多级A/OVTBR组合工艺处理焦化废水   总被引:2,自引:0,他引:2  
采用水解酸化、多级A/O垂直折流生物膜反应器(vertical tubulant biological reactor,VTBR)、混凝和Fenton氧化组合技术对实际焦化废水进行处理。其中水解酸化预处理阶段提高了废水可生化性,混凝降低了生化处理的有机负荷,一级A/O VTBR以脱碳为主,二级A/O VTBR主要脱碳和脱氮,三级好氧VTBR强化对氨氮的去除,Fenton氧化则对生化出水进行深度处理。试验结果表明:在进水ρ(COD)为3 000~3 500 mg/L,ρ(BOD5)为1 212 mg/L,ρ(NH3-N)为109 mg/L条件下,保持好氧段ρ(DO)为3~7 mg/L,缺氧段ρ(DO)<1 mg/L,总停留时间HRT 56 h,该工艺对COD、BOD5、NH3-N的去除率分别为98%、99%、95%,出水达GB8978-1996《污水综合排放标准》中的一级排放标准。  相似文献   

2.
翟建  鲁秀国 《环境工程》2010,28(2):13-16
介绍了水解酸化-UBF-接触氧化组合工艺处理聚醚多元醇生产污水的工艺设计和运行效果。经一段时间的调试及运行表明:该工艺处理聚醚多元醇生产综合污水是切实可行的。在进水ρ(COD)为8000~12000mg/L,ρ(BOD5)为1200~1500mg/L的条件下,经过该工艺处理,出水ρ(COD)为250~300mg/L,ρ(BOD5)在50~80mg/L以下,出水水质达GB8978-1996《污水综合排放标准》Ⅲ级。  相似文献   

3.
针对规模化猪场粪污特点,以实际工程为例,介绍了"干湿分离,生物制肥,厌氧+A2/O+UF+光催化组合工艺处理废水"的设计及其运行情况。结果表明:该工艺对废水中COD、BOD5、TP和NH3-N去除率分别达98.75%、98.34%、96.67%和95.21%,出水水质能够稳定在ρ(COD)为63.282.32 mg/L、ρ(BOD5)为31.282.32 mg/L、ρ(BOD5)为31.243.2 mg/L、ρ(TP)为1.543.2 mg/L、ρ(TP)为1.52.5 mg/L、ρ(NH3-N)为11.22.5 mg/L、ρ(NH3-N)为11.218.4 mg/L。出水水质满足GB 5084—2005《农田灌溉水质标准》,处理后的水可全部用于厂区农业灌溉;生物制肥工艺运行稳定,年产有机肥2600 t,利润50余万元。粪污治理工程综合效益好,可供同类工程参考。  相似文献   

4.
化妆品生产废水处理工程设计与调试实例   总被引:3,自引:0,他引:3  
采用“水解酸化-接触氧化”组合工艺处理高浓度日用化工废水,同时以曝气生物滤池工艺进行深度处理,进一步提高废水处理效率。经过系统处理,废水CODCr从进水4000mg/L左右降为80mg/L以下,BOD5从进水1100mg/L左右降为20mg/L以下,处理效率均达到98%,排放水质完全达到广州市污水排放一级标准(DB4437-90)。通过工程的长期实际运行表明,该系统处理的出水水质稳定,处理效率高。  相似文献   

5.
针对某化工厂液晶中间体生产废水,采用Fenton预处理+水解酸化+好氧+超滤反渗透工艺进行处理,发现Fenton技术具有良好的预处理效果,对COD的去除率在50%左右,且废水可生化性从原水的0.05提高至0.38,经过水解酸化及好氧单元的降解,废水ρ(COD)可降至150~200 mg/L,再通过超滤反渗透膜处理,COD浓度可降至50mg/L以下,达到GB/T 19923—2005《城市污水再生利用—工业用水水质》要求,出水可用作稀释水或厂内冷却用水。膜浓水通过自主研发的强化蒸发装置处理,可实现废水不外排。采用该工艺对厂内实际生产废水进行现场调试运行,处理规模为5 m~3/d,原水初始pH值为2.0~4.5,ρ(COD)为7 000~10 000 mg/L。稳定运行后,生化段出水pH值为7.5~8.0;ρ(COD)为150~200 mg/L,膜处理后ρ(COD)<50 mg/L,证明运行稳定可靠。  相似文献   

6.
水解酸化-多级接触氧化工艺处理大蒜废水   总被引:2,自引:1,他引:1  
介绍了水解酸化-多级接触氧化工艺在处理大蒜废水中的应用。运行结果表明:进水ρ(COD)=800~1 000 mg/L,ρ(BOD5)=300~500 mg/L,ρ(SS)=200~300 mg/L,时,出水ρ(COD)、ρ(BOD5)、ρ(SS)分别为56,19,22 mg/L。系统出水达到GB8978-96《污水综合排放标准》一级排放标准。  相似文献   

7.
根据食品添加剂废水水质变化大,成分复杂特点,提出了"水解酸化—接触氧化—臭氧催化氧化—曝气生物滤池(BAF)"的组合工艺。废水COD从进水2000~7000mg/L降到100mg/L以下,最低为33mg/L,排放水质达到国家排放标准。水解酸化系统使废水平均COD从5290mg/L降到2323mg/L,并使大颗粒难降解分子部分转化为小颗粒可降解分子,为后续的接触氧化系统处理提供良好的条件,接触氧化出水平均COD为268mg/L。接触氧化出水含较多难生物降解有机物,经O3氧化预处理后在COD下降45%的情况下其BOD5/COD由0.3升为0.44,更易于生化降解。废水经曝气生物滤池平均出水COD为66mg/L。中试研究表明,水解酸化系统和臭氧催化氧化(负载MnO2的陶粒为催化剂)-曝气生物滤池深度处理系统是该工艺处理高浓度废水稳定达标的关键。  相似文献   

8.
水解酸化-反硝化-硝化组合工艺处理土霉素废水的效果   总被引:7,自引:0,他引:7  
采用水解酸化 反硝化 硝化的组合工艺对土霉素废水进行实验室规模连续处理 ,水解酸化和反硝化均采用上向流污泥床 ,硝化采用2个使用不同填料的生物膜反应器 ,稳定运行 70d .当进水COD和NH4+-N浓度分别为2200~3000mg/L和400~460mg/L时 ,该系统在总水力停留时间为56h的条件下 ,稳定实现80%以上的COD和TN去除率 .生物处理出水经48mg/L聚合硫酸铁(以铁计)处理后COD降至293mg/L,实现了废水的达标排放.  相似文献   

9.
采用水解酸化与Fenton试剂分别处理高浓度抗生素化学合成废水的厌氧出水,并采用MBR验证其生化性的改善。试验表明:在废水ρ(COD)平均为4 084 mg/L时,水解酸化COD去除率平均为26.2%,ρ(BOD5)/ρ(COD)从0.23提高到0.31,但无法保证MBR出水ρ(COD)<120 mg/L。Fenton试剂反应条件为:ρ(H2O2)=5 000 mg/L,ρ(Fe2+)=4 000 mg/L,pH=7,反应时间1 h,COD去除率达50%。混合废水经MBR处理后,出水ρ(COD)平均为98.4 mg/L,可稳定达《制药工业水污染物排放标准》。  相似文献   

10.
O_3-MBR法深度处理煤气废水   总被引:3,自引:0,他引:3  
以经多级生物处理后的煤气废水为原水,采用O3-MBR组合工艺对其进行深度处理,以满足回用要求.结果表明:采用臭氧氧化工艺,当废水pH为11和臭氧投加量〔ρ(臭氧)〕为189.2mg/L时,CODCr和色度的去除率分别为46.5%和80.2%,ρ(BOD5)/ρ(CODCr)由0.02升至0.29,废水的可生化性得到明显改善;臭氧氧化工艺出水再通过MBR作进一步处理,CODCr,NH3-N和色度的去除率分别达23.0%,76.3%和70.0%,且出水水质稳定;总体上,废水经O3-MBR组合工艺处理,CODCr,NH3-N,色度和浊度的平均总去除率分别达到58.7%,76.3%,88.6%和95.1%;处理后出水的ρ(CODCr)50mg/L,ρ(NH3-N)5mg/L,浊度0.2NTU,色度约为30度,出水水质满足生产工艺回用的要求.  相似文献   

11.
MBR处理微污染河水试验   总被引:1,自引:0,他引:1  
采用絮凝沉淀+缺氧/膜生物反应器(Anoxic/Membrane Bioreactor,A/MBR)工艺对劣Ⅴ类微污染河水的处理进行了中试研究,探讨了该工艺对低碳高氮磷河水处理效果的保证措施. 结果表明:系统处理规模为10 m3/d,在曝气量为8 m3/h,平流沉淀池、缺氧池和膜池水力停留时间分别为25 min,0.8 h和2.5 h,污泥ρ(MLSS)为6.0~6.5 g/L的运行条件下,向缺氧池投加约为理论量2倍的甲醇,在平流沉淀池与膜池分别投加10和5 mg/L的聚合氯化铝(PAC),出水ρ(CODCr),ρ(BOD5),ρ(NH3-N)和ρ(TP)达到《地表水环境质量标准》(GB3838—2002)Ⅲ类水体标准,ρ(TN)<15 mg/L.   相似文献   

12.
研究采用本课题组研发的亲电改性聚乙烯为悬浮生物膜载体,构建移动生物膜与活性污泥复合工艺(integrated free-floating biofilm and activated sludge,IFFAS),对东北某工业园区污水处理厂的污水处理进行现场中试。结果表明,当进水ρ(COD)、ρ(NH3-N)、ρ(TN)分别为139~741,19.3~44.9,29.6~148.6 mg/L时,改性载体在10 d左右即可完成挂膜;中试IFFAS工艺稳定运行阶段,出水COD、NH3-N、TN的平均去除率分别高达88%、97%、80%,出水浓度分别为36~48,0.1~0.9,5~14.3 mg/L,达到GB 18918—2002《城镇污水处理厂污染物排放标准》一级A排放标准。出水水质明显优于污水处理厂原有A2/O工艺出水,说明以亲电改性聚乙烯为载体的IFFAS工艺可显著提高净化污水的能力。  相似文献   

13.
An anaerobic/oxic membrane bioreactor (A/O MBR) was used for treatment of dyeing wastewater from a woolen mill.COD and color of the wastewater were 54-473 mg/L and 40-400 dilution time (DT) respectively. The ratio of BOD5/COD was less than 0.13. By the A/O MBR process, the average removal of COD, BOD5, color and turbidity was 82%, 96%, 71% and 99%, respectively. The average COD, BOD5, color and turbidity of effluent was 37 nag/L, 0.8 mg/L, 40 DT and 0.44 NUT respectively. The effluent COD met the local standard of reuse water in Beijing, China. The average COD volume load of the anaerobic biological tank was 0. 0483 kgCOD/(m3·d) and that of the aeration tank of the MBR was 0. 3589 kgCOD/(m3·d). The sludge load of the MBR was 0.19 kgCOD/(kg· MLSS· d) on average and the maximum of that was 0.4 kgCOD/( kg· MLSS· d).The flux of the A/O membrane bioreactor could be remained at larger than 50 L/(h· m2· 0.1MPa). The results indicated that A/O membrane bioreactor has technical feasibility for treatment of woolen mill wastewater.  相似文献   

14.
采用SAF-化学絮凝-微滤分离膜组合工艺对高浓度生活污水进行处理.SAF处理系统对污染物的去除效果良好,CODCr,BOD5,SS和NH4 -N的去除率分别为92%,93%,90%和98%.SAF生物处理系统的出水再经化学絮凝和微滤分离膜深度处理后,CODCr,BOD5,NH4 -N,PO43--P的浓度分别低于40 mg/L,10mg/L,4mg/L,0.3mg/L;浊度小于0.5NTU,色度小于10度.试验结果表明该组合工艺处理后的污水水质优良,可满足生活杂用和市政杂用.  相似文献   

15.
针对城市污水处理厂尾水的特点,采用生态氧化池/垂直流人工湿地/自然湿地生态工程组合工艺对其进行深度处理,重点分析了运行效果和去除机理。数据结果表明,该工艺运行稳定,系统出水COD,BOD5,NH3-N和TP平均分别为14.4,3.4,0.84,0.19mg/L,平均去除率均在65%以上,出水水质达到《地表水环境质量标准》(GB3838-2002)中Ⅳ类标准。  相似文献   

16.
Anaerobic ammonia oxidation(Anammox) process is a novel and promising wastewater nitrogen removal process. The feasibility of transition of Anammox from denitrification and the performance of lab-scale Anammox biofilm reactor were investigated with sludge dewatering effluent. The results showed that Anammox process could be successfully started up after cultivation of denitrification biofilm and using it as inoculum. The transition of Anammox from denitrification was accomplished within 85 d. Anammox process was found suitable to remove ammonia from sludge dewatering effluent. The effluent ammonia concentration was detected to be 23.11 mgN/L at HRT of 28 h when influent ammonia concentration was fed 245 mgN/L, which was less than that for the national discharge standard Ⅱ (25 rngN/L) of China. Volumetric total nitrogen loading rate was up to 584.99 mg TN/(L. d) at HRT of 17 h, while influent concentrations were kept 243.25 mg NH4* -N/L and 288.31 mg NO2^- -N/L.  相似文献   

17.
溶解氧对分段进水生物脱氮工艺的影响   总被引:4,自引:0,他引:4       下载免费PDF全文
采用分段进水生物脱氮工艺处理生活污水.设置0.9,0.6,0.4,0.3m3/h4组曝气量,相应的好氧区溶解氧(DO)浓度约为2.8,1.7,0.8,0.5mg/L左右.结果表明,在好氧区DO为0.5mg/L左右的低氧条件下,通过对系统进行适当的控制,可以取得较好的硝化效果,氨氮去除率可达98%以上.同时,由于低曝气量下混合液从好氧区到缺氧区携带的DO量减少,并且在好氧区发生了同步硝化反硝化作用,使得TN去除效果明显优于高曝气量的情况.另外,由于工艺结构的特点,分段进水生物脱氮系统可长期在低氧条件下运行,且污泥沉降性能良好.  相似文献   

18.
悬浮生物膜载体强化氨氮降解研究   总被引:2,自引:0,他引:2  
王文斌  祁佩时 《环境科学》2006,27(12):2502-2506
为了缩短氨氮降解时间,提高氨氮转移速率,利用新型悬浮载体对氨氮降解进行了研究.将生物膜培养分成3个阶段,每个阶段采用不同的运行条件,提高了膜上硝化菌的附着量,在载体上培养形成了以丝状细菌为附着体的蜂窝状微生物薄膜,增加了微生物附着的比表面积,薄膜的形成有利于氧气的扩散和基质的转移,为硝化菌提供了有利的生存环境.试验在pH值7.8~8.2,温度为24~29℃的条件下,在曝气90min时,氨氮从78 mg/L降解到2 mg/L以下,COD从140~300 mg/L降解到50mg/L以下;在曝气180min时,氨氮浓度从80~130 mg/L降解到3.5 mg/L以下,COD浓度从150~350 mg/L降解到46 mg/L以下.试验实现了同步去除COD和氨氮,与传统的活性污泥法相比,缩短了氨氮的降解时间,提高了氨氮降解速度.从微生物学和动力学理论对悬浮生物膜载体高效的氨氮降解和硝化机理进行了分析.  相似文献   

19.
城市污水处理厂化学强化生物除磷的试验研究   总被引:3,自引:0,他引:3  
为有效解决北京某城市污水处理厂出水总磷含量较高的实际问题,通过在生物处理工艺(A2O)后端添加化学除磷强化单元的方法,依次开展了实验室试验和现场的生产性试验.实验室试验以好氧池出水为试验用水,对不同浓度梯度的聚合氯化铝(PAC)、聚合硫酸铁(PFS)、三氯化铁(FeCl3)等除磷效果进行了对比研究,并分别对其除磷机理进行了深入的探讨.试验结果表明:3种药剂中,PAC除磷效果最好,当其投加量为60mg/L,投加系数β为4.15时,出水总磷含量可小于0.5mg/L,而且药剂投加成本较低,仅为0.078元/t.现场生产性试验选取好氧池出水端为药剂投加点,对PAC的除磷效果进行现场验证.经试验测定,当PAC投加量为60mg/L,投加系数β为4.22时,污水处理厂出水总磷含量远低于0.5mg/L,符合排放要求.考虑到进水量和负荷的波动,在保证出水达标排放的前提下,为保证药剂的有效利用,通过采取针对性措施提高前端生物除磷效率及反馈投加药剂的方法,以有效减少药剂的投加量及化学污泥的排放量,达到节能减排的目的.  相似文献   

20.
相较于传统强化生物除磷工艺通过测流实现污泥磷酸盐的富集和回收,生物膜法可对废水中的磷酸盐进行高效同步去除和富集,具有应用潜力。针对生物膜法厌氧释磷需要高碳源刺激的问题,通过优化工艺条件强化生物膜好氧吸磷能力提高生物膜蓄磷量,进而减少厌氧释磷时的碳源消耗。采用生物膜法序批式反应器(BSBR),考察了在低碳源投加下,蓄磷量与磷富集罐磷浓度的响应关系,采用正交试验探究溶解氧、搅拌速度以及好氧时间对磷酸盐强化吸收的影响。结果表明:当温度为(25±2)℃、厌氧外加碳源为(180±20) mg/L时,富集罐磷浓度随着生物膜蓄磷量的增加而增加,最高可达到90.62 mg/L。相同蓄磷量下,溶解氧浓度从2 mg/L增加至8 mg/L,磷酸盐最大吸收速率可从2.60 mg/(L·h)上升到8.70 mg/(L·h)。正交实验结果表明:各因素对磷酸盐强化吸收的影响顺序为溶解氧>好氧时间>搅拌速度。当溶解氧浓度为6 mg/L,搅拌速度为200 r/min,好氧时间为5 h时,除磷效率最高可达99.98%。  相似文献   