1.
The CO2SINK pilot project at Ketzin is aimed at a better understanding of geological CO2 storage operation in a saline aquifer. The reservoir consists of fluvial deposits with average permeability ranging between 50 and 100 mDarcy. The main focus of CO2SINK is developing and testing of monitoring and verification technologies. All wells, one for injection and two for observation, are equipped with smart casings (sensors behind casing, facing the rocks) containing a Distributed Temperature Sensing (DTS) and electrodes for Electrical Resistivity Tomography (ERT). The in-hole Gas Membrane Sensors (GMS) observed the arrival of tracers and CO2 with high temporal resolution. Geophysical monitoring includes Moving Source Profiling (MSP), Vertical Seismic Profiling (VSP), crosshole, star and 4-D seismic experiments. Numerical models are benchmarked via the monitoring results indicating a sufficient match between observation and prediction, at least for the arrival of CO2 at the first observation well. Downhole samples of brine showed changes in the fluid composition and biocenosis. First monitoring results indicate anisotropic flow of CO2 coinciding with the “on-time” arrival of CO2 at observation well one (Ktzi 200) and the later arrival at observation well two (Ktzi 202). A risk assessment was performed prior to the start of injection. After one year of operations about 18,000 t of CO2 were injected safely.  相似文献   

2.
The onshore CO2-storage site Ketzin consists of one CO2-injection well and two observation wells. Hydraulic tests revealed permeabilities between 50 and 100 mD for the sandstone rock units. The designated injection well Ktzi 201 showed similar production permeability. After installation of the CO2-injection string, an injection test with water yielded a significantly lower injectivity of 0.002 m3/d kPa, while the observation wells showed an injection permeability in the same range as the productivity. Several possible reasons for the severe decline in injectivity are discussed. Acidification of the reservoir interval, injection at high wellhead pressure, controlled mini-fractures and back-production of the well are discussed to remove the plugging material to re-establish the required injectivity of the well. It has been decided to perform a nitrogen lift and analyse the back-produced fluids. Initially during the lift, the back-produced fluids were dark-black. Chemical and XRD analyses proved that the black solids consisted mainly of iron sulphide. Sulphate-reducing bacteria (SRB) were detected in fluid samples with up to 106 cells/ml by fluorescent in situ hybridisation (FISH) indicating that the formation of iron sulphide was caused by bacterial activity. Organic compounds within the drilling mud and other technical fluids were likely left during the well completion process, thus providing the energy source for strong proliferation of bacteria. During the lift, the fraction of SRB in the whole bacterial community decreased from approximately 32% in downhole samples to less than 5%. The lift of Ktzi 201 succeeded in the full restoration of the well productivity and injectivity. Additionally, the likely energy source of the SRB was largely removed by the lifting, thus ensuring the long-term preservation of the injectivity.  相似文献   

3.
Numerical modelling of multiphase flow is an essential tool to ensure the viability of long-term and safe CO2 storage in geological formations. Uncertainties arising from the heterogeneity of the formation and lack of knowledge of formation properties need to be assessed in order to create a model that can reproduce the data available from monitoring. In this study, we investigated the impact of unknown spatial variability in the petrophysical properties within a sandy channel facies of a fluviatile storage formation using stochastic methods in a Monte Carlo approach. The stochastic method has been applied to the Ketzin test site (CO2SINK), and demonstrates that the deterministic homogeneous model satisfactorily predicts the first CO2 arrival time at the Ketzin site. The equivalent permeability was adjusted to the injection pressure and is in good agreement with the hydraulic test. It has been shown that with increasing small-scale heterogeneity, the sharpness of the CO2 front decreases and a greater volume of the reservoir is affected, which is also seen in an increased amount of dissolved CO2. Increased anisotropy creates fingering effects, which result in higher probabilities for earlier arrival times. Generally, injectivity decreases with increasing heterogeneity.  相似文献   

4.
The paper presents an approach for the interpretation of hydraulic tests of a CO2 storage reservoir. The sandstone reservoir is characterised by a fluviatile channel structure embedded in a low-permeability matrix. Pumping tests were carried out in three wells, with simultaneous pressure monitoring in each well.The hydraulic parameters (permeability and storativity) and the boundary configurations were calibrated using three different approaches: (i) parameter calibration and type curve interpretation for single-hole tests, (ii) calibration of the entire build-up phase for cross-hole tests, and (iii) calibration of the initial pressure response for cross-hole pumping tests. In addition, the arrival time of the pressure response was determined and provides additional information about the pathways of hydraulic connection.The measured pumping test permeabilities of the formation were much lower than those measured on the cores, which is very unusual. The pumping test permeabilities are mainly between 50 mD and 100 mD (millidarcy), while core samples show a mean aquifer permeability of 500–1100 mD. Based on this it was concluded that some kind of continuous low-permeability structure exists, which was supported by core material. Three possible aquifer configurations were considered. The first and second were derived from traditional pumping test analysis and were conceptualised using flow boundaries. Each of the analyses provides a different result. A method was developed in which these differences were resolved by interpreting the pressure response with respect to its spatial and temporal sensitivity. This solution lead to a third configuration which was mainly based on spatially-variable permeabilities. Taking into account the pumping test results, the geological background and the behaviour of injected CO2, we consider only the third configuration to be realistic. The results are in good agreement with modelled CO2 arrival times and pressure history.  相似文献   

5.
Deep saline aquifers have large capacity for geological CO2 storage, but are generally not as well characterized as petroleum reservoirs. We here aim at quantifying effects of uncertain hydraulic parameters and uncertain stratigraphy on CO2 injectivity and migration, and provide a first feasibility study of pilot-scale CO2 injection into a multilayered saline aquifer system in southwest Scania, Sweden. Four main scenarios are developed, corresponding to different possible interpretations of available site data. Simulation results show that, on the one hand, stratigraphic uncertainty (presence/absence of a thin mudstone/claystone layer above the target storage formation) leads to large differences in predicted CO2 storage in the target formation at the end of the test (ranging between 11% and 98% of injected CO2 remaining), whereas other parameter uncertainty (in formation and cap rock permeabilities) has small impact. On the other hand, the latter has large impact on predicted injectivity, on which stratigraphic uncertainty has small impact. Salt precipitation at the border of the target storage formation affects CO2 injectivity for all considered scenarios and injection rates. At low injection rates, salt is deposited also within the formation, considerably reducing its availability for CO2 storage.  相似文献   

6.
Climate change is being caused by greenhouse gases such as carbon dioxide (CO2). Carbon capture and storage (CCS) is of interest to the scientific community as one way of achieving significant global reductions of atmospheric CO2 emissions in the medium term. CO2 would be captured from large stationary sources such as power plants and transported via pipelines under high pressure conditions to underground storage. If a downward leakage from a surface transportation system module occurs, the CO2 would undergo a large temperature reduction and form a bank of “dry ice” on the ground surface; the sublimation of the gas from this bank represents an area source term for subsequent atmospheric dispersion, with an emission rate dependent on the energy balance at the bank surface. Gaseous CO2 is denser than air and tends to remain close to the surface; it is an asphyxiant, a cerebral vasodilator and at high concentrations causes rapid circulatory insufficiency leading to coma and death. Hence a subliming bank of dry ice represents safety hazard. A model is presented for evaluating the energy balance and sublimation rate at the surface of a solid frozen CO2 bank under different environmental conditions. The results suggest that subliming gas behaves as a proper dense gas (i.e. it remains close to the ground surface) only for low ambient wind speeds.  相似文献   

7.
The injection of CO2 at the Ketzin storage site and the chemical detection of its arrival in the observation well allowed testing of different numerical simulation codes. ECLIPSE 100 (E100, black-oil simulator), ECLIPSE 300 (E300, compositional CO2STORE) and MUFTE-UG were used for predictive modelling applying a constant injection rate of 1 kg s?1 CO2 and for a history match applying the actual variable injection rate which ranged from 0 to 0.7 kg s?1 and averaged 0.23 kg s?1. The geological model applied, is based on all available geophysical and geological information and has been the same for all programs.The results of the constant injection regime show a good agreement among the programs with a discrepancy of 21–33% for the CO2 arrival times. However, it is determined from the comparison of the cumulative mass of CO2 at the time of CO2 arrival that the injection regime is an important factor for the accurate prediction of CO2 migration within a saline aquifer. Comparing the actual variable injection regime with the simulations applying a constant injection rate the results are relatively inaccurate.Regarding the actual variable injection regime, which was evaluated using all three simulators, the computational results show a good agreement with the data actually measured at the first observation well. Here, the calculated arrival times exceeded the actual ones by 8.1% (E100), 9.2% (E300) and 17.7% (MUFTE-UG).It can be concluded that irrespective of the deviations of the simulations, due to combinations of different codes and slight differences in input parameters, all three programs are well equipped to give a reliable estimate of the arrival of CO2. Deviations in the results mainly occur due to different input data and grid size choices done by the different modelling teams working independently of each other. Deviations of the simulations results compared to the actual CO2 arrival time result from uncertainties in the implementation of the geological model, which was set up based on well log data and analogue studies.  相似文献   

8.
9.
Typical top-down regional assessments of CO2 storage feasibility are sufficient for determining the maximum volumetric capacity of deep saline aquifers. However, they do not reflect the regional economic feasibility of storage. This is controlled, in part, by the number and type of injection wells that are necessary to achieve regional CO2 storage goals. In contrast, the geomechanics-based assessment workflow that we present in this paper follows a bottom-up approach for evaluating regional deep saline aquifer CO2 storage feasibility. The CO2 storage capacity of an aquifer is a function of its porous volume as well as its CO2 injectivity. For a saline aquifer to be considered feasible in this assessment it must be able to store a specified amount of CO2 at a reasonable cost per ton of CO2. The proposed assessment workflow has seven steps that include (1) defining the storage project and goals, (2) characterizing the geology and developing a geomechanical model of the aquifer, (3) constructing 3D aquifer models, (4) simulating CO2 injection, (5,6) evaluating CO2 injection and storage feasibility (with and without injection well stimulation), and (7) determining whether it is economically feasible to proceed with the storage project. The workflow was applied to a case study of the Rose Run sandstone aquifer in the Eastern Ohio River Valley, USA. We found that it is feasible in this region to inject 113 Mt CO2/year for 30 years at an associated well cost of less than US $1.31/t CO2, but only if injectivity enhancement techniques such as hydraulic fracturing and injection induced micro-seismicity are implemented.  相似文献   

10.
The paper presents a methodology for CO2 chain analysis with particular focus on the impact of technology development on the total system economy. The methodology includes the whole CO2 chain; CO2 source, CO2 capture, transport and storage in aquifers or in oil reservoirs for enhanced oil recovery. It aims at supporting the identification of feasible solutions and assisting the selection of the most cost-effective options for carbon capture and storage. To demonstrate the applicability of the methodology a case study has been carried out to illustrate the possible impact of technology improvements and market development. The case study confirms that the CO2-quota price to a large extent influence the project economy and dominates over potential technology improvements. To be economic feasible, the studied chains injecting the CO2 in oil reservoirs for increased oil production require a CO2-quota price in the range of 20–27 €/tonne CO2, depending on the technology breakthrough. For the chains based on CO2 storage in saline aquifers, the corresponding CO2-quota price varies up to about 40 €/tonne CO2.  相似文献   

11.
This study reveals the first analyses of the composition and activity of the microbial community of a saline CO2 storage aquifer. Microbial monitoring during CO2 injection has been reported. By using fluorescence in situ hybridisation (FISH), we have shown that the microbial community was strongly influenced by the CO2 injection. Before CO2 arrival, up to 6 × 106 cells ml−1 were detected by DAPI staining at a depth of 647 m below the surface. The microbial community was dominated by the domain Bacteria that represented approximately 60% to 90% of the total cell number, with Proteobacteria and Firmicutes as the most abundant phyla comprising up to 47% and 45% of the entire population, respectively. Both the total cell counts as well as the counts of the specific physiological groups revealed quantitative and qualitative changes after CO2 arrival. Our study revealed temporal outcompetition of sulphate-reducing bacteria by methanogenic archaea. In addition, an enhanced activity of the microbial population after five months CO2 storage indicated that the bacterial community was able to adapt to the extreme conditions of the deep biosphere and to the extreme changes of these atypical conditions.  相似文献   

12.
Carbon dioxide sequestration in deep saline aquifers is a means of reducing anthropogenic atmospheric emissions of CO2. Among various mechanisms, CO2 can be trapped in saline aquifers by dissolution in the formation water. Vaporization of water occurs along with the dissolution of CO2. Vaporization can cause salt precipitation, which reduces porosity and impairs permeability of the reservoir in the vicinity of the wellbore, and can lead to reduction in injectivity. The amount of salt precipitation and the region in which it occurs may be important in CO2 storage operations if salt precipitation significantly reduces injectivity. Here we develop an analytical model, as a simple and efficient tool to predict the amount of salt precipitation over time and space. This model is particularly useful at high injection velocities, when viscous forces dominate.First, we develop a model which treats the vaporization of water and dissolution of CO2 in radial geometry. Next, the model is used to predict salt precipitation. The combined model is then extended to evaluate the effect of salt precipitation on permeability in terms of a time-dependent skin factor. Finally, the analytical model is corroborated by application to a specific problem with an available numerical solution, where a close agreement between the solutions is observed. We use the results to examine the effect of assumptions and approximations made in the development of the analytical solution. For cases studied, salt saturation was a few percent. The loss in injectivity depends on the degree of reduction of formation permeability with increased salt saturation. For permeability-reduction models considered in this work, the loss in injectivity was not severe. However, one limitation of the model is that it neglects capillary and gravity forces, and these forces might increase salt precipitation at the bottom of formation particularly when injection rate is low.  相似文献   

13.
Enhanced oil recovery (EOR) through CO2 flooding has been practiced on a commercial basis for the last 35 years and continues today at several sites, currently injecting in total over 30 million tons of CO2 annually. This practice is currently exclusively for economic gain, but can potentially contribute to the reduction of emissions of greenhouse gases provided it is implemented on a large scale. Optimal operations in distributing CO2 to CO2-EOR or enhanced gas recovery (EGR) projects (referred to here collectively as CO2-EHR) on a large scale and long time span imply that intermediate storage of CO2 in geological formations may be a key component. Intermediate storage is defined as the storage of CO2 in geological media for a limited time span such that the CO2 can be sufficiently reproduced for later use in CO2-EHR. This paper investigates the technical aspects, key individual parameters and possibilities of intermediate storage of CO2 in geological formations aiming at large scale implementation of carbon dioxide capture and storage (CCS) for deep emission reduction. The main parameters are thus the depth of injection and density, CO2 flow and transport processes, storage mechanisms, reservoir heterogeneity, the presence of impurities, the type of the reservoirs and the duration of intermediate storage. Structural traps with no flow of formation water combined with proper injection planning such as gas-phase injection favour intermediate storage in deep saline aquifers. In depleted oil and gas fields, high permeability, homogeneous reservoirs with structural traps (e.g. anticlinal structures) are good candidates for intermediate CO2 storage. Intuitively, depleted natural gas reservoirs can be potential candidates for intermediate storage of carbon dioxide due to similarity in storage characteristics.  相似文献   

14.
A numerical study was conducted to predict pCO2 change in the ocean on a continental shelf by the leakage of CO2, which is originally stored in the aquifer under the seabed, in the case that a large fault connects the CO2 reservoir and the seabed by an earthquake or other diastrophism. The leakage rate was set to be 6.025 × 10−4 kg/m2/sec from 2 m × 100 m fault band, which corresponds to 3800 t-CO2/year, referring to the monitored seepage rate from an existing EOR field. The target space in this study was limited to the ocean above the seabed, the depth of which was 200 or 500 m. The computational domain was idealistically rectangular with the seabed fault-band perpendicular to the uniform flow. The CO2 takes a form of bubbles or droplets, depending on the depth of water, and their behaviour and dissolution were numerically simulated during their rise in seawater flow. The advection–diffusion of dissolved CO2 was also simulated. As a result, it was suggested that the leaked CO2 droplets/bubbles all dissolve in the seawater before spouting up to the atmosphere, and that the increase in pCO2 in the seawater was smaller than 500 μ atm.  相似文献   

15.
Saline aquifers of high permeability bounded by overlying/underlying seals may be surrounded laterally by low-permeability zones, possibly caused by natural heterogeneity and/or faulting. Carbon dioxide (CO2) injection into and storage in such “closed” systems with impervious seals, or “semi-closed” systems with non-ideal (low permeability) seals, is different from that in “open” systems, from which the displaced brine can easily escape laterally. In closed or semi-closed systems, the pressure buildup caused by continuous industrial-scale CO2 injection may have a limiting effect on CO2 storage capacity, because geomechanical damage caused by overpressure needs to be avoided. In this research, a simple analytical method was developed for the quick assessment of the CO2 storage capacity in such closed and semi-closed systems. This quick-assessment method is based on the fact that native brine (of an equivalent volume) displaced by the cumulative injected CO2 occupies additional pore volume within the storage formation and the seals, provided by pore and brine compressibility in response to pressure buildup. With non-ideal seals, brine may also leak through the seals into overlying/underlying formations. The quick-assessment method calculates these brine displacement contributions in response to an estimated average pressure buildup in the storage reservoir. The CO2 storage capacity and the transient domain-averaged pressure buildup estimated through the quick-assessment method were compared with the “true” values obtained using detailed numerical simulations of CO2 and brine transport in a two-dimensional radial system. The good agreement indicates that the proposed method can produce reasonable approximations for storage–formation–seal systems of various geometric and hydrogeological properties.  相似文献   

16.
Sequestration of carbon dioxide (CO2) in deep saline aquifers has emerged as an option for reducing greenhouse gas emissions to the atmosphere. The large amounts of supercritical CO2 that need to be injected into deep saline aquifers may cause large fluid pressure increases. The resulting overpressure may promote reactivation of sealed fractures or the creation of new ones in the caprock seal. This could lead to escape routes for CO2. In order to assess the probability of such an event, we model an axisymmetric horizontal aquifer–caprock system, including hydromechanical coupling. We study the failure mechanisms, using a viscoplastic approach. Simulations illustrate that, depending on boundary conditions, the least favorable moment takes place at the beginning of injection. Initially, fluid pressure rises sharply because of a reduction in permeability due to desaturation. Once CO2 fills the pores in the vicinity of the injection well and a capillary fringe is fully developed, the less viscous CO2 displaces the brine and the capillary fringe laterally. The overpressure caused by the permeability reduction within the capillary fringe due to desaturation decreases with distance from the injection well. This results in a drop in fluid pressure buildup with time, which leads to a safer situation. Nevertheless, in the presence of low-permeability boundaries, fluid pressure continues to rise in the whole aquifer. This occurs when the radius of influence of the injection reaches the outer boundary. Thus, caprock integrity might be compromised in the long term.  相似文献   

17.
As monitoring is essential for the proper management of geological storage of carbon dioxide (CO2), the ability to value information from monitoring is indispensable to adequately design a monitoring program. It is necessary to judge whether the expected improvement in management is worth the cost of monitoring. The value of information (VOI) is closely related to the possible increase in expected utility gained by gathering the information, the concept of which can be applied to such judgement. Although VOI analysis has been extensively studied in the context of decision analysis, its application to the management of carbon dioxide capture and storage (CCS) operations is rare. This paper introduces and discusses the methodology of VOI analyses in the context of monitoring CO2 storage. A motivating problem with discrete probabilities is used to illustrate the concept of VOI. It is demonstrated that information is not always of value; for information to be worthwhile, monitoring under uncertainty must satisfy certain conditions. This concept is then extended to continuous probability distributions. The effects of prior uncertainty and information reliability on the VOI are examined. It is shown that an excessive improvement in information accuracy yields little value and that the optimal level of reliability can be inferred. VOI analyses provide quantitative insights into the value of information-gathering activities and therefore can be an objective means to adequately design and impartially justify a monitoring program.  相似文献   

18.
Alberta is the province with the largest CO2 emissions in Canada, with approximately two-thirds of emissions originating from large stationary sources. Due to the fortuitous association of large CO2 sources with the storage capacity offered by the underlying Alberta basin, it is expected that large-scale CO2 geological storage in Canada will occur in Alberta first, and both levels of governments are contemplating measures to facilitate implementation. A review of the current provincial and federal legislation and regulations presented in this paper indicates that the existing legal and regulatory regime is reasonably sufficient, with some modifications, to accommodate the active injection phase of CO2 capture and storage (CCS) operations, and the early takers of this new technology. However, governments in Alberta and Canada, and likely everywhere, need to address several pressing issues dealing mainly with the CCS post-operational phase. These issues, reviewed in this paper from an Alberta and Canadian perspective, fall into several categories: jurisdictional, property (ownership), regulatory and liability. Because Alberta is a landlocked province, matters relating to CO2 storage under the seabed will not be addressed here except when discussing matters of jurisdiction and CO2 classification. Possible models for post-injection liability transfer to the state are also presented. Although this review is focused on western Canada conditions, the issues are broad enough to be of interest in other jurisdictions, which may also adopt parts of the legal and regulatory framework that is quite well developed in Alberta.  相似文献   

19.
CO2 capture and geological storage (CCS) is considered as a viable option to mitigate greenhouse gas emissions during the transition phase towards the use of clean and renewable energy. This paper concentrates on the transport of CO2 between source (CO2 capture at plants) and sink (geological storage reservoirs). In the cost estimation of CO2 transport, the pipeline diameter plays an important role. In this respect, the paper reviews equations that were used in several reports on CO2 pipeline transport. As some parameters are not taken into account in these equations, alternative formulas are proposed which calculate the proper inner diameter size based on flow rate, pressure drop per unit length, CO2 density, CO2 viscosity, pipeline material roughness and topographic height differences (the Darcy–Weisbach solution) and, in addition, on the amount and type of bends (the Manning solution). Comparison between calculated diameters using the reviewed and the proposed equations demonstrate the important influence of elevation difference (which is not considered in the reviewed equations) and pipeline material roughness-related factor on the calculated diameter. Concerning the latter, it is suggested that a Darcy–Weisbach roughness height of 0.045 mm better corresponds to a Manning factor of 0.009 than higher Manning values previously proposed in literature. Comparison with the actual diameter of the Weyburn pipeline confirms the accuracy of the proposed equations. Comparison with other existing CO2 pipelines (without pressure information) indicate that the pipelines are designed for lower pressure gradients than 25 Pa/m or for (future) higher flow rates. The proposed Manning equation is implemented in an economic least-cost route planner in order to obtain the best economic solution for pipeline trajectory and corresponding diameter.  相似文献   

20.
Ultrasonic experiments were undertaken on CO2 flooded sandstone core samples, both synthetic sandstones and core plugs from the CRC1 CO2 injection well in the Otway Basin, Victoria, South Eastern. Australia. The aim of these laboratory tests was to investigate the effects of CO2 as a pore fluid on the seismo-acoustic response of the sandstone and ultimately to provide an indication of the sensitivity of time-lapse seismic imaging of the eventual CO2/CH4 plume in the Otway, Waarre C formation.The synthetic sandstones were manufactured using both a proprietary calcium in situ precipitation (CIPS) process and a silica cementing technique. Samples were tested in a computer controlled triaxial pressure cell where pore pressures can be controlled independently of the confining pressures. The pressure cell is equipped with ultrasonic transducers housed in the loading platens. Consequently, effective pressures equivalent to those expected in the reservoir can be applied while ultrasonic testing is undertaken. Both compressional, P and shear waves, S were recorded via a digital oscilloscope at a range of effective pressure steps. Pore pressures were varied from 4 MPa to 17 MPa to represent both the gaseous and liquid phase regions of the CO2 phase diagram. Similar experiments were conducted on core plugs from the Waarre C reservoir horizon obtained from the CRC1 injection well, but with an intervening brine-saturated step and in some cases with a CO2/CH4 mix of 80%/20% molar fraction which is representative of the field situation. However, the pore pressure in these experiments was held at 4 MPa. Finally, acoustic impedances and reflection coefficients were calculated for the reservoir using Gassmann theory and the implications for imaging the CO2 plume is discussed.  相似文献   