首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The purpose of this study was to gather air quality data for four pollutants inside and outside of three pairs of structures for different seasons of the year. This paper presents results obtained during the summer, fall, and winter seasons of 1969–70. Suspended particulate, soiling particulate, carbon monoxide, and sulfur dioxide were measured at pairs of public buildings, office buildings, and private homes. A brief preliminary program was conducted during the winter of 1969 to verify our procedures and equipment and to assess the effects of heating and cooking systems in private homes on indoor levels of air pollutants. Two self-contained and portable instrument packages were constructed for the measurement program. The major components of each trailer package were a central vacuum pump for drawing air samples through particulate collection niters, four paper-tape soiling samplers, a conductimetric analyzer for sulfur dioxide, an infrared analyzer for carbon monoxide, a master control unit, and supporting apparatus to make the trailer self-contained. Each pair of buildings was sampled simultaneously for a two-week period. Four sampling points were selected at each structure, two outside and two inside. Suspended particulate samples were collected for 12-hr day and night periods, soiling particulate samples for 2-hr periods, and gaseous samples for 5-min periods. The results show the ease of penetration of particulate into private homes and the removal ability of air conditioning systems. Outdoor daily activity greatly influences particulate levels and urban carbon monoxide levels. Internal generation of pollutants was a significant factor in measured interior concentrations in some of the structures sampled.  相似文献   

2.
In the summer of 1998, the air quality (indicators: CO, NO, NO2, O3) above the water surface of the Lake Balderey (Essen, Ruhr area, North Rhine-Westphalia, Germany), an artificial lake used for recreation purposes, was measured using the Fourier transform infrared spectroscopy (FTIR) and differential optical absorption spectroscopy (DOAS) remote measurement methods. The lake, with an area of 3 km2 was created by damming the Ruhr and is surrounded by higher ground. In calm, bright weather conditions, this location results in a low-exchange situation (formation of temperature inversions, cold air dynamics) with a sustained impact on pollutant concentrations over the lake. The results of trace substance measurements (1/2 h mean values) were compared with values from comparison stations (suburban, high traffic and forest) located outside the area of the lake. In general, it was found that mean CO and NO concentrations over the lake were very low (0.3 ppm and 7.5 ppb, respectively). NO2 values (15 ppb) were some 3.5 times higher than those recorded at the forest station and O3 values, at 27 ppb, almost reached the same level as at the forest station (30 ppb). Mass flow densities as a function of wind direction, diurnal courses, differences between weekdays and weekends and comparisons with air quality standards are presented for the lake station.  相似文献   

3.
Abstract

Ametpreviously described by Mann et al.1 for the determination of hexachlorobenzene in air was modified to detect DBCP in air at the level of 0.02 ppb (by volume). The method utilizes Chromosorb 101 as a trapping medium with subsequent analysis of the eluted DBCP by electron capture ‐ gas chromatography. The procedure was tested using air flows of 1 1/min to 5 1/min for sampling periods of 30 min to 3 hr. Recoveries of greater than 90% were obtained for DBCP levels ranging from 0.07 ppb to 20 ppm. More than 90% of the DBCP stored on Chromosorb 101 at ambient temperature for one month was recovered. A one‐half acre field plot was sprayed with DBCP using the drench method. Air samples were taken from the breathing zone of the applicator during the mixingspraying and clean‐up procedures. Air samples were also taken periodically around the perimeter of the plot for up to 7 days after spraying.  相似文献   

4.
As part of the exposure assessment scheme for a community-based air pollution health effects study, 43 homes of study participants, located in two Houston neighborhoods, were monitored for weekly-average indoor formaldehyde levels by means of diffusion samplers. Consecutive 12-hour aldehyde sampling for one-week periods was conducted in 12 of the homes by means of pumps and impingers. In six houses where simultaneous monitoring with both methods occurred, good correlation between the results from the diffusion samplers and the standard impinger method was observed. Diffusion sampler precision was variable and lower than expected, and a small positive measurement bias could be inferred. The distribution of house-average indoor formaldehyde concentrations from diffusion monitoring was similar to that obtained during a previous housing survey in Houston, with concentrations in 19 percent of the homes exceeding 0.10 ppm. Formaldehyde levels in this group of conventional, mostly older homes could not be associated with smoking, cooking, home age or structure type. However, there was a statistically significant difference between mean indoor concentrations in the two neighborhoods.  相似文献   

5.
Aldicarb, Temik 15 G, was incorporated in furrows at 3.37 and 6.73 kg ai (active ingredient)/ha and carrots (Daucus carota L.) were directly seeded on the same day. The numbers of nematode larvae were significantly suppressed in the treated plots; averages were 249, 74, and 51/50 cc soil samples for control (0), 3.37 and 6.73 kg ai/ha, respectively. Aldicarb treatment resulted in a 28% yield increase as compared to the untreated. Aldicarb residue in carrots was 28 ppb for the low treatment and 46 ppb for the high. Residual levels in soil of high treatment declined from 61 to 31 ppb during two weeks prior to harvest, meanwhile, those in the low decreased slightly from 13 to 12 ppb. Carrots placed in hydroponic solution containing aldicarb 14.5 ppm for 6 days, had an aldicarb residue of 10.26 ppb and the hydroponic solution, 2.7 ppb. Persistence of aldicarb residue was in carrot greater than in soil greater than in hydroponic solution.  相似文献   

6.
Abstract

Aldicarb, Temik® 15 G, was incorporated in furrows at 3.37 and 6.73 kg ai (active ingredent)/ha and carrots (Caucus carota L.) were directly seeded on the same day. The numbers of nematode larvae were significantly suppressed in the treated plots; averages were 249, 74, and 51/ 50 cc soil samples for control (0), 3.37 and 6.73 kg ai/ha, respectively. Aldicarb treatment resulted in a 28% yield increase as compared to the untreated. Aldicarb residue in carrots was 28 ppb for the low treatment and 46 ppb for the high. Residual levels in soil of high treatment declined from 6l to 31 ppb during two weeks prior to harvest, meanwhile, those in the low decreased slightly from 13 to 12 ppb. Carrots placed in hydroponic solution containing aldicarb 14.5 ppm for 6 days, had an aldicarb residue of 10.26 ppb and the hydroponic solution, 2.7 ppb. Persistence of aldicarb residue was in carrot > in soil > in hydroponic solution.  相似文献   

7.
A dynamic multi-compartment computer model has been developed to describe the physical processes determining indoor pollutant concentrations as a function of outdoor concentrations, indoor emission rates and building characteristics. The model has been parameterised for typical UK homes and workplaces and linked to a time-activity model to calculate exposures for a representative homemaker, schoolchild and office worker, with respect to NO2. The estimates of population exposures, for selected urban and rural sites, are expressed in terms of annual means and frequency of hours in which air quality standards are exceeded. The annual mean exposures are estimated to fall within the range of 5–21 ppb for homes with no source, and 21–27 ppb for homes with gas cooking, varying across sites and population groups. The contribution of outdoor exposure to annual mean NO2 exposure varied from 5 to 24%, that of indoor penetration of outdoor air from 17 to 86% and that of gas cooking from 0 to 78%. The frequency of exposure to 1 h mean concentrations above 150 ppb was very low, except for people cooking with gas.  相似文献   

8.
Use of vent-free gas heating appliances for supplemental heating in U.S. homes is increasing. However, there is currently a lack of information on the potential impact of these appliances on indoor air quality for homes constructed according to energy-efficient and green building standards. A probabilistic analysis was conducted to estimate the impact of vent-free gas heating appliances on indoor air concentrations of carbon monoxide (CO), nitrogen dioxide (NO2), carbon dioxide (CO2), water vapor, and oxygen in “tight” energy-efficient homes in the United States. A total of 20,000 simulations were conducted for each Department of Energy (DOE) heating region to capture a wide range of home sizes, appliance features, and conditions, by varying a number of parameters, e.g., room volume, house volume, outdoor humidity, air exchange rates, appliance input rates (Btu/hr), and house heat loss factors. Predicted airborne levels of CO were below the U.S. Environmental Protection Agency (EPA) standard of 9 ppm for all modeled cases. The airborne concentrations of NO2 were below the U.S. Consumer Product Safety Commission (CPSC) guideline of 0.3 ppm and the Health Canada benchmark of 0.25 ppm in all cases and were below the World Health Organization (WHO) standard of 0.11 ppm in 99–100% of all cases. Predicted levels of CO2 were below the Health Canada standard of 3500 ppm for all simulated cases. Oxygen levels in the room of vent-free heating appliance use were not significantly reduced. The great majority of cases in all DOE regions were associated with relative humidity (RH) levels from all indoor water vapor sources that were less than the EPA-recommended 70% RH maximum to avoid active mold and mildew growth. The conclusion of this investigation is that when installed in accordance with the manufacturer’s instructions, vent-free gas heating appliances maintain acceptable indoor air quality in tight energy-efficient homes, as defined by the standards referenced in this report.

Implications: Probabilistic modeling of indoor air concentrations of carbon monoxide (CO), nitrogen dioxide (NO2), carbon dioxide (CO2), water vapor, and oxygen associated with use of vent-free gas heating appliances provides new data indicating that uses of these devices are consistent with acceptable indoor air quality in “tight” energy-efficient homes in the United States. This study will provide authoritative bodies such as the International Code Council with definitive information that will assist in the development of future versions of national building codes, and will provide evaluation of the performance of unvented gas heating products in energy conservation homes.  相似文献   


9.
Although PCB in caulking materials has been forbidden for many years in most of Europe, including Denmark, there has been continued interest to measure PCB levels in the air of contaminated buildings and blood of the occupants (Mengon and Schlatter 1993, Fromme et al. 1996, Ewers et al. 1998, Currado and Harrad 1998, Gabrio et al. 2000). The relatively low priority for investigations of this contamination is probably due to the small quantities inhaled compared to exposure via food, and the rapid metabolism of the most volatile congeners demonstrated by low concentrations of all congeners in the blood of exposed persons (Ewers et al. 1998, Gabrio et al. 2000). There is, however, evidence that PCB containing caulking materials have been used even during the '90s (Fromme et al. 1996). In Denmark, it is estimated that 75 t PCB is still in buildings (Organization of Sealant Branch's Manufacturers and Distributors 2000). During an investigation of dust from buildings with excessive microbial growth (including 35 rooms from 9 buildings), the analysis of semivolatile compounds by thermal desorption-GC/MS of samples from a single building surprisingly revealed large amounts of PCBs containing 3, 4 and 5 chlorine atoms, 10-20 times the amounts found in samples from other buildings. Extraction of the dust by SFE followed by GC/ECD analysis for 12 PCB congeners showed that there was approximately 20 times the total PCB concentrations in dust from the polluted building compared to the levels in the other buildings. Subsequent headspace analysis of caulking material from the polluted building revealed this to be the source. Shelf dust functions as a passive sampling medium and, thus, can be used as a screening method to detect PCB and other semivolatile pollution indoors.  相似文献   

10.
Sediment samples from 23 sampling stations in Nissum Broad (Jutland, Denmark) have been analysed for their contents of 8 organophosphorus compounds: 4 pesticides and 4 related triesters.Only in a few samples, all collected within a short distance from a pesticide manufacturing plant, detectable levels of organophosphates have been observed. The levels ranged from less than 1 μg/kg (ppb) up to 3, 8 mg/kg (ppm) for single compounds.One compound, triethylphosphate, occurred at low concentrations (<1 ppb) in many sediment samples independently of the distance from the chemical plant. Assumably, for this compound, other sources of pollution than the chemical plant may be considered.  相似文献   

11.
An office containing about 65 employees was found to have 8-h average CO concentrations of 18-26 ppm during a week in winter. On one Friday afternoon, 20 nonsmoking office workers had alveolar CO levels of 23 ± 3 ppm compared to levels of 8 ± 2 ppm in six nonsmoking workers in other offices in the same building. After a weekend at home, the affected office workers displayed reduced alveolar CO levels of 7 ± 2 ppm. The source of the high CO levels was attributed to a parking garage on the same level as the office. Closing fire doors and activating garage fans rectified the situation. The breath sampling method is found to require a correction factor based on the difference between the true alveolar CO and the CO level in the surrounding air. The methods and equipment employed in this study (personal air monitors, electronic data loggers, breath sampling) are recommended for screening and identifying potential CO problems in buildings with similar conditions.  相似文献   

12.
Abstract

To evaluate methods of reducing exposure of school children in southwest Mexico City to ambient ozone, outdoor ozone levels were compared to indoor levels under three distinct classroom conditions: windows/doors open, air cleaner off; windows/doors closed, air cleaner off; windows/ doors closed, air cleaner on. Repeated two-minute average measurements of ozone were made within five minutes of each other inside and outside of six different school classrooms while children were in the room. Outdoor ozone two-minute average levels varied between 64 and 361 ppb; mean outdoor levels were above 160 ppb for each of the three conditions. Adjusting for outdoor relative humidity, for a mean outdoor ozone concentration of 170 ppb, the mean predicted indoor ozone concentrations were 125.3 (±5.7) ppb with windows/doors open; 35.4 (±4.6) ppb with windows/ doors closed, air cleaner off; and 28.9 (±4.3) ppb with windows/ doors closed, air cleaner on. The mean predicted ratios of indoor to outdoor ozone concentrations were 0.71 (±0.03) with windows/doors open; 0.18 (±0.02) ppb with windows/doors closed, air cleaner off; and 0.15 (±0.02) ppb with windows/doors closed, air cleaner on. As outdoor ozone concentrations increased, indoor ozone concentrations increased more rapidly with windows and doors open than with windows and doors closed. Ozone exposure in Mexican schools may be significantly reduced, and can usually be kept below the World Health Organization (WHO) guideline of 80 ppb, by closing windows and doors even when ambient ozone levels reach 30Q ppb or more.  相似文献   

13.
Intensive field investigations were conducted at the summit of Mount Tai in June 2006 to understand the effects of the local and regional sources on atmospheric volatile organic compounds (VOCs) distributions. A total of 60 samples were collected and determined by quantitative analytical methods. The concentrations of the total VOCs (TVOCs) observed in the air of Mount Tai were 6.95 ± 5.71 ppb. Aromatic hydrocarbons provided the largest contribution to TVOCs, followed by alkanes and halocarbons. High levels of halocarbons accounted for 20% of TVOCs due to emission from a PVC plant located at the foot of Mount Tai. Alkenes and cycloalkanes contributed little to the total VOCs. The day-and-night differences and day-to-day variations in the concentrations of four selected species were investigated and the effects of several factors such as meteorological parameters, sources and transport characteristics on them were discussed in details. A back trajectory analysis showed that relatively higher levels of VOCs were related to long-range transport of pollutants from polluted areas. The vertical motions of air masses also had a large impact on the variations of the levels of VOCs. The result of the variability–lifetime relationships of VOCs, which is used to estimate the remoteness of the sampling location, showed that Mount Tai represents intermediate conditions between remote sites and sites in the vicinity of sources.  相似文献   

14.
Goal, Scope and Background Cadavers for gross anatomy laboratories are usually prepared by using embalming fluid which contains formaldehyde (FA) as a principal component. During the process of dissection, FA vapors are emitted from the cadavers, resulting in the exposure of medical students and their instructors to elevated levels of FA in the laboratory. The American Conference of Governmental Industrial Hygienists (ACGIH) has set a ceiling limit for FA at 0.3 ppm. In Japan, the Ministry of Health, Labour and Welfare has set an air quality guideline defining two limit values for environmental exposure to FA: 0.08 ppm as an average for general workplaces and 0.25 ppm for specific workplaces such as an FA factory. Although there are many reports on indoor FA concentrations in gross anatomy laboratories, only a few reports have described personal FA exposure levels. The purpose of the present study was to clarify personal exposure levels as well as indoor FA concentrations in our laboratory in order to investigate the relationship between them. Methods The gross anatomy laboratory was evaluated in the 4th, 10th and 18th sessions of 20 laboratory sessions in total over a period of 10 weeks. Air samples were collected using a diffusive sampling device for organic carbonyl compounds. Area samples were taken in the center and four corners of the laboratory during the entire time of each session (4-6 hours). Personal samples were collected from instructors and students using a sampling device pinned on each person's lapel, and they were 1.1 to 6 hours in duration. Analysis was carried out using high performance liquid chromatography. Results and Discussion Room averages of FA concentrations were 0.45, 0.38 and 0.68 ppm for the 4th, 10th and 18th sessions, respectively, ranging from 0.23 to 1.03 ppm. These levels were comparable to or relatively lower than the levels reported previously, but were still higher than the guideline limit for specific workplaces in Japan and the ACGIH ceiling limit. The indoor FA concentrations varied depending on the contents of laboratory sessions and seemed to increase when body cavity or deep structures were being dissected. In all sessions but the 4th, FA levels at the center of the room were higher than those in the corners. This might be related to the arrangement of air supply diffusers and return grills. However, it cannot be ruled out that FA levels in the corners were lowered by leakage of FA through the doors and windows. Average personal exposure levels were 0.80, 0.45 and 0.51 ppm for instructors and 1.02, 1.08 and 0.89 ppm for students for the 4th, 10th and 18th session, respectively. The exposure levels of students were significantly higher than the mean indoor FA concentrations in the 4th and 10th sessions, and the same tendency was also observed in the 18th session. The personal exposure level of instructors was also significantly higher than the indoor FA level in the 4th session, while they were almost the same in the 10th and 18th sessions. Differences in behavior during the sessions might reflect the differential personal exposure levels between students and instructors. Conclusion The present study revealed that, if a person is close to the cadavers during the gross anatomy laboratory, his/her personal exposure level is possibly 2 to 3-fold higher than the mean indoor FA concentration. This should be considered in the risk assessment of FA in gross anatomy laboratories. Recommendation and Outlook If the risk of FA in gross anatomy laboratories is assessed based on the indoor FA levels, the possibility that personal exposure levels are 2 to 3-fold higher than the mean indoor FA level should be taken into account. Otherwise, the risk should be assessed based on the personal exposure levels. However, it is hard to measure everyone's exposure level. Therefore, further studies are necessary to develop a method of personal exposure assessment from the indoor FA concentration.  相似文献   

15.
The formation of cyano group-containing polycyclic aromatic compounds (cyanoarenes) and nitrogen-containing aromatic compounds (azaarenes) during combustion processes is described. The experiments were carried out by combustion of nitrogen containing polymers (nylon 6, polyacrylonitrile and polyamide) in a combustion chamber ,to simulate combustion processes of waste incineration plants. The result from experiments, in which only one nitrogen containing polymer was burnt, showed the formation of several cyanoarenes. We conclude that during combustion processes in which hydrogen cyanide is formed, air pollution by cyanoarenes and azaarenes (in ppb or ppm concentrations) may occur.  相似文献   

16.
The effects of elevated concentrations of atmospheric tropospheric ozone (O3) on DNA damage in five trembling aspen (Populus tremuloides Michx.) clones growing in a free-air enrichment experiment in the presence and absence of elevated concentrations of carbon dioxide (CO2) were examined. Growing season mean hourly O3 concentrations were 36.3 and 47.3 ppb for ambient and elevated O3 plots, respectively. The 4th highest daily maximum 8-h ambient and elevated O3 concentrations were 79 and 89 ppb, respectively. Elevated CO2 averaged 524 ppm (+150 ppm) over the growing season. Exposure to O3 and CO2 in combination with O3 increased DNA damage levels above background as measured by the comet assay. Ozone-tolerant clones 271 and 8L showed the highest levels of DNA damage under elevated O3 compared with ambient air; whereas less tolerant clone 216 and sensitive clones 42E and 259 had comparably lower levels of DNA damage with no significant differences between elevated O3 and ambient air. Clone 8L was demonstrated to have the highest level of excision DNA repair. In addition, clone 271 had the highest level of oxidative damage as measured by lipid peroxidation. The results suggest that variation in cellular responses to DNA damage between aspen clones may contribute to O3 tolerance or sensitivity.  相似文献   

17.
Human breath emissions of VOCs.   总被引:5,自引:0,他引:5  
The medical community has long recognized that humans exhale volatile organic compounds (VOCs). Several studies have quantified emissions of VOCs from human breath, with values ranging widely due to variation between and within individuals. The authors have measured human breath concentrations of isoprene and pentane. The major VOCs in the breath of healthy individuals are isoprene (12-580 ppb), acetone (1.2-1,880 ppb), ethanol (13-1,000 ppb), methanol (160-2,000 ppb) and other alcohols. In this study, we give a brief summary of VOC measurements in human breath and discuss their implications for indoor concentrations of these compounds, their contributions to regional and global emissions budgets, and potential ambient air sampling artifacts. Though human breath emissions are a negligible source of VOCs on regional and global scales (less than 4% and 0.3%, respectively), simple box model calculations indicate that they may become an important (and sometimes major) indoor source of VOCs under crowded conditions. Human breath emissions are generally not taken into account in indoor air studies, and results from this study suggest that they should be.  相似文献   

18.
The performance of gaseous air cleaners for commercial and residential buildings has typically been evaluated using test protocols developed for a controlled laboratory chamber or a test duct. It is currently unknown how laboratory measurements relate to the actual performance of an air cleaner installed in a real building. However, to date, there are no air cleaner field test protocols available, thereby limiting the existing field data. The National Institute of Standards and Technology (NIST) has conducted a series of experiments to support test procedure development for evaluating the installed performance of gaseous air cleaning equipment, as well as metrics for characterizing field performance. To date, over 100 experiments have been completed, of which 23 portable air cleaner experiments and 6 in-duct air cleaner experiments are described in this paper. Tests were conducted in a finished three-bedroom/two-bathroom manufactured house equipped with several gas chromatographs to semi-continuously measure air change rates and volatile organic compound concentrations. Experimental variables included air cleaner location, isolation of zones by closing doors, and contaminant source location. For each experiment, air cleaner removal of decane was directly measured using the air cleaner inlet and outlet concentrations, as well as with mass balance analyses using measured room concentrations. With a verified mass balance model, a field performance metric was developed to compare installed whole-building performance to the performance predicted by a laboratory result. The results provide insight into the protocols and metrics that might prove useful for characterizing the field performance of air cleaners as well as the impact of air cleaner removal on zonal concentration levels in a variety of situations.  相似文献   

19.
Combustion emissions and strong Santa Ana winds had pronounced effects on patterns and levels of ambient ozone (O3) in southern California during the extensive wildland fires of October 2007. These changes are described in detail for a rural receptor site, the Santa Margarita Ecological Reserve, located among large fires in San Diego and Orange counties. In addition, O3 changes are also described for several other air quality monitoring sites in the general area of the fires. During the first phase of the fires, strong, dry and hot northeasterly Santa Ana winds brought into the area clean continental air masses, which resulted in minimal diurnal O3 fluctuations and a 72-h average concentration of 36.8 ppb. During the second phase of the fires, without Santa Ana winds present and air filled with smoke, daytime O3 concentrations steadily increased and reached 95.2 ppb while the lowest nighttime levels returned to ~0 ppb. During that period the 8-h daytime average O3 concentration reached 78.3 ppb, which exceeded the federal standard of 75 ppb. After six days of fires, O3 diurnal concentrations returned to pre-fire patterns and levels.  相似文献   

20.
An ozone (O3) exposure study was conducted in Nashville, TN, using passive O3 samplers to measure six weekly outdoor, indoor, and personal O3 exposure estimates for a group of 10- to 12-yr-old elementary school children. Thirty-six children from two Nashville area communities (Inglewood and Hendersonville) participated in the O3 sampling program, and 99 children provided additional time-activity information by telephone interview. By design, this study coincided with the 1994 Nashville/Middle Tennessee Ozone Study conducted by the Southern Oxidants Study, which provided enhanced continuous ambient O3 monitoring across the Nashville area. Passive sampling estimated weekly average outdoor O3 concentrations from 0.011 to 0.O30 ppm in the urban Inglewood community and from 0.015 to 0.042 ppm in suburban Hendersonville. The maximum 1- and 8-hr ambient concentrations encountered at the Hendersonville continuous monitor exceeded the levels of the 1- and 8-hr metrics for the O3 National Ambient Air Quality Standard. Weekly average personal O3 exposures ranged from 0.0013 to 0.0064 ppm (7-31% of outdoor levels). Personal O3 exposures reflected the proportional amount of time spent in indoor and outdoor environments. Air-conditioned homes displayed very low indoor O3 concentrations, and homes using open windows and fans for ventilation displayed much higher concentrations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号