首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Using a laboratory-scale mixed reactor, the performance of alumina in degrading 2,4-Dichlorophenoxyacetic acid with ozone in the presence of tert-butyl alcohol radical scavenger was studied. The operating variables investigated were the dose of alumina catalyst and solution pH. Results showed that using ozone and alumina leads to a significant increase in 2,4-D removal in comparison to non-catalytic ozonation and adsorption processes. The observed reaction rate constants (kobs ) for 2,4-D during ozonation were found to increase linearly with increasing catalyst dose. At pH 5, the kobs value increased from 19.3 to 26 M?1 s?1 and 67 M?1 s?1 when varying the alumina dose from 1 to 2 and 4 g L?1, respectively. As pH was increased, higher reaction rates were observed for both non-catalytic ozonation and catalytic ozonation processes. Thus, at pH 3 and using a catalyst dose of 8 g L?1, the kobs values for non-catalytic ozonation and catalytic ozonation processes were 3.4 and 58.9 M?1 s?1, respectively, whereas at pH 5 reaction rate constants of 6.5 and 128.5 M?1 s?1 were observed, respectively. Analysis of total organic carbon suggested that catalytic ozonation with alumina achieved a considerable level of mineralization of 2,4-D. Adsorption of 2,4-D on alumina was found to play an important role in the catalytic ozonation process.  相似文献   

2.
On-line in-tube solid phase microextraction (in-tube SPME) coupled to high performance liquid chromatography and tandem mass spectrometry (HPLC-MS/MS) was successfully applied to the determination of selected triazines in water samples. The method based on the employment of a packed column containing graphene oxide (GO) supported on aminopropyl silica (Si) showed that the extraction phase has a high potential for triazines extraction aiming to its physical-chemical properties including ultrahigh specific surface area, good mechanical and thermal stability and high fracture strength. Injection volume and loading time were both investigated and optimized. The method validation using Si-GO to extract and concentrate the analytes showed satisfactory results, good sensitivity, good linearity (0.2–4.0 µg L?1) and low detection limits (1.1–2.9 ng L?1). The high extraction efficiency was determined with enrichment factors ranging from 1.2–2.9 for the lowest level, 1.3–4.9 intermediate level and 1.2–3.0 highest level (n = 3). Although the analytes were not detected in the real samples evaluated, the method has demonstrated to be efficient through its application in the analysis of spiked triazines in ground and mineral water samples.  相似文献   

3.
氧化石墨烯(GO)是一种理想的二维结构分离膜材料.从GO结构性质入手,探讨了GO混合基质膜和GO层压膜(GO膜)的制备及其在水处理中的研究现状与前景.分析了GO的添加方式对混合基质膜性能的影响,未来需要进一步对GO表面的活性基团进行改性以提高其分散性和与聚合物的相容性,并加强GO及改性GO的添加方式对膜性能影响的研究....  相似文献   

4.
采用PET编织管作为复合膜的结构层,将PVP和氧化石墨烯(GO)分别作为制孔剂和改性剂与PVDF基材混合,通过涂覆-浸没凝胶相转化法制备得到具有亲水性的高强度PVDF/PET编织管复合膜。观察复合膜的断面结构和表面形貌,测定其纯水通量、表面基团以及接触角等性能参数,并将不同浓度GO改性复合膜应用于序批式膜生物反应器(SMBR)中。利用原子力显微镜(AFM)及自制的污染物胶体探针测定了溶解性微生物产物(SMP)与膜面之间的微观作用力,考察改性复合膜的抗污染特性。在40 d的反应器运行实验中,GO改性复合膜的清洗周期较改性前延长了20%~40%,该结果说明改性复合膜能够有效抑制膜面对污染物的吸附,且GO质量分数为0.5%时清洗周期最长。AFM测试结果显示,复合膜中GO质量分数为0.5%时,SMP与膜面之间的黏附力最小,抗污染能力最强。  相似文献   

5.
Abstract

Activated carbons are well-known porous materials as an effective adsorbent used for the removal of emerging contaminants, such as herbicides, which are increasingly present in water bodies. Most water treatment plants, specially in Brazil, are unable to completely remove such contaminants by the conventional process and advanced treatment using activated carbons is required. The aim of this paper was to verify the influence of the activated carbons granulometry and specific surface area on the 2,4-dichlorophenoxyacetic acid (2,4-D) herbicide removal efficiency using distilled-deionized water and filtered water collected from a conventional Water Treatment Plant. Commercial activated carbons samples used in this work were obtained from two different manufacturers. Activated carbons were analyzed by the specific surface area, pore size and volume distribution, nuclear magnetic resonance, infrared and x-ray spectroscopy, moisture, volatile matter and ash contents. Batch adsorption isotherms experiments were used and performed by Langmuir and Freundlich models. Granular and powdered activated carbons removed over 99% of 2,4-D in distilled water and near to 99% using filtered water. The activated carbons evaluated in this work presented high performance and played a key role in water treatment by removing 2,4-D herbicide, ensuring the protection of human health and the ecosystem.  相似文献   

6.
Ferrari S  Mandel F  Berset JD 《Chemosphere》2002,47(2):173-182
An analytical method was developed to determine quantitatively 1-hydroxypyrene (OHP) in bovine urine samples. The procedure includes an enzymatic hydrolysis to cleave the conjugated metabolite, an enrichment step using solid phase extraction with a non-polar rinse step and elution with dichloromethane. A final clean-up on silicagel was performed before high-performance liquid chromatography (HPLC) analysis and fluorescence detection. Alternatively, HPLC and electrospray ionization in the negative ion mode applying selective ion monitoring acquisition revealed to be a highly sensitive detection method allowing the quantitation of low pg of OHP in the urine samples. The method was successfully applied to the determination of OHP in bovine urine samples from animals living in urban and rural areas. Urine concentrations of OHP were significantly higher (median 8.6 microg l(-1)) of bovines living close to a highway.  相似文献   

7.
饮用水中氟含量超标会损害人体的健康,本研究研制了一种改性吸附剂用于去除饮用水中过量的氟离子。本研究采用浸渍,焙烧的方法将金属盐负载到活性氧化镁上,制备改性活性氧化镁,考察了其除氟效果和吸附除氟的主要影响因素。结果表明,经过钙盐,铁盐改性后的活性氧化镁最大吸附容量显著增加,在复杂水体环境中仍有突出的除氟效果;改性吸附剂适宜pH为3~10;金属盐改性活性氧化镁处理水样不会有Mg2+和浸渍盐离子溶出,是一种安全可靠的吸附除氟材料。  相似文献   

8.
《Chemosphere》1987,16(6):1123-1135
Three different spectroscopic techniques, UV absorbance, fluorescence and sensitized room temperature phosphorescence are examined for the detection of polychlorinated dibenzofurans. A pre-column enrichment step is used prior to reversed-phase liquid chromatographic separation. The fluorescence detection mode offers the best sensitivity and selectivity but UV detection in combination with pre-column technology provides also a powerful means for trace analysis of the dibenzofurans. The method presented allows the determination of ppt-ppb concentration levels in polluted surface waters with good recoveries and reproducibility.  相似文献   

9.
A HPLC-MS/MS method is presented for the simultaneous determination of frequently used artificial sweeteners (ASs) and the main metabolite of aspartame (ASP), diketopiperazine (DKP), in environmental water samples using the direct-injection (DI) technique, thereby achieving limits of quantification (LOQ) of 10 ng L−1. For a reliable quantification of ASP pH should be adjusted to 4.3 to prevent formation of the metabolite. Acesulfame (ACE), saccharin (SAC), cyclamate (CYC) and sucralose (SUC) were ubiquitously found in water samples. Highest concentrations up to 61 μg L−1 of ACE were found in wastewater effluents, followed by surface water with concentrations up to 7 μg L−1, lakes up to 600 ng L−1 and groundwater and tap water up to 70 ng L−1. The metabolite DKP was only detected in wastewater up to 200 ng L−1 and at low detection frequencies.  相似文献   

10.
A method for determination of antibiotics in hospital sewage water has been developed and validated. Analogue internal standards for fluoroquinolones, sulfonamides, trimethoprim, beta-lactams (penicillins and cephalosporins), nitroimidazoles and tetracyclines were successfully used for calibration and shown to generally improve precision compared to external calibration. Matrix components caused ion suppression/enhancement effects during the MS detection for all analytes studied. Two effects were observed: general suppression and short-term variations in the MS response. In the hospital sewage water large temporal variations in the analyte concentration were observed during the course of the sampling period (seven grab samples in 13 h). Analyte concentrations varied within the following ranges (in microg l(-1)): ciprofloxacin, 3.6-101.0; metronidazole, 0.1-90.2; sulfamethoxazole, 0.4-12.8; ofloxacin, 0.2-7.6; trimethoprim, 0.6-7.6; and doxycycline, 0.6-6.7.  相似文献   

11.
A method for simultaneous quantitative determination of alkyl benzyl, dialkyl and trialkyl quaternary ammonium compounds (QACs) has been developed, validated and subsequently applied to real water samples in Austria. The method employs liquid-liquid extraction (LLE) followed by liquid chromatography/tandem mass spectrometry (LC-MS/MS), using electrospray ionization (ESI) in positive mode. The overall method quantification limits range from 4 to 19ng/L for the enrichment of 500mL water samples and analyte recoveries are between 80 and 99%. The method was applied to 62 of the respective water samples without filtration to avoid the loss of the analytes due to the high adsorption capacity of these compounds. Maxima in the mg/L range, especially in the wastewater of hospitals and laundries, could be detected for the selected target compounds.  相似文献   

12.
采用高效液相色谱-串联质谱(HPLC-MS/MS)检测,建立了地表水中13种药物及个人护理品的测定方法。水样用盐酸与氢氧化钠溶液调pH值至7.0左右,过固相萃取小柱进行富集,用14 mL甲醇洗脱。以C18柱为分离柱,0.01%甲酸的甲醇-0.01%甲酸水溶液为流动相,目标物在10 min内分离,在0.50~250 μg/L范围内,13种化合物峰面积与内标物质峰面积之比与质量浓度的线性关系良好(>0.99),检出限在0.05~0.5 ng/L范围内。基质加标实验结果表明,13种化合物在水中的回收率分别在56.2%~123.2%之间(加标水平5 ng/mL)和58.0%~107.8%(加标水平50 ng/mL),相对标准偏差在1.60%~19.9%(n=6)之间。应用该方法测定了从2条纳污河流采集的10份水样,结果表明,除美托诺尔和普洛萘尔未被检出外,其余11药物的检出频率在30%~100%之间。在13种目标物质中,咖啡因的检测浓度最高达287.5 ng/L,舒必利次之,为277.5 ng/L。本方法快速、准确,适用于地表水中PPCPs类的快速测定。  相似文献   

13.
A fast, simple and inexpensive method has been developed for the analysis of phenoxy acid herbicides: 2,4-dichlorophenoxyacetic acid (2,4-D), 4-chloro-2-methylphenoxyacetic acid (MCPA), 2-(4-chloro-o-tolyloxy)propionic acid (MCPP), 2-(4-aryloxyphenoxy)propionic acid (Fluazifop) and 2-(4-aryloxyphenoxy)propionic acid (Haloxyfop) in carrots and apples by liquid chromatography coupled to triple quadrupole mass spectrometry (LC/MS/MS). The compounds were analyzed by QuEChERS (quick, easy, cheap, effective, rugged, safe) methodology without cleanup.

The recoveries were performed at two spiked levels (0.05 and 0.5 mg/kg) for both matrices with six replicates for each level. The mean recoveries ranged from 70–92% for both apples and carrots. The precision of the method expressed as relative standard deviation (RSD%) was found to be in the range 3–15%. For all compounds, good linearity (r2 > 0.99) was obtained over the range of concentration from 0.05 μ g/mL to 0.5 μ g/mL, corresponding to the pesticide concentrations of 0.05 mg/kg and 0.5 mg/kg, respectively. The determination limits (LOQs) ranged from 0.01 ng/mL to 1.3 ng/mL in solvent, whereas, the LOQs calculated in matrix ranged from 0.05 ng/g to 21.0 ng/g for apples and from 0.06 ng/g to 10.2 ng/g for carrots. The developed methodology combines the advantages of both QuEChERS and LC/MS/MS producing a very rapid, sensitive and cheap method useful for the routine analytical laboratories.  相似文献   

14.
An extensive study on the presence of illicit drugs and pharmaceuticals with potential for abuse in sewage waters was made for the first time in the Netherlands. A total number of 24 target drugs were investigated in influent and effluent wastewater using liquid chromatography coupled to a high resolution Orbitrap mass spectrometer. This powerful analyzer has allowed not only the detection and identification of the compounds under investigation, but also their quantification at very low levels, which is highly innovative in the field of drugs of abuse. Samples were taken from five sewage treatment plants (STPs) during a whole week. The selected STPs served four cities of different size and an international airport. Daily variances of drug loads were demonstrated and removal efficiencies calculated for each drug and STP individually. Twelve target compounds were found in at least one influent or effluent, and highest concentrations were observed in influents collected from more urbanized areas. The compounds more frequently detected were amphetamine, benzoylecgonine, cocaine and THCCOOH together with the pharmaceuticals codeine, oxazepam and temazepam. Established week trends in consumption of drugs showed distinct differences between individual drugs. A slightly different occurrence pattern was observed in wastewaters from the airport. Thus, methamphetamine was only detected at Schiphol, a fact that was interpreted to be caused by consumption of this drug by travelers. Despite the fact that the Netherlands has frequently been criticized for its liberal drug policy the results from this study did not reveal higher drug consumption than found elsewhere, with the exception of cannabis.  相似文献   

15.
A carbon paste electrode was used for the electrochemical quantification of carbendazim in water and orange juice samples. Carbendazim oxidation on the electrode surface was found to be controlled by adsorption. The novel electrochemical procedure for carbendazim quantification employed differential pulse voltammetry using a carbon paste electrode under optimal conditions. Carbendazim oxidation currents were linear at concentrations of 2.84 to 45.44 µg L?1, with a limit of detection of 0.96 µg L?1. The proposed method was applied to carbendazim quantification in ultrapurified water, river water, and orange juice. Recovery rates in water and orange juice samples were in the 97%–101% range, indicating that the method can be employed to determine carbendazim in these matrices, with advantages including shorter analysis time and lower cost than routine methods such as chromatography or spectroscopy. The electrode showed good reproducibility, remarkable stability, and especially good surface renewability by simple mechanical polishing. The recovery rates observed were highly concordant with those obtained for high-performance liquid chromatography, having a relative standard deviation of less than 1.3%.  相似文献   

16.
There is a strong need for the development of relatively rapid and low-cost bioassays for the determination of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), and dioxin-like polychlorinated biphenyls (dl-PCBs) in environmental and food samples. In this study, we applied a reporter gene assay using DR-EcoScreen cells (DR-cell assay), which is highly sensitive to dioxins, to the determination of PCDD/Fs and dl-PCBs in fish and seafood samples. The PCDD/Fs and dl-PCBs were extracted from homogenated samples (10 g) of 30 fish and shellfish, purified by clean-up procedure using a multilayered silica gel column and an alumina column, and applied to DR-cell assay. Interestingly, the bioanalytical equivalent (BEQ) values obtained from the DR-cell assay [<0.1 ∼ 5.4 pg BEQ g−1 wet weight (ww)] were closely correlated with the toxicity equivalent (TEQ) values from conventional high-resolution gas chromatography/high-resolution mass spectrometry (HRGC-HRMS) analysis (r2 = 0.912), and the slope of regression line was 0.913. Therefore, we multiplied the BEQ values from the DR-cell assay by a conversion coefficient (1.095, the reciprocal of 0.913) to approximate the TEQ values from the HRGC-HRMS analysis. Furthermore, we used this DR-cell assay to perform a prescreening test of PCDD/Fs and dl-PCBs in 16 fish and seafood samples purchased from a supermarket, revealing that a sample from the fatty flesh of a bluefin tuna exceeded 8 pg TEQ g−1 ww (the European Union-tolerance limit). Taken together, these results suggest that the DR-cell assay might be applicable as a rapid and low-cost prescreening method to determine dioxin levels in fish and seafood samples.  相似文献   

17.
Abstract

This research is a case study on detection of pesticides in river water, sediment as well as fish samples from Tapi River, among the major rivers of Gujarat, India. To investigate the misuse, concentration level and occurrence patterns of persistent pesticides, samples were collected from the river. Chlorpyrifos, methyl parathion, hexachlorocyclohexane (HCH), dichloro diphenyl trichloroethane (DDT) and endosulfan were analyzed by gas chromatography technique with flame ionization detector (FID). Scanty reports are available, but after 1999, no such data are reported as some of these pesticides have been banned. Although these pesticides are still in use which we observed from the obtained results. In this river, the amount of endosulfan, chlorpyrifos, and methyl parathion was observed in surface water with concentrations of 37.56?µg/L, 0.86?µg/L and 0.43?µg/L, respectively. Endosulfan, DDT and methyl parathion detected in sediment were 38.38?ng/g, 0.65?ng/g and 0.77?ng/g, respectively. In fish samples, levels of endosulfan, chlorpyrifos, and methyl parathion detected were 101.28, 0.392, and 3.49?ng/g correspondingly. Results showed that highly toxic pesticides are still being used in the surrounding area, and there is an urgent need for enforcement of rules to control the production and application of such pesticides.  相似文献   

18.
In this work the development, validation and application of method using Solid Phase Microexctration (SPME) for the analyses of five pollutants (phenol, 2-nitrophenol, 2,4-dimethylphenol, 2,4-dichlorophenol and 4-chloro, 3-methyl phenol) in supplying water, using gas chromatography (GC) with flame ionization detector (FID) is described. The optimal conditions obtained for SPME were: fiber type: Poliacrylate (PA); extraction time: 40 minutes; extraction temperature: 70°C; amount of salt added to sample (NaCl): 15%; desorption temperature: 8 minutes. The parameters studied in the method validation were: limit of detection (0.3 and 3.5 μ g.L? 1); precision, measured by the variation coefficient (between 2.1 and 8.8%); calibration curve and linearity, by using the external standardization method (between 1 and 50 50 μ g.L? 1). After the methodology development, samples of water collected in Atibaia River (São Paulo - Brazil) were analyzed, using the optimized methodology. Three water samples collected in the rain season showed a peak with retention time close to 4-chloro, 3 methyl phenol further analyzed by Gas Chromatography-Mass Spectrometry for the identity confirmation. In spite of the fact that none target compounds were found in the river water samples analyzed, the presence of two phenols different from those investigated (p-terc butyl phenol; butylated hydroxytoluene) were detected. These results together with the results of the limit of detection (that showed to be lower than the maximum concentration of phenols demanded by different environment control agencies), and the results of the validation, indicate the applicability of this method for the analysis of selected phenols in river water samples.  相似文献   

19.
Abstract

A multiresidue solid‐phase extraction (SPE) method for the isolation and subsequent gas Chromatographie determination of organochlorine and organophosphorus pesticide residues in low‐moisture, nonfatty products is described. Residues are extracted from samples with an acetonitrile/water mixture. Cleanup of the extract is performed using graphitized carbon black and anion exchange SPE columns, and analysis is performed by gas chromatography with Hall electrolytic conductivity and flame photometric detection. Recovery data was obtained by fortifying corn, oats and wheat with pesticides. The average recoveries were 79–123% for eight organochlorine and 51–122% for 28 organophosphorus pesticide residues. The limit of quantitation for chlorpyriphos was 0.05 ppm using the Hall electrolytic conductivity detector and <0.005 ppm using the flame photometric detector.  相似文献   

20.
Liu L  Cheng J  Matsadiq G  Li JK 《Chemosphere》2011,83(10):1307-1312
A novel and simple method based on polymer monolith microextraction (PMME) coupled to gas chromatography with electron-capture detection (GC-ECD) was developed for the determination of six polychlorinated biphenyls (PCBs) residues in water samples. The proposed method used poly-(methyl methacrylate-co-ethylene dimethacrylate) (MMA-co-EDMA) monolith as extraction media. Several factors affecting experiments such as sample flow rate, sample volume, the type of eluent, eluent volume, eluent flow rate, effect of salt addition and carry over effect were investigated and optimized systematically. The limits of detection (LODs) for six PCBs were 0.028-0.043 ng mL−1 in water samples. The intra-day and inter-day precisions (R.S.D.) were less than 9.2% and 9.6%, respectively. The proposed method was successfully applied to the determination of six PCBs in tap water, lake water and industrial waste water and the trueness has been evaluated by recovery experiments. The obtained relative recoveries were in the range of 63.3-105.6%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号