% of the acidity in the collected samples is neutralized by CaCO3 and NH3. Clear seasonal variations were observed for some of the identified ions (e.g., SO42−, NO3, Ca2+, NH4+). The data obtained during this work revealed that both concentrations and fluxes of anthropogenic source-related ions (e.g., SO42−, NO3 and NH4+) are among the highest reported for European sites. It is shown that meteorology and long-range transport processes may concur to their high levels.  相似文献   

8.
The ozone records of several monitoring stations in Switzerland from 1992 to 1998 are investigated with respect to the variability observed during regional background conditions, i.e. conditions with little detectable local or regional-scale influences as evident by NOx and CO concentrations. The sites cover different altitudes between 490 and 3600 m asl. They are characteristic of near-surface conditions, the top of the planetary boundary layer or residual layer, the complex atmosphere in an alpine valley, and the free troposphere. The results reveal a distinctly different ozone variability (diurnal cycles, seasonal cycles, trends) during regional background conditions compared to all days. The estimated annual average ozone concentration under these conditions is between 33 and 50 ppb, dependent on altitude, with a spring maximum and an autumn/winter minimum. Differences in background ozone are found depending on the synoptic weather type. For all sites a positive ozone trend is calculated for background conditions that is larger than for all data. For the latter, the trends appear to be stronger positive for the last 7 years than for the last 11 years.  相似文献   

9.
10.
11.
Kurt B. Carlsson 《Chemosphere》1989,18(9-10):1731-1736
The graph below shows the emitted dioxin - equivalents (Eadon) in grams per year in flue gas from municipal solid waste incinerators with various air pollution control methods for plants of capacity of 200 000 ton municipal solid waste (MSW) per year.

With optimized combustion and an effective air pollution control system the emissions of dioxins can be kept very low (concentrations below 0.1 ng/m3n).

With a very effective air pollution control system the total emission from all Swedish MSW-incinerators burning approximately 1.5 Mton/year will by 1990 be below 2 g/year - a drastic reduction from approximately 15 g today. As the total dioxin - equivalent emission to the environment in Sweden in the year 1987 was almost 500 g we see that municipal waste incineration really is on the way to solve their dioxin problem.  相似文献   


12.
13.
Nitrogen deposition in Finland was investigated on the basis of the nitrogen concentration in the forest moss, Hylocomium splendens, collected during heavy metal moss surveys carried out in 1990, 1995, 2000, and 2005/06. Significant regional differences were found in the nitrogen concentrations in mosses. The concentrations were the highest in the southern part of the country in all the surveys, with a decreasing trend on moving northwards. The mean concentrations in the surveys were 1.07%, 1.00%, 0.89% and 0.92%. In general, the concentrations in mosses reflected nitrogen deposition at the level of the whole country. However, they did not correlate very well with the modelled nitrogen deposition because of the high local variation in the nitrogen concentration in H. splendens. One reason for the high variation was the effect of the structure of the tree stand on nitrogen concentrations in H. splendens.  相似文献   

14.
Brominated dibenzo-p-dioxin and dibenzofuran (BDD/BDF) isomers, specifically having from one to three halogens located in the 2,3,7,8-substituent positions, that are [13C]-labeled for use as analytical internal standards in mass spectrometric methods are not yet commercially available. Based upon the current availability of [13C]-labeled dibenzo-p-dioxin and dibenzofuran (DD/DF) precursors, we have developed a simple and efficient synthetic procedure which produces brominated congeners that are predominantly substituted in the 2,3,7, and 8-positions. The gas/solid reaction of vaporized precursor and surface-supported iron (III) bromide occurs rapidly (seconds) at temperatures ≥ 240°C and can provide total product yields in the range of 30 to 50 mole % for initial precursor amounts between 1 μg and 10 mg. In this paper we shall describe the utility of this approach to produce 5 μg quantities of [13C12]-2,7-dibromodibenzo-p-dioxin (27-DBDD) and [13C12]-2,8-dibromodibenzo-p-dioxin (28-DBDD).  相似文献   

15.
16.
The objective of this study is to investigate the air ventilation impacts of the so called “wall effect” caused by the alignment of high-rise buildings in complex building clusters. The research method employs the numerical algorithm of computational fluid dynamics (CFD – FLUENT) to simulate the steady-state wind field in a typical Hong Kong urban setting and investigate pollutant dispersion inside the street canyon utilizing a pollutant transport model. The model settings of validation study were accomplished by comparing the simulation wind field around a single building block to wind tunnel data. The results revealed that our model simulation is fairly close to the wind tunnel measurements. In this paper, a typical dense building distribution in Hong Kong with 2 incident wind directions (0° and 22.5°) is studied. Two performance indicators are used to quantify the air ventilation impacts, namely the velocity ratio (VR) and the retention time (Tr) of pollutants at the street level. The results indicated that the velocity ratio at 2 m above ground was reduced 40% and retention time of pollutants increased 80% inside the street canyon when high-rise buildings with 4 times height of the street canyon were aligned as a “wall” upstream. While this reduction of air ventilation was anticipated, the magnitude is significant and this result clearly has important implications for building and urban planning.  相似文献   

17.
18.
19.
20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号