首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
生活垃圾安全无害化处理是目前迫切需要解决的问题,直接气化熔融焚烧垃圾技术以降低二恶英排放方面巨大优势得到广泛关注,在此基础上提出纯氧熔融焚烧垃圾技术,几乎可以实现所有二次污染物近零排放。以350 t/d回转窑垃圾焚烧炉为例,对纯氧代替空气应用在回转窑上熔融焚烧垃圾系统进行了详细热力计算及分析。结果表明,纯氧熔融焚烧垃圾系统的锅炉效率可达90.56%,回转窑熔融焚烧系统还可以在垃圾焚烧后灰渣达到熔融温度的条件下,保持该系统热量平衡,稳定燃烧。并参考回转窑设计标准对该纯氧熔融焚烧城市生活垃圾的回转窑参数进行确定。  相似文献   

2.
Formation, release and control of dioxins in cement kilns   总被引:2,自引:1,他引:1  
Karstensen KH 《Chemosphere》2008,70(4):543-560
Co-processing of hazardous wastes in cement kilns have for decades been thought to cause increased emissions of PCDD/PCDFs--a perception that has been evaluated in this study. Hundreds of PCDD/PCDF measurements conducted by the cement industry and others in the last few years, on emissions and solid materials, as well as recent test burns with hazardous wastes in developing countries do not support this perception. Newer data has been compared with older literature data and shows in particular that many emission factors have to be reconsidered. Early emission factors for cement kilns co-processing hazardous waste, which are still used in inventories, are shown to be too high compared with actual measurements. Less than 10 years ago it was believed that the cement industry was the main contributor of PCDD/PCDFs to air; data collected in this study indicates however that the industry contributes with less than 1% of total emissions to air. The Stockholm Convention on POPs presently ratified by 144 parties, classifies cement kilns co-processing hazardous waste as a source category having the potential for comparatively high formation and release of PCDD/PCDFs. This classification is based on early investigations from the 1980s and 1990s where kilns co-processing hazardous waste had higher emissions compared to those that did not burn hazardous waste. However, the testing of these kilns was often done under worst case scenario conditions known to favour PCDD/PCDF formation. More than 2000 PCDD/PCDF cement kiln measurements have been evaluated in this study, representing most production technologies and waste feeding scenarios. They generally indicate that most modern cement kilns co-processing waste today can meet an emission level of 0.1ngI-TEQ/m(3), when well managed and operated. In these cases, proper and responsible use of waste including organic hazardous waste to replace parts of the fossil fuel does not seem to increase formation of PCDD/PCDFs. Modern preheater/precalciner kilns generally seems to have lower emissions than older wet-process cement kilns. It seems that the main factors stimulating formation of PCDD/PCDFs is the availability of organics in the raw material and the temperature of the air pollution control device. Feeding of materials containing elevated concentrations of organics as part of raw-material-mix should therefore be avoided and the exhaust gases should be cooled down quickly in long wet and long dry cement kilns without preheating. PCDD/PCDFs could be detected in all types of solid samples analysed: raw meal, pellets and slurry; alternative raw materials as sand, chalk and different ashes; cement kiln dust, clinker and cement. The concentrations are however generally low, similar to soil and sediment.  相似文献   

3.
Steps towards a European dioxin emission inventory   总被引:7,自引:0,他引:7  
Quass U  Fermann MW  Bröker G 《Chemosphere》2000,40(9-11):1125-1129
The results of a project aiming at collection and evaluation of information regarding the industrial and non-industrial emission sources for dioxins and furans (PCDD/PCDF) in 17 European Countries (EU 15, CH, N) are presented. An overview about national documents covering dioxin emission inventories for the period 1990-1995 is given. Some data on emissions associated with residual materials, waste and waste water are presented additionally. Based on the air emission data contained in these documents the most important emission sources were determined which are assumed to cover about 90% of the overall emissions. For the selected sources and for all 17 countries new estimates of the atmospheric PCDD/PCDF emissions were derived from average emission factors and statistical activity rates for the year 1994. As a result, on the European scale the largest annual PCDD/PCDF emission is assessed to be released from municipal waste incineration, quite closely followed by emissions from iron ore sintering. Considerable releases of dioxins and furans--based, however, on highly uncertain data--are further assessed for domestic burning, accidental fires and (former) use of contaminated wood preservatives (pentachlorophenol). A lower but still significant emission is further assigned to the sector of non-ferrous metal production; particular processes used in this branch proved to generate very high PCDD/PCDF flue gas concentrations.  相似文献   

4.
Modeling the formation of PCDD/F in solid waste incinerators   总被引:1,自引:0,他引:1  
Stanmore BR 《Chemosphere》2002,47(6):565-573
Polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/F) appear in unacceptable amounts in the gaseous emissions during the incineration of wastes containing significant quantities of chlorine and metals, such as MSW and medical waste. They are formed both in the gas phase at temperatures above 600 degrees C and on the surface of the solid phase (flyash) in the temperature range 400-225 degrees C. Both the precursor (from existing smaller chlorinated molecules) and de novo (from elemental carbon) routes are involved. An empirically derived global model for their de novo formation on flyash in MSW and medical waste incinerators has now been extended to include the precursor mechanism, and a gas phase formation component, with separate rate expressions for PCDD and PCDF. Homogeneous PCDD formation is governed by the concentration of chlorophenols and PCDF by that of chlorophenols and chlorobenzenes. The result is more complete system which distinguishes between the gas and solid phase contributions to the I-TEQ. An additional step for the adsorption of gaseous PCDD/F back onto the solid phase during cooling suggests this should be minimal in the gas ducts of an incinerator. The extended model has been tested against experimental data collected from a well-controlled pilot incinerator and commercial incinerators, and found to adequately describe the measured outputs. With the model it should be possible to predict the PCDD/F emissions from commercial incinerators, provided that the ash properties and the overall temperature-time profiles are known.  相似文献   

5.
This study characterized the emissions of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) from the stack flue gases of 17 industrial sources, which were classified into 10 categories. The results show that the mean PCDD/PCDF concentration of secondary zinc smelter (Zn-S) and secondary copper smelter (Cu-S) is 2.44 ng international toxic equivalent (I-TEQ)/Nm3 (N represents normal conditions at 0 degrees C, 760 mmHg), which was found to be significantly greater than that of industrial waste incinerators (mean concentration = 0.15 ng I-TEQ/Nm3). These results imply that the controlling of secondary metallurgical melting processes is more important than industrial waste incineration for the reduction of PCDD/PCDF emissions. The mean emission factors of cement production, Zn-S and Cu-S, are 0.052, 1.99, and 1.73 microg I-TEQ/t product, respectively. For industrial waste incineration, the mean emission factors of waste rubber, waste liquor, waste sludge, industrial waste solid (IWI)-1, IWI-2, IWI-3, and IWI-4 are 0.752, 0.435, 0.760, 6.64, 1.67, 2.38, and 0.094 microg I-TEQ/t feed, respectively. Most of the PCDD/PCDF emission factors established in this study are less than those reported in previous studies, which could be because of the more stringent regulations for PCDD/PCDF emissions in recent years.  相似文献   

6.
Abstract

This study characterized the emissions of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) from the stack flue gases of 17 industrial sources, which were classified into 10 categories. The results show that the mean PCDD/PCDF concentration of secondary zinc smelter (Zn-S) and secondary copper smelter (Cu-S) is 2.44 ng international toxic equivalent (I-TEQ)/Nm3 (N represents normal conditions at 0 °C, 760 mmHg), which was found to be significantly greater than that of industrial waste incinerators (mean concentration = 0.15 ng I-TEQ/Nm3). These results imply that the controlling of secondary metallurgical melting processes is more important than industrial waste incineration for the reduction of PCDD/PCDF emissions. The mean emission factors of cement production, Zn-S and Cu-S, are 0.052, 1.99, and 1.73 μg I-TEQ/t product, respectively. For industrial waste incineration, the mean emission factors of waste rubber, waste liquor, waste sludge, industrial waste solid (IWI)-1, IWI-2, IWI-3, and IWI-4 are 0.752, 0.435, 0.760, 6.64, 1.67, 2.38, and 0.094 μg I-TEQ/t feed, respectively. Most of the PCDD/PCDF emission factors established in this study are less than those reported in previous studies, which could be because of the more stringent regulations for PCDD/PCDF emissions in recent years.  相似文献   

7.
An external monitoring plan (EMP) is being implemented in the region of Oporto, Portugal, to follow the potential effects of a future incinerator of municipal solid waste. Polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/PCDF) were measured during 1998 and the first semester of 1999, prior to the working up of the incineration unit. The baseline levels obtained through this intensive monitoring work are presented and discussed in the present paper.  相似文献   

8.
Experimental data on PCDD and PCDF emissions in raw gases from municipal solid waste combustion in a pilot plant were processed by Response Surface models to gain information on process parameter values which minimize both the total PCDD/PCDF concentrations and those of a selected congener group.  相似文献   

9.
In this paper results of various measurement campaigns at different municipal waste incineration (MWI) plants concerning the change of the PCDD/PCDF isomer distribution in the crude gas during transiently impaired combustion conditions are presented. The focus is on the Cl4DD isomer distributions exemplarily for all other homologue groups to demonstrate the change in PCDD/PCDF formation mechanism at transient combustion conditions. Additionally to crude gas samples, at one plant filter and boiler ash were investigated simultaneously to determine if there is any difference in the isomer distribution between the matrices. For the ash from an electrostatic precipitator (ESP ash), the boiler ash and the corresponding crude gas sample, nearly identical changes in the Cl4DD isomer distribution under transient combustion conditions in relation to the normal operation process could be detected. By comparing the Cl4DD isomer distributions from different incineration plants (two municipal waste incinerators and one little incinerator burning wood chips for heating domestic household) under transient combustion conditions, in all cases the 1,3,6,8- and 1,3,7,9-Cl4DD were dominating the isomer distribution, whereas under normal operation other isomers were predominant. Obviously PCDD/PCDF formation mechanisms under transient combustion conditions are independent from the type of incinerator and of the burned fuel, respectively. Data sets were analyzed with respect to the possible reaction mechanism via chlorophenols and a good correlation of 2,4,6-trichlorophenol during the second phase of a start-up process and during a CO experiment was found. To get more detailed information about possible formation mechanisms, at one plant the dependence of the PCDD/PCDF isomer distribution on the different matrices was studied. Separate analysis of fly ash collected at the boiler exit, subsequent gas phase, ESP ash and boiler ash under normal operation conditions showed that, apart from the fly ash, the Cl4DD isomer distributions are nearly the same in the different matrices. Surprisingly, the Cl4DD isomer distribution of the fly ash was more similar to the distributions found under transient combustion conditions.  相似文献   

10.
Mechanisms that have been proposed to account for the emission of PCDD/PCDF from municipal waste incinerators were evaluated in the light of extensive experimental data obtained from the Quebec City municipal solid waste incinerator by Environment Canada. It was found that PCDD/PCDF emissions were closely related to the quantity of material entrained by the combustion gases.  相似文献   

11.
Cunliffe AM  Williams PT 《Chemosphere》2007,68(9):1723-1732
The influence of temperature on the levels of PCDD and PCDF remaining in, and desorbed from, a municipal solid waste incinerator flyash was investigated by heating the ash to between 200 and 400 degrees C under a simulated flue gas for four days reaction time. Considerable desorption of PCDD/PCDF from the flyash was seen at 275 degrees C and above. Maximum desorption occurred at 350 degrees C, with the equivalent of nearly eight times the total PCDD/PCDF concentration of the original flyash being lost to the vapour phase per unit mass of initial flyash. The I-TEQ value of the desorbed PCDD/PCDF was considerable, being over fourteen times that of the original flyash at 325 degrees C. The results indicate that formation of PCDD/PCDF on flyash deposits in the post-combustion plant of incinerators can result in the release of significant amounts of PCDD/PCDF to the flue gas stream.  相似文献   

12.
Significant dioxin (polychlorinated dibenzo-para-dioxins (PCDDs)/polychlorinated dibenzo-furans (PCDFs)) pollution from a municipal solid waste incinerator was discovered in 1997 in Osaka prefecture/Japan. The cause and mechanism of pollution was identified by a detailed assessment of the environment and incinerator plant. The primary sources of PCDD/PCDF pollution were high dioxin releases from an intermittently operated waste incinerator with PCDD/PCDF emissions of 150 ng-TEQ/Nm3. PCDD/PCDF also accumulated in the wet scrubber system (3,000 μg TEQ/L) by adsorption and water recirculation in the incinerator. Scrubber water was air-cooled with a cooling tower located on the roof of the incinerator. High concentrations of dioxins in the cooling water were released as aerosols into the surrounding and caused heavy soil pollution in the area near the plant. These emissions were considered as the major contamination pathway from the plant. Decontamination and soil remediation in and around the incinerator plant were conducted using a variety of destruction technologies (including incineration, photochemical degradation and GeoMelt technology). Although the soil remediation process was successfully finished in December 2006 about 3 % of the waste still remains. The case demonstrates that releases from incinerators which do not use best available technology or which are not operated according to best environmental practices can contaminate their operators and surrounding land. This significant pollution had a large impact on the Japanese government’s approach toward controlling dioxin pollution. Since this incident, a ministerial conference on dioxins has successfully strengthened control measures.  相似文献   

13.
The effect of reaction time on formation of polychlorinated dibenzo-p-dioxins (PCDD) and dibenzofurans (PCDF) was studied under laboratory conditions in the system containing municipal waste incineration fly ash, activated carbon and copper chloride dihydrate at 300 degrees C in 99.999% N2 and N2 + 10% O2 atmosphere. The concentrations of tetra- to octa-chlorinated isomers as well as I-TEQ concentrations of toxic congeners are reported. The mechanism of PCDD and PCDF formation from chlorophenols and chlorinated biphenyls is discussed in the light of the time changes of PCDD/PCDF ratios.  相似文献   

14.
This article Introduces a technology for the simultaneous control of the emissions of PCDD/ PCDF, hydrochloric acid (HCI) and nitrogen oxides (NOx) from municipal solid waste (MSW) Incinerators. The technology uses ammonia as the control medium for all three pollutants. In this paper, the theoretical basis of the technology Is discussed. In addition, a bench-scale experiment proving the theory Is described and the practical application of the theory Is presented. Finally, further steps which are being taken to develop the technology for commercial application are detailed.  相似文献   

15.
Anderson DR  Fisher R 《Chemosphere》2002,46(3):371-381
Several countries have compiled national inventories of dioxin (polychlorinated dibenzo-p-dioxin [PCDD] and polychlorinated dibenzofuran [PCDF]) releases that detail annual mass emission estimates for regulated sources. High temperature processes, such as commercial waste incineration and iron ore sintering used in the production of iron and steel, have been identified as point sources of dioxins. Other important releases of dioxins are from various diffuse sources such as bonfire burning and domestic heating. The PCDD/F inventory for emissions to air in the UK has decreased significantly from 1995 to 1998 because of reduced emissions from waste incinerators which now generally operate at waste gas stack emissions of 1 ng I-TEQ/Nm3 or below. The iron ore sintering process is the only noteworthy source of PCDD/Fs at integrated iron and steelworks operated by Corus (formerly British Steel plc) in the UK. The mean waste gas stack PCDD/F concentration for this process is 1,2 ng I-TEQ/Nm3 based on 94 measurements and it has been estimated that this results in an annual mass release of approximately 38 g I-TEQ per annum. Diffuse sources now form a major contribution to the UK inventory as PCDD/Fs from regulated sources have decreased, for example, the annual celebration of Bonfire Night on 5th November in the UK causes an estimated release of 30 g I-TEQ, similar to that emitted by five sinter plants in the UK.  相似文献   

16.
In laboratory-scale combustion of polyvinylidene chloride (PVDC) with a quartz tubular furnace designed and fabricated to provide the desired combustion temperature and mixing state of combustion gas with air, it was found that at 800 degrees C or higher the level of polychlorinated dibenzo-p-dioxins/polychlorinated dibenzofurans [corrected] (PCDDs/PCDFs) resulting from PVDC combustion was no higher than that from heating air alone, and thus far below the levels which resulted from PVDC combustion at 750 degrees C or lower. The results provide the first laboratory confirmation of the relation between PVDC incineration temperature and PCDD/PCDF formation, and of the primary importance of high temperature, turbulence for mixing between air and combustion gas, and sufficient residence time, as governing factors for the minimization of PCDD/PCDF formation in municipal solid waste incinerators.  相似文献   

17.
Wu HL  Lu SY  Yan JH  Li XD  Chen T 《Chemosphere》2011,84(3):361-367
The fly ash used in this study was collected from a bag filter in a medical waste rotary kiln incineration system, using lime and activated carbon injection followed by their collection as mixed fly ash. Experiments were conducted on fly ash in a quartz tube, heated in a laboratory-scale horizontal tube furnace, in order to study the effect of temperature and nitrogen flow rate on the removal of PCDD/Fs. Results indicated that in this study PCDD/Fs in the fly ash mostly were removed and desorbed very little into the flue gas under thermal treatment especially when the heating temperature was higher than 350 °C, and dechlorination and destruction reactions took important part in the removal of PCDD/Fs. However, in terms of flow rate, when flow rate was higher than 4 cm s−1, destruction efficiency of PCDD/Fs decreased dramatically and the main contributors were P5CDF, H6CDF and H7CDF desorbed to flue gas, the PCDD/Fs in the fly ash decreased with enhanced flow rate.  相似文献   

18.
In 1997, the Polychlorinated dibenzo-para-dioxin (PCDD)/Polychlorinated dibenzofuran (PCDF) concentrations in dairy products in Germany and other European countries increased. The PCDD/PCDF source was contaminated lime used in Brazilian citrus pulp pellets. The contaminated lime was mined from an industrial dump site. However, the detailed origin of the PCDD/PCDFs in the lime was not revealed. This paper investigates the contamination origin and describes the link between lime milk from the dumpsite of a chlorine/organochlorine industry and the contaminated lime. The contaminated lime stem from mining at the corporate landfill of Solvay Indupa in Sao Paulo. The landfill was used for 40 years for deposition of production residues and closed in 1996. The factory operated/operates at least two processes with potentially high PCDD/PCDFs releases namely the oxychlorination process for production of ethylene dichloride (EDC) and the chlor-alkali process. The main landfilled waste was lime milk (1.4 million tons) from the vinyl chloride monomer production (via the acetylene process) along with residues from other processes. The PCDD/PCDF fingerprint revealed that most samples from the chemical landfill showed an EDC PCDD/PCDF pattern with a characteristic octachlorodibenzofuran dominance. The PCDD/PCDF pattern of a Rio Grande sediment samples downstream the facility showed a chlor-alkali pattern with a minor impact of the EDC pattern. The case highlights that PCDD/PCDF- and persistent organic pollutants-contaminated sites need to be identified in a comprehensive manner as required by the Stockholm Convention (article 6) and controlled for their impact on the environment and human health. Landfill mining and reuse of materials from contaminated deposits should be prohibited.  相似文献   

19.
After entry into force of the Stockholm Convention and Aarhus Protocol and in order to implement the upcoming European legal background, the European countries are asked to apply control measures to reduce the release of persistent organic pollutants (POPs) such as dioxins and furans (PCDD/PCDF) and polychlorinated biphenyls as well as to establish POPs release inventories. In this perspective, development of measuring techniques of emissions is a focal issue in acquiring useful information. In this paper, results of various measurement campaigns at different municipal waste incineration (MWI) plants using long-term automated sampling of PCDD/PCDF are presented. The samples collected from both manual and automated campaigns were analyzed following the European Standard EN-1948:2006 by high-resolution gas chromatograph/high-resolution mass spectrometer. Performances of two different commercial systems have been investigated. Anomalous values occurred during one long-term campaign (22.16 pg I-toxic equivalent (TEQ)/Nm(3)), compared to average values (4-5 pg I-TEQ/Nm(3)) of the MWI. At this maximum value, a main occurrence of abnormal and instable operating conditions has been found. Sampling based on long-term basis was found to be more reliable to monitor PCDD/PCDF emissions than occasional short-term sampling. Nevertheless, the results of long-term campaigns demonstrate that emission levels detected in 15-30 days campaigns, when unsteady operating conditions can occur, as start-up and shut down, are not immediately comparable to the typical levels in a 6-8 h, when operating conditions are generally stable. Moreover, there are often differences observed in the congener profiles between short- and long-term campaigns.  相似文献   

20.
ABSTRACT

Emissions of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) from municipal waste incineration have been widely studied because of their extensive toxicity, and many efforts have been made to restrict their emissions. Although a number of chemical compounds have been shown in laboratory-scale tests to inhibit the formation of PCDD/Fs, few have been tested in pilot- or full-scale plants. This work evaluates the effect of urea as a PCDD/F inhibitor in a pilot-scale incinerator that uses refuse-derived fuel (RDF). The decomposition of urea under the test conditions was also studied using detailed kinetic modeling. An aqueous solution of urea was injected into the flue gas stream after the furnace at ~730 °C, with varied urea concentrations and flue gas residence times used between the furnace and the sampling point. The results demonstrate that urea can successfully inhibit PCDD/F formation in waste incineration if concentrations and injection points are properly adjusted. The kinetic model showed that urea can be rapidly decomposed under appropriate flue gas conditions, indicating that in addition to the urea molecule itself, decomposition products of urea can also be responsible for the reduction of PCDD/F production during incineration.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号