首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
3.
4.
5.
The Journal of the Air Pollution Control Association presents its fifth annual directory of air pollution products. This 14-page guide lists manufacturers of emission control equipment and air pollution instrumentation under product classifications which are shown below. These classifications are derived from McGraw-Hill’s Air Pollution Handbook, chapters 10, 11, and 13 . The final portion of this guide contains an alphabetical listing of manufacturers.

If any manufacturers or product categories have been inadvertently overlooked, the omission is regretted and should be brought to the attention of the editor. It will result in a more complete and accurate Product Guide/1973 to be published next December.  相似文献   

6.
7.
The Product Guide series which appears in the Journal of the Air Pollution Control Association and the APCA Directory and Resource Book is a computer-based program. A questionnaire form provided entry into the program for responding manufacturers of emission control equipment and air pollution instrumentation. If any manufacturers or product categories have been overlooked, the omission is regretted and should be brought to the attention of the editor, JAPCA.  相似文献   

8.
Abstract

An efficient venturi scrubber system making use of heterogeneous nucleation and condensational growth of particles was designed and tested to remove fine particles from the exhaust of a local scrubber where residual SiH4 gas was abated and lots of fine SiO2 particles were generated. In front of the venturi scrubber, normal-temperature fine-water mist mixes with high-temperature exhaust gas to cool it to the saturation temperature, allowing submicron particles to grow into micron sizes. The grown particles are then scrubbed efficiently in the venturi scrubber. Test results show that the present venturi scrubber system is effective for removing submicron particles. For SiO2 particles greater than 0.1 μm, the removal efficiency is greater than 80–90%, depending on particle concentration. The corresponding pressure drop is relatively low. For example, the pressure drop of the venturi scrubber is ~15.4 ± 2.4 cm H2O when the liquid-to-gas ratio is 1.50 L/m3. A theoretical calculation has been conducted to simulate particle growth process and the removal efficiency of the venturi scrubber. The theoretical results agree with the experimental data reasonably well when SiO2 particle diameter is greater than 0.1 μm.  相似文献   

9.
Measurements conducted on full-scale hazardous waste incinerators have occasionally shown a relationship between carbon monoxide (CO) emissions and emissions of toxic organic compounds. In this study, four mixtures of chlorinated C1 and C2 hydrocarbons were diluted in commercial-grade heptane and burned in a water-cooled turbulent flame reactor (TFR) under two different excess air levels. No correlation between CO and organic emissions could be discerned. Reasons for this lack of observable correlations are discussed in terms of combustion and chemical reaction kinetic theory.  相似文献   

10.
11.
12.
13.
Investigation, mitigation, and clean-up of hazardous materials at Superfund sites normally requires on-site workers to perform hazardous and sometimes potentially dangerous functions. Such functions include site surveys and the reconnaissance for airborne and buried toxic environmental contaminants. Airborne contaminants of concern usually emanate from spilled materials and require monitoring the air at the perimeter and throughout the clean-up site to ascertain the extent of contamination. Buried contaminants of major concern are often the result of leaking underground drums containing toxic wastes and require "reconnaissance excavations" to determine their location. Workers conducting on-site air monitoring risk dermal, ocular and inhalation exposure to hazardous chemicals, while those performing excavations also risk the potential exposure to fire, explosion, and other physical injury. EPA's current efforts to protect its workers and mitigate these risks include the use of robotic devices. Using robots offers the ultimate in personnel protection by removing the worker from the site of potential exposure, especially during site investigations, when there is almost always a certain encounter with unknown chemical wastes having unknown toxicity.

This paper describes the demonstration of a commercially-available robotic plat form modified and equipped for air monitoring and the ongoing research for the development of a ground penetrating radar (GPR) system to detect buried chemical waste drums. These robotic devices can ultimately be routinely deployed in the field for the purpose of conducting inherently safe reconnaissance activities during Superfund / SARA remedial operations.  相似文献   

14.
The Journal of the Air Pollution Control Association presents its second animal directory of air pollution products. This 11-page guide lists manufacturers of emission control equipment and air pollution instrumentation under product classifications which are shown below. These classifications are derived from McGraw-Hill’s Air Pollution Handbook, chapters 10, 11, and 13. The final portion of this guide contains an alphabetical listing of manufacturers.If any manufacturers or product categories have been inadvertently overlooked, the omission is regretted and should be brought to the attention of the editor. It will result in a more complete and accurate Product Guide/1970 to be published next December.  相似文献   

15.
Trace element concentrations of the lichen, Flavoparmelia caperata, were determined by neutron activation analysis before and after stringent participate controls were employed in an industrialized section of the Ohio River Valley; Initial studies in 1973 showed elevated concentrations of arsenic, cobalt, iron, vanadium, and titanium in lichens collected near coalfired power plants. Elevated values for cerium, chromium, and lanthanum were found in samples near a ferro-alloys foundry. A repeat study in 1987 demonstrated that lichen trace element concentrations were much lower after improved particulate controls were installed on the power plants and ferro-alloys foundry.  相似文献   

16.
Abstract

The impact of weather on air pollution was examined and evaluated for the city of Athens, Greece. We used an objectively defined synoptic classification scheme consisting of six summer and eight winter circulation types. This scheme was established using a combination of both factor and cluster analysis during 1954–1999. Surface and isobaric levels of 850 hPa data were used. Factor analysis combined with cluster analysis was used to derive circulation types based on surface meteorological data for the period 1954–1999 in Athens and on surface pressure grid data. The city was divided into three sectors according to the financial and social activities of the residents. To examine the spatial characteristics of pollutant concentrations over Athens for each synoptic type, the synoptic circulation types were then correlated with both gaseous and particulate pollutant concentrations measured in each sector between 1983 and 1999. Finally, extreme and severe episodic events were studied in terms of their meteorological and synoptic characteristics.  相似文献   

17.
18.
19.
20.
The European Economic Community (EEC) has proposed strict limits on emissions of dioxins and furans from hazardous waste incinerators. The proposed limit is 0.1 ng/Nm3, expressed as the 2,3,7,8 TCDD toxic equivalent of 17 specific dioxin and furan congeners. These limits will potentially redefine technology selection and design for combustion, energy recovery, and air pollution control. The EPA has a different approach for controlling emissions of products of incomplete combustion (PICs) and reformation products such as dioxins and furans. Rather than limiting these contaminants individually and quantitatively, EPA proposes controlling them by assuring good combustion as measured by stack emissions of carbon monoxide (CO) and total hydrocarbons (THC).

Dioxins and furans are combustion by-products and emission control relies mainly on control of the combustion process. These compounds can also be reformed from certain precursor compounds and elements in lower temperature regions of the system downstream of the combustion process. Air pollution control technologies have demonstrated the ability to remove dioxins and furans as contaminants on fine particulate.

This paper will discuss the two regulatory approaches, the mechanisms for the formation and reformation of dioxins and furans, and the technologies available to control emissions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏