首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
3.
4.
5.
6.
7.
This paper describes a portable, low-cost whole air sampler capable of collecting 12 1-L samples in tedlar bags and using a single "D" cell for power. The results are presented from two tests of an intensive sampling and analysis method for measuring ambient carbon monoxide (CO) concentrations in urban areas using this sampler. The method is evaluated in comparison with an approved continuous CO analyzer, in intercomparisons of the results of re-analysis of the samples, and by examination of the results from co-located samplers. The precision of the analytical method was found to be +/-0.30 ppmv. The precision of the sampling method was found to be +/-0.73 ppmv and therefore is the limiting factor in the method's overall precision. These values are sufficient to verify attainment of National Ambient Air Quality Standards (NAAQS) levels in urban areas. Improvements in the sampler and analytical procedure are discussed.  相似文献   

8.
9.
An episode selection procedure was developed and applied to select sets of days representing characteristic meteorological conditions leading to high ozone episodes over the Swiss Plateau. The selection procedure was applied to data extending from January 1991 through December 1998, and is comprised of two steps: First, days were classified according to observed air quality and meteorological characteristics using classification and regression trees analysis (CART). Second, the CART results were used in conjunction with observed air quality data to identify sets of days characteristic of those leading to elevated ozone. These sets of days were selected to optimise how well a limited number of days represented seasonal air quality, and that formed longer episodes for use in the air quality modelling. CART analysis was performed for three zones of the Swiss Plateau that have different air quality and meteorological characteristics. The results for two zones were used together in the episode selection procedure in order to identify days representative for the whole Plateau. Meteorological analysis for a third zone suggested that it would be strongly impacted by pollutants transported in from outside the country. One thousand and eight hundred optimisation runs were performed to minimise the likelihood that the set of days was a local optimum, increasing the robustness for use in air quality modelling analysis. Fifteen days, grouped in four episodes ranging from 3 to 5 days were selected along with their calculated representativeness (or weight) to recreate a seasonal metric. The variety of local as well as regional meteorological characteristics showed that the episode selection procedure chose days representing a diverse set of meteorological situations which are associated with elevated ozone. This set of episodes can now be used to test air quality strategies.  相似文献   

10.
Carbon monoxide monitoring using continuous samplers is carried out in most major urban centres in the world and generally forms the basis for air quality assessments. Such assessments become less reliable as the proportion of data missing due to equipment failure and periods of calibration increases. This paper presents a semi-empirical model for the prediction of atmospheric carbon monoxide concentrations near roads for the purpose of interpolating missing data without the need for any traffic or emissions information. The model produces reliable predictions while remaining computationally simple by being site-specifically optimized. The model was developed for, and evaluated at, both a suburban site and an inner city site in Hamilton, New Zealand. Model performance statistics were found to be significantly better than other simple methods of interpolation with little additional computational complexity.  相似文献   

11.
Three CO instruments, i.e., vacuum ultraviolet resonance fluorescence (VUV-RF), gas chromatography/reduction gas detection (GC/RGD), and non-dispersive infrared (NDIR) spectrometry, were inter-compared at a background site, i.e., Lulin Atmospheric Baseline Station (LABS) in central Taiwan. For a period of 18 days of continuous measurements, highly coherent results were observed between the three instruments. Calibration of the GC/RGD and VUV-RF was based on the same batch of CO standards, producing results that agreed within 4%. Nevertheless, NDIR displayed a significant bias with a large offset compared to the other two instruments (about ?63.1 ppb), due mainly to its over-simplified calibration procedure. The NDIR bias was then removed by aligning the NDIR data to those of GC/RGD in a process termed “post-run correction”. Through this practice, the NDIR was linked to the same calibration scale as that of GC/RGD. As a result, by simultaneously exploiting both GC/RGD and NDIR to measure background CO, both time-resolution and accuracy can be secured.  相似文献   

12.
13.
14.
The health risks to U.S. populations who are exposed to ambient carbon monoxide and live at altitudes (such as Denver, Salt Lake City and Albuquerque) were evaluated using a set of mathematical models. The assumption that a given increase in carboxyhemoglobin would require a more stringent volumetric air quality standard was tested. The results using the model predict that the 8-h or 1-h standards adopted for sea level conditions need not be altered to protect individuals against health risks at altitude, if the standards are in volumetric terms. They would need to be reduced if the standards are left in gravimetric terms. If the guideline is to be based on a given decrement of oxygen tension, many other variables must be specified, but expected differences in ambient carbon monoxide have a small impact compared to the effect of altitude itself.  相似文献   

15.
16.
There are two principal approaches to the 8-hour carbon monoxide standard: (1) 8-hour moving averages that culminate with every clock hour, and (2) nonoverlapping averages for consecutive 8-hour intervals. Examination of 1972 data for three example sites (Newark, NJ, Camden, NJ, and Spokane, WA) shows that the maximum and the “second high” control values derived from moving averages can be at least 20% higher than corresponding values detected by the consecutive 8-hour intervals. The natural fluctuation in the time of day when the maximum occurs and the variability in episode length make it doubtful that any framework of consecutive 8-hour intervals can adequately portray the essential characteristics of CO exposure. Prudence recommends choice of the moving 8-hour average as more sensitive to actual maximum levels and to short episodes, more faithful to the body’s integrating response to CO exposure, and more equitable in presenting comparisons among stations with differing patterns of daily variation.  相似文献   

17.
The concentrations of carbon monoxide (CO) and other gases were measured in the emissions from solid waste degradation under aerobic and anaerobic conditions during laboratory and field investigations. The emissions were measured as room temperature headspace gas concentrations in reactors of 1, 30, and 150 L, as well as sucked gas concentrations from windrow composting piles and a biocell, under field conditions. The aerobic composting laboratory experiments consisted of treatments with and without lime. The CO concentrations measured during anaerobic conditions varied from 0 to 3000 ppm, the average being 23 ppm, increasing to 133 ppm when methane (CH4) concentrations were low. The mean/maximum CO concentrations during the aerobic degradation in the 2-L reactor were 101/194 ppm without lime, 486/2022 ppm with lime, and 275/980 ppm in the 150-L reactors. The presence of CO during the aerobic composting followed a rapid decline in O2 concentrations Significantly higher CO concentrations were obtained when the aerobic degradation was amended with lime, probably because of a more extreme depletion of oxygen. The mean/maximum CO concentrations under field conditions during aerobic composting were 95/1000 ppm. The CO concentrations from the anaerobic biocell varied from 20 to 160 ppm. The hydrogen sulfide concentrations reached almost 1200 ppm during the anaerobic degradation and 67 ppm during the composting experiments.  相似文献   

18.
Analysis of carbon monoxide budget in North China   总被引:1,自引:0,他引:1  
Peng L  Zhao C  Lin Y  Zheng X  Tie X  Chan LY 《Chemosphere》2007,66(8):1383-1389
A global chemical transport model (MOZART-2; model of ozone and related tracers, version 2) was used to assess physical and chemical processes that control the budget of tropospheric carbon monoxide (CO) in North China. Satellite observations of CO from the measurements of pollution in the troposphere (MOPITT) instrument are combined with model results for the analysis. The comparison between the model simulations and the satellite observations of total column CO (TCO) shows that the model can reproduce the spatial and temporal distributions. However, the model results underestimate TCO by 23% in North China. This underestimation of TCO may be caused by the uncertainties of emissions. The tropospheric CO budget analysis suggests that in North China, surface emission is the largest source of tropospheric CO. The main sinks of tropospheric CO in this region are chemical reaction and stratosphere_and_troposphere exchange. The analysis also shows that most of inflow CO to Pacific regions comes from the upwind regions of North China. This transport of CO is significant during Winter and Spring time.  相似文献   

19.
采用联合式催化剂新技术,在低温下进行了一氧化碳和氢化同消除的试验,通过实验考察取得了良好的效果。  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏