首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A sensitive and reliable method for the simultaneous determination of hydroxycoumarin-type (brodifacoum, bromadiolone, coumatetralyl, and warfarin) and indandione-type (chlorophacinone, diphacinone, and pindone) rodenticides in agricultural products by gel permeation chromatography (GPC) and liquid chromatography–tandem mass spectrometry (LC–MS/MS) was developed. The procedure involved extraction of the rodenticides from samples with acetone, followed by liquid–liquid partitioning with hexane/ethyl acetate (1:1, v/v) and 10% sodium chloride aqueous solution, then cleanup using GPC, and finally, analysis using LC–MS/MS. High recoveries from the GPC column were obtained for all rodenticides tested using a mobile phase of acetone/cyclohexane/triethylamine (400:1600:1, v/v/v). An ODS column, which contains low levels of metal impurities, gave satisfactory peak shapes for both hydroxycoumarin- and indandione-type rodenticides in the LC–MS/MS separation. The average recoveries of rodenticides from eight agricultural foods (apple, eggplant, cabbage, orange, potato, tomato, brown rice, and soybean) fortified at 0.0005–0.001 mg/kg ranged from 76 to 116%, except for bromadiolone in orange (53%) and diphacinone in soybean (54%), and the relative standard deviations ranged from 1 to 16%. The proposed method effectively removed interfering components, such as pigments and lipids, and showed high selectivity. In addition, the matrix effects were negligible for most of the rodenticide/food combinations. The results suggest that the proposed method is reliable and suitable for determining hydroxycoumarin- and indandione-type rodenticides in agricultural products.  相似文献   

2.

Background, aim, and scope

According to the high incidence of cancer worldwide, the amount of cytostatic drugs administered to patients has increased. These compounds are excreted to wastewaters, and therefore become potential water contaminants. At this stage, very little is known on the presence and elimination of cytostatic compounds in wastewater treatment plants (WWTP). The aim of this study was to develop a liquid chromatography?Chigh-resolution mass spectrometry (LC?COrbitrap?CMS) method for the determination of cyclophosphamide and epirubicin in wastewaters. These compounds represent two outmost used cytostatic agents.

Materials and methods

Extraction and analytical conditions were optimized for cyclophosphamide and epirubicin in wastewater. Both solid-phase extraction using Oasis 200?mg hydrophilic?Clipophilic balanced (HLB) cartridges and direct injection analysis were evaluated. Mass spectral characterization and fragmentation conditions were optimized at 50,000 resolving power (full width at half maximum, m/z 200) to obtain maximum sensitivity and identification performance. Quality parameters (recoveries, limits of detection, and repetitivity) of the methods developed were determined, and best performance was obtained with direct water analysis of the centrifuged wastewater. Finally, this method was applied to determine the presence of cyclophosphamide and epirubicin in wastewaters from a hospital effluent, an urban effluent, and influents and effluents from three WWTP.

Results and discussion

Cyclophosphamide and epirubicin were recovered after 50?mL preconcentration on solid-phase extraction 200?mg Oasis HLB cartridges (87% and 37%, respectively), and no breakthrough was observed by extracting 500?mL of water. Limits of detection were of 0.35 and 2.77?ng/L for cyclophosphamide and epirubicin, respectively. On the other hand, direct injection of water spiked at 1???g/L provided recoveries of 107% for cyclophosphamide and 44% for epirubicin and limits of detection from 3.1 to 85?ng?L?1, respectively. The analysis of wastewaters using direct injection analysis revealed the presence of cyclophosphamide and epirubicin in WWTP influents and hospital and urban effluents at levels ranging from 5.73 to 24.8???g?L?1.

Conclusions

The results obtained in this study demonstrate the capability of LC?COrbitrap?CMS for accurate trace analysis of these very polar contaminants. This method permitted to identify cyclophosphamide and epirubicin in wastewaters and influents of WWTP, but no traces were detected in WWTP effluents. The methodology herein developed is sensitive and robust and applicable for screening of a large number of samples since no preconcentration is needed.  相似文献   

3.
The aim of the study was to provide a comprehensive overview of neonicotinoid pesticide residues in honey samples for a single country and compare the results with the import data for neonicotinoid pesticides. The levels of four neonicotinoid pesticides, namely thiamethoxam, imidacloprid, acetamiprid, and thiacloprid, were determined in 294 honey samples harvested from 2005 to 2013 from more than 200 locations in Estonia. For the analyzed honey samples, 27% contained thiacloprid, and its levels in all cases were below the maximum residue level set by the European Union. The other neonicotinoids were not detected. The proportion of thiacloprid-positive samples for different years correlates well with the data on thiacloprid imports into Estonia, indicating that honey contamination with neonicotinoids can be estimated based on the import data.  相似文献   

4.
Techniques and applications of thin layer chromatography (planar chromatography) for the separation, detection, qualitative and quantitative determination, and preparative isolation of pesticides and their metabolites and other related compounds are reviewed for the period from November 1, 2008 to November 1, 2010. Analyses are described for a variety of samples types and pesticide classes. In addition to references on residue analysis, studies such as pesticide structure-retention relationships, identification and characterization of plant pesticides and synthesized pesticides, metabolism, degradation, mobility, identification of biomarkers for detection of herbicide effects in plants, and lipophilicity are covered.  相似文献   

5.
Applications of thin layer chromatography and high performance thin layer chromatography for the separation, detection, and qualitative and quantitative determination of pesticides, other agrochemicals, and related compounds are reviewed for the period from July 1, 2004 to November 1, 2006. Analyses are covered for a variety of samples, such as food, crops, biological, environmental, pharmaceuticals, and formulations, and for residues of pesticides of various types, including insecticides, herbicides, and fungicides, belonging to different chemical classes. In addition to references on residue analysis, studies such as pesticide-structure relationships, metabolism, degradation, and lipophilicity are covered, many of which make use of thin layer radiochromatography.  相似文献   

6.
Applications of thin layer chromatography and high performance thin layer chromatography for the separation, detection, qualitative and quantitative determination, and preparatire isolation of pesticides and their metabolites are reviewed for the period from July 1, 2006 to November 1, 2008. Analyses are described for a variety of sample types and pesticide classes. In addition to references on residue and formulation analysis, studies such as pesticide-structure relationships, identification and characterization of plant pesticides, metabolism, degradation, mobility, and lipophilicity are covered. Future prospects for pesticide thin layer chromatography are also considered.  相似文献   

7.
Publications reporting techniques and applications of thin layer chromatography (planar chromatography) for the separation, detection, qualitative, and quantitative determination, and preparative isolation of pesticides and their metabolites are reviewed for the period from November 1, 2012 to November 1, 2014. Analyses are described for a variety of sample types and pesticide classes. In addition to references on residue analysis, studies such as pesticide structure – retention relationships, identification and characterization of natural and synthesized pesticides, metabolism, bioactivity, degradation, soil mobility, and lipophilicity are covered.  相似文献   

8.
《Chemosphere》2013,90(11):1426-1436
Volatile organic compounds (VOCs) from several different municipal solid wastes’ treatment plants in Mallorca (Spain) have been analysed by thermal desorption–gas chromatography–mass spectrometry (TD–GC–MS). Ambient (immission) air was collected during February and March 2011 by active sampling onto sorbents Tenax™ TA and Carboxen™ 1000. The study presents the chemical characterisation of 93 volatile organic compounds (VOCs) from an overall set of 84 immission air samples. 70 VOCs were positively identified.The linear fit for all 93 external standard calibration, from 10 mg L−1 to 150 mg L−1 (n = 4), was within the range 0.974 < r2 < 0.998. Limits of detection of the method (LOD) for all the standards were within the range 1.1–4,213 pg, as the absolute standard amount spiked into sorbent tubes in 1 μL standard mixture (dissolved in methanol).Overall results stated systematic correlation between waste’s nature and VOCs’ air composition. Organic wastes show main contribution of terpenes, waste water sludge residues’ of reduced sulphured compounds (RSCs) and municipal solid wastes show contribution of a wide sort of VOCs. The use of a chemometric approach for variable’s reduction to 12 principal components enables evaluation of similarities and dissimilarities between facilities. PCA clearly related samples to its corresponding facility on the basis of their VOCs composition and the ambient temperature.  相似文献   

9.
An effective method for determination of indicator polychlorinated biphenyls (PCBs) has been validated using gas chromatography (GC) equipped with electron capture detector (ECD). The GC–ECD method was validated by determining the linear range (working range) for determination of the compounds, minimum detectable quantities (MDQ), the precision and accuracy of the method for the analysis of the compounds. MDQ obtained for the compounds ranges from 0.0005 to 0.002 ng. Indeed the method was found to be more sensitive as the number of chlorine atoms attached to the biphenyl increases. The precision and accuracy of the GC method validated ranges from 2.4% to 14.5% and −7.0% to 14.6% respectively. Coefficient of variation associated with the repeatability of the retention times and corresponding peak areas was found to be 0.0001–0.0007 for the retention times and 0.0014–0.059 for the peak areas. Percentage recoveries for the compounds were in the range of 95.7–101.0%. The validated method was then applied to determine levels of indicator PCBs in sediments sampled from eleven sampling points along the Lake Bosuntwi in Ghana and the highest PCB load of 19.17 ng g−1 was recorded at Pipie No. 2. PCB 52 and PCB 101 were found to be the most ubiquitous indicator PCBs in the study area, both with 90.91% occurrence.  相似文献   

10.
11.
Several methods were developed to detect the cyclic volatile methylsiloxanes (cVMSs) including octamethylcyclotetrasiloxane (D4), decamethylcyclopentasiloxane (D5), and dodecamethylcyclohexasiloxane (D6) in water, sediment, soil, biota, and biosolid samples. Analytical techniques employed to optimize measurement of this compound class in various matrices included membrane-assisted solvent extraction in water, liquid–solid extraction for sediment, soil, biota, and biosolid samples. A subsequent analysis of the extract was conducted by large-volume injection–gas chromatography−mass spectrometry (LVI−GC−MS). These methods employed no evaporative techniques to avoid potential losses and contamination of the volatile siloxanes. To compensate for the inability to improve detection limits by concentrating final sample extract volumes we used a LVI–GC–MS. Contamination during analysis was minimized by using a septumless GC configuration to avoid cVMS’s associated with septum bleed. These methods performed well achieving good linearity, low limits of detection, good precision, recovery, and a wide dynamic range. In addition, stability of cVMS in water and sediment was assessed under various storage conditions. D4 and D5 in Type-I (Milli-Q) water stored at 4 °C were stable within 29 d; however, significant depletion of D6 (60–70%) occurred only after 3 d. Whereas cVMS in sewage influent and effluent were stable at 4 °C within 21 d. cVMS in sediment sealed in amber glass jars at −20 °C and in pentane extracts in vials at −15 °C were stable during 1 month under both storage conditions.  相似文献   

12.
Emerging organic contaminants in wastewater are usually analyzed by targeted approaches, and especially estrogens have been the focus of environmental research due to their high hormonal activity. The selection of specific target compounds means, however, that most of the sample components, including transformation products and potential new contaminants, are neglected. In this study, the fate of steroidal compounds in wastewater treatment processes was evaluated by a nontargeted approach based on comprehensive two-dimensional gas chromatography–time-of-flight mass spectrometry. The potential of the nontargeted approach to generate comprehensive information about sample constituents was demonstrated with use of statistical tools. Transformation pathways of the tentatively identified compounds with steroidal four-ring structure were proposed. The purification efficiency of the wastewater treatment plants was studied, and the distribution of the compounds of interest in the suspended solids, effluent water, and sludge was measured. The results showed that, owing to strong adsorption of hydrophobic compounds onto the solid matter, the steroids were mostly bound to the suspended solids of the effluent water and the sewage sludge at the end of the treatment process. The most abundant steroid class was androstanes in the aqueous phase and cholestanes in the solid phase. 17β-estradiol was the most abundant estrogen in the aqueous phase, but it was only detected in the influent samples indicating efficient removal during the treatment process. In the sludge samples, however, high concentrations of an oxidation product of 17β-estradiol, estrone, were measured.  相似文献   

13.
A gas chromatography–mass spectrometry method has been proposed for the determination of low-level mutagenic and carcinogenic nitrosamines in particulate matter. The method includes the collection of particulate matters (PM2.5 and PM10) using a dichotomous Partisol 2025 sampler and extraction of the compounds from aqueous solution with dichloromethane/2-propanol after sonication with a slightly basic water solution prior to their GC-MS analysis in electron impact mode. The obtained recoveries of nitrosamines ranged from 92.4 to 99.2 %, and the precision of this method, as indicated by the relative standard deviations, was within the range of 0.95–2.46?%. The detection limits obtained from calculations using the GC-MS results based on S/N?=?3 were found within the range from 4 to 22 pg/m3. The predominant nitrosamines determined in particulate matter were N-nitrosodimethylamine, N-nitrosodiethylamine, N-nitrosodibutylamine and N-nitrosomorpholine. Furthermore, N-mono- and dinitrosopiperazine and N-nitrosoethylbutylamine were also determined. N-dinitrosopiperazine was detected in PM2.5 samples at the highest concentrations of up to 22.85 ng/m3 and in PM2.5–10 samples at concentrations up to 7.60 ng/m3 in winter, whereas it was found in PM2.5 samples up to 5.15 ng/m3 and in PM2.5–10 samples up to 3.12 ng/m3 in summer. The total concentrations of nitrosamines were up to 161.4 ng/m3 in fine and 53.90 ng/m3 in coarse fractions in winter, whereas in summer were up to 35.24 and 12.60 ng/m3, respectively. The concentration levels of nitrosamines fluctuated significantly within a year, with higher means and peak concentrations in the winter compared to that in the summertime. The seasonal variations of particle-associated nitrosamine concentrations were investigated together with their relationships with meteorological parameters using Pearson’s correlation analysis in the winter and summer periods. Analysis of variance was used to determine which concentrations of nitrosamines were statistically different from one another and, together with meteorological parameters and discriminant analysis, was used to classify the particle samples by particle size according to seasons. The classification results of the particle samples in different seasons were very satisfactory, allowing 99.5 % of cases to be correctly grouped.  相似文献   

14.
A study was conducted on the Brigham Young University campus during January and February 2015 to identify winter-time sources of fine particulate material in Utah Valley, Utah. Fine particulate mass and components and related gas-phase species were all measured on an hourly averaged basis. Light scattering was also measured during the study. Included in the sampling was the first-time source apportionment application of a new monitoring instrument for the measurement of fine particulate organic marker compounds on an hourly averaged basis. Organic marker compounds measured included levoglucosan, dehydroabietic acid, stearic acid, pyrene, and anthracene. A total of 248 hourly averaged data sets were available for a positive matrix factorization (PMF) analysis of sources of both primary and secondary fine particulate material. A total of nine factors were identified. The presence of wood smoke emissions was associated with levoglucosan, dehydroabietic acid, and pyrene markers. Fine particulate secondary nitrate, secondary organic material, and wood smoke accounted for 90% of the fine particulate material. Fine particle light scattering was dominated by sources associated with wood smoke and secondary ammonium nitrate with associated modeled fine particulate water.

Implications: The identification of sources and secondary formation pathways leading to observed levels of PM2.5 (particulate matter with an aerodynmaic diameter <2.5 μm) is important in making regulatory decisions on pollution control. The use of organic marker compounds in this assessment has proven useful; however, data obtained on a daily, or longer, sampling schedule limit the value of the information because diurnal changes associated with emissions and secondary aerosol formation cannot be identified. A new instrument, the gas chromtography–mass spectrometry (GC-MS) organic aerosol monitor, allows for the determination on these compounds on an hourly averaged basis. The demonstrated potential value of hourly averaged data in a source apportionment analysis indicates that significant improvement in the data used for making regulatory decisions is possible.  相似文献   


15.
Complex mixtures of contaminants with potential adverse effects on human health and wildlife are found in the environment and in the food chain. These mixtures include numerous anthropogenic compounds of various origins and structures, which may behave as endocrine disruptors. Mixture’s complexity is further enhanced by biotic and abiotic transformations. It is therefore necessary to develop new strategies allowing the identification of the structure of known, as well as unknown, nuclear receptor (NR) ligands present in complex matrices. We explored the possibility to use NR-based affinity columns to characterize the presence of bioactive molecules in environmental complex mixtures. Estrogen receptor α (ERα)-based affinity columns were used to trap and purify estrogenic substances present in surface sediment samples collected in a French river under mixed anthropogenic pressure. We combined biological, biochemical and analytical approaches to characterize the structure of ligands retained on columns and demonstrate the presence of known active molecules such as bisphenol A and octylphenol, but also of unexpected ERα ligands (n-butylparaben, hydroxyl-methyl-benzofuranone). High resolution mass spectrometry results demonstrate that ERα affinity columns can be used for the isolation, purification and identification of known as well as unknown estrogenic contaminants present in complex matrices.  相似文献   

16.
Environmental Science and Pollution Research - The determination of trace-level pharmaceuticals in water is generally performed using liquid chromatography combined with mass spectrometry, which is...  相似文献   

17.
In this study, a rapid and accurate ultra-fast liquid chromatography–tandem quadrupole mass spectrometry (UFLC–MS/MS) method coupled with the isotope internal standard dilution technique was established and validated to determine trace dicyandiamide (DCD) in mussels. The sample was extracted by acetonitrile, and chromatographic separations were performed on an Acquity UPLC BEH Amide column by using water–acetonitrile (9:91, v/v) as the mobile phase within 3 min. DCD was determined by using DCD-15N4 as an internal standard. The results showed that the recoveries were between 96.2 and 103 % with relative standard deviations (RSDs) in the range of 0.6–6.0 %. The limit of quantification (LOQ) was 0.05 μg/kg. This method can be applied to the routine analysis for the rapid and sensitive determination of trace DCD in mussels. Overall, the data reiterate the importance of investigating the presence of DCD in marine biological samples, which can act as food quality controls for human health.  相似文献   

18.
A fast and easy method was developed for the determination of glyphosate in maize and rice by using liquid chromatography triple quadrupole mass spectrometry with a Dionex Ion Pack column and phosphate buffer mobile phase. Samples were extracted with an acidified methanol solution. An isotope-labeled internal standard was added to the sample before extraction to ensure accurate tracking and quantification. The method’s performance was evaluated through a series of assessments to determine the accuracy, precision, linearity, matrix effect, limit of detection (LOD), and limit of quantification (LOQ). The mean recoveries for both matrices were within 70–105% at three fortification levels, including the LOQ. The precision for replicates was <20% (RSD%) for both matrices. Good linearity (R2=0.9982) was obtained over the concentration range of 0.01–1.5?mg kg?1. The LOD was determined to be 0.002?mg kg?1 for rice and 0.004?mg kg?1 for maize. The LOQ was 0.01?mg kg?1 for both maize and rice. Due to its versatility, the proposed method could be considered useful for the determination of glyphosate in cereals in routine analysis.  相似文献   

19.
Dissipation of β-cyfluthrin and imidacloprid in okra was studied following three applications of a combination formulation of Solomon 300 OD (β-cyfluthrin 9 % + imidacloprid 21 %) @ 60 and 120 g a.i. ha?1 at 7 days interval. Residues of β-cyfluthrin and imidacloprid in okra were estimated by gas liquid chromatography (GLC) and high performance liquid chromatography (HPLC), respectively. Residues of β-cyfluthrin were confirmed by gas chromatograph–mass spectrometry (GC-MS) and that of imidacloprid by high performance thin layer chromatography (HPTLC). Half-life periods for β-cyfluthrin were found to be 0.91 and 0.68 days whereas for imidacloprid these values were observed to be 0.85 and 0.96 days at single and double the application rates, respectively. Residues of β-cyfluthrin dissipated below its limit of quantification (LOQ) of 0.01 mg kg?1 after 3 and 5 days at single and double the application dosage, respectively. Similarly, residues of imidacloprid took 5 and 7 days to reach LOQ of 0.01 mg kg?1, at single and double dosages respectively. Soil samples collected after 15 days of the last application did not show the presence of β-cyfluthrin and imidacloprid at their detection limit of 0.01 mg kg?1.  相似文献   

20.
Dissipation of β-cyfluthrin and imidacloprid in okra was studied following three applications of a combination formulation of Solomon 300 OD (β-cyfluthrin 9 % + imidacloprid 21 %) @ 60 and 120 g a.i. ha(-1) at 7 days interval. Residues of β-cyfluthrin and imidacloprid in okra were estimated by gas liquid chromatography (GLC) and high performance liquid chromatography (HPLC), respectively. Residues of β-cyfluthrin were confirmed by gas chromatograph-mass spectrometry (GC-MS) and that of imidacloprid by high performance thin layer chromatography (HPTLC). Half-life periods for β-cyfluthrin were found to be 0.91 and 0.68 days whereas for imidacloprid these values were observed to be 0.85 and 0.96 days at single and double the application rates, respectively. Residues of β-cyfluthrin dissipated below its limit of quantification (LOQ) of 0.01 mg kg(-1) after 3 and 5 days at single and double the application dosage, respectively. Similarly, residues of imidacloprid took 5 and 7 days to reach LOQ of 0.01 mg kg(-1), at single and double dosages respectively. Soil samples collected after 15 days of the last application did not show the presence of β-cyfluthrin and imidacloprid at their detection limit of 0.01 mg kg(-1).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号