首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The dilution biochemical oxygen demand (BOD) test has widespread application for design and operation of wastewater treatment processes, evaluating the quality of natural waters, and assessing the effect of wastewater discharges on these waters. While standardization of the BOD-measuring method has become of prime importance in maintaining dependable data acquisition, changes are made as needed in response to questions raised by analysts and to accommodate new applications. The purpose of this article is to describe changes that have been incorporated in the 20th and 21st editions of Standard Methods for the Examination of Water and Wastewater (APHA et al., 1998 and 2004). These changes include changes in text format to clarify the procedural steps, allowance for use of bottle sizes ranging from 60 mL or larger, improvements in quality-control procedures, and improvements in the method of calculating BOD. Other changes include allowance for the use of allylthiourea for nitrification inhibition and broadening the source of seed that can be used for inoculation of BOD samples.  相似文献   

2.
Dilution water demand (DWD) can cause a positive error when the dilution biochemical oxygen demand (BOD) method is used. Dilution water demand may be attributed to oxidation of organic impurities in the dilution water and nitrification of ammonia added as a nutrient. To minimize the error associated with these sources, the standard BOD method requires that DWD be less than 0.2 mg/L in 5 days and does not allow correction for DWD when calculating test results. This study derives a set of theoretical equations to analyze the uncorrected errors with and without seeding. The authors concluded that DWD can be completely corrected if seeded dilution water is used for the sample dilution. When seeding individual bottles, the uncorrected error approaches 8.3 to approximately 8.8% at a 5-day depletion of 2 mg/L for a typical secondary effluent. Tests without seeding show an almost 1% higher uncorrected error than seeded tests. The analysis also suggests that these errors can be effectively reduced to less than 3% when the 5-day depletion approaches 6 mg/L. even for 5-day biochemical oxygen demand concentrations exceeding I x 10(4) mg/L. Further analysis indicates that, if not inhibited, the ammonium added to dilution water as a nutrient may contribute additional error due to nitrification.  相似文献   

3.
Antibiotic formulation effluents are well known for their difficult elimination by traditional bio-treatment methods and their important contribution to environmental pollution due to its fluctuating and recalcitrant nature. In the present study the effect of ozonation on the degradation of oxytetracycline (OTC) aqueous solution (100mgl(-1)) at different pH values (3, 7 and 11) was investigated. Ozone (11mgl(-1) corresponds the concentration of ozone in gas phase) was chosen considering its rapid reaction and decomposition rate. The concentration of oxytetracycline, chemical oxygen demand (COD), biochemical oxygen demand (BOD) and BOD5/COD ratio were the parameters to evaluate the efficiency of the ozonation process. In addition, the toxic potential of the OTC degradation was investigated by the bioluminescence test using the LUMIStox 300 instrument and results were expressed as the percentage inhibition of the luminescence of the marine bacteria Vibrio fischeri. The results demonstrate that ozonation as a partial step of a combined treatment concept is a potential technique for biodegradability enhancement of effluents from pharmaceutical industries containing high concentration of oxytetracycline provided that the appropriate ozonation period is selected. At pH 11 and after 60min of ozonation of oxytetracycline aqueous solutions (100 and 200mgl(-1)) the BOD5/COD ratios were 0.69 and 0.52, respectively. It was also shown that COD removal rates increase with increasing pH as a consequence of enhanced ozone decomposition rates at elevated pH values. The results of bioluminescence data indicate that first by-products after partial ozonation (5-30min) of OTC were more toxic than the parent compound.  相似文献   

4.
The 5 days at 20 degrees C biochemical oxygen demand (BOD5) is an important parameter for monitoring organic pollution in water and assessing the biotreatability of wastewater. Moreover, BOD5 is used for wastewater treatment plant discharge consents and other water pollution control purposes. However, the traditional bioassay method for estimating the BOD5 involves the incubation of sample water for 5 days. It follows that BOD5 is not available for real-time decisionmaking and process control purposes. On the other hand, previous efforts to solve this problem by developing more rapid biosensors had limited success. This paper reports on the development of Kohonen self-organizing map (KSOM)-based software sensors for the rapid prediction of BOD5. The findings indicate that the KSOM-based BOD5 estimates were in good agreement with those measured using the conventional bioassay method. This offers significant potential for more timely intervention and cost savings during problem diagnosis in water and wastewater treatment processes.  相似文献   

5.
A Xanthomonas sp. was isolated from the sludge on the drain outlet of a pharmaceutical factory. Then, the bacterium and carbon nanotubes (CNTs) were co-attached to an oxygen electrode for rapid analysis of biochemical oxygen demand (BOD). The response current was linear with BOD values in the range 10 to 300 mg/L for standard BOD solution with a response time of 35 seconds (R = 0.9994) and 20 to 580 mg/L for pharmaceutical wastewater with a response time < or =200 seconds (R = 0.9985), which means that this modified electrode might be used for online BOD analysis of pharmaceutical wastewater. Further studies revealed that the modified electrode can be used for BOD measurement in a high-salt condition. Also, the bacterium/CNTs biofilm can maintain its activity and good performance, even after being sealed and stored at 4 degrees C for 50 days.  相似文献   

6.
BOD5 dates back to 1912 when the Royal Commission decided to use the mean residence time of water in the rivers of England, 5 days, as a standard to measure the biochemical oxygen demand. Initially designed to protect the quality of river waters from extensive sewage discharge, the use of BOD5 has been quickly extended to waste water treatment plants (WWTPs) to monitor their efficiency on a daily basis. The measurement has been automatized but remains a tedious, time- and resource-consuming analysis. We have cross-validated a surrogate BOD5 method on two sites in France and in the USA with a total of 109 samples. This method uses a fluorescent redox indicator on a 96-well microplate to measure microbial catabolic activity for a large number of samples simultaneously. Three statistical tests were used to compare surrogate and reference methods and showed robust equivalence.  相似文献   

7.
The main objective of this investigation is to determine whether or not it would be feasible to use the measured values of biochemical oxygen demand (BOD) of wastewater obtained by an online instrument at the Los Angeles/Glendale Water Reclamation Plant (California) for controlling its activated sludge process. This investigation is part of a project to develop online BOD monitoring for process control in the City of Los Angeles wastewater treatment plants. Tests studied the Siepmann und Teutscher GmbH (ISCO-STIP Inc., Lincoln, Nebraska) BIOX-1010, which uses a bioreactor containing a culture of microbes from the wastewater to measure soluble BOD in 2 minutes. This rapid approximation to the operation of secondary treatment allows anticipation of system response. Calibration measurements allow the operators to find a conversion factor for the instrument's microprocessor to compute values of BOD that agree well with the standard 5-day BOD (BOD5) measurement, despite the differences in the details of the two testing methods. This instrument has recently been used at other wastewater treatment plants, at a number of airports in Europe and the United States to monitor runway runoff, and is also being used on waste streams at an increasing number of food processing plants. A comparison was made between the plant influent BOD values obtained by the BIOX-1010 online monitor from the end of August, 2000, to late January, 2001, and the individual and average values obtained for the same period using the standard BOD5, 20 degrees C test, to determine the effectiveness of the Biox-1010 to identify shock loads and their duration. Individual BOD estimates and averages over periods of overly high biological loads (shock loads) were compared, and the instrument readings were evaluated for their effectiveness in detecting shock loads. The results were highly satisfactory, so the instrument was used to trigger a shock-load warning alarm since late September, 2000. This allowed flow diversion and temporary storage to prevent process upsets.  相似文献   

8.
An upflow anaerobic sludge blanket (UASB)-anoxicaerobic system was used for treatment of tomato and bean processing wastewater. At various hydraulic retention times, ranging from 0.7 to 5 days, excellent removal of chemical oxygen demand (COD), biochemical oxygen demand (BOD), total suspended solids (TSS), ammonia-nitrogen (NH4-N), and total Kjeldahl nitrogen was achieved with final effluent BOD/TSS/NH4N concentrations of less than 15/15/1 mg/L. Biogas yield in the UASB reactor varied from 0.33 to 0.44 m3/kgCODremoved. The kinetics of anaerobic treatment were investigated. The yield coefficient was 0.03 gVSS/gCOD; maximum specific growth rate was 0.24 day(-1); Monod half velocity constant was 135 mgCOD/L; and specific substrate utilization rate was 3.25 gCOD/gVSS x d. Nitrification and denitrification kinetics were studied in batch experiments, and the rates were comparable with those in the continuous flow system.  相似文献   

9.
A two-stage membrane bioreactor was used to treat dissolved-air-flotation pretreated, high-strength pet food wastewater characterized by oil and grease concentrations of 50 000 to 82 000 mg/L and total chemical oxygen demand (COD) and five-day biochemical oxygen demand (BOD5) concentrations of 100 000 and 80 000 mg/L, respectively, to meet stringent surface discharge criteria (i.e., BOD5, total suspended solids [TSS], and ammonium-nitrogen [NH4(+)-N] of < 10 mg/L at an overall hydraulic retention time of 6.3 days). Organic contaminants were removed primarily in the first stage, followed by almost complete removal of ammonia in the second stage. Despite a rise in poorly biodegradable COD in the second stage, overall removal of TSS, BOD5, COD, and ammonia was 100, 99.9, 95.2, and 99.7%, respectively, thus readily achieving the required criteria. Consistent nitrite accumulation over a period of more than 100 days, even at dissolved oxygen concentrations of more than 2.5 mg/L, was remarkable. A residual alkalinity requirement for nitrification was quantified. Membrane performance was extensively studied in this work.  相似文献   

10.
This work evaluated the performance of a full-scale system with wetlands for slaughterhouse (abattoir) effluent treatment in the State of Hidalgo, México. The treatment system consisted of a primary sedimentation tank, an anaerobic lagoon, and a constructed subsurface-flow wetland, in series. The wetland accounted for almost 30% of the removal of organic matter. In general, the treatment system achieved satisfactory pollutant removals, but the final effluent could not meet the Mexican environmental regulations for fecal coliform counts, five-day biochemical oxygen demand (BOD5), and total suspended solids (TSS). Overall, removal levels were 91%, 89%, and 85% for BOD5, chemical oxygen demand, and TSS, respectively. However, BOD5 in the final effluent (137 mg/L) was higher than the maximum level of 30 mg/L allowed by the regulatory agency. Although organic nitrogen removal levels were approximately 80%, the nitrogen persisted in oxidation state -3 as ammonia-nitrogen, the removal of which was only 9% in the wetland stage. On average, phosphorus removal was null, and, on occasion, the phosphorus concentration in the treated effluent was higher than that of the influent. Coliform reductions in the overall system were high (on the order of 5 logs on average), whereas the coliform removal in the wetland was between 2 to 3.5 logs. The treatment system was also effective at removing pathogens (Vibrio cholerae, Salmonella, and Shigella). Further laboratory tests with the wetland effluent suggest that post treatment in a sand filter stage followed by disinfection with sodium hypochlorite (NaOCl) could help meet the Mexican discharge regulations, particularly the criteria for coliforms and total BOD5.  相似文献   

11.
River and sediment have unique carbon dynamics and are important sources of the dominant greenhouse gases (GHG), carbon dioxide (CO2) and methane (CH4). To understand the relationship between CO2/CH4 emissions and water quality/sediment characteristics, we have investigated critical parameters in the river water. Eight parameters of water quality (dissolved oxygen, oxidation-reduction potential [ORP], chemical oxygen demand, biochemical oxygen demand [BOD5], suspended solid, nitrate [NO3-], NH4+, and bacteria) and four sediment characteristics (total organic carbon [TOC], total nitrogen [T-N], NO3-, and ammonium [NH4+]) were measured in two of the larger rivers in Taiwan, and relevant environmental conditions were recorded. The experimental results indicated that CO2 emissions from the river were mainly affected by BOD5 concentrations and the levels of bacteria. CH4 emissions, on the other hand, were greatly affected by the ORP in the river. The correlation between CO2 emissions and sediment characteristics was insignificant (R2 < 0.3). However, TOC and T-N in the sediment may lead to increases in CH4 emissions into the atmosphere. A deeper analysis of the relationship between the different parameters and GHG emissions by ANOVA and the multiple regression method revealed that CO2 emission (y) was significantly related to bacteria number (x1) and BOD concentration (X2). The regression equation takes the form y = 0.00032x1 + 3.18089x2 + 25.37304. Also, the regression relationship between CH4 emission (y) and ORP (x) in the river can be described as y = -0.825216x + 169.02257. The relationship between CH4 emission and sediment characteristics may be described as y = 5.073962x1(TOC) + 2.871245x2(T-N) - 12.3262. Extra sampling data were collected to examine the feasibility of the developed multiple regression equations. The experimental results suggest that the emissions of such GHGs as CO2 and CH4 from rivers can be predicted using the regression equations developed here. Moreover, the emissions may be reduced by manipulating the proper factors.  相似文献   

12.
Combined wastewater collection systems continue to serve as a common urban conveyance method in urban areas of Europe and older urban areas of the United States. This study uses combined wastewater collection system monitoring data from the urbanizing Liguori catchment and channel in Cosenza (Italy) to illustrate event-based delivery and distribution of conveyed pollutant indices. Motivated by recent European Union (EU) discharge control legislation, this study specifically differentiates the event-based delivery of these indices between dry and wet-weather flows. Although the relatively steady to diurnal-variable delivery phenomena in dry weather flows are known, transport limiting phenomena for wet-weather hydrology and mass delivery typically are not known for the same catchment. Limiting categories of transport for a pollutant phase are generated by variables such as flow volume and duration, stream power, hydrograph parameters, and previous dry hours (PDH). Transport limitations of wet and dry weather events from the 414-ha catchment were analyzed and characterized as limited by mass indices (first-order, first flush transport) or limited by flow (zero-order transport). Results indicated significant concentration differences between mass- and flow-limited events. Higher concentrations were associated with mass-limited events. Frequency distributions of flow, total suspended solids (TSS), chemical oxygen demand (COD), and five-day biochemical oxygen demand (BOD5) were consistently exponential for wet-weather and mass-limited events. In contrast, flow, TSS, and BOD5 concentrations were distributed normally for flow-limited events. Results indicated a reasonable linear relationship between discharged TSS, COD, and BOD5 (biochemical oxygen demand) for Liguori Channel discharges into the Crati River. Wet-weather event transport was predominately mass-limited for TSS, COD, and BOD5.  相似文献   

13.
Food-service establishments that use on-site wastewater treatment systems are experiencing pretreatment system and/or drain field hydraulic and/or organic overloading. This study included characterization of four wastewater parameters (five-day biochemical oxygen demand [BOD5]; total suspended solids [TSS]; food, oil, and grease [FOG]; and flow) from 28 restaurants located in Texas during June, July, and August 2002. The field sampling methodology included taking a grab sample from each restaurant for 6 consecutive days at approximately the same time each day, followed by a 2-week break, and then sampling again for another 6 consecutive days, for a total of 12 samples per restaurant and 336 total observations. The analysis indicates higher organic (BOD5) and hydraulic values for restaurants than those typically found in the literature. The design values for this study for BOD5, TSS, FOG, and flow were 1523, 664, and 197 mg/L, and 96 L/day-seat respectively, which captured over 80% of the data collected.  相似文献   

14.
Berkun M 《Chemosphere》2005,59(2):207-215
Inorganic metals besides their direct toxic effects, carry the potential of causing serious variations on existing ecosystems in receiving waters. Self purification mechanism is vital for the continuity of the existing micro and macro living organisms in the streams. This mechanism is effected from the existence of metals. In this study, interferences of HgCl2, HgSO4, Ni(NO3)2, CrCl3, CuSO4.5H2O, K2Cr2O7, ZnSO4.7H2O and Al2(SO4)3.18H2O metal compounds on respirometric BOD and related effects on the self purification, are investigated with the representative formations of DO deficit curves. In the presence of these metals, streamwater BOD parameters and related DO deficit curve formations are significantly effected.  相似文献   

15.
A full-scale sequencing batch reactor (SBR) system was evaluated for its ability to remove carbon and nitrogen from swine wastewater. The SBR was operated on four, six-hour cycles each day, with each cycle consisting of 4.5 hours of "React," 0.75 hours of "Settling", 0.75 hours for "Draw" and "Fill." Within each cycle, an amount of wastewater equivalent to about 5% of the reactor volume (5,500 litres) was removed and added. The SBR system was able to remove 82% of biochemical oxygen demand (BOD) and more than 75% of nitrogen. Even though the SBR effluent, with an average effluent BOD5 of about 588 mg L(-1), did not meet the discharge criteria, it enabled a reduction of the land base required for land application of swine wastewater by about 75%. Results indicated that the SBR system was a viable method for the treatment of swine wastewater.  相似文献   

16.
The characteristics of municipal wastewater treatment by electrolysis, ozonation, and combination processes of electrolysis and aeration using three gaseous species (nitrogen [N2], oxygen [O2], and ozone [O3]) were discussed in this research using ruthenium oxide (RuO2)-coated titanium anodes and stainless-steel (SUS304) cathodes. Electrolysis and electrolysis with nitrogen aeration were characterized by a rapid decrease in 5-day biochemical oxygen demand (BODs) and total nitrogen and a slow decrease in chemical oxygen demand (COD). In contrast, ozonation, electrolysis with oxygen aeration, and electrolysis with ozone aeration were characterized by transformation of persistent organic matter to biodegradable matter and preservation of total nitrogen. The best energy efficiency in removing BOD5 and total nitrogen was demonstrated by electrolysis, as a result of direct anodic oxidation and indirect oxidation with free chlorine produced from the chloride ion (Cl-) at the anodes. However, electrolysis with ozone aeration was found to be superior to the other processes, in terms of its energy efficiency in removing COD and its ability to remove COD completely, as a result of hydroxyl radical (*OH) production via cathodic reduction of ozone.  相似文献   

17.
Urban stormwater runoff quality, widely investigated around the world, has been monitored less in Beijing, China, which impedes the municipal government to use best management practices to protect surface water. In this study, rainwater and stormwater runoff samples from roofs, roads, and a lawn on the campus of the Research Center for Eco-Environmental Sciences (RCEES) (Beijing, China) and from a ring road, with heavy traffic, have been sampled and analyzed for 31 storm events from June 2004 to August 2005. Total suspended solids (TSS), chemical oxygen demand (COD), 5-day biochemical oxygen demand (BOD5), total nitrogen, and total phosphorus concentrations in rainwater and runoff ranged over 2 or more orders of magnitude, meaning that the highest concentration of a certain pollutant did not always occur in a certain kind of runoff. Runoff contained significantly higher concentrations of pollutants than rainwater. On the campus of RCEES, TSS and total phosphorus in runoff samples from the lawn and roads were significantly higher than those from roofs, while the COD, BOD5, and total nitrogen concentrations were not significantly different in runoff among surfaces. Compared with runoff from the roads on campus, runoff from the ring road contained more COD and total nitrogen, but less TSS, BOD5, and total phosphorus. All pollutants measured in runoff from roofs on campus and from the ring road showed a peak concentration in starting runoff, which then decreased sharply. The peak concentrations of COD, BOD5, total nitrogen, and total phosphorus in the roof runoff increased with the increase in time of the antecedent dry period. Thus, urban stormwater pollution control, especially for first-flush control, is of great importance for the full use of rainwater and prevention of water pollution.  相似文献   

18.
Wang C  Yediler A  Lienert D  Wang Z  Kettrup A 《Chemosphere》2003,52(7):1225-1232
The effect of ozonation (20.5 mgl(-1)) on the degradation processes of an azo dye, Remazol Black 5 (RB5; CI) was studied. Conventional parameters such as chemical oxygen demand (COD), total organic carbon (TOC), pH, conductivity, colour removal, biodegradability (BOD(5/28)), and toxic potential of the dye and its degradation products were monitored during the process. The results obtained indicated that ozonation is a highly effective way to remove the colour of a corresponding dye solution. However, a considerable organic load still remained as indicated by high COD and TOC residues. The COD, TOC reductions were about 40% and 25% for 6 h ozonation of 2 gl(-1) RB5 aqueous solution. During the ozonation process the rapid decrease of pH and the sharp increase of conductivity indicated the formation of acidic by-products and small fragments and ions which were identified by high performance ion chromatography. The BOD28 data revealed that first by-products after partial ozonation (10-150 min) of RB5 were more biodegradable than the parent compound and ozonation can enhance the biodegradability of azo dyes. During the first 150 min of total 360 min of oxidation, the formation of first by-products with high toxic potential took place as it could be confirmed by two acute toxicity-screening tests, the bioluminescence test (Vibrio fischerii) and the neutral red cytotoxicity assay (rat hepatoma cells). The significant enhancement of microbial biodegradability after long-term ozonation could also be seen as a decrease of toxic intermediates in correlation with the ozonation time as indicated in BOD28 biological degradation test results.  相似文献   

19.
Although the long incubation time of biochemical oxygen demand (BOD7) measurements has been addressed by the use of microbial biosensors, the resulting sensor-BOD values gained from the measurements with specific industrial wastewaters still underestimates the BOD value of such samples. This research aims to provide fast and more accurate BOD measurements in the dairy wastewater samples. Unlike municipal wastewater, wastewater from the dairy industry contains many substrates that are not easily accessible to a majority of microorganisms. Therefore, a bacterial culture, Microbacterium phyllosphaerae, isolated from dairy wastewater was used to construct a semi-specific microbial biosensor. A universal microbial biosensor based on Pseudomonas fluorescens, which has a wide substrate spectrum but is nonspecific to dairy wastewater, was used as a comparison. BOD biosensors were calibrated with OECD synthetic wastewater, and experiments with different synthetic and actual wastewater samples were carried out. Results show that the semi-specific M. phyllosphaerae-based microbial biosensor is more sensitive towards wastewaters that contain milk derivates and butter whey than the P. fluorescens-based biosensor. Although the M. phyllosphaerae biosensor underestimates the BOD7 value of actual dairy wastewaters by 25–32 %, this bacterial culture is more suitable for BOD monitoring in dairy wastewater than P. fluorescens, which underestimated the same samples by 46–61 %.  相似文献   

20.
Ozonation of three different synthetic pharmaceutical formulation wastewater containing two human antibiotics and a veterinary antibiotic has been studied to enhance the their biodegradability. The effects of pH and initial chemical oxygen demand (COD) value as well as addition of hydrogen peroxide on ozonation process were investigated. Total organic carbon (TOC), COD, biochemical oxygen demand (BOD), and aromatic content (UV254) were the parameters followed to evaluate the performance of ozonation process. Comparison of the biodegradability of selected wastewaters containing different antibiotics confirmed that the variation of biodegradability was associated with the target compound. While BOD5/COD ratio of veterinary antibiotic formulation wastewater was increased from 0.077 to 0.38 with an applied ozone dosage of 2.96 g/l, this ratio for human antibiotic I and human antibiotic II was increased from 0 to 0.1 and 0.27 respectively. Moreover the results of this investigation showed that the ozonation process is capable of achieving high levels of COD and aromaticity removals at about their natural pH values.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号