1.
In 2-stage precipitators particles are driven to the collecting plates by electrostatic forces but then the electrostatic force reverses and tends to pull the particles off so that dust is held on the collecting electrodes only by adhesion. In Cottrell or single-stage precipitators the corona current can provide a significant force tending to hold the collected dust to the electrode provided that the resistivity of the dust is 1010 ohm-cm or more. Adhesion is still essential in the collection of lower resistivity dust and is of vital importance in the transfer of dust from the collecting electrodes to the hopper. As the dust falls from the plates to the hopper it must be held in agglomerations or chunks. There are many peculiarities in the adhesive behavior of electrostatically collected dust. A better understanding of this adhesive behavior is essential if we are to improve the transfer of dust from the collecting electrodes to the hopper.  相似文献   

2.
姚伟  韦巍 《环境工程学报》2012,6(2):561-565
为了进一步提高静电除尘器的收尘效率、降低能耗,对粉尘比电阻这一重要影响因素进行了研究。依据粉尘比电阻值定义,建立了收尘极板上粉尘层压降模型,提出了利用压降模型和伏安拟合特性曲线数学表征式来在线测算真实工况下粉尘层比电阻的实现方法。以480C型阳极板、RS芒刺阴极线极配形式进行了模拟验证实验,结果表明测算所得的比电阻数值与实际值相符。最后对现有电除尘控制系统中基于比电阻值的反馈控制方法做了简要介绍。  相似文献   

3.
This paper develops an expression for the resistivity of a dust layer which takes into account its particulate nature, dependence of the surface resistivity component on water vapor pressure and temperature, the volume resistivity and the intrinsic properties of the particulate material. A new expression is given for the surface resistivity which, when combined with the equation for volume resistivity, enables the effective resistance of a dust layer to be characterized by five meaningful parameters. These parameters may be determined for a given fly ash sample from a standard set of resistivity curves. Calculated resistivity curves for an industrially produced fly ash are compared with measured curves.  相似文献   

4.
The suppression of corona by particle space-charge is of considerable importance in electrostatic precipitators dealing with medium to high concentrations of particulates. However, the effect of the dust concentration on collection efficiency has found no direct answer in the literature. In addition to the expected reduction in corona current due to low mobility dust particles, the presence of these charged particles has two other main effects: 1. The electric field in the vicinity of the discharge electrode is weakened and hence the concentration of ions originating in the ionization zone and forming the charging current is decreased. 2. The resulting space-charge build-up causes an increase in the field strength adjacent to the collecting surface of the precipitator. The importance of each of these effects on the collection efficiency will be dependent on the relative decrease in particle charge as compared to the increase in the collection field. Experiments were carried out under both positive and negative corona with aerosol concentrations having specific surfaces in the range 0 to 44 m2/m3. These results showed: 1. For low values of corona current densities, as the specific surface area increases, the efficiency decreases. In this cqse, the charge per particle decreases as the particle concentration increases and becomes far below the normal charge attainable. Here the increase in the collection field is more than counteracted by the jarge reduction in particle charge. 2. For higher values of initial corona current densities, as the particle specific surface area increases, the efficiency either increases slightly or stays constant, in spite of major reductions in the measured corona current. In this case there should also be a reduction in the charge per particle with the increase in particle concentration, however, this is apparently offset by the increase in the collection field strength. Analysis of the results, coupled with an interpretation of existing theories, indicates that a major parameter that must be considered is the ratio of the initial corona current density and the specific surface of the particles.  相似文献   

5.
Abstract

Approximately 750 total suspended particulates (TSPs) and coarse particulate matter (PM10) filter samples from six urban sites and a background site and >210 source samples were collected in Jiaozuo City during January 2002 to April 2003. They were analyzed for mass and abundances of 25 chemical components. Seven contributive sources were identified, and their contributions to ambient TSP/PM10 levels at the seven sites in three seasons (spring, summer, and winter days) and a “whole” year were estimated by a chemical mass balance (CMB) receptor model. The spatial TSP average was high in spring and winter days at a level of approximately 530 ~g/m3 and low in summer days at 456 ~g/m3; however, the spatial PM10 average exhibited little variation at a level of approximately 325 ~g/m3, and PM10-to-TSP ratios ranged from 0.58 to 0.81, which suggested heavy particulate matter pollution existing in the urban areas. Apportionment results indicated that geological material was the largest contributor to ambient TSP/PM10 concentrations, followed by dust emissions from construction activities, coal combustion, secondary aerosols, vehicle movement, and other industrial sources. In addition, paved road dust and re-entrained dust were also apportioned to the seven source types and found soil, coal combustion, and construction dust to be the major contributors.  相似文献   

6.
Part I of this work has shown that electrical breakdown in dust layers obeys Paschen's Law, but occurs at applied field values which appear too small to initiate the breakdown. In this paper we will show how an effective dielectric constant characterizing the dust layer can be determined from ac dielectric measurements and the theory of Debye. When combined with an expression for the enhanced local electric field in the void spaces between particles in the layer, field strengths which are large enough to initiate electrical breakdown in the layer are predicted at relatively low values of applied field. The effect of temperature and dust layer thickness on the onset of electrical breakdown within the dust layer can also be explained by the dependence of the effective dielectric constant on these parameters.  相似文献   

7.
A study on source apportionment of indoor dust and particulate matter (PM10) composition was conducted in a university building by using chemometrics. The objective of this study was to investigate the potential sources of selected heavy metals and ionic species in PM10 and indoor dust. PM10 samples were collected using a low-volume sampler (LVS) and indoor dust was collected using a soft brush. Inductively coupled plasma spectrometry (ICP-MS) was used to determine the concentration of heavy metals, while the concentration of cations and anions was determined by atomic absorption spectrometer (AAS) and ion chromatography (IC), respectively. The concentration of PM10 recorded in the building throughout the sampling period ranged from 20 ± 10 μgm?3 to 80 ± 33 μgm?3. The composition of heavy metals in PM10 and indoor dust were dominated by zinc (Zn), followed by lead (Pb), copper (Cu), and cadmium (Cd). Principle component analysis (PCA) and multiple linear regression (MLR) showed that the main sources of pollutants in PM10 came from indoor renovations (73.83%), vehicle emissions (16.38%), earth crust sources (9.68%), and other outdoor sources (0.11%). For indoor dust, the pollutant source was mainly earth crust. This study suggests that chemometrics can be used for forensic investigation to determine the possible sources of indoor contaminants within a public building.  相似文献   

8.
A receptor model of positive matrix factorization (PMF) was used to identify the emission sources of fine and coarse particulates in Bandung, a city located at about 150 km south-east of Jakarta. Total of 367 samples were collected at urban mixed site, Tegalega area, in Bandung City during wet and dry season in the period of 2001–2007. The samples of fine and coarse particulate matter were collected simultaneously using dichotomous samplers and mini-volume samplers. The Samples from dichotomous Samplers were analyzed for black carbon and elements while samples from mini-volume samplers were analyzed for ions. The species analyzed in this study were Na, Mg, Al, Si, K, Ca, Ti, Cr, Mn, Fe, Ni, Cu, Pb, Cl?, NO3?, SO42?, and NH4+. The data were then analyzed using PMF to determine the source factors. Different numbers of source factors were found during dry and wet season. During dry season, the main source factors for fine particles were secondary aerosol (NH4)2SO4, electroplating industry, vehicle emission, and biomass burning, while for coarse particles, the dominant source factors were electroplating industry, followed by aged sea salt, volcanic dust, soil dust, and lime dust. During the wet season, the main source factors for fine particulate matter were vehicle emission and secondary aerosol. Other sources detected were biomass burning, lime dust, soil and volcanic dust. While for coarse particulate matter, the main source factors were sulphate-rich industry, followed by lime dust, soil dust, industrial emission and construction dust.  相似文献   

9.
Abstract

Particles emitted from gravel processing sites are one contributor to worsening air quality in Taiwan. Major pollution sources at gravel processing sites include gravel and sand piles, unpaved roads, material crushers, and bare ground. This study analyzed fugitive dust emission characteristics at each pollution source using several types of particle samplers, including total suspended particulates (TSP), suspended particulate (PM10), fine suspended particulate (PM2.5), particulate sizer, and dust-fall collectors. Furthermore, silt content and moisture in the gravel were measured to develop particulate emission factors. The results showed that TSP (<100 µm) concentrations at the boundary of gravel sites ranged from 280 to 1290 µg/m3, which clearly exceeds the Taiwan hourly air quality standard of 500 µg/m3. Moreover, PM10 concentrations, ranging from 135 to 550 µg/m3, were also above the daily air quality standard of 125 µg/m3 and approximately 1.2 and 1.5 times the PM2.5 concentrations, ranging from 105 to 470 µg/m3. The size distribution analysis reveals that mass mean diameter and geometric standard deviation ranged from 3.2 to 5.7 µm and from 2.82 to 5.51, respectively. In this study, spraying surfactant was the most effective control strategy to abate windblown dust from unpaved roads, having a control efficiency of approximately 93%, which is significantly higher than using paved road strategies with a control efficiency of approximately 45%. For paved roads, wet suppression provided the best dust control efficiencies ranging from 50 to 83%. Re-vegetation of disturbed ground had dust control efficiencies ranging from 48 to 64%.  相似文献   

10.
A severe problem has developed with respect to the efficiency of certain hot-side electrostatic precipitators. The problem is manifested by a time dependent degradation of performance in which back corona related to a condition of high ash resistivity is the influencing factor. Performance can be restored by thorough cleaning of the precipitator only to experience the degradation once again. This paper hypothesizes an explanation for these observations. Experiments with both high and low resistivity ashes using resistivity test cells and a laboratory corona discharge device have been run to prove the validity of the suggested explanation. Data substantiate the idea that in the precipitation process a thin layer of ash more or less permanently remains on the collection plates and that the sodium ions serving as charge carriers in the conduction process through the layer are depleted leaving a thin layer of ash having extremely high resistivity. This phenomenon is called electrode polarization, sodium depletion, or an ash layer space charge depending on one's scientific discipline. Suggestions of remedial steps which may be of benefit in counteracting this difficulty are given.  相似文献   

11.
One of the important cohesive forces acting on the precipitated layer in an electrostatic precipitator Is that due to the effect of the electric field established in the air gaps between adjacent particles by the corona current as it flows through the layer. A theoretical expression for this force is developed for an idealized dust layer which takes into account the increase in effective contact area between adjacent particles due to elastic deformation and the limiting of the electric field in the airgap to a maximum allowable value. It is shown that the cohesive force is approximately proportional to the electric field established across the layer. This relationship is in general agreement with measurements made in the laboratory using industrially produced dust samples.  相似文献   

12.
Long-term surface observations indicate that soil dust represents over 30% of the annual fine (particle diameter less than 2.5 μm) particulate mass in many areas of the western US; in spring and summer, it represents an even larger fraction. There are numerous dust-producing playas in the western US, but surface dust aerosol concentrations in this region are also influenced by dust of Asian origin. This study examines the seasonality of surface soil dust concentrations at 15 western US sites using observations from the Interagency Monitoring of PROtected Visual Environments (IMPROVE) network from 2001 to 2004. Average soil concentrations in particulate matter less than 10 μm in diameter (PM10) were lowest in winter and peaked during the summer months at these sites; however, episodic higher-concentration events (>10 μg m−3) occurred in the spring, the time of maximum Asian dust transport to the western US. Simulated surface dust concentrations from the Navy Aerosol Analysis and Prediction System (NAAPS) suggested that long-range transport from Asia dominates surface dust concentrations in the western US in the spring, and that, although some long-range transport does occur throughout the year (1–2 μg m−3), locally generated dust plays a larger role in the region in summer and fall. However, NAAPS simulated some anomalously high concentrations (>50 μg m−3) of local dust in the fall and winter months over portions of the western US. Differences between modeled and observed dust concentrations were attributed to overestimation of total observed soil dust concentrations by the assumptions used to convert IMPROVE measurements into PM10 soil concentrations, lack of inhibition of model dust production in snow-covered regions, and lack of seasonal agricultural sources in the model.  相似文献   

13.
The onset of electrical breakdown in dust layers has been studied for hand-deposited dust layers in a parallel plate geometry. It was found that the breakdown was an ordinary electron avalanche process originating in voids within the dust layer and obeying Paschen’s Law. The size of voids where breakdown occurs was in the range of 10 to 20 μm for the layers used. The distribution of particle sizes in a sample Influences its breakdown through changes in the average void dimension where breakdown takes place. Water vapor in the test environment, which affects the electrical conduction mechanism prior to breakdown, lowered the average electric field required to initiate breakdown. Moderate compaction of the sample had little or no effect on its breakdown behavior.  相似文献   

14.
A new real-time dust mass monitor has been developed by combining an automatic isokinetic sampling probe with a tapered element oscillating microbalance (TEOM). Fly ash from a room temperature wind tunnel is sampled through the isokinetic sampler and collected on an astroquartz mat filter in the TEOM detector. The filter is first excited and oscillated at low frequency (about 200 Hz). As the particles deposit on the filter, the mass increase of the filter is reflected in a frequency reduction which yields the collected particle mass directly in real time. The TEOM detector normally has a high mass resolution (10?9 g) and wide dynamic range (1055–1066). It is desensitized for high particle loading applications. Good agreement has been obtained between the mass collected through the isokinetic sampling system and the weight loss of the dust feeder, in real time. The body of information presented in this paper is directed to those concerned with particle emission and control in fossil fuel combustion systems.  相似文献   

15.
Synthetic musks (SMs) have been widely used as fragrance ingredients in personal care and sanitary commodities. Due to their high volatility and particle-binding affinity, the indoor dust is a major reservoir of SMs, and dust ingestion could be an important exposure way to special populations, such as hairdressers. In spite of the known toxicity of SMs, there is no information regarding the occurrence of SMs in barbershop dusts and the exposure of hairdressers through indoor dust ingestion. In the present study, the levels of two nitro musks and five polycyclic musks were measured from indoor dust samples collected from barbershops, and some other indoor dust samples were also collected from dormitories, bathhouses and households for comparison. The concentrations of ∑SMs in barbershop dusts were 10–100 times higher than those from the other three indoor microenvironments. Polycyclic musks accounted for 89.4% of ∑SMs on average in all samples, of which two compounds, HHCB and AHTN jointly dominated 97.9% of polycyclic musks. The levels of HHCB and AHTN varied from 12.2 to 8.39 × 105 and from 13.2 to 3.49 × 105 ng g−1, respectively. The daily intakes (DIs) of ∑SMs through house dust ingestion were estimated using the model of high dust ingestion and worst-case exposure (P95), and the corresponding exposure rates were 2791, 135 and 727 ng d−1 for the hairdressers, general population and toddlers. SMs were also detected in blood samples collected from the hairdressers and normal adults (n = 50 and 10, respectively). There was no significant difference between these two groups. Despite the absence of higher SM concentrations in hairdresser’s blood, we should not overlook the potential occupational health risks due to their high SMs ingestion rate.  相似文献   

16.
Abstract

Many areas in Jordan suffer from elevated levels of coarse particulate matter (PM10). One potentially significant source of the observed PM is the resuspension of road dust in the vicinity of limestone quarries. To obtain data to assess the impact from this source, PM10 road dust resus-pension factors near Abusiiah, a town to the north east of Amman surrounded by many quarries and brick factories, were measured. Measurements included PM10 mass, particle size distributions, wind speed, and wind direction.The results showed that PM10 concentrations could be as high as 600 µg/m3, and most of the airborne PM is in the coarse fraction. Loading trucks play a major role in resus-pending road dust, with an observed PM10 emission rate of >6000 mg/km.  相似文献   

17.
泛比电阻电除尘器收尘性能实验研究   总被引:1,自引:1,他引:0  
泛比电阻电除尘器是一种具有辅助电极和交错平板收尘电极的新型电除尘器.通过对其伏安特性及除尘效率的试验研究,并与传统线板式静电除尘器进行比较,结果表明辅助电极对电晕电流具有明显的抑制作用,在相同的外加电压下,泛比电阻电除尘器对高比电阻锅炉飞灰的收尘效率比普通的线板式电除尘器明显要高.  相似文献   

18.
Quantitative information on the contribution of dust storms to atmospheric PM10 (particulate matter with an aerodynamic diameter ≤10 µm) levels is still lacking, especially in urban environments with close proximity to dust sources. The main objective of this study was to quantify the contribution of dust storms to PM10 concentrations in a desert urban center, the city of Beer-Sheva, Negev, Israel, during the period of 2001–2012. Toward this end, a background value based on the “dust-free” season was used as a threshold value to identify potentially “dust days.” Subsequently, the net contribution of dust storms to PM10 was assessed. During the study period, daily PM10 concentrations ranged from 6 to over 2000 µg/m3. In each year, over 10% of the daily concentrations exceeded the calculated threshold (BVt) of 71 µg/m3. An average daily net contribution of dust to PM10 of 122 µg/m3 was calculated for the entire study period based on this background value. Furthermore, a dust storm intensity parameter (Ai) was used to analyze several storms with very high PM10 contributions (hourly averages of 1000–5197 μg/m3). This analysis revealed that the strongest storms occurred mainly in the last 3 yr of the study. Finally, these findings indicate that this arid urban environment experiences high PM10 levels whose origin lies in both local and regional dust events.

Implications:The findings indicate that over time, the urban arid environment experiences high PM10 levels whose origin lies in local and regional dust events. It was noticed that the strongest storms have occurred mainly in the last 3 yr. It is believed that environmental changes such as global warming and desertification may lead to an increased air pollution and risk exposure to human health.  相似文献   


19.
This paper evaluates the role of Saharan dust advection in the exceeding of the PM10 thresholds in the city of Rome, Italy. To this purpose, a series of observations and model forecasts recorded in the year 2001 are analysed and discussed. Lidar profiles collected over 168 days of the year are employed to both assess the presence and magnitude of Saharan dust layers over the city and to evaluate the depth of the planetary boundary layer. Backtrajectories are used to verify the Saharan origin of the lidar-sounded air masses. Model predictions of the presence of Saharan dust over the area are employed to fill the time gaps between lidar observations. PM10 and carbon monoxide records of both a city background (Villa Ada) and a heavy traffic station (Magna Grecia) are cross-analysed with the dust events record and meteorological data. The analysis shows that: (1) Saharan dust was advected over Rome on about 30% of the days of 2001; (2) mean contribution of Saharan dust transport events to daily PM10 levels was of the order of 20 μg m−3; (3) at the urban background station of Villa Ada, the Saharan contribution caused the surpassing of the maximum number of days in excess of 50 μg m−3 fixed by the current legislation (35 per year). Conversely, at the heavy traffic station of Magna Grecia the Saharan contribution was not determinant at causing the observed large exceeding of that limit, as well as of the maximum yearly average of 40 μg m−3; (4) 25% of the Saharan advection days (of the order of 100/year at Rome) led to a PM10 increase >30 μg m−3, 4% caused an increase >50 μg m−3, thus leading on their own to surpassing the 50 μg m−3 daily limit.  相似文献   

20.
Traffic-generated fugitive dust on gravel roads impairs visibility and deposits on the adjacent environment. Particulate matter smaller than 10 μm in diameter (PM10) is also associated with human health problems. Dust emission strength depends on the composition of granular material, road moisture, relative humidity, local climate (precipitation, wind velocity, etc.), and vehicle characteristics.The objectives of this study were to develop a reliable and rapid mobile methodology to measure dust concentrations on gravel roads, evaluate the precision and repeatability of the methodology and correspondence with the currently used visual assessment technique. Downwind horizontal diffusion was studied to evaluate the risk of exceeding the maximum allowed particulate matter concentration in ambient air near gravel roads according to European Council Directive [European Council Directive 1999/30/EC of 22 April 1999 relating to limit values for sulphur dioxide, nitrogen dioxide and oxides of nitrogen, particulate matter and lead in ambient air. Official Journal of the European Communities. L163/41.].A TSI DustTrak Aerosol Monitor was mounted on an estate car travelling along test sections treated with various dust suppressants. Measured PM10 concentrations were compared to visual assessments performed at the same time. Airborne particles were collected in filters mounted behind the vehicle to compare the whole dust fraction with the PM10 concentration. For measuring the horizontal diffusion, DustTraks were placed at various distances downwind of a dusty road section.The mobile methodology was vehicle and speed dependent but not driver dependent with pre-specified driving behaviours. A high linear correlation between PM10 of different vehicles makes relative measurements of dust concentrations possible. The methodology gives continuous data series, mobility, and easy handling and provides fast, reliable and inexpensive measurements for estimating road conditions to make road maintenance more efficient.Good correlations between measured PM10-values, visually assessed dust generation and dust collected in filters were obtained. PM10 seems to be correlated to the whole dust fraction that impairs visibility on gravel roads.A decay in PM10 concentration as a function of distance from the road was observed. Measured particles principally did not travel further than 45 m from the road. The risk of exceeding the PM10 concentration stated in the EC-directive seems small.  相似文献   