Combustion experiments in a laboratory-scale fluidized-bed reactor were conducted to elucidate the effects of copper chloride as a catalyst on polychlorinated dibenzo-p-dioxins (PCDDs) formation in municipal waste incineration. We used model wastes with and without copper chloride (CuCl2 · 2H2O), both of which contained polyvinyl chloride as a chlorine source. Combustion temperature was set to 900 °C, and the amount of air supplied was twice the stoichiometric ratio. The experimental setup was carefully planned to suppress the influences of experimental conditions except the waste composition. Results of these experiments showed that copper chloride in the waste increased the amount of PCDDs formed and made the homologue profile to shift towards the highly chlorinated species. Copper chloride contributes to the PCDDs formation by promoting chlorination, whereby the reaction is important in that organic matter is chlorinated directly by copper compounds. Copper chloride did not exert a great influence on the isomer distribution patterns of PCDDs, while there appeared a significant difference in the case of PCDFs. This points out the difference of the major formation mechanisms between PCDDs and PCDFs. PCDDs are less formed by the catalytic reactions from carbon/polycyclic aromatic hydrocarbons than PCDFs in our experimental conditions.  相似文献   

2.
Combustion experiments in a laboratory-scale fluidized-bed reactor have been performed to clarify the effects of copper chloride as a catalyst on polychlorinated dibenzofurans (PCDFs) formation in municipal waste incineration. We used model wastes with and without copper chloride (CuCl2 x 2H2O) as a catalyst, both of which contained polyvinyl chloride (PVC) as a chlorine source. Combustion temperature was set to 900 degrees C, and the amount of air supplied was twice as much as the theoretical amount. The experimental setup had been carefully planned to ensure avoidance of the influences of previous experiments. Results of these present experiments revealed that copper chloride in the waste increased the amount of PCDFs formed and made the homologue profile shifted towards the highly chlorinated species. Copper chloride contributes to PCDFs formation by promoting chlorination via catalytic reactions, whereby the reaction could be important in that organic matters are chlorinated directly by chlorinated compounds related to Deacon reaction such as copper chloride. It was elucidated that characteristic isomer distribution patterns appeared in case the waste contained copper chloride. It is probable in our experiment with copper chloride that PCDFs are mainly formed via catalytic reactions of copper compounds and carbon.  相似文献   

3.
Yasuhara A  Katami T  Shibamoto T 《Chemosphere》2006,62(11):1899-1906
Polyvinylidene chloride (PVDC; polymer of 1,1-dichloroethylene) was combusted with paper in a well-controlled, small-scale incinerator at an average grate temperature of 700 °C, and then dioxins (PCDDs, PCDFs, and coplanar-PCBs) formed in the exhaust gases were analyzed by gas chromatography/mass spectrometry. PVDC lowered the combustion temperature due to its less flammable character. The amount of total dioxins (PCDDs + PCDFs + coplanar-PCBs) formed in the exhaust gas was 58.0 ng/g of a combustion sample and its toxicity equivalency quantity (TEQ) value was 0.64 ng-TEQ/g. The amount of PCDDs formed in the sample ranged from 2.33 ng/g (Cl8-isomer) to 0.048 ng/g (Cl1-isomer). The lower the number of chloride, the less production of PCDDs. On the other hand, there was no relation between the number of chloride and PCDF formation. The amount of PCDFs formed in the sample ranged from 8.02 ng/g (Cl2-isomer) to 4.46 ng/g (Cl8-isomer). A polyvinylchloride (PVC) sample produced 207 ng/g of total dioxins and a PVDC sample produced 57.4 ng/g of total dioxins when they were combusted under the same conditions. An approximately equal composition of dioxin isomers was formed from PVDC and PVC samples. Paper was found to contribute to PCDF formation when it was combusted with plastics.  相似文献   

4.
An experiment was carried out to decompose chlorinated dioxins (PCDDs, PCDFs) Chlorobenzenes, NOx and odourous compounds (H2S, CH4S, C2H6S2, C8H8, C2H6S, C2H4O, NH3) simultaneously using a catalyst in the MSW incineration plant. The experiments were conducted at temperatures from 200°C to 400°C and from 3000h−1 to 6000h−1 at space velocity. A catalyst containing V2O5 and WO3 on the basis of TiO2 is used, an oxidizing catalyst of the honeycomb type. The average decomposition efficiencis were 95%, 98%, 92% for PCDDs(48CDDs), PCDFs(48CDFs) and Chlorobenzenes(36CLBs) at a reaction temperature of 350°C and a space velocity of 3000h−1, more than 90% for NOx at a reactiont temperature of 300°C and more than 80% for odourous compounds at the reaction temperature of 300°C and a space velocity of 6000h−1. All those compounds were decomposed successfully with increasing contact time and surface. The rate-determing step was the chemical reaction of catalyst surface.  相似文献   

5.
Two samples of tab water and double distilled water were chlorinated using chlorine gas. A series of PCDFs could be identified from these experiments, however no PCDDs could be found. The two water samples gave very similar isomeric patterns ( . . tetra-CDFs), however the congener profile (Cl4 --- Cl8) was different. These experiments indicate that all products formed by chlorination reactions are potentially contaminated by PCDFs by a specific “chlorine pattern”.  相似文献   

6.
A limited amount of information exists regarding the relationship between the chemical form of copper and the formation of chlorinated aromatics in fly ash. To understand the effects of the various forms of copper on the formation of chlorinated aromatics in real fly ash, we determined the chemical forms of copper present in various types of real fly ash using X-ray absorption near edge structure (XANES) and evaluated the relationship between the chemical forms of copper and the formation of chlorinated aromatics. Copper chloride hydroxide (CuCl2 x 3Cu(OH)2) and cuprous chloride (CuCl) were the predominant copper species found in real fly ash. Although pure cupric chloride (CuCl2) is known to be the most active catalyst for the formation of chlorinated aromatics under experimental conditions with synthetic fly ash, CuCl2 was not found in every real fly ash sample. The amount of copper chloride hydroxide was positively correlated with the formation of chlorinated aromatics in real fly ash and is, consequently, considered to be one of the key species involved in the formation of chlorinated aromatics.  相似文献   

7.
In this paper the results of sampling for trace chlorinated organics at two municipal refuse incinerators in Ontario are presented. The information may be of Interest to individuals concerned with the assessment of PCDD/PCDF (polychlorinated dibenzo-p-dioxin/polychlorinated dibenzofuran) emissions from incineration of refuse and their impact on the energyfrom- waste program. PCDDs, PCDFs, PCBs (polychlorinated biphenyls), CBs (chlorobenzenes) and CPs (chlorophenols) were quantified in all process streams including refuse, ash and stack emissions. Manual sorting of refuse and collection of ash samples were carried out simultaneously with three 24-hour continuous stack sampling tests at each plant. The results suggested that the total output of PCDDs and PCDFs varied proportionately with their input at both incinerators. However, the input of PCDDs/PCDFs could not account for their total output. The chemistry of PCDDs/PCDFs in the input and output streams were different in that only heptachlorinated and octachlorinated species were present in significant quantities in the refuse while lower chlorinated species were predominant in stack emissions and ash streams. There was no correspondence between the Input of PCBs/CBs/CPs and the output of PCDDs/PCDFs. The output of PCDDs/PCDFs, however, varied Inversely with the total output of PCBs/CBs/CPs, suggesting that the latter compounds could have been partially responsible for the formation of PCDDs and PCDFs. The PCDF emissions were also affected by combustion conditions; they were higher in magnitude and consisted of predominantly tetrachlorinated and pentachlorinated species at the plant where the combustion temperatures were lower.  相似文献   

8.
Studies on the formation of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) during the electrolysis of sodium chloride solution (brine) using graphite or titanium electrodes were carried out at a laboratory scale. High concentrations of PCDFs but no PCDDs were formed in tests using graphite electrodes. With titanium electrodes, PCDFs were only formed when tar pitch was added and mainly originated from the dibenzofuran present in the tar. For the first time, a detailed assessment of the formation of mono- to octachlorinated PCDD/PCDF from tar pitch was investigated. The assessment included of the chlorination steps proved that PCDFs were formed by successive lateral chlorinated from dibenzofuran to MonoCDFs, DiCDFs, and TriCDFs to form the typical known “chlorine pattern” of TetraCDF to OctaCDF with a dominance of 1,2,7,8- and 2,3,7,8-TetraCDFs, 1,2,3,7,8-PentaCDF, and 1,2,3,4,7,8-HexaCDF as marker congeners. The final homologue distributions depended on reaction time and reaction temperature. In addition, electrolysis with non-chlorinated dibenzo-p-dioxins, dibenzofuran, and biphenyl was carried out. As a result, PCDDs, PCDFs, and PCB were formed at comparable yields. Congener patterns in soil samples from a PCDD/F-contaminated site where chlor-alkali electrolysis had been operated for decades in Japan had identical isomer distribution demonstrating the source and contamination potential and risk of these processes. Therefore, sites where in the past 120 years chlor-alkali electrolysis has been operated or where residues from chlor-alkali production or other chlorine using industries have been disposed should be assessed for their pollution level and exposure relevance. The assessment of total organohalogen content revealed that PCDF is only a small fraction of organohalogens in the contaminated soils. For an appropriate risk assessment, also other chlorinated aromatic compounds such as PCBs or PCNs need to be considered.  相似文献   

9.
The catalytic effects of copper and iron compounds were examined for their behavior in promoting formation of chlorine (Cl2), the major chlorinating agent of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs), in an environment simulating that of municipal waste fly ash. Formation of Cl2 occurred as a result of a metal-catalyzed reaction of HCl with O2. Catalytic activity was greatest at a temperature of approximately 400 °C, supporting a theory of de novo synthesis of PCDDs and PCDFs on fly ash particles downstream of waste combustion.  相似文献   

10.
Weber R  Hagenmaier H 《Chemosphere》1999,38(3):529-549
The pyrolysis of chlorinated phenates at a temperature of about 280 degrees C results in the formation of definite chlorinated dibenzodioxin (PCDD) congeners [1-3]. It is shown that in gas phase reactions chlorophenols react in the presence of oxygen above 340 degrees C not only to PCDD but also to chlorinated dibenzofurans (PCDF). The mechanism of this reaction of chlorophenols to PCDD and PCDF was elucidated. In a first step phenoxyradicals are formed which are capable of forming PCDDs and PCDFs. This is confirmed by the oxygen dependency of the reaction. In an argon atmosphere no dimerization of chlorophenols could be observed at 420 degrees C. By the identification of intermediates and by analyzing the PCDF isomers formed from individual chlorophenols the reaction pathway is elucidated. As intermediates in the formation of PCDFs polychlorinated dihydroxybiphenyls (DOHB) were identified. These are most likely formed by the dimerization of two phenoxy radicals at the hydrogen substituted carbons in ortho-positions under simultaneous movement of the hydrogen atoms to the phenolic oxygen PCDDs are formed in the gas phase via ortho-phenoxyphenols (POP) analogous to the pyrolysis of phenates, but due to the radical mechanism in the first condensation step to POPs not only a chlorine atom is capable for substitution but also the hydrogen atoms. The formation of the DOHBs and their condensation to PCDFs and hydroxylated PCDFs as well as the ratio of PCDD to PCDF formed show a strong dependency on the reaction temperature, the substitution pattern of the chlorophenols and the oxygen concentration.  相似文献   

11.
Formation characteristics of PCDD and PCDF during pyrolysis processes   总被引:1,自引:0,他引:1  
In recent years, pyrolysis processes have become technologies developed to industrial scale and discussed as alternatives to the existing waste combustion technology. However, little information is published regarding PCDD/F formation characteristics during pyrolysis processes. Two common shredder fractions – industrial light shredder (ILS) and refrigerators (REF) – both with high chlorine and copper content were pyrolysed for this pyrolysis study using a pilot plant with a capacity of 100 kg/h. At oxygen concentrations below 2% and temperatures between 430°C and 470°C, considerable amounts of PCDD/F were formed during the pyrolysis. More than 90% of total TEQ was found in the oil fraction (gas phase). The PCDD/PCDF ratio and the homologue pattern differed significantly from those formed during waste incineration. Considering mono- to octachlorinated congeners, up to 400 times more PCDF were formed compared to PCDD. For the investigated pyrolysis conditions, the formation of low chlorinated congeners was highly favoured. The distribution of TEQ within the individual congeners were very similar in all investigated runs. More than 80% of total TEQ stem from 2,3,7,8-substituted T4CDF and P5CDF. The isomer pattern, however, did not show significant differences compared to the common waste incineration pattern suggesting that the basic formation routes are similar.  相似文献   

12.
Moon HB  Lee SJ  Choi HG  Ok G 《Chemosphere》2005,58(11):1525-1534
Bulk atmospheric samples (wet and dry) were collected monthly throughout a year at urban and suburban areas of Korea to assess the deposition flux and seasonal variations of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs). The PCDDs/DFs deposition fluxes ranged from 1.0 to 3.7 ng TEQ/m2/year in the urban area and from 0.5 to 4.6 ng TEQ/m2/year in the suburban area. The deposition fluxes of PCDDs/DFs in this study were comparable to or lower than those previously reported at different locations. The atmospheric deposition fluxes of particles and PCDDs/DFs in winter tended to be higher than those in summer. However, monthly variations between particle and PCDDs/DFs deposition fluxes were small, and the correlation coefficients between the deposition fluxes of air particles and each homologue group of PCDDs/DFs varied according to the degree of chlorination of the homologue group. The deposition velocity of PCDDs/DFs in the urban area was estimated at 0.04 cm/s, which is a lower value than those found in other studies. The two most likely factors affecting the monthly variation of deposition fluxes are the ambient temperature and the amount of precipitation. In particular, the ambient temperature had an influence on the lower chlorinated homologues of PCDDs/DFs while precipitation had an influence on the higher chlorinated PCDDs/DFs. The PCDDs/DFs profiles in atmospheric deposition bulk samples showed a similar pattern at the urban and suburban sites. The possibility of the loading of PCDDs/DFs by Asian dust events could be partly confirmed by investigation of homologue profiles.  相似文献   

13.
Sewage sludges and sediments of rivers and lakes are sinks for “persistent” organic compounds entering the environment. These matrices are therefore useful in the assessment of local and global pollution with certain compounds or classes of compounds. In recent years we have analyzed sediments of the rivers Neckar, Rhine, and Danube, from Lake Constance, and samples of sewage sludge from municipal waste water treatment plants of south-west Germany for PAH, phthalates, organochlorine pesticides, and PCBs. 1 We have now analyzed a number of these samples for PCDDs and PCDFs. Isomer-specific analyses for 2,3,7,8-subsituted PCDDs/PCDFs were carried out in all cases.

In all samples PCDDs could be detected, and in most cases PCDFs as well. 2,3,7,8-TCDD was never detected at a detection limit of 0.01 ppb. In sediments (14 samples) the total PCDDs ranged from 0.1 to 2.9 ppb and PCDFs from “not detectable” to 1.2 ppb. The highest concentration for a 2,3,7,8-substituted PCDD* was found for 1,2,3,6,7,8-hexaCDD with 0.06 ppb. In sewage sludges (15 samples) the total PCDDs ranged from 4 to 65 ppb and PCDFs from 1 to 7 ppb. The highest concentration for a 2,3,7,8-substituted PCDD* was found for 1,2,3,6,7,8-hexaCDD with 0.57 ppb.

Comparison of PCDD/PCDF patterns of congeners and isomers for the sewage sludge and river sediment samples with those of stack gas emissions of waste incinerators and of pentachlorophenol allows the conclusion that the main source of PCDDs and PCDFs found in these samples is pentachlorophenol. Results of the Lake Constance sediment core indicate that here the atmospheric immission from waste incineration might be predominant.  相似文献   


14.
Aliphatic liquid as a basic fuel was incinerated in a laboratory scale pilot plant. Inorganic chlorine and organic chlorine mixed with basic fuel were used as additive chemicals. Sodium chloride (NaCl) and tetrachloroethylene (C2Cl4) were used as the sources of inorganic and organic chlorine. Combustion parameters were adjusted for optimum combustion and, consequently, the amount of particles in flue gases was low. The concentrations of chlorine in flue gases were high enough for possible formation reactions of organic chlorinated compounds in all of the chlorine input tests. An increase in chlorine input did not significantly increase the amounts of highly chlorinated organic compounds, like PCDD/Fs. The main result was that chlorophenol concentrations increased in parallel with organic chlorine input. Comparing organic chlorine to inorganic chlorine tests showed that more highly substituted PCDD/F congeners were formed when organic chlorine was the additive chlorine source. The formation of highly chlorinated organic compounds such as PCDD/Fs requires not only chlorine and aliphatic fuel to be formed, but some catalysts are also needed.  相似文献   

15.
Kim SC  Jeon SH  Jung IR  Kim KH  Kwon MH  Kim JH  Yi JH  Kim SJ  You JC  Jung DH 《Chemosphere》2001,43(4-7):701-707
This study was carried out to examine the formation and the emission status of polychlorinated dibenzo-p-dioxins/polychlorinated dibenzofurans (PCDDs/PCDFs) in the flue gases of commercial-scale municipal solid waste (MSW) incinerators, and thus to provide the engineering data for the reduction of PCDDs/PCDFs emitted from MSW incinerators. The formation concentrations of the PCDDs/PCDFs generated at the outlet of waste heat boilers (WHB) were in the range of 1.18-29.61 ng-TEQ/N m3 (average 5.75 ng-TEQ/N m3), while the emission concentrations at the stacks were in the range of 0.026-4.548 ng-TEQ/N m3 (average 0.924 ng-TEQ/N m3). Two major 2,3,7,8-substituted congeners were 2,3,4,7,8-PeCDF and 2,3,4,6,7,8-HxCDF, and their concentrations were up to 50% and 64% of total TEQ values at the outlet of WHB and the stack, respectively. From the results of multi-regression analysis, the formation concentration of PCDDs/PCDFs could be predicted as follows with the correlation factor of r2 = 0.962: PCDDs/PCDFs (ng-TEQ/N m3) = 3.036 (Cl) + 0.094 (T1) - 0.472 (Combustibles) + 0.059 (CO) - 0.039 (THC) - 3.366 (H) + 22.157, where T1 (degrees C) is the temperature at the outlet of the WHB. Cl, Combustibles and H are given as percentages and the others are in parts per million.  相似文献   

16.
Newspapers impregnated with NaCl mixed with various chloride metals (CuCl2, MgCl2, MnCl2, FeCl3, NiCl2, and CoCl2) and electric wire coated with polyvinyl chloride (PVC) were combusted in a well-controlled incinerator. Exhaust gas samples collected at the outlet of the incinerator were analyzed for dioxins (PCDDs, PCDFs, and coplanar PCBs) by gas chromatography/mass spectrometry. The amount of total dioxins formed from newspaper samples ranged from 34.2 ng/g (with NaCl+CoCl2) to 67.0 ng/g (with NaCl+CuCl2). PCDFs composed 88-94% of the total dioxins formed in the exhaust gases. The highest levels of PCDF isomers obtained were Cl3-CDF from the sample with NaCl+CuCl2 (14.8 ng/g), Cl2-CDF from the sample with NaCl+MgCl2 (12.3 ng/g), and Cl(1)-CDF from samples with NaCl+MnCl2 (12.6 ng/g), with NaCl+FeCl3 (11.8 ng/g), and with NaCl+NiCl2 (13.3 ng/g), and with NaCl+CoCl2 (8.62 ng/g). The total of Cl4-8-CDDs comprised 76-88% of the total Cl1-8-CDDs. In particular, Cl7-CDDs had the highest levels except for the sample with NaCl+NiCl2. Total dioxins formed from samples of electric wire coated with PVC and PVC alone were 38.3 ng/g and 112 ng/g, respectively, suggesting that the presence of copper reduced dioxin formation.  相似文献   

17.
Laboratory bleaching experiments were performed to investigate PCDD/PCDF formation mechanisms. The results indicated that there were two (or more) mechanisms; direct chlorination of DBD/DBF and formation from precursors which are not extractable. In general, PCDDs/PCDFs are formed in the C stage but some minor isomers were found to be formed in the E stage.  相似文献   

18.
Two artificial wastes (A and B) whose contents reflect regional differences in municipal solid waste composition, were used to investigate the thermal formation of polychlorinated dibenzo-p-dioxins (PCDDs), dibenzofurans (PCDFs), biphenyls (PCBs), and naphthalenes (PCNs) during incineration. Flue gas samples were simultaneously collected at three ports in the post-combustion zone corresponding to flue gas temperatures of 400, 300, and 200 °C. The combustion of Waste B, which had a higher chlorine and metal content than Waste A, produced greater levels of highly-chlorinated homologues, as demonstrated by a higher degree of chlorination. The total concentrations of PCDDs, PCDFs, PCBs, and PCNs formed in the combustion of both wastes increased as temperature decreased along the convector. There were no significant differences in total concentrations between Waste A and Waste B combustion at specific temperatures, with exception of PCDFs at 400 °C. Orthogonal Projections to Latent Structures Discriminant Analysis (OPLS-DA) modeling, used to evaluate the data for all compound groups, suggest that during flue gas quenching at temperatures of 400 °C low-chlorinated homologues are preferentially formed in the presence of copper, which is known to be a very active catalyst for this process. At 300 and 200 °C, the formation of highly-chlorinated homologues is favored.  相似文献   

19.
This study shows the catalyzing effects of iron and copper on the formation of chlorinated compounds such as chlorobenzenes (ClBzs), chlorophenols (CIPhs), polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs). Both total concentrations and congener distributions have been studied. The parameters and conditions varied during the combustion tests were the complete and incomplete combustion and the metal and chlorine addition. The incomplete combustion promoted the formation of organic chlorinated compounds in flue gas particles. Highly chlorinated congeners of PCDD/F were dominant in the flue gas particles, whereas the importance of lower chlorinated congener were increased in the gas phase. In the complete combustion conditions the concentrations of PCDD/Fs increased when the degree of chlorination were high, nevertheless the concentrations of tetra and penta PCDD/Fs were higher in the gas phase than the concentrations in the fly ash particles. Organic chlorine promoted the formation of chlorinated compounds more effectively than inorganic chlorine, which instead promoted the formation of PCDD/Fs in the gas phase, especially with copper catalyst. Different concentration levels of chlorinated compounds were observed in the gas phase and in particles when the chlorine source and combustion conditions were varied from incomplete to optimum conditions. Both copper and iron seem to have a catalytic effect on PCDD/F formation.  相似文献   

20.
The formation rates of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) from polycyclic aromatic hydrocarbons (PAHs), activated carbon, and phenol were compared. The heat treatment at 300°C of all tested PAH on silica in the presence of CUCl2 Preferred PCDDs over PCDDs. Perylene reproducibly gave a higher yield of PCDDs than activated carbon gave under the same conditions. The formation rate of PCDDs from perylene could be higher than the values in this study because the residence time of perylene in the reactor is shorter than that of activated carbon. PCDDs were mainly formed from phenol.  相似文献   