首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
根据广州从化市玮思工业园排放的综合污水的特点,设计了生物接触氧化—复合人工湿地组合工艺对其进行处理,考察了该工艺运行一年来对COD、BOD5、TP、NH4+ -N、TN的去除效果.结果表明,该组合工艺对工业园区综合污水中的COD、BOD5、TP、NH4+ -N和TN都有较好的去除效果,出水COD、BOD5、TP、NH4+ -N、TN的平均去除率分别为86.07%、74.91%、60.73%、89.62%、46.01%;该组合工艺对各污染物的去除效果明显优于单一的生物接触氧化池和单一的复合人工湿地的去除效果,生物接触氧化池对COD、BOD5和NH4+ -N的去除贡献较大,但对TP和TN的去除能力有限;采用该组合工艺处理工业园区综合污水,具有运行费用低、处理效果好、操作方便、管理简单、景观效果良好等优点.  相似文献   

2.
A/O膜生物反应器处理高浓度氨氮废水试验研究   总被引:4,自引:0,他引:4  
对A/O膜生物反应器处理高浓度氨氮废水进行了研究,着重考察硝化液回流比和C/N对系统脱氮效能的影响.研究表明,当硝化液回流比为2、C/N为6时.系统对COD、氨氮、TN的平均去除率分别达96.17%、97.76%、76.29%;A/O膜生物反应器稳定运行期间,氨氮容积负荷去除量与进水氨氮容积负荷呈现良好的线性关系;当A/O膜生物反应器内MLSS稳定在9~13 g/L时,上清液COD较低,膜压差增长缓慢.  相似文献   

3.
单级与二级BAF工艺除碳硝化效能的对比研究   总被引:1,自引:0,他引:1  
在总曝气量、HRT、水温、进水水质相同的条件下,对比研究了单级(BAF C/N)和二级曝气生物液池(BAF C+N)处理生活污水的除碳硝化效能。结果表明,将除碳和硝化分级有利于提高BAF工艺的处理效能。分级后,C柱较C/N柱具有更高的COD去除容积负荷,且出水COD浓度稳定低于50 mg/L;二级BAF工艺出水NH4+-N浓度由单级BAF的5~12 mg/L降至5 mg/L以下,且N柱在pH<6.3时依然能够进行硝化;N柱中下部具有较高的微生物活性,平均比耗氧速率为32 mg O2/(g VAS·h)。二级BAF中C柱的反冲洗周期和强度与单级BAF相同,而N柱的反冲洗周期则延长至5~7 d,能够降低反冲洗能耗和用水量。  相似文献   

4.
生物处理单元采用水解酸化、多级串联接触曝气、连续流的除磷脱氮A2/O工艺,并辅以外排厌氧富磷污水侧流除磷,开发了一个新型的具有强化除磷脱氮功能的污泥减量HA—A/A—MCO工艺。用该工艺处理校园生活污水发现,在SRT60d、进水COD316~407mg/L、NH4+-N30~40mg/L、TN35~53mg/L、TP8—12mg/L的条件下,出水COD≤18mg/L、NH4+-N≤2.1mg/L、TN≤10.3mg/L、TP≤0.44mg/L。研究还发现,水解酸化池处理产生的VFA能有效促进生物除磷脱氮,导致厌氧释磷量达57mg/L,进入化学除磷池的侧流液量仅相当于进水量的13%;系统最主要的脱氮形式是SND和缺氧反硝化,SND脱氮占脱氮总量的50%,缺氧反硝化占26%;HA-A/A—MCO系统有效实现了生物相分离,并利用生物捕食作用获得较低的污泥产率,0.1gMLSS/gCOD。  相似文献   

5.
实验利用序批式反应器(SBR)考察反硝化除磷颗粒污泥搁置1个月后重新投入运行,其活性恢复能力及对实际生活污水的处理效果。结果表明,颗粒污泥搁置后外观由淡黄色转变为灰黑色,颗粒重新投入反应器,11 d后颜色基本恢复,污泥浓度及活性迅速增加;对COD处理能力的恢复历时14 d,去除率稳定在80.32%以上;颗粒污泥对NH4+-N和PO34--P的去除在40 d时也恢复到正常水平;反硝化聚磷菌(DNPAOs)活性恢复期为50 d。颗粒污泥对低碳氮比的实际生活污水处理结果显示,当C/N<5.1时(生活污水比例>60%),无法满足系统内微生物生长要求,需要外加适量碳源进行补充。  相似文献   

6.
The ecotoxicity of silver nanoparticles (Ag-NPs) to wastewater biota, including ammonia oxidizing bacteria (AOB), is gaining increasing interest as the number of products containing Ag-NPs continues to rise exponentially and they are expected to accumulate in wastewater treatment plants. This research demonstrated that the addition order of Ag-NP and the media constituents had a profound influence on the stability of the Ag-NP suspension and the corresponding repeatability of results and sensitivity of Nitrosomonas europaea. N. europaea, a model AOB, was found to be extremely sensitive to ionic silver (Ag+) and two sizes of Ag-NPs (20 and 80 nm). Ag+ exposures resulted in the highest level of toxicity with smaller Ag-NPs (20 nm) being more toxic than larger Ag-NPs (80 nm). The increased sensitivity of N. europaea to smaller Ag-NPs was caused by their higher rates of dissolved silver (dAg) release, via dissolution, due to a greater surface area to volume ratio. dAg was shown to be responsible for the vast majority of the observed Ag-NP toxicity, as determined by abiotic Ag-NP dissolution tests. For the sizes of Ag-NP studied (20 and 80 nm), there appears to be a negligible nanoparticle-specific toxicity. This was further supported by similarities in inhibition mechanisms between Ag+ and Ag-NP, with both causing decreases in AMO activity and destabilization of the outer-membrane of N. europaea. Finally, equal concentrations of total silver were found to be tightly associated to both Ag+ and Ag-NP-exposed cells despite Ag-NP concentrations being five times greater, by mass, than Ag+ concentrations.  相似文献   

7.
固定化膜生物反应器处理含抗生素污水   总被引:2,自引:0,他引:2  
采用细菌固定化技术包埋活性污泥浓缩液,并利用A/O膜生物反应器处理含抗生素生活污水,考察了膜生物反应器在抗生素存在条件下降解有机物及氮素的性能,并对土霉素为代表的抗生素的去除效果进行分析。结果表明,人工模拟抗生素污水的COD、TOC、NH4+-N、TN及土霉素浓度分别为325~413、101.35~206.10、15.51~24.54、15.00~25.30和0.17~0.47 mg/L,水力停留时间为6、12和24 h的条件下,系统的出水平均COD、TOC、NH4+-N和TN分别维持在50、20、1和3 mg/L以下,对土霉素的平均去除率分别达到64%、72%和75%;研究还发现固定化膜生物反应器对进水中氨氮的波动具有良好的抗冲击负荷能力且可以延缓膜污染,正确调整水处理工艺的运行工序可以在提高水处理效率的同时有效降低水环境中的抗生素药物含量。  相似文献   

8.
养殖污水生物处理的新型流态化技术原理及其应用案例   总被引:1,自引:0,他引:1  
以COD、NH4+-N、SS值高以及臭味大的水质特征的养殖污水作为研究对象,针对一般处理模式中的生物反应器存在污泥相停留时间短、耐负荷冲击能力低、除碳与脱氮不能协调以及投资运行费用大等问题,自行研制了具有强化传质与混合功能的射流循环厌氧与气升循环好氧流态化反应器,实现了A/O2的组合生物强化工艺,再辅以预处理与后处理工艺,实践了规模为216 m3/d的工程设计与运行,通过连续6个月的运行数据来评价所提出工艺的工程效果。在A、O1与O2的运行负荷(kg COD/(m3.d))分别为6、6及0.5的近似条件下,当进水COD、BOD5、NH 4+-N和SS浓度分别为11 000~13 000、5 500~6 500、560~640和7 000~9 000 mg/L时,处理后出水浓度分别可降低至56.8~59.2、4.7~4.9、8.6~9.5和37.0~39.4 mg/L,各项指标均达到《广东省水污染物排放限值》(DB4426-2001)第2时段的一级排放标准限值要求,取得了明显的工程实效,表明所开发的技术有推广应用的价值。  相似文献   

9.
工业废铝渣制备聚合硫酸铝及其絮凝性能研究   总被引:1,自引:0,他引:1  
以一家金属材料厂生产过程中产生的废铝渣作为研究对象,通过对溶解条件和聚合工艺的优化,制备了聚合硫酸铝。将制备的聚合硫酸铝分别用于模拟浊度水及高色度高浓度有机工业废水的处理,实验结果表明,利用工业废渣所制得的聚合硫酸铝具有较好的除浊、脱色、去除COD效果。此工艺不仅可回收利用废铝渣,又可省去废渣处置费用,为废铝渣的综合利用提供了实用技术。  相似文献   

10.
The microscopic green alga, Chlorella pyrenoidosa was grown in settled and activated sewage under two different culture systems, batch and semi-continuous. Good growth was obtained in both types of wastewater and the algal production was comparable to and even higher than that found in commercial Bristol medium. The semi-continuous culture supported more growth than the batch system. There was a close relationship between algal growth and the amount of nutrient removed from both settled and activated sewage. A more rapid drop in NH(4)(+)-N was found in settle rather than activated sewage. The NH(4)(+)-N of settled sewage dropped from its initial 27 to 5 mg litre(-1) in both culture systems. On the other hand, the NO(3)(-)-N of activated sewage started to decrease from Day 2 onwards and the final NO(3)(-)-N concentration was less than 1 mg litre(-1) (over 90% removal efficiency). The amount of total inorganic nitrogen being reduced due to algal culture was similar in both types of sewage. The changes of phosphate content followed the same trend in both sewage, the P concentration increased slightly in the first two days then decreased, especially in the semi-continuous cultures. The final ortho-P in the sewage treated by Chlorella in semi-continuous culture was less than 5 mg litre(-1) (about 62% reduction). Such removal efficiency was slightly lower than those reported in previous studies. In general, the semi-continuous algal culture appeared to be a more suitable and efficient way for wastewater treatment than the batch system. With respect to the total reduction of wastewater inorganic N and P by means of Chlorella cells, there was no significant difference between settled and activated sewage.  相似文献   

11.
The performance of an innovative membrane bioreactor (MBR) process using anoxic phosphorus uptake with nitrification and denitrification for the treatment of municipal wastewater with respect to operational performance and effluent quality is addressed in this paper. The system was operated at steady-state conditions with a synthetic acetate-based wastewater at a hydraulic retention time (HRT) of 12 hours and on degritted municipal wastewater at a total system HRT of 6 hours. The MBR system was able to achieve 99% biochemical oxygen demand (BOD), chemical oxygen demand (COD), and ammonia-nitrogen (NH4(+)-N); 98% total Kjeldahl nitrogen (TKN); and 97% phosphorus removal, producing effluent BOD, COD, NH4+-N, TKN, nitrate-nitrogen, nitrite-nitrogen, and phosphate-phosphorus of <3, 14, 0.2, 0.26, 5.8, 0.21, and <0.01 mg/L, respectively, at the 6-hour HRT. The comparison of the synthetic and municipal wastewater run is presented in this paper. Steady-state mass balance on municipal wastewater was performed to reveal some key features of the modified MBR system.  相似文献   

12.
通过管道实验和明渠实验模拟尾水输送过程,研究不同输送方案对尾水中COD、BOD5、SS、TN、氨氮、TP、DO、雌酮(E1)、辛基酚(OP)、壬基酚(4-n-NP)等指标的去除规律,为徐州市截污导流工程尾水输送方案的选取提供理论依据.结果表明:(1)除DO、TP和SS外,管道输送方案对其他指标的控制能力均优于明渠;管道输送过程中,除SS和TN外,污染物的浓度变化主要发生在0~48 h.(2)在选择管道输送方案的基础上,可以考虑在实际输送时提高流速,缩短尾水在管道中的停留时间.  相似文献   

13.
厌氧池-复合型人工湿地系统污水处理效果的季节变化   总被引:2,自引:1,他引:1  
利用厌氧池-复合型人工湿地(AT-ICW)系统处理农村生活污水,探讨工艺系统不同季节对污水的处理效果。结果表明,该工艺系统春、夏、秋季对氨氮(NH4+-N)、总磷(TP)表现出稳定且较好的去除效果,去除率分别为92.8%~97.0%和56.4%~65.9%,冬季去除率相对较差,平均去除率分别为67.1%和42.5%。NO3--N的去除效果差,四季均出现积累,累积率达到71.5%~342.9%。系统春、夏季对总氮(TN)去除效果较好,去除率为57.3%~68.9%,秋、冬季去除效果相对较差,为24.5%~35.8%。系统夏季COD去除效果好,平均去除率达到78.3%,冬、春季去除效果较差,为37.8%~43.5%。各项污水排放指标均达到城镇污水处理厂污染物排放一级A类标准。AT-ICW系统不仅处理效果好,而且运行费用低,适用于农村分散型生活污水处理。  相似文献   

14.
低温环境下内置腐殖土填料SBR系统处理糠醛废水   总被引:1,自引:0,他引:1  
在水温为5~10℃左右的条件下,通过实验对比了传统SBR系统与内置腐殖土填料式SBR系统处理糠醛废水的效能,结果表明:由于内置腐殖土填料的作用,填料式SBR系统的去除效能要高于未装填料的SBR系统;传统SBR系统的COD、氨氮和总氮的去除率分别为89%、85%和59%,出水浊度为8.6 NTU;填料式SBR系统的COD、氨氮和总氮的去除率分别为95%、90%和71%,出水浊度为1.7 NTU。  相似文献   

15.
组合人工湿地处理工业园区污水厂尾水的中试研究   总被引:3,自引:0,他引:3  
杨林  李咏梅 《环境工程学报》2012,6(6):1846-1850
在巢湖流域水环境治理中,依托工业园区污水厂,进行了组合人工湿地处理工业园区污水厂尾水的中试研究。介绍了工艺流程和设计参数,运行结果表明,整个处理系统运行稳定,对COD、NH4+-N和TP的平均去除率分别为65.5%、75.5%和49.2%,其中一级潜流湿地对各污染物的去除贡献率最高。系统出水COD、氨氮、总磷基本达到了《地表水环境质量标准》(GB3838-2002)中的Ⅴ类水标准。此外还利用GC/MS初步对系统进出水进行了有机物组分分析,结果表明尾水中含有除草剂及农药中间体等难降解有机物,组合人工湿地对这些物质有一定去除效果。  相似文献   

16.
Constant magnetic field (CMF) was investigated for its potential to intensify chemical oxygen demand (COD) removal in wastewater when applied with a generalized Fenton reaction. Various types of industrial and domestic wastewater were tested in the experiment. A significant dependence was observed between the wastewater type, dose of reacting substances, time of exposure to CMF, effectiveness of COD removal, and the rate of the advanced oxidation process. The use of CMF resulted in the improvement of the treatment process; however, the efficiency depended to a great extent on the type of wastewater and characteristics of the contained organic matter. Domestic wastewater seemed to be most amenable to the applied treatment (82% COD reduction). The least reduction in COD occurred for wood industry wastewater. In the analyzed wastewater, intense oxidation was observed during the first 60 minutes of the process. Longer reaction time did not increase COD reduction, with the exception of wood industry wastewater. The experiment revealed the possibility of applying smaller doses of the Fenton's reagent, thereby keeping up unchanged treatment efficiency, provided that CMFs are applied.  相似文献   

17.
微絮凝 -直接过滤工艺是一种将混凝反应、沉淀截留集中在同一滤柱内同步完成的高效水处理工艺。该工艺应用于城市污水的深度处理中 ,通过絮凝剂的加入 ,具有同步去除PO3 -4 P、SS和部分COD的功能。本文研究了该工艺对二级处理出水中PO3 -4 P、SS和COD的去除效果及其规律。研究表明 :采用聚合氯化铁 (PFC)作为絮凝剂 ,当Fe/P摩尔比为 2∶1时 ,水中PO3 -4 P的去除率达 98.8% ,浓度可降至 0 .1mg/L以下 ,同时SS、COD去除率也有明显提高。与传统的混凝、沉淀除磷工艺相比 ,该工艺具有操作简单、结构紧凑、占地面积小、污泥量少等优点 ,是一种更为经济和简单的处理单元 ,适用于现有城市污水处理厂的除磷和进一步提高水质的深度处理  相似文献   

18.
悬浮填料生物膜床反应器处理高校生活污水   总被引:1,自引:0,他引:1  
本研究利用悬浮填料生物膜床反应器处理高校生活污水 ,对CODCr、氨氮和总磷有较好的去除效果。水力停留时间 6h时 ,CODCr总去除率最高可达到 95 % ,出水CODCr稳定在 30mg/L以下 ;总磷去除率达到 5 0 %以上 ,出水总磷含量低于 0 5mg/L ;对NH3 N的去除率可以稳定在 80 %以上 ,出水NH3 N低于 1mg/L。  相似文献   

19.
针对城镇分散型污水处理的特点,开发了一种清洁型一体化污水处理系统.该系统由立体循环一体化氧化沟(IODVC)、污泥减量区和臭气处理区优化整合而成.中试试验结果表明:该系统可以使微生物有效处理污水,并实现污泥减量和臭味气体净化.经该系统处理的污水,出水COD、NH4 -N、SS的浓度维持在35 mg/L、1 mg/L和20 mg/L以下;同时,臭味气体得到有效去除,氨气和硫化氢等臭味气体可以达标排放;经过生物减量,排放的剩余污泥减少了46.4%;污泥的比阻有所降低.本系统占地少,运行操作简便,无二次污染,属于适合中小型污水处理的技术工艺.  相似文献   

20.
蚯蚓生态滤池对农村生活污水的深度净化效果   总被引:1,自引:0,他引:1  
本实验利用多级蚯蚓生态滤池对农村生活污水进行处理研究,分别考察了不同季节蚯蚓生态滤池对COD、TN、NH4+-N和TP的去除效果,同时利用PCR-DGGE技术对不同季节的微生物群落进行初步分析。结果表明,夏季COD、TN、NH4+-N和TP的平均去除率分别达到86.05%、89.02%、98.48%和99.1%;出水浓度17.86、4.96、0.605和0.047 mg/L。冬季COD、TN、NH4+-N和TP的平均去除率分别达到83.29%、93.26%、96.96%和92.7%;出水浓度22.68、2.63、1.02和0.37 mg/L。不同季节出水水质均达到了《城镇污水处理厂污染物排放标准》(GB18918-2002)一级A类标准。蚯蚓生态滤池内的微生物多样性冬季的要比夏季的丰富,且冬季滤池内微生物种类从上至下逐渐增加,符合污染物去除效率的变化。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏