首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
A laboratory-scale biofiltration system, the rotatory-switching biofilter (RSB), was operated for 199 days using toluene as a model pollutant. The target gaseous pollutant for the biofiltration experiment was approximately 300 ppmv of toluene. Toluene removal efficiency (RE, %) was initially approximately 20% with a 247-ppmv concentration (0.9 g m(-3)) of toluene during the first 10 days. Although the RE decreased several times whenever nitrogen was consumed, it again reached almost 100% when the nitrogen source was in sufficient supply. Denaturing gradient gel electrophoresis (DGGE) analysis was employed to assess the transformation ofmicroflora during operation of the biofilter The results based on a 16S rRNA gene profile showed that the microbial community structure changed with operation time. Although the microflora changed during the initial period (before day 40), transformation of the bacterial component was hardly observed after day 51. Statistical analyses of the DGGE profiles indicated that the bacterial community was almost unaffected by the environmental factors, such as adding ozone, high-level nitrogen supply, increase of loading toluene, and the shutdown of the RSB. The DGGE profile using tmoA-like genes, which encode proteins belonging to the hydroxylase component mono-oxygenases involved in the initial attack of aerobic benzene, toluene, ethylbenzene, and xylene degradation, confirmed the existence of toluene-degrading bacteria. There were at least four kinds of toluene-degradable bacteria having tmoA-like genes up to day 36, which decreased to two species after day 40. Sequence analysis after DGGE profiling revealed that Burkholderia cepacia, Sphingobacterium multivorum, and Pseudomonas putida were present in the biofilter. Only Alicycliphilus denitrificans was present throughout the whole operation period. In the initial stage of operating the RSB, many types of bacteria may have tried to adapt to the conditions, and subsequently, only selected bacteria were able to grow and to degrade toluene.  相似文献   

2.
Four different biofilter packing materials (two porous ceramics, perlite, and open pore polyurethane foam) were compared for the removal of toluene vapors. The focus was on evaluating performance at relatively short gas retention time (13.5 and 27 sec). The reactors were initially operated as biotrickling filters with continuous feeding and trickling of a nutrient solution. After significant plugging of the biotrickling filter beds with biomass was observed, the operation mode was switched to biofiltration with only periodic supply of mineral nutrients. This resulted in stable conditions, which allowed detailed investigations over > 6 months. The reactor packed with cattle bone Porcelite (CBP), a ceramic material containing some macronutrients and micronutrients, exhibited the highest performance. The critical load (i.e., load at which 95% removal occurred) was 29 g m(-3) hr(-1) at a gas retention time of 13.5 sec and 66 g m(-3) hr(-1) at a gas retention time of 27 sec. After the long-term experiment, the packing materials were taken from the reactors and examined. The reactors were divided into three sections, top, middle, and bottom, to determine whether spatial differentiation of biomass occurred. The assays included a double-staining technique to count total and live microorganisms and determination of moisture, protein, and dry weight contents. Microbial community analysis was also conducted by denaturing gradient gel electrophoresis. The results showed that most reactors had a significant fraction of inactive biomass. Comparatively, the CBP biofilter held significantly higher densities of active biomass, which may be the reason for the higher toluene removal performance. The analyses suggest that favorable material properties and the nutrients slowly released by the CBP provided better environmental conditions for the process culture.  相似文献   

3.
Trickle-bed air biofilters (TBABs) are suitable for treating volatile organic compounds (VOCs) at a significantly high practical loading because of their controlled environmental conditions. The application of TBAB for treating styrene-contaminated air under periodic backwashing and cyclical nonuse periods at a styrene loading of 0.64-3.17 kg chemical oxygen demand (COD)/m3 x day was the main focus of this study. Consistent long-term efficient performance of TBAB strongly depended on biomass control. A periodic in situ upflow with nutrient solution under media fluidization, that is, backwashing, was approached in this study. Two different nonuse periods were employed to simulate a shutdown for equipment repair or during weekends and holidays. The first is a starvation period without styrene loading, and the second is a stagnant period, which reflects no flow passing through the biofilter. For styrene loadings up to 1.9 kg COD/m3 x day, removal efficiencies consistently above 99% were achieved by conducting a coordinated biomass control strategy, that is, backwashing for 1 hr once per week. Under cyclical nonuse periods for styrene loadings up to 1.27 kg COD/m3 x day, stable long-term performance of the biofilter was maintained at more than 99% removal without employing backwashing. No substantial impact of nonuse periods on the biofilter performance was revealed. However, a coordinated biomass control by backwashing subsequently was unavoidable for attaining consistently high removal efficiency at a styrene loading of 3.17 kg COD/m3 x day. As styrene loading was increased, reacclimation of the biofilter to reach the 99% removal efficiency following backwashing or the nonuse periods was delayed. After the non-use periods, the response of the biofilter was a strong function of the biomass in the bed. No significant difference between the effects of the two different nonuse periods on TBAB performance was observed during the study period.  相似文献   

4.
The system performance of a trickle bed biofilter for treating single and mixed benzene, toluene, ethylbenzene, and o-xylene (BTEX) vapors from waste gases was investigated under different gas flow rates and influent BTEX concentrations. When a single substrate was fed, removal efficiencies of greater than 90% could be achieved for the loads below 64 g benzene/m3/hr, 110 g toluene/m3/hr, 53 g ethylbenzene/m3/hr, and 55 g o-xylene/m3/hr. When a mixed substrate was fed, removal efficiencies of each compound could be above 90% at BTEX loads below 96 g/m3/hr. The trickle bed biofilter appears to be an effective treatment process for removing both single and mixed BTEX vapors with low to high loads. Under similar substrate loads, BTEX vapors were preferentially biodegraded in the order of toluene, benzene, o-xylene, and ethylbenzene. The volumetric removal rates (elimination capacities) of BTEX vapors for a single-substrate feed were higher than those for a mixed-substrate feed under similar substrate loads; these differences were enhanced at higher substrate loads and less significant for a preferred substrate.  相似文献   

5.
Abstract

A laboratory-scale compost-based biofilter was operated over a six-month period to study the requirements for removal of n-hexane from air. Hexane is a relatively short chain aliphatic hydrocarbon with a high Henry's coefficient and a low water solubility. Acclimation of the biofilter was slow, but removal efficiencies around 80% were achieved after one month of operation. However, performance decreased during the next two months of operation to 50% removal efficiency. Nutrient limitation was proposed as a reason for the decrease in reactor performance. After the addition of a concentrated nitrogen solution, reactor performance increased almost immediately to >99%. Removal efficiency remained above 99% for the following two months of operation at inlet concentrations of 0.7 g/m3 (200 ppmv), at superficial bed velocities approaching 50 m/h, and empty bed residence times of about one minute. Thus, nutrient availability may well limit biofilter performance even in compost- based units. It was shown that nutrients can be added effectively in a soluble form if compost quality is poor and a method is proposed for the evaluation of compost quality.  相似文献   

6.
Biofiltration of gasoline vapor by compost media   总被引:2,自引:0,他引:2  
Gasoline vapor was treated using a compost biofilter operated in upflow mode over 4 months. The gas velocity was 6 m/h, yielding an empty bed retention time (EBRT) of 10 min. Benzene, toluene, ethylbenzene and xylene (BTEX) and total petroleum hydrocarbon (TPH) removal efficiencies remained fairly stable approximately 15 days after biofilter start-up. The average removal efficiencies of TPH and BTEX were 80 and 85%, respectively, during 4 months of stable operation. Biodegradation portions of the treated TPH and BTEX were 60 and 64%, respectively. When the influent concentration of TPH was less than 7800 mg TPH/m3, approximately 50% of TPH in the gas stream was removed in the lower half of the biofilter. When the influent concentration of BTEX was less than 720 mg BTEX/m3, over 75% of BTEX in the gas stream was removed in the lower half of the biofilter. Benzene removal efficiency was the lowest among BTEX. A pressure drop could not be detected over a 1-m bed height at a gas velocity of 6 m/h after approximately 4 months of operation. Results demonstrated that BTEX in gasoline vapor could be treated effectively using a compost biofilter.  相似文献   

7.
A high H2S concentration inhibits nitrification when H2S and NH3 are simultaneously treated in a single biofilter. To improve NH3 removal from waste gases containing concentrated H2S, a two-stage biofilter was designed to solve the problem. In this study, the first biofilter, inoculated with Thiobacillus thioparus, was intended mainly to remove H2S and to reduce the effect of H2S concentration on nitrification in the second biofilter, and the second biofilter, inoculated with Nitrosomonas europaea, was to remove NH3. Extensive studies, which took into account the characteristics of gas removal, the engineering properties of the two biofilters, and biological parameters, were conducted in a 210-day operation. The results showed that an average 98% removal efficiency for H2S and a 100% removal efficiency for NH3 (empty bed retention time = 23-180 sec) were achieved after 70 days. The maximum degradation rate for NH3 was measured as 2.35 g N day(-1) kg of dry granular activated carbon(-1). Inhibition of nitrification was not found in the biofilter. This two-stage biofilter also exhibited good adaptability to shock loading and shutdown periods. Analysis of metabolic product and observation of the bacterial community revealed no obvious acidification or alkalinity phenomena. In addition, a lower moisture content (approximately 40%) for microbial survival and low pressure drop (average 24.39 mm H2O m(-1)) for system operation demonstrated that the two-stage biofilter was energy saving and economic. Thus, the two-stage biofilter is a feasible system to enhance NH3 removal in the concentrated coexistence of H2S.  相似文献   

8.
Abstract

This study aimed to develop a biofilter packed only with fern chips for the removal of airborne propylene glycol monomethyl ether acetate (PGMEA). Fern chips could avoid the shortcomings of traditional media, such as compaction, drying, and breakdown, which lead to the performance failure of the biofilters. In addition, the fern chip medium has the following merits: (1) simplicity in composition; (2) low pressure drop for gas ?ow (<20 mmH2O?m-1); (3) simple in humidification, nutrient addition, pH control, and metabolite removal; (4) economical (US$174–385?m-3), and (5) low weight (wet basis around 290 kg?m-3). A two-stage down?ow biofilter (2.18 m in height and 0.4×0.4 m in cross-sectional area) was constructed for the performance test. Both stages were packed with fern chips of 0.30 m in height and 0.40×0.40 m in cross-section. Results indicate that with operation conditions of media moisture content controlled in the range of 50–74%, media pH of 6.5–8.3, empty bed retention time (EBRT) of 0.27–0.4 min, in?uent PGMEA concentrations of 100–750 mg?m-3, volu-metric organic loading of <170 ?m-3 ?hr-1, and nutrition rates of Urea-nitrogen 66 g?m-3 ?day-3, potassium dihydrogen phosphate (KH2PO4)-phosphorus 13.3 g ?m-3 ?day-3, and milk powder 1.00 g?m-3?day-1, the fern-chip-packed biofilter could achieve an overall PGMEA removal efficacy of around 94%. Instant milk powder or liquid milk was essential to the good and stable performance of the biofilter for PGMEA removal.  相似文献   

9.
Lee TH  Kim J  Kim MJ  Ryu HW  Cho KS 《Chemosphere》2006,63(2):315-322
With ketone pollution forming an ever-growing problem, it is important to identify a ketone-degrading microorganism and establish its effect. Here, a methyl ethyl ketone (MEK)-degrading bacterium, Pseudomonas sp. KT-3, was isolated and its MEK degradation characteristics were examined in liquid cultures and a polyurethane-packed biofilter. In liquid cultures, strain KT-3 could degrade other ketone solvents, including diethyl ketone (DK), methyl propyl ketone (MPK), methyl isopropyl ketone (MIPK), methyl isobutyl ketone (MIBK), methyl butyl ketone (MBK) and methyl isoamyl ketone (MIAK). The maximum specific growth rate (mumax) of the isolate was 0.136 h(-1) in MEK medium supplemented with MEK as a sole carbon source, and kinetically, the maximum removal rate (Vm) and saturation constant (Km) for MEK were 12.28 mM g(-1)DCW h(-1) (DCW: dry cell weight) and 1.64 mM, respectively. MEK biodegradation by KT-3 was suppressed by the addition of MIBK or acetone, but not by toluene. In the tested biofilter, KT-3 exhibited a>90% removal efficiency for MEK inlet concentrations of around 500 ppmv at a space velocity (SV) of 150 h(-1). The elimination capacity of MEK was more influenced by SV than by the inlet concentration. Kinetic analysis showed that the maximum MEK removal rate (Vm) was 690 g m(-3) h(-1) and the saturation constant (Km) was 490 ppmv. Collectively, these results indicate the polyurethane sequencing batch biofilter with Pseudomonas sp. KT-3 will provide an excellent performance in the removal of gaseous MEK.  相似文献   

10.
采用自行研制的生物转鼓过滤器(RDB)反硝化净化NO。结果表明,在实验温度为25~30℃、pH为7.0~7.5、转鼓转速为1.0r/min、空床停留时间(EBRT)为86.40s、营养液用量为5.0L、营养液更换频率为0.2L/d的条件下,RDB在30d内完成挂膜;RDB稳定运行期间,当NO进气质量浓度为90~433mg/m3时,NO去除率维持在42.9%~85.2%,平均去除负荷为10.40g/(m3.h);转鼓转速决定了生物膜表面的更新速率和液膜厚度,当转速为0.5r/min时,NO去除率达到最大值(75.0%);将营养液用量控制在1.3~3.0L较为合理;EBRT是决定反硝化效率的重要因素,当EBRT为345.60s时,NO去除率不受其进气浓度的影响,且去除率高达95%以上,当EBRT为43.20s、NO进气质量浓度从98mg/m3增加到1095mg/m3时,NO去除率从62.5%下降到30.7%,当进气负荷为50.00g/(m3.h)时,NO去除负荷达到最大值(27.50g/(m3.h))。  相似文献   

11.
Two biofilters were operated to treat a waste gas stream intended to simulate off-gases generated during the manufacture of reformulated paint. The model waste gas stream consisted of a five-component solvent mixture containing acetone (450 ppm(v)), methyl ethyl ketone (12 ppm(v)), toluene (29 ppm(v)), ethylbenzene (10 ppm(v)), and p-xylene (10 ppm(v)). The two biofilters, identical in construction and packed with a polyurethane foam support medium, were inoculated with an enrichment culture derived from compost and then subjected to different loading conditions during the startup phase of operation. One biofilter was subjected to intermittent loading conditions with contaminants supplied only 8 hr/day to simulate loading conditions expected at facilities where manufacturing operations are discontinuous. The other biofilter was subjected to continuous contaminant loading during the initial start period, and then was switched to intermittent loading conditions. Experimental results demonstrate that both startup strategies can ultimately achieve high contaminant removal efficiency (>99%) at a target contaminant mass loading rate of 80.3 g m(-3) hr(-1) and an empty bed residence time of 59 sec. The biofilter subjected to intermittent loading conditions at startup, however, took considerably longer to reach high performance. In both biofilters, ketone components (acetone and methyl ethyl ketone) were, more rapidly degraded than aromatic hydrocarbons (toluene, ethylbenzene, and p-xylene). Scanning electron microscopy and plate count data revealed that fungi, as well as bacteria, populated the biofilters.  相似文献   

12.
Long-term operation of biofilters for biological removal of ammonia   总被引:6,自引:0,他引:6  
Chen YX  Yin J  Wang KX 《Chemosphere》2005,58(8):1023-1030
Biological removal of ammonia was investigated using two types of packing materials, compost and sludge in laboratory-scale biofilters (8l reactor volume). The aim of this study is to investigate the potential of unit systems packed with these supports in terms of ammonia emissions treatment. Experimental tests and measurements included analysis of removal efficiency, metabolic products, and results of long-term operation. The inlet concentration of ammonia applied was 20-200 mg m-3. The ammonia loading rates of 24.9-566 g NH3 m-3 d-1 to compost biofilter (BF3) and 24.9-472 g NH3 m-3 d-1 to sludge biofilter (BF4) were applied for 210 days, respectively. Removal efficiencies of the compost and sludge biofilters were in the range of 97-99% and 95-99%, respectively when the inlet concentration of ammonia was below 110 mg m-3, and the maximum elimination capacities were 288 and 243 g NH3m-3d-1, respectively. However, removal efficiency and elimination capacity of both biofilters significantly decreased as the inlet concentration increased to above 110 mg m-3. By using kinetic analysis, the maximum removal rate of ammonia, Vm, and the saturation constant, Ks, were determined for both packing materials and the value of Vm for compost was found to be larger. Periodic analysis of the biofilter packing materials showed the accumulation of the nitrification product NO3- in the operation. During the experiment, the pressure drops measured were very low. The use of both packing materials requires neither nutritive aqueous solution nor buffer solution.  相似文献   

13.
The long-term stability of a biofilter loaded with waste gases containing NH3 concentrations larger than 100 ppmv was studied in a laboratory-scale compost reactor. At an empty bed residence time (tau) of 21 sec, elimination capacities of more than 300 g NH3/m3/day were obtained at elimination efficiencies up to 87%. Because of absorption and nitrification, almost 80% of the NH3-N eliminated from the waste gas could be recovered in the compost as NH4(+)-N or NO2-/NO3(-)-N. The high elimination capacities could be maintained as long as the NH4+/ NOX- concentration in the carrier material was less than 4 g NH4+/NOx(-)-N/kg wet compost. Above this critical value, osmotic effects inhibited the nitrifying activity, and the elimination capacity for NH3 decreased. To restore the biofilter performance, a carbon source (methanol) was added to reduce NH4+/NOx- accumulated in the compost. Results indicate that methylotrophic microorganisms did convert NH4+/NOx- into biomass, as long as the NO3- content in the compost was larger than 0.1 g NO3(-)-N/kg compost. Removal efficiencies of CH3OH of more than 90% were obtained at volumetric loads up to 11,000 g CH3OH/ m3/day. It is shown that addition of CH3OH is a suitable technique for regenerating the compost material from osmotic inhibition as a result of high NH3 loading. The biofilter was operated for 4 months with alternating load ing of NH3 and CH3OH.  相似文献   

14.
Simultaneous removal of H2S and CS2 was studied with a peat biofilter inoculated with a Thiobacillus strain that oxidizes both compounds in an acidic environment. Both sulfurous gases at concentrations below 600 mg S/m3 were efficiently removed, and the removal efficiencies were similar, 99%, with an empty bed retention time (EBRT) of more than 60 sec. Concentrations greater than 1300-5000 mg S/m3 caused overloading of the filter material, resulting in high H2SO4 production, accumulation of elemental sulfur, and reduced removal efficiency. The highest sulfur removal rate achieved was 4500 g-S/day/m3 filter material. These results indicate that peat is suitable as a biofilter material for the removal of a mixture of H2S and CS2 when concentrations of gases to be purified are low (less than 600 mg/m3), but it is still odorous and toxic to the environment and humans.  相似文献   

15.
The purpose of this research was to neutralize livestock-generated ammonia by using biofilters packed with inexpensive inorganic and organic packing material combined with multicultural microbial load at typical ambient temperatures. Peat and inorganic supporting materials were used as biofiltration matrix packed in a perfusion column through which gas was transfused. Results show the ammonia removal significantly fell in between 99 and 100% when ammonia concentration of 200 ppmv was used at different gas flow rates ranged from 0.030 to 0.060 m3 h(-1) at a fluctuating room temperature of 27.5 +/- 4.5 C (Mean +/- SD). Under these conditions, the emission concentration of ammonia that is liberated after biofiltration is less than 1 ppmv (0.707 mg m(-3)) over the period of our study, suggesting the usage of low-cost biofiltration systems for long-term function is effective at wider ranges of temperature fluctuations. The maximum (100%) ammonia removal efficiency was obtained in this biofilter was having an elimination capacity of 2.217 g m(-3) h(-1). This biofilter had high nitrification efficiencies and hence controlled ammonia levels with the reduced backpressure. The response of this biofilter to shut down and start up operation showed that the biofilm has a superior stability.  相似文献   

16.
A wheat straw biofilter was evaluated for attenuating pollutants in dairy (milkhouse and milking parlor) wastewater. During the 14-day study, the biofilter was operated in a sequential aerobic-anaerobic mode in a temperature range of 8-14 degrees C. While the biofilter was very effective (89% removal) in attenuating total suspended solids and moderately effective (76% removal) in attenuating oil and grease, its effectiveness in attenuating chemical oxygen demand was low (37% removal). The biofilter was ineffective in attenuating nitrate, while its effectiveness in attenuating ammonium (20% removal) and total Kjeldahl nitrogen (15% removal) was low. The biofilter was not effective in attenuating ortho-phosphate, total phosphorus, and fecal coliform. Though microbial degradation accounted for some pollutant removal, filtration seemed to be the primary mechanism. Lower temperature of operation and high oil and grease concentration (that reduced nutrient transfer to the biofilm) decreased microbial activity, reducing pollutant attenuation. Biofilter performance could be enhanced by using residual heat in the wastewater to raise the operating temperature of the biofilter and by removing oil and grease prior to applying the wastewater to the biofilter.  相似文献   

17.
Abstract

Four different biofilter packing materials (two porous ceramics, perlite, and open pore polyurethane foam) were compared for the removal of toluene vapors. The focus was on evaluating performance at relatively short gas retention time (13.5 and 27 sec). The reactors were initially operated as biotrickling filters with continuous feeding and trickling of a nutrient solution. After significant plugging of the biotrickling filter beds with biomass was observed, the operation mode was switched to biofiltration with only periodic supply of mineral nutrients. This resulted in stable conditions, which allowed detailed investigations over >6 months. The reactor packed with cattle bone Porcelite (CBP), a ceramic material containing some macronutrients and micronutrients, exhibited the highest performance. The critical load (i.e., load at which 95% removal occurred) was 29 g m?3 hr?1 at a gas retention time of 13.5 sec and 66 g m?3 hr?1 at a gas retention time of 27 sec. After the long-term experiment, the packing materials were taken from the reactors and examined. The reactors were divided into three sections, top, middle, and bottom, to determine whether spatial differentiation of biomass occurred. The assays included a double-staining technique to count total and live microorganisms and determination of moisture, protein, and dry weight contents. Microbial community analysis was also conducted by denaturing gradient gel electrophoresis. The results showed that most reactors had a significant fraction of inactive biomass. Comparatively, the CBP biofilter held significantly higher densities of active biomass, which may be the reason for the higher toluene removal performance. The analyses suggest that favorable material properties and the nutrients slowly released by the CBP provided better environmental conditions for the process culture.  相似文献   

18.
Kim JH  Rene ER  Park HS 《Chemosphere》2007,68(2):274-280
The performance of a lab scale biofilter packed with biomedia, encapsulated by sodium alginate and polyvinyl alcohol was used for treating ammonia (NH(3)) gas at different loading rates. The metabolic end products during NH(3) oxidation were NH(4)(+), NO(3)(-) and NO(2)(-). It is noteworthy to mention that the immobilized cell biofilter required no separate acclimatization period and showed high removal efficiencies during the start of continuous experiments. The removal efficiency was nearly 100% when ammonia loading was 4.5gm(-3)h(-1) and the maximum elimination capacity achieved in this study was 5.5gNH(3)m(-3)h(-1) at a loading rate of 7.5gm(-3)h(-1). Shock loading studies were carried out to ascertain the response of the immobilized cells to fluctuations in inlet concentration and flow rate. The inlet loading rates were varied between 0.05 and 6gNH(3)m(-3)h(-1) during this phase of operation. The biofilter responded effectively to these shock loading conditions and recovered rapidly within 4-8h. Pressure drop values were consistently less and insignificant. The results from this study indicated that this immobilized cell biofilter could be considered as a potential option to treat NH(3) under steady and transient state operation.  相似文献   

19.
Removal of ammonia from contaminated air by trickle bed air biofilters   总被引:6,自引:0,他引:6  
A trickle bed air biofilter (TBAB) was evaluated for the oxidation of NH3 from an airstream. Six-millimeter Celite pellets (R-635) were used for the biological attachment medium. The efficiency of the biofilter in oxidizing NH3 was evaluated using NH3 loading rates as high as 48 mol NH3/m3 hr and empty-bed residence times (EBRTs) as low as 1 min. Excess biomass was controlled through periodic backwashing of the biofilter with water at a rate sufficient to fluidize the medium. The main goal was to demonstrate that high removal efficiencies could be sustained over long periods of operation. Ammonia oxidation efficiencies in excess of 99% were consistently achieved when the pH of the liquid nutrient feed was maintained at 8.5. Quick recovery of the biofilter after backwashing was observed after only 20 min. Evaluation of biofilter performance with depth revealed that NH3 did not persist in the gas phase beyond 0.3 m into the depth of the medium (26% of total medium depth).  相似文献   

20.
Kim D  Sorial GA 《Chemosphere》2007,66(9):1758-1764
The effects of temporal and spatial changes in biological activity and biomass amount on biofilter performance were investigated in a lab-scale trickle-bed air biofilter at a toluene loading of 46.9gm(-3)h(-1) under two different experimental strategies, namely, periodic backwashing at a rate of 1h once a week and 2d starvation. Analysis of the overall reaction for toluene metabolism revealed that cell synthesis was relatively favored over toluene oxidation in the inlet section of the biofilter, but over time its oxidation became favored throughout the biofilter bed. Periodic in situ backwashing with media fluidization effectively made even spatial distribution of biomass along the bed media, by which consistent high removal performance in the biofilter has been attained. After 2d starvation, the ratio of the biofilm EPS to the total biomass increased along the media bed depth, while the total biomass in the media bed subsequently decreased. The presence of sufficient biomass and microbial activity favorably influenced biofilter reacclimation after restart-up following starvation.  相似文献   