首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
饮用水消毒副产物研究状况   总被引:4,自引:1,他引:3  
本文介绍了饮用水中消毒副产物的研究状况。其中重点介绍了饮用水的消毒方式及四类消毒副产物的产生、浓度、存在形态及影响因素等。简单介绍了饮用水中消毒副产物的采集、前处理方法及污染控制对策等  相似文献   

2.
Drinking water in the vast Arctic Canadian territory of Nunavut is sourced from surface water lakes or rivers and transferred to man-made or natural reservoirs. The raw water is at a minimum treated by chlorination and distributed to customers either by trucks delivering to a water storage tank inside buildings or through a piped distribution system. The objective of this study was to characterize the chemical and microbial drinking water quality from source to tap in three hamlets (Coral Harbour, Pond Inlet and Pangnirtung—each has a population of <2000) on trucked service, and in Iqaluit (population ~6700), which uses a combination of trucked and piped water conveyance. Generally, the source and drinking water was of satisfactory microbial quality, containing Escherichia coli levels of <1 MPN/100 mL with a few exceptions, and selected pathogenic bacteria and parasites were below detection limits using quantitative polymerase chain reaction (qPCR) methods. Tap water in households receiving trucked water contained less than the recommended 0.2 mg/L of free chlorine, while piped drinking water in Iqaluit complied with Health Canada guidelines for residual chlorine (i.e. >0.2 mg/L free chlorine). Some buildings in the four communities contained manganese (Mn), copper (Cu), iron (Fe) and/or lead (Pb) concentrations above Health Canada guideline values for the aesthetic (Mn, Cu and Fe) and health (Pb) objectives. Corrosion of components of the drinking water distribution system (household storage tanks, premise plumbing) could be contributing to Pb, Cu and Fe levels, as the source water in three of the four communities had low alkalinity. The results point to the need for robust disinfection, which may include secondary disinfection or point-of-use disinfection, to prevent microbial risks in drinking water tanks in buildings and ultimately at the tap.  相似文献   

3.
Application of chlorination for the disinfection of drinking water results in the formation of a wide range of organic compounds, called disinfection by-products (DBPs), which occur due to the reaction of chlorine with natural organic materials. The occurrence of DBPs was studied in samples from four drinking-water treatment plants (WTPs) and from the distribution network of Athens, Greece. Twenty-four compounds, which belong to different categories of DBPs, were monitored, including trihalomethanes (THMs), haloacetic acids (HAAs), haloacetonitriles (HANs), haloketones (HAKs), chloral hydrate (CH) and chloropicrin (CP). Sampling was performed monthly for a period of two years, from three different points at each WTP and from eight points atthe distribution network. Samples were analyzed by GC-ECD methods, which included pretreatment with liquid-liquid extraction for volatile DBPs and acidic methanol esterification for HAAs. The results of the analyses have shown the presence of disinfection by-products belonging to all categories studied in all water samples collected after prechlorination. The major categories of DBPs detected were THMs and HAAs, while the other volatile DBPs occurred at lower concentrations. The concentrations of DBPs did not in any case exceed the maximum contaminant levels (MCL) set by USEPA and WHO. However, monitoring these compounds needs to be continued, because their levels could increase due to changes in the quality of water entering the water treatment plants. Reduction of the concentrations of DBPs could be achieved by optimization of the chlorination conditions, taking into account the effect of time. Moreover, research on alternative disinfection methods (e.g. ozone, chlorine dioxide, chloramines) and their by-products should be conducted to evaluate their applicability in the case of the drinking water of Greece.  相似文献   

4.
The levels of polycyclic aromatic hydrocarbons (PAHs) in the water and the sediment samples collected near the Mopanshan Reservoir—the most important drinking water resource of Harbin City in Northeast China—were examined. A total of 16 PAHs were concurrently identified and quantified in the three water bodies tested (Lalin River, Mangniu River, and Mopanshan Reservoir) and in the Mopanshan drinking water treatment plant during the high- and low water periods. The total PAH concentrations in the water and sediment samples ranged from 122.7 to 639.8 ng/L and from 89.1 to 749.0 ng/g dry weight, respectively. Similar spatial and temporal trends were also found for both samples. The lowest Σ16PAH concentration of the Mopanshan Reservoir was obtained during the high water period; by contrast, the Lalin River had the highest concentration during the low water period. The PAH profiles resembling the three water bodies, with high percentages of low-molecular weight PAHs and dominated by two- to three-ring PAHs (78.4 to 89.0 %). Two of the molecular indices used reflected the possible PAH sources, indicating the main input from coal combustion, especially during the low water period. The conventional drinking water treatment operations resulted in a 20.7 to 67.0 % decrease in the different-ringed PAHs in the Mopanshan-treated drinking water. These findings indicate that human activities negatively affect the drinking water resource. Without the obvious removal of the PAHs in the waterworks, drinking water poses certain potential health risks to people.  相似文献   

5.
From 2010 to 2012, the Yangtze River and Hanjiang River (Wuhan section) were monitored for estrogenic activities during various water level periods. Using a recombinant yeast estrogen screen (YES) assay, 54 water samples were evaluated over the course of nine sampling campaigns. The mean 17β-estradiol equivalent (EEQ) value of raw water from the Yangtze River was 0–5.20 ng/L; and the EEQ level from the Hanjiang River was 0–3.22 ng/L. In Wuhan, drinking water treatment plants (DWTPs) using conventional treatments reduced estrogenic activities by more than 89 %. In general, water samples collected during the level period showed weaker estrogenic activities compared to those collected during the dry period. The samples collected in 2010 showed the strongest estrogenic activities of the 3-year period. The lack of correlations between estrogenic activities and selected common water quality parameters showed that estrogenic activity cannot be tied to common water quality parameters.  相似文献   

6.
7.
Toor R  Mohseni M 《Chemosphere》2007,66(11):2087-2095
The presence of disinfection byproducts (DBPs) such as trihalomethanes (THMs) and haloacetic acids (HAAs) in drinking water is of great concern due to their adverse effects on human health. Emerging regulation limiting the concentration of DBPs in drinking water has increased demands for technologies and processes which reduce the formation of DBPs in drinking water. In this study, UV-H2O2 based advance oxidation process (AOP) was used to treat raw surface water. Experiments were conducted using low pressure mercury vapor UV lamps in collimated beam and flow-through annular photoreactors. The effect of UV fluence (0–3500 mJ cm−2) and hydrogen peroxide concentration (0–23 mg l−1) in reducing the concentration of THMs and HAAs was examined. The UV-H2O2 AOP was then coupled with a downstream biological activated carbon (BAC) treatment to assess the synergetic benefits of combining the two treatments. It was observed that UV-H2O2 AOP was only effective at reducing DBPs at UV fluences of more than 1000 mJ cm−2and initial H2O2 concentrations of about or greater than 23 mg l−1. However, the combined AOP–BAC treatment showed significant reductions of 43%, 52%, and 59% relative to untreated raw water for DBPs, TOC, and UV254, respectively.  相似文献   

8.
We investigated contamination by endocrine-disrupting chemicals in drinking water from 35 major Italian cities and five popular Italian brands of bottled mineral water. The quality of Italian drinking water was assessed by combing chemical analysis with bioassay to quantify specific estrogenic contaminants and to characterize the actual biological effect of the mixture of chemicals present in drinking water including the contribution of not targeted compounds. The selected contaminants were natural and synthetic steroid estrogens, alkylphenols and bisphenol A, linuron, triazine herbicides, and their metabolites. A specific analytical method was developed based on solid phase extraction of 1 L of water and concentration to 100 μL for quantification by electrospray ionization liquid chromatography tandem mass spectrometry, achieving quantification limits of 0.05–0.36 ng/L for herbicides and 0.64–7.70 ng/L for steroids and phenols. No steroid estrogens were detected in any of the samples, while bisphenol A and nonylphenols were detected in the ranges of 0.82–102.00 and 10.30–84.00 ng/L respectively. Herbicides and their degradation products, when present, were found from slightly above the quantification limits up to 49.91 ng/L, mainly from cities in northern Italy. Chemical analyses were complemented by the performance of a bioassay for the determination of the estrogenic activity in the extracts based on the transactivation of estrogen receptor α-transfected reporter HeLa-ERE-Luciferase-Neomycin cell line. Activity was generally low with maximum estrogenicity of 13.6 pg/L estradiol equivalents.  相似文献   

9.
In the pioneer days, the main driving forces for research of organics in drinking water treatment (DWT) were human health risks and optimisation of technology. The focus was on natural organic matter (NOM) structure, disinfection by-products (DBPs) formation, NOM removal by means of coagulation, adsorption, and oxidation, and development of the most efficient water treatment trains. Surprisingly, after decades of research, rapid development of analytical techniques and progress in risk assessment, the same driving forces are still in the limelight — although the topics have changed slightly. The attention switched from trihalomethanes to a new generation of DBPs. The definition of hydrophilic/hydrophobic NOM depends on the technique used for characterisation. It has become evident that numerous organic compounds can threaten water supply sources. Some of them had been ignored or overlooked in the past, but have recently been detected by advanced analytical tools even in drinking water. Prioritisation becomes priority per se. As far as processes are concerned, mainstream research has been following three lines: fouling mechanisms, application of hybrid processes and interactions between synthetic organic chemicals, other water constituents and materials used in DWT. Significant development has been made in membrane technology. This paper presents a broad overview of the recent organics research. Although the state-of-the-art technologies seem to have an answer to each and every question raised, it is still necessary to deal with specific problems on a case-by-case basis mainly due to the unique nature of NOM and different xenobiotics that may appear in various types of waters. In the end, human health risk, which derives from the presence/absence of organics, is only the tip of the iceberg — underneath lies a whole new universe — the socio-economic aspect of water treatment and quality that deserves much more attention.  相似文献   

10.
Halogenated acetaldehydes: analysis, stability and fate in drinking water   总被引:1,自引:0,他引:1  
Koudjonou BK  LeBel GL 《Chemosphere》2006,64(5):795-802
In our previous studies, chloral hydrate has been the only chlorinated acetaldehyde determined in drinking water because authentic standards of other related haloacetaldehydes were not available. Recently, standards of dichloroacetaldehyde, bromochloroacetaldehyde, dibromoacetaldehyde, bromodichloroacetaldehyde, chlorodibromoacetaldehyde, and tribromoacetaldehyde have become available commercially. They were obtained and verified for purity and stability using a dual-column GC-ECD system. Each commercial standard was found to contain small amounts of the other target haloacetaldehydes (HAs). The stability of the HAs stock solutions was solvent dependent: in acetone, the brominated species partially degraded to bromoacetone, while all target HAs were stable in MTBE for up to 8 months. The analytical parameters, required for the quantification of HAs in water, were determined and used to evaluate the stability of the HAs in water. Under the conditions of the sampling protocol (field pH adjustment to pH 4.5 and storage at 4 degrees C), the target HAs were stable in water for up to 14 days. However, at typical drinking water pH and temperature conditions, the stability varied with the HA species, pH, temperature and storage period. The trihalogenated acetaldehydes degraded, in part, to their corresponding trihalomethanes (THMs) at increasing pH and temperature. Most target HAs were detected in drinking water samples collected from various Canadian drinking water systems, and the speciation was dependent on water parameters (e.g. bromide concentration) and treatment processes. From the water samples analysed, chloral hydrate ranged between 7% and 51% of the total HAs (w/w). The weigh ratio of total HAs to total THMs (10-46%) indicated that HAs contributed significantly to the pool of DBPs in drinking water.  相似文献   

11.
Disinfection by-products in Finnish drinking waters   总被引:11,自引:0,他引:11  
Disinfection by-products (DBPs) were measured in plant effluents of 35 Finnish waterworks, which utilized different treatment processes and raw water sources. DBPs were measured also from the distribution systems of three waterworks. Di- and trichloroacetic acids, and chloroform were the major DBPs found in treated water samples. The concentration of six haloacetic acids (HAA6) exceeded the concentrations of trihalomethanes (THMs). Chlorinated drinking waters (DWs) originating from surface waters contained the highest concentration of HAA6 and THMs: 108 and 26 microg/l, respectively. The lowest concentrations of DBPs were measured from ozonated and/or activated carbon filtrated and chloraminated DWs. Higher concentrations of HAA6, THMs, and adsorbable organic halogens were measured in summer compared to winter. The levels of chlorinated acetic acids, chloroform, and bromodichloromethane correlated positively with mutagenicity. Past mutagenicity levels of DWs were examined. A major reduction in the use of prechlorination, increased use of chloramine disinfection, and better removal of organic carbon were the most important reasons for the 69% decrease in mutagenicity from 1985 to 1994.  相似文献   

12.
Chlorine has been utilized in the early stages of water treatment processes as disinfectant. Disinfection for drinking water reduces the risk of pathogenic infection but may pose a chemical threat to human health due to disinfection residues and their by-products (DBP) when the organic and inorganic precursors are present in water. In the last two decades, many modeling attempts have been made to predict the occurrence of DBP in drinking water. Models have been developed based on data generated in laboratory-scale and field-scale investigations. The objective of this paper is to develop a predictive model for DBP formation in the Alexandria governorate located at the northern west of Egypt based on field-scale investigations as well as laboratory-controlled experimentations. The present study showed that the correlation coefficient between trihalomethanes (THM) predicted and THM measured was R 2?=?0.88 and the minimum deviation percentage between THM predicted and THM measured was 0.8 %, the maximum deviation percentage was 89.3 %, and the average deviation was 17.8 %, while the correlation coefficient between dichloroacetic acid (DCAA) predicted and DCAA measured was R 2?=?0.98 and the minimum deviation percentage between DCAA predicted and DCAA measured was 1.3 %, the maximum deviation percentage was 47.2 %, and the average deviation was 16.6 %. In addition, the correlation coefficient between trichloroacetic acid (TCAA) predicted and TCAA measured was R 2?=?0.98 and the minimum deviation percentage between TCAA predicted and TCAA measured was 4.9 %, the maximum deviation percentage was 43.0 %, and the average deviation was 16.0 %.  相似文献   

13.
以某地表水为原水(TOC为5.3mg/L),研究了氯、氯胺和臭氧3种消毒剂对可同化有机碳(AOC)的影响。结果表明,投加1mg/L氯氧化30min就会使AOC升高近3倍。投加3种剂量(1、2、3mg/L)的氯胺,氧化30min时AOC增加不到1倍;氧化24h时AOC浓度均比30min时的高,这说明氯胺的作用机理与氯不同。投加臭氧2.0mg/L氧化30min时可使AOC增加2.4倍;当臭氧质量浓度大于2.0mg/L时,AOC开始下降,这说明一部分中间产物进一步被氧化成了二氧化碳和水。  相似文献   

14.
Background, aim and scope

After the discovery of chloroform in drinking water, an extensive amount of work has been dedicated to the factors influencing the formation of halogenated disinfections by-products (DBPs). The disinfection practice can vary significantly from one country to another. Whereas no disinfectant is added to many water supplies in Switzerland or no disinfectant residual is maintained in the distribution system, high disinfectant doses are applied together with high residual concentrations in the distribution system in other countries such as the USA or some southern European countries and Romania. In the present study, several treatment plants in the Somes river basin in Romania were investigated with regard to chlorine practice and DBP formation (trihalomethanes (THMs)). Laboratory kinetic studies were also performed to investigate whether there is a relationship between raw water dissolved organic matter, residual chlorine, water temperature and THM formation.

Materials and methods

Drinking water samples were collected from different sampling points in the water treatment plant (WTP) from Gilau and the corresponding distribution system in Cluj-Napoca and also from Beclean, Dej and Jibou WTPs. The water samples were collected once a month from July 2006 to November 2007 and stored in 40-mL vials closed with Teflon lined screw caps. Water samples were preserved at 4°C until analysis after sodium thiosulfate (Na2S2O3) had been added to quench residual chlorine. All samples were analysed for THMs using headspace GC-ECD between 1 and 7 days after sampling. The sample (10 mL) was filled into 20-mL headspace vials and closed with a Teflon-lined screw cap. Thereafter, the samples were equilibrated in an oven at 60°C for 45 min. The headspace (1 mL) was then injected into the GC (Cyanopropylphenyl Polysiloxane column, 30 m × 53 mm, 3 μm film thickness, Thermo Finnigan, USA). The MDLs for THMs were determined from the standard deviation of eight standards at 1 μg/L. The MDLs for CHCl3, CHBrCl2, CHBr2Cl and CHBr3 were 0.3, 0.2, 0.3 and 0.6 μg/L, respectively. All kinetic laboratory studies were carried out only with water from the WTP Gilau. The experiments were conducted under two conditions: baseline conditions (pH 7, 21°C, 2.5 mg/L Cl2) to gain information about the change of the organic matter in the raw water and seasonally variable conditions to simulate the actual process at the treatment plant and the distribution system.

Results and discussion

This study shows that the current chlorination practice in the investigated plants complies with the THM drinking water standards of the EU. The THM concentrations in all samples taken in the four treatment plants and distributions systems were below the EU drinking water standard for TTHMs of 100 μg/L. Due to the low bromide levels in the raw waters, the main THM formed in the investigated plants is chloroform. It could also be seen that the THM levels were typically lower in water supplies with groundwater as their water resource. In one plant (Dej) with a pre-ozonation step, a significantly lower (50%) THM formation during post-chlorination was observed. Laboratory chlorination experiments revealed a good correlation between chloroform formation and the consumed chlorine dose. Also, these experiments allowed a semi-quantative prediction of the chloroform formation in the distribution system of Cluj-Napoca.

Conclusions

CHCl3 was the most important trihalomethane species observed after the chlorination of water in all of the sampled months. However, TTHM concentrations did not exceed the maximum permissible value of 100 μg/L (EU). The THM formation rates in the distribution system of Cluj-Napoca have a high seasonal variability. Kinetic laboratory experiments could be used to predict chloroform formation in the Cluj-Napoca distribution system. Furthermore, an empirical model allowed an estimation of the chloroform formation in the Gilau water treatment plant.

  相似文献   

15.
Minimization of the formation of disinfection by-products   总被引:1,自引:0,他引:1  
The drinking water industry is required to minimize DBPs levels while ensuring adequate disinfection. In this study, efficient and appropriate treatment scheme for the reduction of disinfection by-product (DBPs) formation in drinking water containing natural organic matter has been established. This was carried out by the investigation of different treatment schemes consisting of enhanced coagulation, sedimentation, disinfection by using chlorine dioxide/ozone, filtration by sand filter, or granular activated carbon (GAC). Bench scale treatment schemes were applied on actual samples from different selected sites to identify the best conditions for the treatment of water. Samples were collected from effluent of each step in the treatment train in order to analyze pH, UV absorbance at 254 nm (UVA254), specific UV absorbance at 254 nm (SUVA254), dissolved organic carbon (DOC), haloacetic acids (HAAs) and trihalomethanes (THMs). The obtained results indicated that using pre-ozonation/enhanced coagulation/activated carbon filtration treatment train appears to be the most effective method for reducing DBPs precursors in drinking water treatment.  相似文献   

16.
The aim of this study was to investigate the performances of polyamide nanofiltration membranes during water reclamation. The study was conducted using nanofiltration concentrates obtained from two different nanofiltration drinking water treatment plants placed in the northern part of Serbia (Kikinda and Zrenjanin). Used nanofiltration concentrates contained high concentrations of arsenic (45 and 451 μg/L) and natural organic matter (43.1 and 224.40 mgKMnO4/L). Performances of polyamide nanofiltration membranes during water reclamation were investigated under various fluxes and transmembrane pressures in order to obtain drinking water from nanofiltration concentrates and, therefore, reduce the amount of produced concentrates and minimize the waste that has to be discharged in the environment. Applied polyamide nanofiltration membranes showed better removal efficiency during water reclamation when the concentrate with higher content of arsenic and natural organic matter was used while the obtained permeates were in accordance with European regulations. This study showed that total concentrate yield can be reduced to ~5 % of the optimum flux value, in both experiments. The obtained result for concentrate yield under the optimum flux presents considerable amount of reclaimed drinking water and valuable reduced quantity of produced wastewater.  相似文献   

17.
Liu Y  Mou S 《Chemosphere》2004,55(9):1253-1258
Disinfection by-products of interest such as bromate, chlorate and chlorinated haloacetic acids in 10 representative brands of bottled drinking water were investigated with ion chromatography. With the developed method, the detection limits of the disinfection by-products were in sub-microgl(-1) level. It was observed that bromate, chlorate and dichloroacetic acid could be detected in some water samples. In the bottled natural water, the concentrations for the three compounds were 0.1, 0.9 and 0.6 microgl(-1), respectively. The total concentration of disinfection by-products in the natural water sample was the highest among all the bottled drinking waters. The concentrations for the sum of disinfection by-products in the four types of bottled drinking water investigated were natural water > mineral water > spring water > purified water. The generation of disinfection by-products was much influenced by the original components and process procedure of the source water. The concentrations of bromate and chlorate in the bottled water samples hardly degraded with the increasing storage time. For dichloroacetic acid, with the prolonging of storage time, the concentration was much decreased.  相似文献   

18.
Biological aerated filters (BAFs) are widely used for the treatment of micropolluted surface water. However, the biological process produces dissolved organic nitrogen (DON), which, as precursors of nitrogenous disinfection by-products, pose potential threats to drinking water safety. Therefore, to control DON in BAF effluent, it is necessary to study the influence of BAF operation parameters on DON production. In this study, the influence of filtration velocity in a BAF on DON production was investigated. Under different filtration velocity (0.5, 2, and 4 m/h) conditions, profiles of DON concentrations along the media layer were measured. The profile at a filtration velocity of 0.5 m/h showed a decreasing trend, and the ones under filtration velocities of 2 and 4 m/h fluctuated in a small range (from 0.1 to 0.4 mg/L). Moreover, the relatively high filtration velocities of 2 and 4 m/h resulted in a lower level of DON concentration. Additionally, 3D excitation-emission matrix fluorescence spectroscopy was used to characterize DON. It is found that the patterns of DON at a relatively high filtration velocity condition (4 m/h) were obviously different from the ones under low filtration velocity conditions (0.5 and 2 m/h).  相似文献   

19.
采用活性炭多维电极法去除水中溶解态腐殖酸。实验结果表明 ,与活性炭单纯吸附法相比 ,活性炭多维电极法可显著提高对溶解态腐殖酸的去除率 ;在连续运行条件下 ,延长水力停留时间、升高槽电压、溶液偏碱性有利于腐殖酸的去除 ;高效液相色谱分析结果表明 ,电极的氧化还原作用可使有机物分子量变小或矿化 ,因而处理系统有可能延长活性炭的使用寿命  相似文献   

20.

Purpose

The purpose of this study is the development of a suitable process for the disinfection of drinking water by evaluating bactericidal efficacy of silver ions from silver electrodes.

Methods

A prototype of a silver ioniser with silver electrodes and control unit has been fabricated. Silver ions from silver electrodes in water samples were estimated with an atomic absorption spectrophotometer. A fresh culture of Escherichia coli (1.75?×?103 c.f.u./ml) was exposed to 1, 2, 5, 10 and 20?ppb of silver ions in 100?ml of autoclaved tap water for 60?min. The effect of different pH and temperatures on bactericidal efficacy was observed at constant silver ion concentration (5?ppb) and contact time of 30?min.

Results

The maximum bactericidal activity (100%) was observed at 20?ppb of silver ion concentration indicating total disinfection after 20?min while minimum bactericidal activity (25%) was observed after 10?min at 01?ppb of silver ions. Likewise, 100% bactericidal activity was noticed with 2, 5 and 10?ppb of silver ions after 60, 50 and 40?min, respectively. Bactericidal activity at pH?5, 6, 7, 8 and 9 was observed at 79.9%, 79.8%, 80.5%, 100% and 100%, respectively, whereas it was 80.4%, 88.3%, 100%, 100% and 100% at 10°C, 20°C, 30°C, 40°C and 50°C, respectively.

Conclusion

The findings of this study revealed that very low concentrations of silver ions at pH?8?C9 and temperature >20°C have bactericidal efficacy for total disinfection of drinking water. Silver ionisation is suitable for water disinfection and an appropriate alternative to chlorination which forms carcinogenic disinfection by-products.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号