首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Open burning for waste disposal is, in many countries, the dominant source of polychlorinated dibenzodioxins, dibenzofurans and biphenyls (PCDD/PCDF/PCB) release to the environment. To generate emission factors for open burning, experimental pile burns of about 100 kg of household waste were conducted with emissions sampling. From these experiments and others conducted by the same authors it is found that less compaction of waste or active mixing during the fire - “stirring” - promotes better combustion (as evidenced by lower CO/CO2 ratio) and reduces emissions of PCDD/PCDF/PCB; an intuitive but previously undemonstrated result. These experiments also support previous results suggesting PCDD/PCDF/PCB generation in open burning - while still highly variable - tends to be greater in the later (smoldering) phases of burning when the CO/CO2 ratio increases.  相似文献   

2.
Thuan NT  Tsai CL  Weng YM  Lee TY  Chang MB 《Chemosphere》2011,83(6):760-766
Twenty-one fresh water samples were taken from reservoirs, wells and drinking water treatment plants in Taiwan for measurement of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/F) concentrations. Due to low concentration of PCDD/Fs, water samples (400-1000 L) were collected by using the on-site large volume pre-concentration system and analyzed by high resolution gas chromatography (HRGC)/high resolution mass spectrometer (HRMS). Different characteristics of dioxin profiles in surface water and groundwater are observed. The PCDD/F concentrations in fresh water samples varied from 0.001 to 0.265 pg WHO98-TEQ/L which are lower than the standard (12 pg WHO98-TEQ/L) set by the Taiwan Environmental Protection Administration (TEPA) for drinking water. Only a small fraction (<5%) of the total PCDD/F concentration in fresh water samples was water-soluble. As a result of their hydrophobicity, PCDD/Fs are effectively removed along with suspended solid via the water treatment process (average 98% removal efficiency).  相似文献   

3.
Emission factors for PCDD/PCDF determined from open combustion are used to estimate national emission budgets; therefore, it is important to have confidence in their accuracy. It has been suspected that artefacts may form due to the presence of hot metal surfaces of sampling equipment, thus skewing emission factors. In this study, emissions of PCDD/PCDF from open burning of forest biomass over a brick hearth were sampled. Five experiments were carried out using a portable sampler. Experiments were designed where the key variable, sample hood and inlet temperatures were manipulated. Other variables such as fuel origin, type and density were consistent. The measured concentration of PCDD/PCDF in the smoke samples ranged from 0.01 μg TEQ (t fuel)−1 at the lowest maximum hood temperature (185 °C) to 15 μg TEQ (t fuel)−1 at the highest maximum hood temperature (598 °C). when hood inlet temperatures exceeded 400 °C emission factors were significantly elevated and this is attributed to the formation of artefacts that can cause the over estimation of emission factors. The increase in hood temperature also resulted in a change in the PCDD/PCDF congener and homologue profile of the emissions. For example at the lowest temperature (Fire 1) the PCDD/PCDF ratio measured was 50:1, whereas at the highest temperature (Fire 5) this ratio was about 0.53:1. When the sampler hood and inlet temperatures were kept in the normal operating range of <200 °C, emission factors were comparable to those observed in many previous studies in Australia with emissions dominated by PCDD.  相似文献   

4.
Open burning of waste is the most significant source of polychlorinated dibenzo-para-dioxins and dibenzofurans (PCDD/PCDF) in many national inventories prepared pursuant to the Stockholm Convention on Persistent Organic Pollutants. This is particularly true for developing countries. Emission factors for POPs such as PCDD/PCDF, dioxin-like polychlorinated biphenyls (dl-PCB) and penta- and hexachlorobenzenes (PeCBz/HCB) from open burning of municipal solid waste in China and Mexico are reported herein. Six different waste sources were studied varying from urban-industrial to semi-urban to rural. For PCDD/PCDF, the emission factors to air ranged from 3.0 to 650 ng TEQ kg−1 waste and for dl-PCB from 0.092 to 54 ng TEQ kg−1 waste. Emission factors for PeCBz (17-1200 ng kg−1 waste) and HCB (24-1300 ng kg−1 waste) spanned a wide but similar range. Within the datasets there is no indication of significant waste composition effect on emission factor with the exception of significantly higher Mexico rural samples.  相似文献   

5.
Taking into account current environmental concerns, the main objective of this work focused a national inventory aiming to estimate the amount of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/PCDF) released in Portugal in 2006. The methodology used was based on the Standardized Toolkit for Identification and Quantification of Dioxins and Furan Releases, developed by UNEP Chemicals, in 2005. The method allows the assessment of the amount of PCDD/PCDF released into the environment along five vectors involving air, water, land, products and residues. Facing some difficulties mainly regarding to the availability of data for some activities known to produce PCDD/PCDF, three scenarios (Sc1 to Sc3) corresponding to lower, central and upper estimates were established. The Sc1 scenario (lower estimate) includes the situations where in case of doubt or scarce information, reduced or none emission values were assumed, Sc2 refers to a central estimate, which is believed to be the most realistic for the Portuguese situation, while Sc3 corresponds to the worst case (upper estimate). The results obtained pointed out that the total amount of PCDD/PCDF emitted in Portugal during the period under analysis was in the range of 51.2-217.9 g TEQ year−1, with the most likely value of 95.2 g TEQ year−1 achieved under the Sc2 scenario. This study also showed that the methodology developed by UNEP Chemicals is a very simple one, and the main difficulty is the availability of data. The main indicators calculated in this study were 8.98 μg TEQ/(year person) by taking into account the total amount of PCDD/PCDF released, and 3.63 μg TEQ/(year person) when only air emissions were considered.  相似文献   

6.
There is a lack of information regarding persistent organic pollutants (POPs) in soil from Slovakia. This paper reports the concentrations of 17 polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), 12 dioxin-like polychlorinated biphenyls (dl-PCBs) and 6 indicator PCBs associated with 32 soil samples collected in 2007 from areas in the vicinity up to several kilometres from four selected industrial PCDD/F sources in Slovakia and one background area.The results show that the total WHO1998-PCDD/F/dl-PCB-TEQ concentrations varied from 0.34 to 18.05 pg g−1 dry weight (dw) and the average total TEQ concentrations in samples collected at the Šala, Košice, Krompachy and Dubová areas were 3.18, 2.64, 7.80, and 3.19 pg g−1 dw respectively. The average of the total WHO1998-TEQ values in three soil samples representing the background Starina area was 0.66 pg g−1 dw. The predominant contaminants among 2,3,7,8-substituted PCDD/Fs, dl-PCB, and indicator PCBs was OCDD, PCB 118, and PCB 153 respectively. The major contributors to the TEQ were 2,3,4,7,8-PeCDF, PCB 126, 1,2,3,7,8-PeCDD, PCB 156 and 1,2,3,4,7,8-HxCDF + 1,2,3,4,7,9-HxCDF in descending order.  相似文献   

7.
Measurements of the concentrations of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) were made in ambient air, ash, and soil impacted by the open burning of wax apple and rice straw residues. Measurements showed that the mean PCDD/F concentration (0.458 pg I-TEQ/Nm3; international toxicity equivalence) in air at two wax apple orchards during open burning increased markedly, -8.1 times higher than that (0.057 pg I-TEQ/Nm3); before open burning. In addition, the mean PCDD/F concentration (0.409 pg I-TEQ/Nm3) in ambient air at a rice straw field was 4.6 times higher than that (0.089 pg I-TEQ/Nm3) before open burning. After burning the residues of wax apple stubble and rice straw, the contents of PCDD/F in ashes were 1.393 and 1.568 ng I-TEQ/kg-ash, respectively, and the contents of PCDD/F in soil were 2.258 and 2.890 ng I-TEQ/kg-soil, respectively. Therefore, the turnover of soil with the ash after open burning over years will result in the accumulation of PCDD/Fs in farm soils.  相似文献   

8.
The concentrations of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), polychlorinated biphenyls (PCBs) and polybrominated diphenyl ethers (PBDEs) were determined in breast milk from women living in the vicinity of a hazardous waste incinerator (HWI) in Catalonia, Spain. The results were compared with the levels obtained in previous surveys carried out in the same area in 1998 (baseline study), 2002 and 2007. The current total concentrations of 2,3,7,8-chlorinated PCDD/Fs in breast milk ranged from 18 to 126 pg g−1 fat (1.1–12.3 pg WHO2005-TEQPCDD/F), while the total levels of PCBs ranged from 27 to 405 pg g−1 fat (0.7–5.3 pg WHO2005-TEQPCB). In turn, PBDE concentrations (sum of 15 congeners) ranged 0.3–5.1 g g−1 fat, with a mean value of 1.3 ng g−1 fat. A general decrease in the concentrations for PCDD/Fs, both planar and total PCBs, and PBDEs in breast milk was observed. The levels of PCDD/Fs, PCBs, and PBDEs in milk of women living in urban zones were higher than those corresponding to industrial zones (41%, 26%, and 8%, respectively). For PCDD/Fs and PCBs, the current decreases are in accordance with the reduction in the dietary intake of these pollutants that we have also observed in recent studies carried out in the same area of study.  相似文献   

9.
This study evaluates PCDD/F pollution in the surface sediments of Izmit Bay (Turkey) and assesses the possible sources of PCDD/F inputs to the bay. The results showed that concentrations of toxic PCDD/F congeners in the sediments varied between 0.45 and 255 ng WHO2005-TEQ/kg dry weight. Pollution mapping shows that PCDD/F levels in the central section of Izmit Bay are much higher than those in the eastern and the western sections. Sediments collected from the northern part of the central section showed very high PCDD/F concentrations. The samples reveal three different congener profiles dominated by OCDF, 1,2,3,4,6,7,8-HpCDF, and OCDD respectively. The dominance of OCDF in the sediment samples taken from the central section was attributed to the former production of vinyl chloride monomer in the area, while that of 1,2,3,4,6,7,8-HpCDF was attributed to the (previously unknown) use of a chlorophenol-based fungicide in the region. The OCDD dominated group was explained by the use of pentachlorophenol. The results indicate that historic industrial discharges are the main contributor to the PCDD/F pollution in the sediments.  相似文献   

10.
Hsu JF  Guo HR  Wang HW  Liao CK  Liao PC 《Chemosphere》2011,83(10):1353-1359
Polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) are unintentional byproducts of combustion and industrial processes. Firefighters face the risk of occupational exposure to PCDD/Fs. Congener-specific analyses of 17 PCDD/Fs were performed on 20 serum samples collected from firefighters and fire scene investigators, and four soot samples that had deposited on the surfaces of the fire helmets and were collected after the firefighters had fought fires. The PCDD/F concentrations on the helmets that were contaminated by being worn at the fire scenes were 63-285 times higher than those on a clean helmet. The median serum PCDD/F concentration of the 16 firefighters (12 pg WHO2005-TEQ g−1 lipid) was not different from those of the males from the general Taiwanese population (9.4 pg WHO2005-TEQ g−1 lipid). However, the median PCDD/F level in the four fire scene investigators (15 pg WHO2005-TEQ g−1 lipid) was higher than those in the male from the general Taiwanese population (Mann-Whitney U test, p < 0.01). Furthermore, the serum samples from the firefighters and fire scene investigators, and the soot samples from the fire scenes presented similarly distinctive PCDD/F profiles that had elevated proportions for 10 PCDF congeners. Limited data indicated that the fire scene investigators were occupationally exposed to PCDD/Fs at the fire scenes. We suggested that the firefighters were not occupationally exposed to PCDD/Fs at the fire scenes due to appropriate protection. However, the fire scene investigators may have had more occupational exposure to PCDD/Fs due to poor protection, and further research must be performed to confirm this.  相似文献   

11.
Polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDF) were determined in air at the inlet and outlet of a longitudinally ventilated tunnel with separate tubes for each traffic direction. In addition, measurements of traffic density, traffic composition, ventilation rate and other air pollutants were carried out. The data allowed to estimate the PCDD/PCDF emissions based on a car fleet of about 20'–30'000 cars. Furthermore, the varying percentage of heavy duty vehicles made it possible to differentiate between emission factors for light (LDV) and heavy duty (diesel) vehicles (HDDV). Depending on driving conditions, the estimated emission factors were in the order of 0.04–0.5 ng/km 2,3,7,8-TEQ (Nordic model) for LDV and 0.8–9.5 ng/km for HDDV.  相似文献   

12.
Both long duration (>6 h) and high temperature (up to 139 °C) sampling efforts were conducted using ambient air sampling methods to determine if either high volume throughput or higher than ambient air sampling temperatures resulted in loss of target polychlorinated dibenzodioxins/dibenzofurans (PCDDs/PCDFs) from a polyurethane foam (PUF) sorbent. Emissions from open burning of simulated military forward operating base waste were sampled using EPA Method TO-9A for 185 min duration using a filter/PUF/PUF in series combination. After a 54 m3 sample was collected, the sampler was removed from the combustion source and the second PUF was replaced with a fresh, clean PUF. An additional 6 h of ambient air sampling (171 m3) was conducted and the second PUF was analyzed to determine if the PCDD/PCDF transferred from the filter and the first PUF. Less than 4.4% of the initial PCDD/PCDF was lost to the second PUF. To assess the potential for blow off of PCDD/PCDF analytes during open air sampling, the mobility of spiked mono- to hepta-PCDD/PCDF standards across a PUF sorbent was evaluated from ambient air temperatures to 145 °C with total volumes between 600 L and 2400 L. Lower molecular weight compounds and higher flow amounts increased release of the spiked standards consistent with vapor pressure values. At 600 L total sampled volume, the release temperature for 1% of the tetra-CDD (the lowest chlorinated homologue with a toxic compound) was 87 °C; increasing the volume fourfold reduced this temperature to 73 °C.  相似文献   

13.
Liu HM  Lu SY  Buekens AG  Chen T  Li XD  Yan JH  Ma XJ  Cen KF 《Chemosphere》2012,86(3):300-307
In order to determine the baseline contamination by polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) in different areas in China, prior to the construction of municipal solid waste incinerators (MSWIs), a total of 32 representative soil samples was collected near 16 incinerators and analyzed for their PCDD/F concentrations. The PCDD/F baseline concentrations in the soil samples ranged from 0.32 to 11.4 ng I-TEQ kg−1 (dry matter), with average and median value of 2.73 and 2.24 ng I-TEQ kg−1 (dry matter), respectively, and a span between maximum and minimum recorded value of 36. The PCDD homologues predominated in 26 out of 32 soil samples, with the ratio (PCDDs)/(PCDFs) ranging from 1.1 to 164; however in the other 6 samples, PCDF homologues were larger, with the same ratio varying from 0.04 to 0.8. Principal component analysis (PCA) and hierarchical cluster analysis (HCA) were used to examine PCDD/F amount and profile in these soil samples, and their possible associations with known emission sources: in this process 6 really distinct isomer fingerprints were identified. Background PCDD/F levels and profiles were comparable to those found in soils from China and other countries and indicate a rather low baseline PCDD/F contamination of soils. The present data provide the tools for future assessment of a possible impact of these MSWIs.  相似文献   

14.
Release of PCDD and PCDF from biomass combustion such as forest and agricultural crop fires has been nominated as an important source for these chemicals despite minimal characterisation. Available emission factors that have been experimentally determined in laboratory and field experiments vary by several orders of magnitude from <0.5 μg TEQ (t fuel consumed)−1 to >100 μg TEQ (t fuel consumed)−1. The aim of this study was to evaluate the effect of experimental methods on the emission factor.A portable field sampler was used to measure PCDD/PCDF emissions from forest fires and the same fuel when burnt over a brick hearth to eliminate potential soil effects. A laboratory burn facility was used to sample emissions from the same fuels. There was very good agreement in emission factors to air (EFAir) for forest fuel (Duke Forest, NC) of 0.52 (range: 0.40-0.79), 0.59 (range: 0.18-1.2) and 0.75 (range: 0.27-1.2) μg TEQWHO2005 (t fuel consumed)−1 for the in-field, over a brick hearth, and burn facility experiments, respectively. Similarly, experiments with sugarcane showed very good agreement with EFAir of 1.1 (range: 0.40-2.2), 1.5 (range: 0.84-2.2) and 1.7 (range: 0.34-4.4) μg TEQ (t fuel consumed)−1 for in-field, over a brick hearth, open field and burn facility experiments respectively. Field sampling and laboratory simulations were in good agreement, and no significant changes in emissions of PCDD/PCDF could be attributed to fuel storage and transport to laboratory test facilities.  相似文献   

15.
A nationwide investigation into polychlorinated dibenzo-p-dioxins/furans (PCDD/Fs), polychlorinated biphenyls (PCBs), and polybrominated diphenyl ethers (PBDEs) in market seafood was conducted for the first time in this study. Total PCDD/F concentrations in fatty fish ranged from 0.13 to 8.64 pg g−1 wet weight (mean 2.05 pg g−1 wet weight), total PCB concentrations ranged from 38.9 to 3514 pg g−1 wet weight (mean 1133 pg g−1 wet weight), and total PBDE concentrations ranged from 42.8 to 913 pg g−1 wet weight (mean 322 pg g−1 wet weight). Corresponding mean toxicity equivalent (TEQ) values for total PCDD/F and dioxin-like PCB were 0.25 pg g−1 wet weight (WHO 98-TEQ) and 0.32 pg g−1 wet weight (WHO 98-TEQ), respectively. OCDD, PCB-138 and PBDE-47 were the dominant compounds according to their respective congeners. WHO 98-TEQ PCDD/PCDF/PCB for fatty fish and shell fish were 0.60 and 0.070 pg g−1 wet weight, respectively, lower than the standard set by the European Commission. The contamination levels and profiles were compared with those documented in previous publications.  相似文献   

16.
In April 1996 and 1998, the concentrations of polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) were determined in 40 herbage samples collected in the neighborhood of a hazardous waste incinerator (HWI) under construction in Constanti (Catalonia, Spain). In April 2000, 20 months after the HWI began operating, herbage samples were again collected at the same sampling points in which samples had been taken in the previous surveys. PCDD/F concentrations ranged between 0.13 and 0.65 ng I-TEQ/kg (dry matter), with a median and mean values of 0.29 and 0.32 ng I-TEQ/kg (dry matter), respectively. The results were compared with those obtained in the 1996 (median, 0.53 ng I-TEQ/kg; mean, 0.61 ng I-TEQ/kg) and the 1998 (median, 0.23 ng I-TEQ/kg; mean, 0.31 ng I-TEQ/kg) surveys. While in the period 1996-1998 a significant decrease (49%, P < 0.001) in the mean PCDD/F levels was noted, in the period 1998-2000 an increase of 3% (P > 0.05) was found in the concentrations of PCDD/Fs. The analysis of the results suggests two potential hypotheses: either the emissions of PCDD/Fs from the HWI are not negligible, or the current PCDD/F emissions from other sources near the HWI remained at similar levels to those reached in 1998. Anyhow, an exhaustive evaluation of the present data shows an absence of notable PCDD/F contamination by the HWI in the area under its direct influence. It seems also probable that the decline in the atmospheric levels of PCDD/Fs due other emission sources of PCDD/Fs in this area is currently stopped.  相似文献   

17.
PCDD/PCDF,chlorinated pesticides and PAH in Chinese teas   总被引:5,自引:0,他引:5  
Fiedler H  Cheung CK  Wong MH 《Chemosphere》2002,46(9-10):1429-1433
Four samples of Chinese tea (two green teas, and two brick teas) were analyzed for their concentrations of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/PCDF), chlorinated pesticides and PAH. The infusions prepared from these teas were also analyzed for PCDD/PCDF. The levels of DDT and its metabolites in tea leaves were within the safety limit of 0.2 mg/kg. Rather high levels of total PAH were obtained in brick tea (1048–1162 mg/kg), when compared with green tea (497–517 mg/kg). In terms of PCDD/PCDF, the concentrations of green tea and brick tea differed by a factor of 16, while the concentrations of all infusions were within a factor of 2. The dioxin concentrations in green tea leaves can be explained through uptake of atmospheric PCDD/PCDF. The higher concentrations in the brick tea leaves are due the longer exposure time, and to certain extent, the use of old leaves, branches and roots when making the tea, and additional components such as soil particulates through contamination. Certain Chinese populations drinking a large amount of brick tea (>3 l per day) indicated that individuals of these populations consume more tea than Europeans or North Americans result in a comparably higher intake of PCDD/PCDF. Tea consumption can attribute to up to 10% of the TDI recommended by WHO (only PCDD/PCDF considered, no PCB analyzed).  相似文献   

18.
Zhang B  Zhang H  Jin J  Ni Y  Chen J 《Chemosphere》2012,88(7):798-805
Polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) are ubiquitous contaminants and can be considerably accumulated by natural plants. In order to elucidate the biochemical and physiological responses of plant to PCDD/Fs, tobacco Bright Yellow-2 (BY-2) cells were selected as model plant and treated with time- and concentration-dependent PCDD/Fs. The toxic effect and oxidative stress caused by PCDD/Fs were evident, which could be indicted by the reduction in fresh mass, the increase in malondialdehyde (MDA) content, and the damage of tobacco cell ultrastructure. PCDD/Fs tolerance was correlated with changes in antioxidant system and hormones of tobacco cells. Superoxide dismutase (SOD) and peroxidase (POD) exhibited peak enzyme activities at the PCDD/Fs concentration of 1000 ng WHO98-TEQ g−1 fresh weight. Glutathione reductase (GR) enzyme activity increased monotonically at high level PCDD/Fs, but the activity of catalase (CAT) was only slightly affected at all treatment. Meanwhile, the exposure to PCDD/Fs resulted in the changes of hormones content. With the increase of exposure concentration of PCDD/Fs, the levels of indole-3-acetic acid (IAA) and abscisic acid (ABA) increased, whereas the concentration of jasmonates (JAs) decreased. The above results suggest that tobacco cells had the ability to cope with the oxidative stress induced by low concentration of PCDD/Fs through increasing the activities of antioxidant enzymes and alternating plant hormones levels. However, oxidative stress and toxicity would burst out when plant cells were exposed to the high levels of PCDD/Fs.  相似文献   

19.
Fu J  Wang T  Wang P  Qu G  Wang Y  Zhang Q  Zhang A  Jiang G 《Chemosphere》2012,88(3):330-335
Primitive e-waste dismantling activities have been of increasing concern due to serious environmental and human health problems, and therefore authorities in China have strengthened the regulations on illegal e-waste recycling activities. In this work, we used rice hull as a passive sampler and investigated temporal trends of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), polychlorinated biphenyls (PCBs), polybrominated diphenyl ethers (PBDEs) in areas near e-waste recycling sites after the stricter regulations. Furthermore, the distribution patterns and composition profiles of these contaminants were also discussed. The average concentrations of the three groups of persistent organic pollutants (POPs) in rice hulls have markedly decreased during the period of 2005-2009. Specifically, from 12.9 (average value in 2005) to 0.37 pg WHO-TEQ/g (dry weight, dw) (in 2009) for PCDD/Fs, 47.6 (2005) to 7.10 ng g−1 dw (2009) for PCBs, and 2.51 (2005) to 0.89 ng g−1, dw (2009) for PBDEs. The significant decrease of combustion markers 2,3,4,7,8-PeCDF, 1,2,3,6,7,8HxCDF and PCB126, and the PCDD/PCDF ratio from 1:9 (2005) to 7:3 (2009) is likely a result of stricter regulations on open combustion activities. This study suggests that stricter control measures, strengthened laws and regulations and more environmental friendly techniques could be effective measures in reducing the release and formation of related POPs in typical e-waste dismantling sites, and these measures could further improve the quality of the environment and health of the local inhabitants.  相似文献   

20.
Lv P  Zheng M  Liu G  Liu W  Xiao K 《Chemosphere》2011,82(5):759-763
The iron foundry industry is considered to be a potential source of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). This study investigated the emission factors and total emission amounts of PCDD/Fs and dioxin-like polychlorinated biphenyls (DL-PCBs) from iron foundries in China. The concentrations and the World Health Organization toxicity equivalents (WHO-TEQs) are presented and the congener profiles are discussed in this paper.In the present work, 26 fly ash samples were collected and tested to quantify the PCDD/Fs and DL-PCBs generated by 14 plants of different scales, and five stack gas samples were collected from two (named as EFG and LFG) of those plants. The emission levels of PCDD/Fs and DL-PCBs indicated that hot-air cupolas had lower emissions than cold-air cupolas. When iron ore lump and sinter were used as raw material, the emission factors were about 250 ng TEQ t−1 of product. However, if the raw material was scrap, the emission factors varied owing to the different contents of organic materials in the raw materials. It was found that the mean WHO-TEQ values of PCDD/Fs and DL-PCBs were 144 and 34.2 pg Nm−3 in stack gas and 20.0 and 1.58 pg g−1 in fly ash. In multiple tests, it was estimated that the mean emission factors of PCDD/Fs and DL-PCBs were 365 and 10.9 ng WHO-TEQ t−1 released to residue and 2719 and 555 ng TEQ t−1 released to air. The total emission amounts of PCDD/Fs and DL-PCBs from Chinese iron foundries with cupola furnaces released to residue and air were 16.8 and 146 g WHO-TEQ in 2008, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号