首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
2.
3.
4.
5.
6.
7.
8.
A decision support system has been developed for urban air quality management in the metropolitan area of Istanbul. The system is based on CALMET/CALPUFF dispersion modeling system, digital maps, and related databases to estimate the emissions and spatial distribution of air pollutants with the help of a GIS software. The system estimates ambient air pollution levels at high temporal and spatial resolutions and enables mapping of emissions and air quality levels. Mapping and scenario results can be compared with air quality limits. Impact assessment of air pollution abatement measures can also be carried out.  相似文献   

9.
An automated air sampling system has been designed for use with the annular denuder system (ADS). The automated air sampling system allows for accurate measurements of air volume and day-night sampling while preventing the accumulation of moisture within the ADS caused by condensation or cloud events. The sampling system consists of air flow, monitoring and control subsystems. Calibration of the sampling system against a Hoffer turbine flow meter indicated accurate measurement of air flow volumes. Field testing and preliminary data have shown that the sampling system functions well in a remote mountain forest site, and was relatively unaffected by condensation, fog, or cloud events.  相似文献   

10.
11.
The Pennsylvania Air Pollution Commission has developed a regulatory program based upon the control of local air pollution problems and reduction of pollutant levels in air basins. The geographical boundaries of 10 air basins have been established. The Commission’s air basin regulations will provide for the reduction of over-all pollutant levels and for emergency procedures in the event of adverse meteorological conditions. The paper discusses the format and objectives of the program.

In order to effectively enforce the air basin regulations and maintain the necessary surveillance of the state’s air quality, a "computerized real time on-line integrated air monitoring-data handling system" has been designed. The system will incorporate a network to constantly monitor the air in each air basin.The primary objectives of the system are: 1. Constant surveillance of air pollution in the air basins.

2. Provide information on air pollution potential alerts.

3. Aid in further development of air quality criteria and regulations.

The air monitoring network is estimated to include approximately 25 remote stations. Each remote will contain air pollution and meteorological sampling equipment and hardware to telemeter to a central station. The data will be transmitted over leased telephone lines. The central station in Harrisburg will contain the necessary hardware to receive and process data, calculate and display results and permit supervisory control of the network. Output options will include immediate display of edited data, command and alarm information, and presentation of statistical results.

Although the air monitoring system is one of the principle ingredients of the program, the air basin concept encompasses other component systems designed to knit together the entire air pollution control program in Pennsylvania.  相似文献   

12.
13.
Nowadays, the heating, ventilation, and air conditioning (HVAC) system has been an important facility for maintaining indoor air quality. However, the primary function of typical HVAC systems is to control the temperature and humidity of the supply air. Most indoor air pollutants, such as volatile organic compounds (VOCs), cannot be removed by typical HVAC systems. Thus, some air handling units for removing VOCs should be added in typical HVAC systems. Among all of the air cleaning techniques used to remove indoor VOCs, photocatalytic oxidation is an attractive alternative technique for indoor air purification and deodorization. The objective of this research is to investigate the VOC removal efficiency of the photocatalytic filter in a HVAC system. Toluene and formaldehyde were chosen as the target pollutants. The experiments were conducted in a stainless steel chamber equipped with a simplified HVAC system. A mechanical filter coated with Degussa P25 titania photocatalyst and two commercial photocatalytic filters were used as the photocatalytic filters in this simplified HVAC system. The total air change rates were controlled at 0.5, 0.75, 1, 1.25, and 1.5 hr(-1), and the relative humidity (RH) was controlled at 30%, 50%, and 70%. The ultraviolet lamp used was a 4-W, ultraviolet-C (central wavelength at 254 nm) strip light bulb. The first-order decay constant of toluene and formaldehyde found in this study ranged from 0.381 to 1.01 hr(-1) under different total air change rates, from 0.34 to 0.433 hr(-1) under different RH, and from 0.381 to 0.433 hr(-1) for different photocatalytic filters.  相似文献   

14.
Abstract

Nowadays, the heating, ventilation, and air conditioning (HVAC) system has been an important facility for maintaining indoor air quality. However, the primary function of typical HVAC systems is to control the temperature and humidity of the supply air. Most indoor air pollutants, such as volatile organic compounds (VOCs), cannot be removed by typical HVAC systems. Thus, some air handling units for removing VOCs should be added in typical HVAC systems. Among all of the air cleaning techniques used to remove indoor VOCs, photocatalytic oxidation is an attractive alternative technique for indoor air purification and deodorization. The objective of this research is to investigate the VOC removal efficiency of the photocatalytic filter in a HVAC system. Toluene and formaldehyde were chosen as the target pollutants. The experiments were conducted in a stainless steel chamber equipped with a simplified HVAC system. A mechanical filter coated with Degussa P25 titania photocatalyst and two commercial photocatalytic filters were used as the photo-catalytic filters in this simplified HVAC system. The total air change rates were controlled at 0.5, 0.75, 1, 1.25, and 1.5 hr?1, and the relative humidity (RH) was controlled at 30%, 50%, and 70%. The ultraviolet lamp used was a 4-W, ultraviolet-C (central wavelength at 254 nm) strip light bulb. The first-order decay constant of toluene and form-aldehyde found in this study ranged from 0.381 to 1.01 hr?1 under different total air change rates, from 0.34 to 0.433 hr?1 under different RH, and from 0.381 to 0.433 hr?1 for different photocatalytic filters.  相似文献   

15.
16.
17.
18.
This paper considers the evolution of attempts to control and manage air pollution, principally but not exclusively focussing upon the challenge of managing air pollution in urban environments. The development and implementation of a range of air pollution control measures are considered. Initially the measures implemented primarily addressed point sources, a small number of fuel types and a limited number of pollutants. The adequacy of such a source-control approach is assessed within the context of a changing and challenging air pollution climate. An assessment of air quality management in the United Kingdom over a 50-year timeframe exemplifies the range of issues and challenges in contemporary air quality management. The need for new approaches is explored and the development and implementation of an effects-based, risk management system for air quality regulation is evaluated.  相似文献   

19.
20.
Contributions of the emissions from a U.K. regulated fossil-fuel power station to regional air pollution and deposition are estimated using four air quality modeling systems for the year 2003. The modeling systems vary in complexity and emphasis in the way they treat atmospheric and chemical processes, and include the Community Multiscale Air Quality (CMAQ) modeling system in its versions 4.6 and 4.7, a nested modeling system that combines long- and short-range impacts (referred to as TRACK-ADMS [Trajectory Model with Atmospheric Chemical Kinetics-Atmospheric Dispersion Modelling System]), and the Fine Resolution Atmospheric Multi-pollutant Exchange (FRAME) model. An evaluation of the baseline calculations against U.K. monitoring network data is performed. The CMAQ modeling system version 4.6 data set is selected as the reference data set for the model footprint comparison. The annual mean air concentration and total deposition footprints are summarized for each modeling system. The footprints of the power station emissions can account for a significant fraction of the local impacts for some species (e.g., more than 50% for SO2 air concentration and non-sea-salt sulfur deposition close to the source) for 2003. The spatial correlation and the coefficient of variation of the root mean square error (CVRMSE) are calculated between each model footprint and that calculated by the CMAQ modeling system version 4.6. The correlation coefficient quantifies model agreement in terms of spatial patterns, and the CVRMSE measures the magnitude of the difference between model footprints. Possible reasons for the differences between model results are discussed. Finally, implications and recommendations for the regulatory assessment of the impact of major industrial sources using regional air quality modeling systems are discussed in the light of results from this case study.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号