首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Maximum nitrogen removal in the step-feed activated sludge process.   总被引:1,自引:0,他引:1  
This paper presents a mathematical framework that can be used to determine the flow distributions for a step-feed activated sludge process that result in maximum nitrogen removal. The model indicates that nitrogen removal efficiency in a step-feed activated sludge process is highly dependent on the ultimate biochemical oxygen demand (BOD(L))-to-total Kjeldahl nitrogen (TKN) ratio of the wastewater. For typical domestic wastewater, which has a relatively high BOD(L)-to-TKN ratio, the step-feed process will outperform the Modified Ludzack-Ettinger process for nitrogen removal, when the flow to each step is optimally distributed. Using plant-specific water quality data and operating conditions from a 1-year period, nitrogen removal performance for four step-feed activated sludge plants operated by the Sanitation Districts of Los Angeles County (California) was calculated using the developed model. The calculated nitrogen removal efficiencies match well with the actual plant performance data. These results validate the model as a useful tool for predicting nitrogen removal in a step-feed activated sludge process. Other analyses revealed that improvements in nitrogen removal at existing facilities are achievable by adjusting the split of primary effluent flow to each anoxic zone several times during the day. The timing of the adjustments and the optimal flow splits can be determined from data on diurnal fluctuations in BOD(L) and TKN concentrations. An example is provided to illustrate the application of such an operating strategy and the potential enhancement of nitrogen removal.  相似文献   

2.
基于神经网络的污水处理指标软测量研究   总被引:5,自引:0,他引:5  
污水处理厂目前广泛使用序批式活性污泥法.该方法处理污水过程是一种典型的复杂动态生物反应工程系统,具有非线性、时变性、随机性和不确定性等特点,难以建立准确的数学模型.同时,该方法的污水处理指标在线测量仪表价格昂贵.为从工程应用角度将人工神经网络软测量方法应用于污水水质指标的实时检测,分别建立BP神经网络和RBF神经网络污水指标软测量模型.仿真结果表明,建立的神经网络软测量模型能很好地实现污水处理指标的COD、BOD、N等参数的实时测量和估计,为污水指标的实时检测提供了新的思路.  相似文献   

3.
Food-service establishments that use on-site wastewater treatment systems are experiencing pretreatment system and/or drain field hydraulic and/or organic overloading. This study included characterization of four wastewater parameters (five-day biochemical oxygen demand [BOD5]; total suspended solids [TSS]; food, oil, and grease [FOG]; and flow) from 28 restaurants located in Texas during June, July, and August 2002. The field sampling methodology included taking a grab sample from each restaurant for 6 consecutive days at approximately the same time each day, followed by a 2-week break, and then sampling again for another 6 consecutive days, for a total of 12 samples per restaurant and 336 total observations. The analysis indicates higher organic (BOD5) and hydraulic values for restaurants than those typically found in the literature. The design values for this study for BOD5, TSS, FOG, and flow were 1523, 664, and 197 mg/L, and 96 L/day-seat respectively, which captured over 80% of the data collected.  相似文献   

4.
This paper examines potential uses of naturally growing aquatic plants for wastewater purification. These plants enhance the removal of pollutants by consuming part of them in the form of plant nutrients. This applies to urban and agricultural wastewater, in particular, where treatment units of different sizes can be applied at the pollution source. The effectiveness of wastewater purification by different plants was tested on laboratory and pilot scales. The growth rate of the plants was related to the wastewater content in the water. Batch and semicontinuous experiments verified that the plants are capable of decreasing all tested indicators for water quality to levels that permit the use of the purified water for irrigation. This applies to biochemical oxygen demand (BOD), chemical oxygen demand, total suspended solids. pH, and turbidity. In specific cases, the turbidity reached the level of drinking water. Comparison of BOD concentrations with typical levels in water treatment facilities across the country indicates the effectiveness of water purification with plants. A major effect of treatment with plants was elimination of the disturbing smell from the wastewater. It is shown that mixtures of wastewater and polluted water from the Kishon River are amenable in varying degrees to treatment by the plants. The higher the wastewater content in the mixture, the more effective the treatment by the plants. In this context, a scheme for rehabilitation and restoration of the Kishon River is presented and technical and economical aspects of the purification technology are considered.  相似文献   

5.
利用自行开发的混合呼吸速率测量仪在接种污泥的条件下对重庆某城市污水处理厂污水进行了呼吸速率测试(短期BOD测试,以呼吸速率测量重新进入内源呼吸阶段为结束);同时应用美国产BI-2000电解质呼吸仪在不接种污泥的条件下对该污水进行了BOD测试(长期BOD测试,理论上以污水中所有有机物矿化为结束)。对2种测试方法及其结果进行了比较,结果表明,2种方法得到的BCOD存在很大差异,短期BOD测试方法得到的结果仅为长期BOD测试方法得到的结果的40%~60%。通过批式呼吸测量方法测定了原废水中的活性异养微生物浓度XH(0),结果表明,XH(0)与BCODst之和与BCODlt比较接近,两者之比在0.88~1.02之间,平均值为0.94。  相似文献   

6.
A Xanthomonas sp. was isolated from the sludge on the drain outlet of a pharmaceutical factory. Then, the bacterium and carbon nanotubes (CNTs) were co-attached to an oxygen electrode for rapid analysis of biochemical oxygen demand (BOD). The response current was linear with BOD values in the range 10 to 300 mg/L for standard BOD solution with a response time of 35 seconds (R = 0.9994) and 20 to 580 mg/L for pharmaceutical wastewater with a response time < or =200 seconds (R = 0.9985), which means that this modified electrode might be used for online BOD analysis of pharmaceutical wastewater. Further studies revealed that the modified electrode can be used for BOD measurement in a high-salt condition. Also, the bacterium/CNTs biofilm can maintain its activity and good performance, even after being sealed and stored at 4 degrees C for 50 days.  相似文献   

7.
Although the long incubation time of biochemical oxygen demand (BOD7) measurements has been addressed by the use of microbial biosensors, the resulting sensor-BOD values gained from the measurements with specific industrial wastewaters still underestimates the BOD value of such samples. This research aims to provide fast and more accurate BOD measurements in the dairy wastewater samples. Unlike municipal wastewater, wastewater from the dairy industry contains many substrates that are not easily accessible to a majority of microorganisms. Therefore, a bacterial culture, Microbacterium phyllosphaerae, isolated from dairy wastewater was used to construct a semi-specific microbial biosensor. A universal microbial biosensor based on Pseudomonas fluorescens, which has a wide substrate spectrum but is nonspecific to dairy wastewater, was used as a comparison. BOD biosensors were calibrated with OECD synthetic wastewater, and experiments with different synthetic and actual wastewater samples were carried out. Results show that the semi-specific M. phyllosphaerae-based microbial biosensor is more sensitive towards wastewaters that contain milk derivates and butter whey than the P. fluorescens-based biosensor. Although the M. phyllosphaerae biosensor underestimates the BOD7 value of actual dairy wastewaters by 25–32 %, this bacterial culture is more suitable for BOD monitoring in dairy wastewater than P. fluorescens, which underestimated the same samples by 46–61 %.  相似文献   

8.
高盐工业废水人工湿地处理中植物的筛选   总被引:1,自引:0,他引:1  
通过人工湿地中试实验,考察了芦苇、睡莲、水葱、狭叶香蒲和宽叶香蒲水生植物单元对经生化处理的石油和精细化工工业区的工业废水中盐含量较高、氮磷营养盐含量较低和化学需氧量(COD)含量较高的废水中污染物的去除情况,研究了在植物不同生长阶段系统中COD的去除同盐度之间的关系,探讨了盐度差异对植物生长状况的影响,为确定人工湿地适合的进水盐度,达到有效去除高含盐量工业废水中有机污染物提供依据。结果表明,芦苇、睡莲和狭叶香蒲3种植物单元内高含盐量工业废水中污染物的净化效果较水葱和宽叶香蒲单元的净化效果好:前3种植物单元内COD、生化需氧量(BOD)和总磷(TP)的去除率大约在38%、55%和62%左右,而水葱和宽叶香蒲2种植物单元内COD、BOD和TP的去除率大约在30%、36%和52%左右;系统中各个单元内总氮(TN)去除率都在85%以上。在植物的不同生长阶段,人工湿地系统中氯离子浓度与COD浓度之间的相关性存在差异:植物生长初期,系统中氯离子浓度与系统中COD浓度之间无显著相关性,而在植物生长旺期和末期,两者则成正相关关系。因此,需根据植物的生长阶段调整人工湿地的进水盐度。  相似文献   

9.
通过在垂直流模拟人工土柱上种植不同的花卉植物,研究了垂直流花卉人工湿地对污水COD、BOD5、TN和TP的净化效果的影响。结果表明,所选用的5种陆生花卉,甚至鲜切花卉对化粪池污水有比较好的净化效果,它们对BOD5的去除率可达到92.04%以上,对TP的去除率甚至可达到97.77%以上。而且种植花卉植物的人工湿地出水水质要好于不种植物的对照湿地系统。  相似文献   

10.
Fenton氧化-生化组合工艺处理染料中间体废水   总被引:9,自引:4,他引:9  
针对染料中间体废水具有COD高、BOD5/COD低和具有生物毒性的特性,采用Fenton氧化-水解酸化-好氧组合工艺进行染料中间体生产废水的处理试验,试验结果表明:废水经Fenton氧化及水解酸化工序后,废水的BOD5/COD值由0.03升高至0.48,经好氧生化工序处理后的出水COD和BOD5浓度分别达122.6 mg/L和54.6 mg/L,符合《污水综合排放标准》(GB8978-1996)二级标准,该组合工艺COD总去除率达94%.  相似文献   

11.
Treatment of domestic wastewater by an hydroponic NFT system   总被引:11,自引:0,他引:11  
The objectives in this work were to investigate a conceptual layout for an inexpensive and simple system that would treat primary municipal wastewater to discharge standards. A commercial hydroponic system was adapted for this study and the wastewater was used to irrigate Datura innoxia plants. Influent and effluent samples were collected once a month for six months and analysed to determine the various parameters relating to the water quality. The legal discharge levels for total suspended, biochemical oxygen demand and chemical oxygen demand were reached with the plant system after 24 h of wastewater treatment. Total nitrogen and total phosphorus reduction were also obtained. NH4(+)-N was reduced by 93% with nitrification proving to be the predominant removal process. Significant nitrification occurred when the BOD5 level dropped 45 mg/l. Similar results were obtained for six months although the sewage composition varied widely. D. innoxia develops and uses the wastewater as the unique nutritive source.  相似文献   

12.
Pollutant-removal efficiency of certain macrophytes and algae, such as Eichhornia crassipes, Microcystis aeruginosa, Scenedesmus falcatus, Chlorella vulgaris and Chlamydomonas mirabilis, has been tested in laboratory conditions to evaluate their potential role in wastewater treatment. Sewage of Varanasi city, mixed with the effluents of about 1200 small-scale industries, was used for the tests. The investigation was performed in three stages i.e. a water hyacinth culture followed by an algal culture, and finally a second water hyacinth culture. For the first water hyacinth culture, 10 water hyacinth plants were grown in a tank of wastewater with 15 days' retention time. In the second stage, algal species were cultured in the treated wastewater for 5 days, whilst in the third stage, water hyacinth plants were again grown for further treatment of the wastewater for 9 days. This three-stage aquaculture resulted in very high reductions of BOD (96.9%), suspended solids (78.1%), total alkalinity (74.6%), PO(4)-P (89.2%), NO(3)-N (81.7%), acidity (73.3%), NH(4)-N (95.1%), COD (77.9%), hardness (68.6%) and coliform bacteria (99.2%). An increase in the concentration of dissolved oxygen (70%) was also observed.  相似文献   

13.
Three modeling approaches, the U.S. Environmental Protection Agency’s (EPA) Community Multiscale Air Quality (CMAQ) zero-out, the Comprehensive Air quality Model with extensions (CAMx) zero-out, and the CAMx probing tools ozone source apportionment tool (OSAT), were used to project the contributions of various source categories to future year design values for summer 8-hr average ozone concentrations at selected U.S. monitors. The CMAQ and CAMx zero-out or brute-force approaches predicted generally similar contributions for most of the source categories, with some small differences. One of the important findings from this study was that both the CMAQ and CAMx zero-out approaches tended to apportion a larger contribution to the “other” category than the OSAT approach. For the OSAT approach, this category is the difference between the total emissions and the sum of the tracked emissions and consists of non-U.S. emissions. For the zero-out approach, it also includes the effects of nonlinearities in the system because the sum of the sensitivities of all sources is not necessarily equal to the sum of their contributions in a nonperturbed environment. The study illustrates the strengths and weaknesses of source apportionment approaches, such as OSAT, and source sensitivity approaches, such as zero-out. The OSAT approach is suitable for studying source contributions, whereas the zero-out approach is suitable for studying response to emission changes. Future year design values of summer 8-hr average ozone concentrations were projected to decrease at all the selected monitors for all the simulations in each city, except at the downtown Los Angeles monitor. Both the CMAQ and CAMx results showed all modeled locations project attainment in 2018 and 2030 to the current National Ambient Air Quality Standards (NAAQS) level of 75 ppb, except the selected Los Angeles monitor in 2018 and the selected San Bernardino monitor in 2018 and 2030.
Implications:This study illustrates the strengths and weaknesses of three modeling approaches, CMAQ zero-out, CAMx zero-out, and OSAT to project contributions of various source categories to future year design values for summer 8-hr average ozone concentrations at selected U.S. monitors. The OSAT approach is suitable for studying source contributions, whereas the zero-out approach is suitable for studying response to emission changes. Future year design values of summer 8-hr average ozone concentrations were projected to decrease, except at the downtown Los Angeles monitor. Comparing projections with the current NAAQS (75 ppb) show attainment everywhere, except two locations in 2018 and one location in 2030.  相似文献   

14.
To enhance nitrogen removal in an existing microbial contact oxidation (MCO) system with a treatment capacity of 900 m3/d, an upflow multilayer bioreactor (UMBR) was chosen as a preanoxic reactor for the removal of organic matter and nitrate. The removal performance of the retrofitted plant was evaluated during the startup phase at a low temperature in winter. The high removal (>80%) of organic matter and suspended solids in the UMBR provided stable nitrification conditions in the MCO system, as a result of the substantial reduction in organic matter and solids loaded onto the MCO system. This treatment system showed a stable nitrogen removal efficiency of 75.3%, even in the low temperature range 7 to 10 degrees C. Phosphorus was completely removed by chemical precipitation. Production rates of excess sludge, as a function of the loads of influent flowrate and biological oxygen demand (BOD), were 0.022 kg dry solid/m3 wastewater and 0.132 kg dry solid/kg BOD.  相似文献   

15.
城市污水厂水质相关性及分布状态的研究和应用   总被引:1,自引:0,他引:1  
采用统计学及质量控制的一些基本理论及方法对污水处理厂的运行数据进行分析,得出城市污水处理厂BOD5、COD、SS、TN、TP等主要出水指标呈正态分布的规律;城市污水BOD5、COD、TN、TP等指标间存在显著线性相关性的结论.研究结论可用于污水处理厂制定经济合理的出水监测方案以及对污水处理厂运行可靠性等进行评估.  相似文献   

16.
The capacity to reach lower bounds for extraction of pollutants from wastewater by four floating aquatic macrophytes--water hyacinth (Eichhornia crassipes), water lettuce (Pistia stratiotes), salvinia (Salvinia rotundifolia), and water primroses (Ludvigia palustris)--is investigated. It is shown that the following lower bounds can be established for wastewater purification with water hyacinth: biochemical oxygen demand (BOD), 1.3 mg/L; chemical oxygen demand (COD), 11.3 mg/L; total suspended solids (TSS), 0.5 mg/L; turbidity, 0.7 NTU; ammonia, 0.2 mg/L; and phosphorus, 1.4 mg/L. Also, the following lower bounds can be established for wastewater purification with water lettuce: BOD, 1.8 mg/L; COD, 12.5 mg/L; TSS, 0.5 mg/L; turbidity, 0.9 NTU; ammonia, 0.2 mg/L; and phosphorus, 1.6 mg/L. These lower bounds were reached in 11- to 17-day experiments that were performed on diluted wastewater with reduced initial contents of the tested water quality indicators. As expected, water hyacinth exhibited the highest rates and levels of pollutant removal, thereby producing the best lower bounds of the water quality indicators. Given the initially low levels, BOD was further reduced by 86.3%, COD by 66.6%, ammonia by 97.8%, and phosphorus by 65.0% after 11 days of a batch experiment. The capacity of water plants to purify dilute wastewater streams opens new options for their application in the water treatment industry.  相似文献   

17.
The water chemistry, toxicity, and biodegradation of wastewater from an industry producing mineral fibres for thermal insulation were studied. Values for COD, BOD5, suspended solids, and phenol exceeded permissible values for the wastewater discharged into a nearby river and acute toxicity was also detected. Consequently, the effluent should be treated in a municipal wastewater treatment plant so its ready biodegradability was investigated. We found that the wastewater was readily biodegradable, therefore we assume it can be treated in the wastewater treatment plant as the ratio of the wastewater flow rate and the minimal total inflow into the sewage treatment plant would be one to at least 30.  相似文献   

18.
采用上流式分段污泥床(upflow staged sludge bed)反应器对聚酯废水进行了预处理试验研究.反应器内厌氧污泥经过近70 d的培养驯化后,用于处理聚酯废水.当进水COD值为800~2000 mg/L,HRT约为16~20 h时,其COD去除率基本能稳定在50%~55%之间;聚酯废水经预处理后,其BOD5/COD值由原来的0.3左右提高到约为0.6,取得了较好的预处理效果.但系统的总产气量由培养期的约13 L/d降至0.8 L/d左右,其中甲烷气体的含量也由50%下降至约6%.  相似文献   

19.
农药废水是一种典型的高浓度有机工业废水 ,有机污染物浓度高 (CODCr>10 0 0 0mg L) ,可生化性差 (氯苯农药废水BOD5 CODCr=0 .0 3 ,对邻硝基氯苯农药废水BOD5 CODCr=0 .0 5 )。采用微电解和Fenton试剂氧化两种物化手段对菊酯、氯苯和对邻硝氯苯 3种废水按比例配制而成的综合农药废水进行预处理 ,结果表明 :在废水pH为 2— 2 .5时 ,经微电解处理后 ,BOD5 CODCr比值在 0 .45以上 ,可生化性提高 ;Fenton试剂对综合农药废水CODCr去除率为 60 %左右 ,色度去除率接近 10 0 %  相似文献   

20.
A full-scale sequencing batch reactor (SBR) system was evaluated for its ability to remove carbon and nitrogen from swine wastewater. The SBR was operated on four, six-hour cycles each day, with each cycle consisting of 4.5 hours of "React," 0.75 hours of "Settling", 0.75 hours for "Draw" and "Fill." Within each cycle, an amount of wastewater equivalent to about 5% of the reactor volume (5,500 litres) was removed and added. The SBR system was able to remove 82% of biochemical oxygen demand (BOD) and more than 75% of nitrogen. Even though the SBR effluent, with an average effluent BOD5 of about 588 mg L(-1), did not meet the discharge criteria, it enabled a reduction of the land base required for land application of swine wastewater by about 75%. Results indicated that the SBR system was a viable method for the treatment of swine wastewater.  相似文献   