首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The overall objective of this research was to investigate various methods and parameters to increase the efficiency of chemically enhanced primary treatment (CEPT). The performance of CEPT was evaluated based on its efficiency of removal of nonsettleable solids (NSS). Some of the source characteristics that influenced NSS concentration included influent total suspended solids, influent turbidity, and influent total chemical oxygen demand. A higher concentration of the influent constituents led to a higher NSS concentration, suggesting that NSS represented a somewhat fixed fraction or percent of these influent constituents. The specific particle surface area (SPSA) was found to correlate with percent NSS in the effluent. A higher SPSA is a result of smaller-sized nonsettleable colloidal particles, thus leading to an increase in percent NSS. In summary, there are several parameters that affect NSS, which could be used to control NSS to improve CEPT, as demonstrated by this study.  相似文献   

2.
This project has two main objectives; the first is to documents the effect of a porous friction course overlay on the quality of highway stormwater runoff, and the second is to assess pollutant removal of a vegetated area along the side of a road from both conventional and porous pavements. The quantity and quality of stormwater runoff from a four-lane divided highway in the Austin, Texas, area was monitored before and after the installation of a porous friction course (PFC). Observed concentrations of suspended solids and pollutants associated with particulate material were much lower in the runoff from the PFC compared with runoff from the conventional asphalt surface. The vegetated highway shoulder reduced the concentrations of many stormwater constituents from the conventional asphalt surface; however, the concentrations of these constituents in runoff produced by the PFC were so low that the vegetated area produced no further reduction in concentration.  相似文献   

3.
The objective of this research was to modify an extended detention basin to provide batch treatment of stormwater runoff. An automated valve/controller was developed and placed on the outlet of a detention basin in Austin, Texas, which allowed the water quality volume to be retained in the basin for a preset length of time. The influent and effluent of the modified basin were monitored for total suspended solids (TSS), nutrients, chemical oxygen demand (COD), and total and dissolved metals. Statistically significant removal of total metals, COD, total nitrogen, total phosphorus, and TSS was observed, with a discharge event mean TSS concentration of 7 mg/L and a TSS removal efficiency of 91%. The modified basin has substantially better pollutant removal than conventional extended detention basins and is comparable with that of Austin sand filters, which are a common structural stormwater treatment system in the Austin area. The valve also can be used to isolate hazardous material spills.  相似文献   

4.
In a storm sewer system, the catch basin is the interface between surface runoff and the sewer. Responding to the need to improve the quality of stormwater from urban areas and transportation facilities, and spurred by Phase I and II Stormwater Rules from the U.S. Environmental Protection Agency, several companies market catch basin inserts as best management practices for urban water quality management. However, little data have been collected under controlled tests that indicate the pollutant removal efficiency of these inserts when the inflow is near what can be expected to occur in the field. A stormwater simulator was constructed to test inserts under controlled and replicable conditions. The inserts were tested for removal efficiency of total suspended solids (TSS) and total petroleum hydrocarbons (TPH) at an inflow rate of 757 to 814 L/min, with influent pollutant concentrations of 225 mg/L TSS and 30 mg/L TPH. These conditions are similar to stormwater runoff from small commercial sites in the southeastern United States. Results from the tests indicate that at the test flowrate and pollutant concentration, average TSS removal efficiencies ranged from 11 to 42% and, for TPH, the removal efficiency ranged from 10 to 19%.  相似文献   

5.
A Monte Carlo simulation technique was applied to assess the effect of stormwater quality volume captured by best management practices (BMPs) on the frequency of discharging concentrations of constituents above certain designated threshold limits. The method used an assumption of a power law relationship between the cumulative load and flow to incorporate the first flush effect. The exponent of this relationship was considered a random variable and its frequency distribution was obtained from 78 measured pollutographs from three urban highway sites in West Los Angeles, California. Although the effect of rain depth captured by BMPs is site-specific, the method offered here provides a systematic approach to evaluate the effect of selecting various regulatory guidelines for controlling urban stormwater pollution on the overall discharge of pollutants into waterways. This allows selecting the requirements for capturing runoff volume by BMPs based on the tradeoff between the probability of concentration criteria violation and economic factors.  相似文献   

6.
生物滞留池改善城市雨水径流水质的研究进展   总被引:6,自引:0,他引:6  
如何有效控制城市雨水径流所带来的面源污染已成为城市管理工作所面临的重要难题之一.作为城市暴雨最佳管理措施(BMPs)中的技术之一,生物滞留池可有效控制城市面源污染.总结了生物滞留池在改善城市雨水径流水质方面的研究进展,简要分析了生物滞留池去除污染物的机制.研究结果表明,生物滞留池对雨水径流中的总悬浮颗粒物(TSS)、重...  相似文献   

7.
根据城市初期雨水径流的污染负荷初始冲刷效应以及主要污染物COD和N/P与SS成线性相关性的污染特点,对初期雨水的主要污染物COD和N/P开展了控制技术研究。以示范工程为基础,研究城市初期雨水径流污染控制的强化处理技术即沸石渗滤床技术,运行结果表明,对NH3-N、TP、COD都有较好的去除效果,其中对NH3-N的去除效果较为明显,进水氨氮浓度在2~5 mg/L,出水都能达到地表IV类水标准(NH3-N≤0.5 mg/L)。  相似文献   

8.
对序批式反应器 (SBR)用于牛场污水的处理进行了试验研究 ,主要研究了三个水力停留时间 (HRT)和有机负荷率对污染物去除率、出水水质和污泥特性的影响。试验结果表明 ,对 10 0 0 0mg/LCOD牛场污水 ,使用 1dHRT ,相应有机负荷率为 10gCOD/L·d时 ,混合出水COD、TS、VS、TKN和TN的去除率分别为 45 %、2 1.4%、34 .2 %、5 3.2 %和 2 2 .2 % ,上清液出水的分别为 80 .2 %、6 3.4%、6 6 .2 %、75 %和 38.3% ;两种出水的SCOD和NH3 N去除率相同 ,分别为 5 0 .0 %和 76 .5 %。经SBR处理后 ,污泥的沉降浓缩性能也有了比较明显的改善。  相似文献   

9.
COD浓度和进水流量比对一体化工艺脱氮除碳的影响   总被引:1,自引:1,他引:0  
保持进水总流量不变,以一定流量比同时从缺氧区和厌氧区进水,探讨了不同进水流量比(R=Q/Q)和进水COD浓度对中心岛式一体化OCO工艺脱氮除碳的影响。研究结果表明,进水COD浓度和进水流量比Rs对COD的去除效果影响不大,出水COD浓度一直稳定在50 mg/L以下,去除率在92%以上;进水COD浓度和进水流量比Rs共同决定着系统TN的去除效果,进水COD浓度为100 mg/L、200 mg/L时,TN去除率随着进水流量比Rs的减小呈增加的趋势;当进水COD浓度为 300 mg/L时,TN去除率随着进水流量比Rs的减小呈先升高后降低的趋势,在进水流量比Rs为3∶1时TN去除率最高,达到87%。  相似文献   

10.
The purpose of this study was to investigate the characterization of the event mean concentration (EMC) of runoff during heavy precipitation events on highways. Highway runoff quality data were collected from the 7th highway, in South Korea during 2007-2009. The samples were analyzed for runoff quantity and quality parameters such as CODcr, TSS, TPHs, TKN, NO3, TP, PO4 and six heavy metals, e.g., As, Cu, Cd, Ni, Pb and Zn. Analysis of resulting hydrographs and pollutant graphs indicates that the peak of the pollutant concentrations in runoff occurs 20 min after the first rainfall runoff occurrence. The first flush effect depends on the preceding dry period and the rainfall intensity. The results of this study can be used as a reference for water quality management of urban highways.  相似文献   

11.
曝气生物滤池处理农村污水的中试研究   总被引:4,自引:3,他引:1  
采用研制的曝气生物滤池对农村污水进行处理,研究其性能特点和影响因素。结果表明:在气水比为5∶1,水力停留时间(HRT)为15 h,进水COD浓度在250 mg/L以下时,COD和氨氮的去除率分别在80%和90%以上,出水COD和氨氮值达到国家《城镇污水处理厂污染物排放标准》一级A标准;反应器在冬季水温12℃以上运行时出水COD和氨氮值比在夏季运行时有所上升,但去除率仍在80%和90%以上,可以达到排放标准。  相似文献   

12.

Bioretention systems have been implemented as stormwater best management practices (BMPs) worldwide to treat non-point sources pollution. Due to insufficient research, the design guidelines for bioretention systems in tropical countries are modeled after those of temperate countries. However, climatic factors and stormwater runoff characteristics are the two key factors affecting the capacity of bioretention system. This paper reviews and compares the stormwater runoff characteristics, bioretention components, pollutant removal requirements, and applications of bioretention systems in temperate and tropical countries. Suggestions are given for bioretention components in the tropics, including elimination of mulch layer and submerged zone. More research is required to identify suitable additives for filter media, study tropical shrubs application while avoiding using grass and sedges, explore function of soil faunas, and adopt final discharged pollutants concentration (mg/L) on top of percentage removal (%) in bioretention design guidelines.

  相似文献   

13.
The present work consists of two distinct parts: in the first part enantioselective GC was used to separate the different enantiomeric/diastereomeric polycyclic musks, PCMs (HHCB, AHTN, AHDI, ATII and DPMI) including the main transformation product of HHCB, HHCB-lactone, in wastewater and sewage sludge. After optimization all PCMs were resolved on a cyclodextrin containing Rt-BDEXcst capillary GC column. Enantiomeric ratios of PCMs in a technical mixture were determined and compared to those obtained from enantioselective separation of wastewater and sewage sludge samples. In general, enantiomeric ratios were similar for most materials in influent, effluent and stabilized sewage sludge. However, the ratios for HHCB, AHDI and particularly ATII suggest some stereospecific removal of these compounds. In the second part, a field study was conducted on a wastewater treatment plant comprising a sequencing batch reactor. Concentrations of HHCB, AHTN, ADBI, AHDI, ATII, DPMI and HHCB-lactone were determined by non-enantioselective GC in daily samples of influent, effluent and activated sludge during one week. Mean concentrations in influent were 6900 and 1520 ng/l for HHCB and AHTN, respectively. The other PCMs exhibited contents 200 ng/l. Mean percent removal was between 61% (AHDI) and 87% (HHCB) resulting in mean effluent concentrations below 860 ng/l. HHCB-lactone concentration increased during wastewater treatment with a mean in the influent of 430 ng/l and in the effluent of 900 ng/l, respectively, indicating a degradation of HHCB.  相似文献   

14.
以某城市污水厂进水为研究对象,采用A2/O+硫磺填料反应柱组合工艺,考察其对COD、总氮、总磷以及溶解性磷处理效果的改善。组合工艺出水水质稳定后,连续运行55 d,并对工艺的出水进行常规指标分析。结果表明:组合工艺的脱氮除磷效果较单个A2/O工艺都得到了较大的改善,而COD去除效果变化不大。A2/O系统对COD有良好的去除效果,出水的COD平均去除率能达到94%;TN和TP去除效果相对较差,出水平均去除率分别为60%和57.4%。经硫磺填料反应柱的脱氮除磷作用,系统出水TN去除率提高到84%,TP去除率提高到69.8%,COD去除率变化不大,升高到95.3%。  相似文献   

15.
以某城市污水厂进水为研究对象,采用A2/O+硫磺填料反应柱组合工艺,考察其对COD、总氮、总磷以及溶解性磷处理效果的改善。组合工艺出水水质稳定后,连续运行55 d,并对工艺的出水进行常规指标分析。结果表明:组合工艺的脱氮除磷效果较单个A2/O工艺都得到了较大的改善,而COD去除效果变化不大。A2/O系统对COD有良好的去除效果,出水的COD平均去除率能达到94%;TN和TP去除效果相对较差,出水平均去除率分别为60%和57.4%。经硫磺填料反应柱的脱氮除磷作用,系统出水TN去除率提高到84%,TP去除率提高到69.8%,COD去除率变化不大,升高到95.3%。  相似文献   

16.
COD对生物除磷颗粒污泥稳定性影响研究   总被引:3,自引:1,他引:2  
颗粒污泥稳定性是影响其应用的主要因素之一.以SBR中成熟的生物除磷颗粒污泥为研究对象,探讨进水COD浓度对系统稳定性的影响.结果表明,当进水COD浓度由300 mg/L逐渐升高到500 mg/L时,磷去除率由93%降低到88%;当进水COD浓度在400 mg/L以下时,污泥的最大比释磷速率和比吸磷速率分别为45.2 m...  相似文献   

17.
This paper investigated the highway stormwater quality at two Texas cities-Austin and College Station. Two highways with high average daily traffic were monitored using passive stormwater samplers for collecting first-flush runoff during a 16-month period. Detailed traffic and weather data were collected at College Station sites, but only weather data were obtained at Austin sites. A stepwise regression analysis on College Station data identifies the antecedent dry period (ADP) as the most significant predictor of pollutant concentration. Specifically, the College Station data show an unexpected result that pollutant event mean concentrations significantly decrease with increasing ADP for all analyzed pollutants. However, the runoff concentrations observed in Austin were not significantly correlated with ADP. The result from College Station data provides a different insight to the pollutant buildup and removal process on highways. Conceptual highway pollutant buildup and removal models are proposed for generating further discussion and research interest.  相似文献   

18.
焦化废水中COD、挥发酚和硫氰化物同步高效去除   总被引:1,自引:0,他引:1  
采用两级膨胀颗粒污泥床(EGSB)反应器在微氧条件下处理焦化废水,考察了该工艺对焦化废水中挥发酚、硫氰化物、氰化物和COD的去除效果。研究结果表明,在进水流量为1 L/h,总水力停留时间(HRT)为24 h的条件下,两级EGSB反应器对COD的去除效果较好。稳定运行时,在进水挥发酚为56.8~185.1 mg/L、硫氰化物为287.1~539.9 mg/L、氰化物为0.17~0.72 mg/L的条件下,系统对其平均去除率分别为99.9%、96.8%和82.6%,出水挥发酚和氰化物均能达到《污水综合排放标准(GB8978-1996)》的一级标准。进水COD浓度在1 084~1 880 mg/L之间,平均去除率为76.9%,出水平均浓度为325 mg/L。  相似文献   

19.
城市区域不同屋顶降雨径流水质特征   总被引:6,自引:0,他引:6  
城市屋顶降雨径流是城市面源污染的主要组成部分之一。为了解城市不同屋顶降雨径流的水质特性,以重庆地区5种屋顶为例进行了20场降雨径流的水质监测。研究结果表明,不透水屋顶降雨径流污染物浓度均随降雨历时的延长而降低,混凝土屋顶降雨径流的COD、TP、TN、NH3-N平均浓度分别是瓦屋顶的1.6、1.7、1.4和1.5倍,且不透水屋顶降雨径流总氮的70%~80%为无机氮,总磷的20%~32%为磷酸盐;浅层屋顶降雨径流COD、TN、TP、NH3-N和NO-3-N浓度分别是深层绿色屋顶的0.25~0.26、0.3~0.5、0.07~0.09、0.3~0.6、0.05~0.06倍,且绿色屋顶降雨径流总氮的60%~80%为硝态氮。前期干旱天数和混凝土屋顶径流中的TN、接骨草屋顶径流中的氨氮浓度呈显著正相关关系,混凝土屋顶径流TP浓度与降雨强度显著正相关,降雨持续时间和瓦屋顶径流TSS平均浓度显著正相关。研究结果为城市建筑屋顶降雨径流的科学管理提供了参考。  相似文献   

20.
不同工艺再生水补给对景观湖水质变化的影响   总被引:2,自引:0,他引:2  
李娜  杨建  常江  甘一萍  吕刚 《环境工程学报》2012,6(4):1276-1280
再生水回用于景观水体过程中,为了比较不同再生水工艺对景观水体富营养化的影响,以"二级出水+BAF+O3+GFH"和"二级出水+O3"作为再生水处理工艺,以岸滤(bank filtration,BF)作为水质维持工艺,进行再生水景观水体水质保障技术研究。结果表明,"二级出水+O3"出水流量较大,水力流动快,每天运行24 h,平均出水流量25.5 m3/d,氮磷含量偏高;"二级出水+BAF+O3+GFH"出水的氮磷指标控制在较低水平,GFH出水流量8~14 m3/d,水力流动较缓,湖中出现蓝藻。2套系统中BF对NH4+-N的去除率分别为30.5%和20.8%。"二级出水+O3+BF"系统中人工湖进水TN平均浓度24.309 mg/L,TP平均浓度0.583 mg/L,N/P=41,适宜水网藻生长,对湖中N(主要是NH4+-N)、P有较强的去除能力;"二级出水+BAF+O3+GFH+BF"系统中人工湖进水TP<0.05 mg/L,适宜蓝藻生长。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏