首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 672 毫秒
1.
为了研究墨粉在爆炸泄压过程中燃烧与流动的变化机制,通过改变泄爆片尺寸、墨粉浓度以及泄爆片的惯性力等参数对爆炸泄放过程中反应釜中压力以及外场火焰形态变化进行试验研究,同时与完全封闭空间内不同墨粉浓度的压力曲线对比。研究结果表明:相同泄爆开口尺寸下,粉尘浓度与受控爆炸压力(采用爆炸泄压保护措施后工业腔体内产生的压力)负相关;开口尺寸增加可以提升泄压效率;结合外场火焰形态的变化情况揭示声动火焰不稳定性对反应釜中压力发展的影响;通过无惯性泄爆试验的对比证明泄爆片惯性对受控爆炸压力的影响不可忽视。  相似文献   

2.
Computational modeling is a useful tool in determining the consequences from vapor cloud explosions. Here an approach that uses a flame-speed based combustion model is evaluated. Various scenarios of explosions in full-scale off-shore modules are simulated and compared to available test data. The ignition location of the cloud and available venting paths are found to affect the overpressure field in and outside the module. For end ignition cases, the combustion of gas pushed out of the module is found to play a key role. Using the flame-speed based model with appropriate effective flame speeds is found to provide accurate simulations.  相似文献   

3.
为有效防止粉尘爆炸泄爆引起的二次爆炸及火灾问题,基于泄压理论、消火机理,设计开发无火焰泄压装置,装置主要由消火结构、底座、爆破片及夹持机构组成,消火结构由不锈钢金属丝网组成。选择铝粉尘为测试粉尘,通过自建除尘系统试验平台进行试验研究。结果表明:无火焰泄压装置可成功阻止火焰传播,装置释放的冲击波在5 m外均小于5 kPa,除尘系统内部最大泄爆压力为0.1 MPa,装置前端火焰传播速度均大于100 m/s。  相似文献   

4.
A 20 L spherical explosive device with a venting diameter of 110 mm was used to study the vented pressure and flame propagation characteristics of corn dust explosion with an activation pressure of 0.78–2.1 bar and a dust concentration of 400∼900 g/m3. And the formation and prevention of secondary vented flame are analyzed and discussed. The results show that the maximum reduced explosion overpressure increases with the activation pressure, and the vented flame length and propagation speed increase first and then decrease with time. The pressure and flame venting process models are established, and the region where the secondary flame occurs is predicted. Whether there is pressure accompanying or not in the venting process, the flame venting process is divided into two stages: overpressure venting and normal pressure venting. In the overpressure venting stage, the flame shape gradually changes from under-expanded jet flame to turbulent jet flame. In the normal pressure venting stage, the flame form is a turbulent combustion flame, and a secondary flame occurs under certain conditions. The bleed flames within the test range are divided into three regions and four types according to the shape of the flame and whether there is a secondary flame. The analysis found that when the activation pressure is 0.78 bar and the dust concentration is less than 500 g/m3, there will be no secondary flame. Therefore, to prevent secondary flames, it is necessary to reduce the activation pressure and dust concentration. When the dust concentration is greater than 600 g/m3, the critical dust concentration of the secondary flame gradually increases with the increase of the activation pressure. Therefore, when the dust concentration is not controllable, a higher activation pressure can be selected based on comprehensive consideration of the activation pressure and destruction pressure of the device to prevent the occurrence of the secondary flame.  相似文献   

5.
To develop the application of explosion venting technology in high-pressure vessels, a new model for the design of dust explosion venting size was presented, which took the physicochemical phenomenon deriving from the elevation of the static activation pressure into account. Firstly, for confined pressure rise, the wall quenching effect originating from the dust flame thickness was considered by adopting the three-zone model. Secondly, for the venting pressure rise, the energy loss due to the discharge of high-energy burnt mixture (quantified as the specific surface area loss of the flame) was taken into account and the induced turbulence factor was introduced. Thirdly, for the venting pressure drop, a dynamic pressure relief capability evaluation model which takes into account the flame morphology evolution (tear-shaped flame) and the proportion of discharged mixture (relative volume ratio) at elevated activation pressure was proposed. The predicted maximum reduced pressure and venting size were checked against the PMMA explosion experiments and a more great performance was obtained compared with standards.  相似文献   

6.
Dust explosion venting is an established method of protecting against damaging explosion over-pressures, and guidance is available for many industrial situations. However, there is a need to: (a) establish the venting requirements of small vessels and whether current guidance and predictions in BS EN 14491:2006 need revising, and (b) improve understanding of the potential and limitations of flameless venting. This paper describes initial results from an ongoing programme of research.Small vessel tests are carried out using cornflour and wood dust on: a commercial sieve unit, a commercial cyclone, and a 0.5 m3 test vessel with explosion-relief openings without vent covers. Initial 0.5 m3 vessel tests give reduced explosion pressures that are lower than those predicted. This is because the predicted pressures are based on openings with vent covers. The reduced explosion pressures measured in the sieve unit and the cyclone are also less than predicted: the reasons are discussed.Flameless vesting tests are carried out using cornflour and wheat flour on a commercial flame arrestor unit. Initial tests demonstrate benefits, particularly a high level of flame extinguishment, but a problem of reduced venting efficiency compared to conventional venting.These initial results indicate that further research is needed.  相似文献   

7.
Explosion venting is a frequently-used way to lower explosion pressure and accident loss. Recently, studies of vessel explosion venting have received much attention, while little attention has been paid to pipe explosion venting. This study researched the characteristics of explosion venting for Coal Bed Methane (CBM) transfer pipe, and proposed the way of explosion venting to chamber in order to avoid the influence of explosion venting on external environment, and investigated the effects of explosion venting to atmosphere and chamber. When explosion venting to atmosphere, the average explosion impulse 4.89 kPa s; when explosion venting to 0 MPa (atmospheric pressure) chamber, average explosion impulse is 7.52 kPa s; when explosion venting to −0.01 MPa chamber, explosion flame and pressure obviously drop, and average explosion impulse decreases to 4.08 kPa s; when explosion venting to −0.09 MPa chamber, explosion flame goes out and average explosion impulse is 1.45 kPa s. Thus, the effect of explosion venting to negative chamber is far better than that to atmospheric chamber. Negative chamber can absorb more explosion gas and energy, increase stretch of explosion flame, and eliminate free radical of gas explosion. All these can promote the effect of explosion venting to negative chamber.  相似文献   

8.
为有效提高无火焰泄放装置产品质量特性和应用技术,避免或减轻爆炸事故发生造成的灾害程度,选择玉米淀粉粉尘为测试粉尘,采用1 m3爆炸罐进行扇形无火焰泄放装置爆炸泄放实验。结果表明:扇形无火焰泄放装置不适合重复使用。当扇形无火焰泄放装置重复进行爆炸泄放实验时,爆炸罐内压力会呈现升高趋势,而外场压力和温度呈现下降趋势,且阻火元件孔隙内残留大量玉米淀粉粉尘燃烧后生成的炭黑以及积聚部分高温燃烧的粉尘,致使阻火元件损坏失效。  相似文献   

9.
Explosion venting is widely applied in industrial explosion-proof designs due to the convenient, economical and practical features of this method. Natural gas is usually stored in storage tanks. If the gas in the vessel is mixed with air and encounters an ignition source, explosion venting might occur, producing jet fire, generating new secondary derivative accidents and causing casualties and property losses. In this paper, a set of test platforms including wire-mesh suppression devices is established to study the inhibition of jet fire induced by explosion venting by wire mesh. The experimental research shows that a wire mesh significantly inhibits the jet fire induced by explosion venting. The flame propagation velocity and pressure clearly decrease with increasing numbers of wire-mesh layers. The wire-mesh structure significantly affects the flame propagation, and the more layers of mesh there are, the better the suppression effect is. The flame temperature gradually decreases with the addition of the wire mesh. The mesh size significantly affects the pressure propagation of explosion venting. The explosion pressure gradually decreases with the addition of the wire mesh. With increasing distance between the wire mesh and the explosion vent, the maximum temperature first increases and then decreases, and the maximum explosion pressure first decreases and then increases. In the case of single gas cloud, the flame suppression effect is the most obvious when the wire mesh is 0.2 m away from the explosion vent. In the case of double gas clouds, the flame suppression effect is the most significant when the distance between the wire mesh and the first gas cloud is 0.4 m.  相似文献   

10.
A series of experiments on explosion venting of methane-air mixtures are performed to scrutinize the pressure evolution as well as the flame dynamics and morphology at various vent conditions. Specifically, a premixed flame is ignited at the center of a polycarbonate cylindrical compartment, with three various vent areas considered (with negligible vent relief pressure). As expected, the highest maximum pressure is observed in the case of the smallest vent area. For all three cases, the pressure evolution experiences two major peaks, associated with the instants (i) when the maximum flame front surface area in the chamber is reached and (ii) when an external explosion occurs due to venting of unburned gases, respectively. For the fuel-rich mixtures, a flashback is observed subsequent to the external explosion, constituting the key outcome of the present work. The flame tip velocities show two general trends, namely, exponential acceleration towards the vent, while a flame propagates towards the blocked side of the compartment with no acceleration, which is important to know in the fire/explosion safety applications.  相似文献   

11.
为了减少管内气体爆炸造成的损失与破坏,基于大涡模拟LES模型和Zimont燃烧模型,研究泄爆尺寸(直径为40,60,80 mm)和泄爆位置(侧方距点火端1,3,5 m)等泄爆条件对受限空间中氢气燃爆特性的影响。研究结果表明:大孔径泄爆口更好的排放效果造成火焰锋面在通过泄爆口时发生严重畸变,而泄爆口与点火端距离的增加则会削弱火焰锋面畸变的程度,且不同尺寸泄爆口产生的泄压效果差异较大。因此,应考虑将合适尺寸的泄爆口设置于靠近易燃点处。通过探索不同泄爆孔径与泄爆口位置对氢气火焰传播的影响规律,可为实际应用中的安全泄爆起到指导性作用。  相似文献   

12.
To further understand the dynamic mechanism of dust explosion through a vent duct, we designed a small-scale cylindrical vessel connected with a vent duct and performed a dust explosion venting experiment under different opening pressures using corn starch as the explosive medium in this study. The results show that weakening effect of duct on venting is positively correlated with the opening pressure. The explosion pressure in the duct presents a three-peak-structure with time, successively caused by the membrane breaking shock wave, the secondary explosion in the tube, and the continuous combustion, and decreases gradually with the propagation distance. Meanwhile, the three pressure peaks are positively correlated with the opening pressure, while the time interval between them goes to contrary. The increase of opening pressure leads to the increase of secondary explosion intensity and reverse flow in the vessel, further accelerates the reaction rate in the vessel, and then shortens the duration of combustion in the vessel until the phenomenon of flame reignition in the vessel disappears.  相似文献   

13.
The CFD tool FLACS was developed from 1982 with a primary goal to predict gas explosion loads inside oil platform modules. The prediction of far-field blast loads was of secondary importance as any scenario creating a substantial far-field blast would already have collapsed the module where it originated. For the same reason the potential for a deflagration-to-detonation-transition (DDT) was not initially of interest. Over the past decade use of FLACS has been more widespread, and the tool is now frequently used to predict explosions on onshore facilities and FPSOs/FLNGs, where far-field blast loads and evaluation of DDT potential may be of significant interest. Previous work by Hansen et al. (2010) has highlighted a weakness in FLACS when predicting the far-field blast from strong gas explosions and, when using FLACS according to guidelines, far-field blast pressures will often be significantly underpredicted. For scenarios involving DDT this effect will be particularly strong. The current study will present a way to obtain more accurate far-field blast predictions by modified parameter settings in FLACS for strong deflagrations. Using modified settings, it is also possible, with good precision, to predict flame speeds, pressures and far-field blast from DDT-scenarios and directly initiated gas detonations, physics which are beyond the accepted capabilities of FLACS. Selected full-scale experiments from the DNV GL test site at Spadeadam will be used to compare with the simulations. Convincing evidence for DDT in large scale natural gas experiments (91% methane) was found in simulations of one of these tests.  相似文献   

14.
The relief of a gas explosion in a tubular vessel by venting can be predicted by using a mathematical model. In this model, the flame acceleration is represented by an increase in the burning velocity. The movement of a vent cover can be included. The model assumes that the vent is blocked by the vent cover prior to the explosion. the venting ratio was the most influential parameter in terms of relieving the pressure. In the case of a large venting ratio, the flame acceleration made a highly significant contribution, whereas for small venting ratios, the weight of the vent cover contributed to the relief more than the flame acceleration. When the pressure is required to be reduced significantly, the venting ratio, the vent open pressure and the weight of the vent cover must all be reduced.  相似文献   

15.
Fire and explosion accidents are frequently caused by combustible dust, which has led to increased interest in this area of research. Although scholars have performed some research in this field, they often ignored interesting phenomena in their experiments. In this paper, we established a 2D numerical method to thoroughly investigate the particle motion and distribution before ignition. The optimal time for the corn starch dust cloud to ignite was determined in a semi-closed tube, and the characteristics of the flame propagation and temperature field were investigated after ignition inside and outside the tube. From the simulation, certain unexpected phenomena that occurred in the experiment were explained, and some suggestions were proposed for future experiments. The results from the simulation showed that 60–70 ms was the best time for the dust cloud to ignite. The local high-temperature flame clusters were caused by the agglomeration of high-temperature particles, and there were no flames near the wall of the tube due to particles gathering and attaching to the wall. Vortices formed around the nozzle, where the particle concentration was low and the flame spread slowly. During the explosion venting, particles flew out of the tube before the flame. The venting flame exhibited a “mushroom cloud” shape due to interactions with the vortex, and the flame maintained this shape as it was driven upward by the vortex.  相似文献   

16.
Dust explosion venting experiments were performed using a 20-L spherical chamber at elevated static activation overpressures larger than 1 bar. Lycopodium dust samples with mean diameter of 70 μm and electric igniters with 0.5 KJ ignition energy were used in the experiments. Explosion overpressures in the chamber and flame appearances near the vent were recorded simultaneously. The results indicated that the flame appeared as the under-expanded free jet with shock diamonds, when the overpressure in the chamber was larger than the critical pressure during the venting process. The flame appeared as the normal constant-pressure combustion when the pressure venting process finished. Three types of venting processes were concluded in the experiments: no secondary flame and no secondary explosion, secondary flame, secondary explosion. The occurrence of the secondary explosions near the vent was related to the vent diameter and the static activation overpressure. Larger diameters and lower static activation overpressures were beneficial to the occurrence of the secondary explosions. In current experiments, the secondary explosions only occurred at the following combinations of the vent diameter and the static activation overpressure: 40 mm and 1.2 bar, 60 mm and 1.2 bar, 60 mm and 1.8 bar.  相似文献   

17.
Dust and hybrid-mixture explosions continue to occur in industrial processes that handle fine powders and flammable gases. Considerable research is therefore conducted throughout the world with the objective of both preventing the occurrence and mitigating the consequences of such events. In the current work, research has been undertaken to help move the field of dust explosion prevention and mitigation from its current emphasis on hazards (with an accompanying reliance on primarily engineered safety features) to a focus on risk (with an accompanying reliance on hierarchical, risk-based, decision-making tools). Employing the principles of quantitative risk assessment (QRA) of dust and hybrid-mixture explosions, a methodological framework for the management of these risks has been developed.The QRA framework is based on hazard identification via credible accident scenarios for dust explosions, followed by probabilistic fault-tree analysis (using Relex – Reliability Excellence – software) and consequence severity analysis (using DESC – Dust Explosion Simulation Code – software). Identification of risk reduction measures in the framework is accomplished in a hierarchical manner by considering inherent safety measures, passive and active engineered devices, and procedural measures (in that order). An industrial case study is presented to show how inherent safety measures such as dust minimization and dust/process moderation can be helpful in reducing dust and hybrid-mixture explosion consequences in a 400-m3 polyethylene storage silo.  相似文献   

18.
Structures may be exposed to fire and blast due to accidents (i.e. explosion of flammable gas in industrial structures) or terrorist attacks during the service life. Performances of RC structures subjected to extreme conditions of fire and blast, thus, have drawn much attention from academia. In this paper, the coupling effect of high temperature and high strain rate in concrete was firstly studied based on the experimental data to improve the damage plasticity concrete model in ABAQUS. Secondly, the transient heat transfer effects in different fire scenarios and following fire resistances of RC columns with constant axial forces were numerically investigated on the basis of the improved concrete model, which are validated by the corresponding test data, and the residual axial loading capacity of RC columns was quantitatively calculated. By incorporating the different merits of implicit algorithm applied to heat transfer analyses and explicit algorithm usually used in blast analyses, a numerical approach to analyze the responses of RC columns subjected to the coupling loadings of fire and blast was finally developed. Mid-span displacements and damage of the RC columns subjected to fire and explosions were quantitatively calculated and discussed. The proposed approach was demonstrated to be effective in predicting the responses of RC structures subjected to coupling loadings of fire and blast.  相似文献   

19.
To effectively prevent and mitigate explosion hazards and casualties, relief venting of flammable gas explosions has been applied in production processes in a broad variety of industries. This work conducted fully vented experiments to investigate the influence of venting membrane thickness, and partially vented experiments to investigate the influence of baffle blocking rate on the explosion characteristics of 9.5 vol% methane-air mixtures in linked vessels with a 0.5 m long vented duct. Results indicate that the membrane thickness and blocking rate for the two types of vented explosions significantly affected the explosion overpressure. The smaller the membrane thickness and blocking rate, the lower the explosion overpressure. Secondary explosions were observed in the vented duct through experiments and a weaker explosion flame appeared at a small blocking rate of 20%. With the further increase in the blocking rate, the flame became extremely weak, and no secondary explosions occurred. The overpressure evolution process at different positions in the explosion duct and secondary explosion phenomenon in the vented duct were investigated. This work could probably serve as an important reference for the selection of technical parameters of explosion venting in the practical industrial processes.  相似文献   

20.
为研究泄爆面积比对泄爆门泄爆特性的影响,运用FLUENT软件建立煤矿井下1∶1巷道模型,在不同泄爆面积比的工况下对瓦斯爆炸传播规律及泄爆过程进行模拟,分析其变化特征和封闭泄爆效果。结果表明:S0工况条件下,压力和温度衰减后保持在0.29 MPa和565 K;S1~S4工况条件下,S4比S1,S2和S3达到封闭状态时间快780,260,50 ms,封闭时间最大节省70.91%;随着泄爆面积比的增大,封闭火区内的压力的峰值、峰值数量和达到封闭状态时间减小,泄爆能力增强;火焰速度峰值和衰减速率增大;温度的初始峰值、峰值数量和达到稳定状态时间减小,最大峰值反而增大,说明泄爆门对瓦斯爆炸火焰无抑制作用。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号