首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 609 毫秒
1.
Food wastes collected from typical urban residential communities were investigated for the emission of volatile organic sulfur compounds (VOSCs) during laboratory-controlled aerobic decomposition in an incubator for a period of 41 days. Emission of VOSCs from the food wastes totaled 409.9 mg kg?1 (dry weight), and dimethyl disulfide (DMDS), dimethyl sulfide (DMS), methyl 2-propenyl disulfide, carbonyl sulfide and methyl 1-propenyl sulfide were the five most abundant VOSCs, with shares of 75.5%, 13.5%, 4.8%, 2.2% and 1.3% in total 15 VOSCs released, respectively. The emission fluxes of major VOSCs were very low at the beginning (day 0). They peaked at days 2–4 and then decreased sharply until they leveled off after 10 days of incubation. For most VOSCs, over 95% of their emission occurred in the first 10 days. The time series of VOSC emission fluxes, as well as their significant correlation with internal food waste temperature (p < 0.05) during incubation, suggested that production of VOSC species was induced mainly by microbial activities during the aerobic decomposition instead of as inherited. Released VOSCs accounted for 5.3% of sulfur content in the food wastes, implying that during aerobic decomposition considerable portion of sulfur in food wastes would be released into the atmosphere as VOSCs, primarily as DMDS, which is very short-lived in the atmosphere and thus usually less considered in the sources and sinks of reduced sulfur gases.  相似文献   

2.
GOAL, SCOPE AND BACKGROUND: Malodorous volatiles derived from the decomposition of biowaste within the process of composting might pose a risk to human health. Different techniques of process engineering have been developed to minimise the burden of malodorous compounds in air possibly affecting compost workers and residents in the vicinity. METHODS: In the present study, three different composting facilities were examined for the emission of volatiles to estimate the impact of process engineering on the dispersal of odorous compounds and to discuss its relevance for human health. RESULTS AND DISCUSSION: Concentrations of single compounds belonging to alcohols, ketones, furanes, sulfur-containing compounds and especially terpenes ranged from 10(2) up to nearly 10(6) ng/m3 depending on the sampling sites and the process engineering. The ratio of MVOC and total VOC measured changed throughout the process of biodegradation. A certain combination of volatile compounds coincided with the occurrence of typical compost odour. CONCLUSION: The type of process engineering seemed to have a major impact on the emission of volatiles, as amounts of (microbial) volatiles emitted were characteristic for the different techniques used. Thus, the MVOC emission basically depends on the degree of biodegradation. It is likely that the concentrations workers are exposed to can have an impact on human health. RECOMMENDATIONS AND OUTLOOK: It is obvious that less sophisticated types of process engineering give rise to greater amounts of bioaerosols and volatiles and, therefore, technical devices have to be improved and controlled regularly to minimise adverse health effects on workers.  相似文献   

3.
BACKGROUND, AIMS AND SCOPE: Composting facilities are known to release odorous volatiles due to biodegradation of municipal waste and plant residues. Although odour perception and its grading is influenced by experience, attitude and adaptation, these emissions have created a lack of acceptance for residents in the vicinity of composting facilities. Enclosure of compost pile halls, ventilation systems and biofilters are often insufficient to minimise the burden of compost-derived compounds in the air. Moreover, economic considerations forced smaller communities to establish less sophisticated facilities with open storage areas and other relevant sources for wind-borne dispersal of bioaerosols. Aim of the present study was to characterise the immission and dispersal of microbial volatiles (MVOC) and, besides, to find coincidences between MVOC and compost odour. METHODS: In the course of this study, the surroundings of two composting facilities, differing in their type of process engineering, were investigated for emission of volatiles in the environment. Both microbially and plant-derived substances were assessed, several of which have low odour thresholds. Air samples were taken in distances ranging from 50 to 800 m in a downwind direction from each facility. RESULTS AND DISCUSSION: Compost-derived and microbial volatile organic compounds (MVOC) were found at distances of up to 800 m from the composting facilities. Terpenes like alpha-pinene, camphene and camphor were the dominant compounds and coincided with typical compost odour, whereas several typical MVOC were not found at greater distances. The terpenes in combination with certain MVOC may play an important role in the perception of compost odour. Exposure concentrations were not of toxicological relevance, but sensory irritation and psychohygienic effects due to an annoyance potential of such compounds should not be dismissed. RECOMMENDATIONS AND OUTLOOK: Although terpenes are generally associated with pleasant odour characteristics, they seemed to contribute to malodours in a mixture with other VOC, in this context of volatile waste from compost facilities. Malodorous emissions from biowaste have to be considered as sources of health complaints and the investigation of mixtures of compost-derived volatiles is still inevitable. Exposure levels have to be discussed taking VOC mixtures into account. Within composting facilities, technical devices have to be improved to minimise dispersal of volatiles to prevent residents from immissions eventually causing health complaints.  相似文献   

4.
Essential oils, predominantly comprised of a group of aromatic chemicals, have attracted increasing attention as they are introduced into indoor environments through various forms of consumer products via different venues. Our study aimed to characterize the profiles and concentrations of emitted volatile organic compounds (VOCs) when evaporating essential oils indoors. Three popular essential oils in the market, lavender, eucalyptus, and tea tree, based on a nation-wide questionnaire survey, were tested. Specific aromatic compounds of interest were sampled during evaporating the essential oils, and analyzed by GC-MS. Indoor carbon monoxide (CO), carbon dioxide (CO2), total volatile organic compounds (TVOCs), and particulate matters (PM10) were measured by real-time, continuous monitors, and duplicate samples for airborne fungi and bacteria were collected in different periods of the evaporation. Indoor CO (average concentration 1.48 vs. 0.47 ppm at test vs. background), CO2 (543.21 vs. 435.47 ppm), and TVOCs (0.74 vs. 0.48 ppm) levels have increased significantly after evaporating essential oils, but not the PM10 (2.45 vs. 2.42 ppm). The anti-microbial activity on airborne microbes, an effect claimed by the use of many essential oils, could only be found at the first 30–60 min after the evaporation began as the highest levels of volatile components in these essential oils appeared to emit into the air, especially in the case of tea tree oil. High emissions of linalool (0.092–0.787 mg m−3), eucalyptol (0.007–0.856 mg m−3), d-limonene (0.004–0.153 mg m−3), ρ-cymene (0.019–0.141 mg m−3), and terpinene-4-ol-1 (0.029–0.978 mg m−3), all from the family of terpenes, were observed, and warranted for further examination for their health implications, especially for their potential contribution to the increasing indoor levels of secondary pollutants such as formaldehyde and secondary organic aerosols (SOAs) in the presence of ozone.  相似文献   

5.
《Chemosphere》2013,90(11):1426-1436
Volatile organic compounds (VOCs) from several different municipal solid wastes’ treatment plants in Mallorca (Spain) have been analysed by thermal desorption–gas chromatography–mass spectrometry (TD–GC–MS). Ambient (immission) air was collected during February and March 2011 by active sampling onto sorbents Tenax™ TA and Carboxen™ 1000. The study presents the chemical characterisation of 93 volatile organic compounds (VOCs) from an overall set of 84 immission air samples. 70 VOCs were positively identified.The linear fit for all 93 external standard calibration, from 10 mg L−1 to 150 mg L−1 (n = 4), was within the range 0.974 < r2 < 0.998. Limits of detection of the method (LOD) for all the standards were within the range 1.1–4,213 pg, as the absolute standard amount spiked into sorbent tubes in 1 μL standard mixture (dissolved in methanol).Overall results stated systematic correlation between waste’s nature and VOCs’ air composition. Organic wastes show main contribution of terpenes, waste water sludge residues’ of reduced sulphured compounds (RSCs) and municipal solid wastes show contribution of a wide sort of VOCs. The use of a chemometric approach for variable’s reduction to 12 principal components enables evaluation of similarities and dissimilarities between facilities. PCA clearly related samples to its corresponding facility on the basis of their VOCs composition and the ambient temperature.  相似文献   

6.
For quantitative estimate of biogenic volatile organic compound emissions (BVOCs) in South China and their impact on the regional atmospheric chemistry, a 3-day tropical cyclone-related ozone episode was modeled using chemical transport model CMAQ, which was driven by the mesoscale meteorological model MM5. Hourly biogenic emission inventories were constructed using the Sparse Matrix Operator Kernel Emissions (SMOKE) model. The simulation results show good agreement with observation data in air temperature, ozone and NOx levels. The estimated biogenic emissions of isoprene, terpene, and other reactive VOCs (ORVOCs) during this tropical cyclone-related episode are 8500, 3400, and 11 300 ton day−1, respectively. The ratio of isoprene to the total BVOCs was 36.4%. Two test runs were carried out with one incorporated biogenic emissions and the other without. The simulations show that Guangdong province, particularly the Pearl River Delta (PRD) region, was the area most reactive to biogenic emissions in South China. More ozone was produced in all layers under 1500 m when biogenic emissions were included in comparison to that without BVOCs. The net formation of ozone from 9:00 to 15:00 h was the highest near the surface and could reach 38 ppb, which include 4 ppb attributed to biogenic impact. The enhanced ozone due to biogenic emissions first appeared in the PRD region and slowly spread to a greater area in South China. Process analysis indicated that the surface ozone budget was dominated by the vertical transport and dry deposition. The horizontal transport and gas-phase chemical production were relatively small in the surface layer. Presumably, ozone was produced in upper layers within the atmospheric boundary layer and convected down to surface where it is destroyed. When BVOCs was included, apart from the enhancement of gas-phase chemical production of ozone, both the surface deposition and vertical transport were also augmented.  相似文献   

7.
Anaerobic sludge digester supernatant characterized by 569 mg TKN L?1, high color and a COD/N ratio of 1.4 was treated in granular sequencing batch reactors (GSBRs) followed by post-denitrification (P-D) and ultrafiltration (UF) steps. The use of granular sludge allowed for the oxidation of ammonium in anaerobic digester supernatant at all investigated GSBR cycle lengths of 6, 8 and 12 h. The highest ammonium removal rate (15 mg N g?1 VSS h?1) with removal efficiency of 99% was noted at 8 h.Since the GSBR effluent was characterized by a high concentration of nitrites, slowly-degradable substances and biomass, additional purification steps were applied. In P-D stage, the microbial activity of granular biomass in the GSBR effluent was implemented. The P-D was supported by external carbon source addition and the most advantageous variant comprised dosing of half of the theoretical acetate dose for nitrite reduction in the 3-h intervals. The use of the system consisting of the GSBR with 8 h, an optimal P-D variant and a UF for the treatment of anaerobic digester supernatant allowed for the 99%, 71% and 97% reductions of TKN, COD and color, respectively.  相似文献   

8.
We present bioaerosol source term concentrations from passive and active composting sources and compare emissions from green waste compost aged 1, 2, 4, 6, 8, 12 and 16 weeks. Results reveal that the age of compost has little effect on the bioaerosol concentrations emitted for passive windrow sources. However emissions from turning compost during the early stages may be higher than during the later stages of the composting process. The bioaerosol emissions from passive sources were in the range of 103–104 cfu m−3, with releases from active sources typically 1-log higher. We propose improvements to current risk assessment methodologies by examining emission rates and the differences between two air dispersion models for the prediction of downwind bioaerosol concentrations at off-site points of exposure. The SCREEN3 model provides a more precautionary estimate of the source depletion curves of bioaerosol emissions in comparison to ADMS 3.3. The results from both models predict that bioaerosol concentrations decrease to below typical background concentrations before 250 m, the distance at which the regulator in England and Wales may require a risk assessment to be completed.  相似文献   

9.
Isotope analysis was used to examine the extent of hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) biodegradation in groundwater along a ca. 1.35-km contamination plume. Biodegradation was proposed as a natural attenuating remediation method for the contaminated aquifer. By isotope analysis of RDX, the extent of biodegradation was found to reach up to 99.5% of the initial mass at a distance of 1.15–1.35 km down gradient from the contamination sources. A range of first-order biodegradation rates was calculated based on the degradation extents, with average half-life values ranging between 4.4 and 12.8 years for RDX biodegradation in the upper 15 m of the aquifer, assuming purely aerobic biodegradation, and between 10.9 and 31.2 years, assuming purely anaerobic biodegradation. Based on the geochemical data, an aerobic biodegradation pathway was suggested as the dominant attenuation process at the site. The calculated biodegradation rate was correlated with depth, showing decreasing degradation rates in deeper groundwater layers. Exceptionally low first-order kinetic constants were found in a borehole penetrating the bottom of the aquifer, with half life ranging between 85.0 to 161.5 years, assuming purely aerobic biodegradation, and between 207.5 and 394.3 years, assuming purely anaerobic biodegradation.The study showed that stable isotope fractionation analysis is a suitable tool to detect biodegradation of RDX in the environment. Our findings clearly indicated that RDX is naturally biodegraded in the contaminated aquifer. To the best of our knowledge, this is the first reported use of RDX isotope analysis to quantify its biodegradation in contaminated aquifers.  相似文献   

10.
The Ganqinfen system – a process of manually cleaning animal feces by means of a shovel – is a widely used manure separating method in Chinese pig farms. Ganqinfen pig feces and chopped corn stalks were mixed at the ratio of 7:1, and composted in 1.5 m3 rotting boxes for 70 d. Evolution of CH4, N2O and NH3 during composting, and the effects of turning and covering, were studied in this research. Results showed that 20–39% and 0.5–4% of total nitrogen were lost in the form of NH3 and N2O respectively, and 0.1–0.9% of initial organic carbon was emitted as CH4. Turning enhanced air exchange in the piles, thus decreasing CH4 emission by 83–93% and shortening the maturing period. When trials were finished, all non-turned piles were separated to three layers by moisture content. This structure caused the N2O losses of non-turning treatments to be 6–12.7 times higher than that of turning treatments. Covering materials reduced air exchange at the surface of the pile, thus decreasing the O2 supply and consequently increasing CH4 production by 33–45%. Covering also reduced NH3 emission by 4–34%. For the composting of Ganqinfen pig feces, we suggest that a program of turning twice weekly without covering will result in compost that is sufficiently matured after 6 wk with the lowest resultant greenhouse gas emission.  相似文献   

11.
We determined hourly emissions of isoprene, monoterpenes and sesquiterpenes from Siberian larch, one of the major tree species in Siberian forests. Summer volatile organic compounds (VOCs) emission from Siberian larch consisted mainly of monoterpenes (about 90%). The monoterpene emission spectrum remained constant during the measurement period, almost half was sabinene and other major monoterpenes were Δ3-carene, β- and α-pinene. During spring and summer, about 10% of the VOCs were sesquiterpenes, mainly α-farnesene. The sesquiterpene emissions declined to 3% in the fall. Isoprene, 2-methyl-3-buten-2-ol (MBO) and 1,8-cineole contributed to less than 3% of the VOC emission during the whole period. The diurnal variation of the emissions could be explained using a temperature-dependent parameterization. Emission potentials normalized to 30 °C were 5.2–21 μg gdw−1 h−1 (using β-value of 0.09 °C−1) for monoterpenes and 0.4–1.8 μg gdw−1 h−1 (using β-value of 0.143 °C−1, mean of determined values) for sesquiterpenes. Normalized monoterpene emission potentials were highest in late summer and elevated again in late fall. Sesquiterpene emission potentials were also highest in late summer, but decreased towards fall.  相似文献   

12.
The present study has been conducted in the frame of BUMA (Prioritization of Building Materials Emissions as indoor pollution sources), a European funded project, aiming at assessing the exposure to emitted compounds in indoor air. Field campaigns in five (5) European cities (Milan, Copenhagen, Dublin, Athens and Nicosia) were carried out. These campaigns covered weekly winter and summer concentration measurements in two (2) public buildings and two (2) private houses in each city. BTEX, terpenes, and carbonyls were measured using passive sampling in two sites inside the building and one outside. VOC emission measurements on selected building material have also been performed using Field and Laboratory Emission Cell (FLEC). The results on indoor concentrations for compounds such as formaldehyde (1.2–62.6 μg m?3), acetaldehyde (0.7–41.6 μg m?3), toluene (0.9–163.5 μg m?3), xylenes (0.2–177.5 μg m?3) and acetone (2.8–308.8 μg m?3) have shown diversity and relatively significant indoor sources depending on the building type, age etc. Indoor concentrations of these substances are varied depending on the building age and type. The percentage of approximately 40% of the indoor air quality levels originated from building materials.  相似文献   

13.
A 3-year research project was established in 1999 to create numerical reference data for material emissions during the time of construction and during the first year. Seven buildings, representing the present construction practice in Finland, were investigated. Material emissions were measured by using the field and laboratory cell (FLEC) during the time of construction, in the newly finished, and in the 6- and 12-month-old buildings. The emission rates for volatile organic compounds (VOCs), formaldehyde, and ammonia were determined.The highest total VOCs (TVOC) emissions were measured in the newly finished buildings from the ceiling structure and from some of the PVC floor coverings. These emissions were up to 1300–2000 μg m−2 h−1. Individual VOCs with emission rates above 50 μg m−2 h−1 included 2-(2-butoxyethoxy) ethanol and its acetate, C4–C16-substituted alkylbenzenes, and xylenes. The mean TVOC emission decreased at least to the Finnish M1-class level (200 μg m−2 h−1) from all surfaces and in all the buildings in 6–12 months. The ammonia and formaldehyde emissions from the ceiling structure were 20–60 μg m−2 h−1 in the newly finished buildings and the M1-levels (30/50 μg m−2 h−1) were exceeded in some cases. These emissions even increased in some buildings during the follow-up period indicating the difference between emissions measured in the laboratory and on site from real structures. Reference values based on the means and 95th percentile are presented to be utilised in both quality control and while investigating indoor air quality problems which are suspected to be caused by a defect structure.  相似文献   

14.
Burning of agricultural waste residue is a common method of disposal when preparing land following crop harvest. This practice introduces volatile organic compounds, including polycyclic aromatic hydrocarbons (PAHs), into the atmosphere. This study examines the particle size distribution in the smoke emissions of two common agricultural waste residues (biofuels) in California, almond prunings and rice straw. The residues were burned in a combustion chamber designed specifically for this purpose, and the smoke emissions were collected on 10-stage MOUDI impactors for analysis of PAH and total particle mass. The results, in units of emission factors, show that combustion temperature is an important factor in determining the smoke particle PAH composition. Total PAH emissions from rice straw burns were 18.6 mg kg−1 of fuel, while the emissions from almond prunings were lower at 8.03 mg kg−1. The less volatile five- and six-ring PAH was predominately on smaller particles where it condensed in the early stages of combustion while the more volatile three- and four-ring PAH formed on larger particles as the smoke cooled.  相似文献   

15.
On the basis of the last inventory of forests and climatic conditions in Poland, a national evaluation of the emissions of reactive volatile organic compounds (VOCs) was carried out. Calculations took into account the composition and age structure of forests as well as the temperature dependencies of VOC emission rate for the main European forest-forming tree species. In the case of isoprene, the dependence on illumination level and day length was also taken into account. Estimations were made for all 49 administrative regions of Poland. Depending on weather conditions in different years, the total VOC emission of Polish forests can be in the range 186–763 kt yr−1. For instance, for a moderately warm year, 1992, it was estimated at 440.6 kt, which represents 25% of the total VOC emissions in Poland.  相似文献   

16.
The effects of natural compounds on reducing formaldehyde emission from plywood were investigated. Urea, catechin and vanillin were examined as the natural formaldehyde reducers. The microemission cell, with an internal volume of 35 ml, the maximum exposed test surface area of 177 cm2 and an air purge flow rate of 50 ml min−1, was used to measure specific emission rate (SER). In the case of no reducer treatment, formaldehyde emission from plywood was fast and SERs were 4.4 mg m−2 h−1 at 30 °C and 15 mg m−2 h−1 at 60 °C. When this plywood was treated with the natural compounds, the SERs of formaldehyde were decreased at all temperatures. In the case of urea treatment, the SERs of formaldehyde decreased to 0.30 mg m−2 h−1 at 30 °C and 0.65 mg m−2 h−1 at 60 °C. When the urea treatment was applied to the inside of kitchen cabinet (made from plywood; 270 cm wide, 60 cm deep, 250 cm high), the concentration of formaldehyde was reduced substantially from 1600 to 130 μg m−3. The reducing effect of formaldehyde continued during the observation period (6 months), with a mean concentration of 100 μg m−3. Reducers in the plywood would react with released formaldehyde. Application of natural compounds such as urea, catechin and vanillin could provide a simple and effective approach for suppressing formaldehyde emission from plywood.  相似文献   

17.
Silage on dairy farms has been identified as a major source of volatile organic compound (VOC) emissions. However, rates of VOC emission from silage are not accurately known. In this work, we measured ethanol (a dominant silage VOC) emission from loose corn silage and exposed corn silage particles using wind tunnel systems. Flux of ethanol was highest immediately after exposing loose silage samples to moving air (as high as 220 g m?2 h?1) and declined by as much as 76-fold over 12 h as ethanol was depleted from samples. Emission rate and cumulative 12 h emission increased with temperature, silage permeability, exposed surface area, and air velocity over silage samples. These responses suggest that VOC emission from silage on farms is sensitive to climate and management practices. Ethanol emission rates from loose silage were generally higher than previous estimates of total VOC emission rates from silage and mixed feed. For 15 cm deep loose samples, mean cumulative emission was as high as 170 g m?2 (80% of initial ethanol mass) after 12 h of exposure to an air velocity of 5 m s?1. Emission rates measured with an emission isolation flux chamber were lower than rates measured in a wind tunnel and in an open setting. Results show that the US EPA emission isolation flux chamber method is not appropriate for estimating VOC emission rates from silage in the field.  相似文献   

18.
Volatile organic compounds (VOCs) emitted from poultry production are leading source of air quality problems. However, little is known about the speciation and levels of VOCs from poultry production. The objective of this study was the speciation of VOCs from a poultry facility using evacuated canisters and sorbent tubes. Samples were taken during active poultry production cycle and between production cycles. Levels of VOCs were highest in areas with birds and the compounds in those areas had a higher percentage of polar compounds (89%) compared to aliphatic hydrocarbons (2.2%). In areas without birds, levels of VOCs were 1/3 those with birds present and compounds had a higher total percentage of aliphatic hydrocarbons (25%). Of the VOCs quantified in this study, no single sampling method was capable of quantifying more than 55% of compounds and in several sections of the building each sampling method quantified less than 50% of the quantifiable VOCs. Key classes of chemicals quantified using evacuated canisters included both alcohols and ketones, while sorbent tube samples included volatile fatty acids and ketones. The top five compounds made up close to 70% of VOCs and included: 1) acetic acid (830.1 μg m?3); 2) 2,3-butanedione (680.6 μg m?3); 3) methanol (195.8 μg m?3); 4) acetone (104.6 μg m?3); and 5) ethanol (101.9 μg m?3). Location variations for top five compounds averaged 49.5% in each section of the building and averaged 87% for the entire building.  相似文献   

19.
《Chemosphere》2013,90(11):1407-1413
This study presents carbon (δ13C) and hydrogen (δD) isotope values of volatile organic compounds (VOCs) in various emission sources using thermal desorption–gas chromatography–isotope ratio mass spectrometry (TD–GC–irMS). The investigated VOCs ranged from C6 to C10. Samples were taken from (i) car exhaust emissions as well as from plant combustion experiments of (ii) various C3 and (iii) various C4 plants. We found significant differences in δ values of analysed VOCs between these sources, e.g. δ13C of benzene ranged between (i) −21.7 ± 0.2‰, (ii) −27.6 ± 1.6‰ and (iii) −16.3 ± 2.2‰, respectively and δD of benzene ranged between (i) −73 ± 13‰, (ii) −111 ± 10‰ and (iii) −70 ± 24‰, respectively. Results of VOCs present in investigated emission sources were compared to values from the literature (aluminium refinery emission). All source groups could be clearly distinguished using the dual approach of δ13C and δD analysis. The results of this study indicate that the correlation of compound specific carbon and hydrogen isotope analysis provides the potential for future research to trace the fate and to determine the origin of VOCs in the atmosphere using thermal desorption compound specific isotope analysis.  相似文献   

20.
Investigations have been undertaken at two integrated steelworks in the UK to characterise airborne organic micro-pollutants and to assess the contribution of iron ore sintering and coke making operations on the air quality. Concentrations of volatile organic compounds (VOCs), namely benzene, toluene and p-xylene, were measured continuously within the boundary of a coking plant using for the first time differential optical absorption spectrometry (DOAS) between 2004 and 2006. Concentrations were obtained along two monitoring paths surrounding the coke plant and the average benzene concentration measured along both paths over the campaign was 28 μg m?3. Highest benzene concentrations were associated with winds downwind of the coke oven batteries. Concentrations of polycyclic aromatic hydrocarbons (PAHs) in ambient air were measured during 27 consecutive days in 2005 at three different locations on an integrated steelworks. PAH profiles were determined for each sampling point and compared to coke oven and sinter plant emission profiles showing an impact from the steelworks. The mean benzo [a] pyrene concentration determined in the immediate vicinity of the coke ovens downwind from the battery was 19 ng m?3, whereas for the two other sites average benzo [a] pyrene concentrations were much lower (around 1 ng m?3). Data were analysed using principal components analysis (PCA) and results showed that coke making and iron ore sintering were responsible for most of the variation in the PAH concentrations in the vicinity of the investigated plant.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号