首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A mechanism of rainfall augmentation in the lee of big (~ 5000 MWe) power plants due to washout of liquid water content of cooling tower plumes by raindrops, has been studied by means of a one-dimensional plume model. The relative rainfall increase beneath the plume was estimated for various meteorological conditions and total outputs of cooling tower system. Usually the rainfall increase, doesn't exceed 20–40% and extends not more than 5–7 km from the power plant. In favourable conditions rainfall may however increase even 70 % or more over a large area. In such cases the amount of additionally deposited water may several times exceed the total emission from cooling towers. The total, yearly or seasonal increase of rainfall, which is much smaller due to variability of the wind direction, depends on local climatological conditions.  相似文献   

2.
The incineration of solid waste produces large quantities of bottom and fly ash. Landfilling has been the primary mode of disposal of these waste materials. Shortage in landfill space and the high cost of treatment have, however, prompted the search for alternative uses of these waste materials. This study presents an experimental program that was conducted to determine the engineering properties of incinerator ash mixes for use as construction materials. Incinerator ash mixes were tested as received and around optimum compacted conditions. Compaction curves, shear strength, and permeability values of fly ash, bottom ash, and their various blends were investigated. Bottom ash tends to achieve maximum dry density at much lower water content than does fly ash. The mixes displayed a change in their cohesion and friction angle values when one of the two mix components was altered or as a result of the addition of water. The permeability of bottom ash is quite comparable to that of sand. The permeability of fly ash lies in the range of those values obtained for silts and clays. A 100% bottom ash compacted at the optimum water content has a lower density value and yields a higher friction angle and cohesion values than most construction fills. This would encourage the use of bottom ash as a fill or embankment material because free drainage of water will prevent the buildup of pore water pressures.  相似文献   

3.
Possible effects of climate change on air quality are studied for two urban sites in the UK, London and Glasgow. Hourly meteorological data were obtained from climate simulations for two periods representing the current climate and a plausible late 21st century climate. Of the meteorological quantities relevant to air quality, significant changes were found in temperature, specific humidity, wind speed, wind direction, cloud cover, solar radiation, surface sensible heat flux and precipitation. Using these data, dispersion estimates were made for a variety of single sources and some significant changes in environmental impact were found in the future climate. In addition, estimates for future background concentrations of NOx, NO2, ozone and PM10 upwind of London and Glasgow were made using the meteorological data in a statistical model. These showed falls in NOx and increases in ozone for London, while a fall in NO2 was the largest percentage change for Glasgow. Other changes were small. With these background estimates, annual-average concentrations of NOx, NO2, ozone and PM10 were estimated within the two urban areas. For London, results averaged over a number of sites showed a fall in NOx and a rise in ozone, but only small changes in NO2 and PM10. For Glasgow, the changes in all four chemical species were small. Large-scale background ozone values from a global chemical transport model are also presented. These show a decrease in background ozone due to climate change. To assess the net impact of both large scale and local processes will require models which treat all relevant scales.  相似文献   

4.
Abstract

The incineration of solid waste produces large quantities of bottom and fly ash. Landfilling has been the primary mode of disposal of these waste materials. Shortage in landfill space and the high cost of treatment have, however, prompted the search for alternative uses of these waste materials. This study presents an experimental program that was conducted to determine the engineering properties of incinerator ash mixes for use as construction materials. Incinerator ash mixes were tested as received and around optimum compacted conditions. Compaction curves, shear strength, and permeability values of fly ash, bottom ash, and their various blends were investigated. Bottom ash tends to achieve maximum dry density at much lower water content than does fly ash. The mixes displayed a change in their cohesion and friction angle values when one of the two mix components was altered or as a result of the addition of water. The permeability of bottom ash is quite comparable to that of sand. The permeability of fly ash lies in the range of those values obtained for silts and clays. A 100% bottom ash compacted at the optimum water content has a lower density value and yields a higher friction angle and cohesion values than most construction fills. This would encourage the use of bottom ash as a fill or embankment material because free drainage of water will prevent the buildup of pore water pressures.  相似文献   

5.
Significant dioxin (polychlorinated dibenzo-para-dioxins (PCDDs)/polychlorinated dibenzo-furans (PCDFs)) pollution from a municipal solid waste incinerator was discovered in 1997 in Osaka prefecture/Japan. The cause and mechanism of pollution was identified by a detailed assessment of the environment and incinerator plant. The primary sources of PCDD/PCDF pollution were high dioxin releases from an intermittently operated waste incinerator with PCDD/PCDF emissions of 150 ng-TEQ/Nm3. PCDD/PCDF also accumulated in the wet scrubber system (3,000 μg TEQ/L) by adsorption and water recirculation in the incinerator. Scrubber water was air-cooled with a cooling tower located on the roof of the incinerator. High concentrations of dioxins in the cooling water were released as aerosols into the surrounding and caused heavy soil pollution in the area near the plant. These emissions were considered as the major contamination pathway from the plant. Decontamination and soil remediation in and around the incinerator plant were conducted using a variety of destruction technologies (including incineration, photochemical degradation and GeoMelt technology). Although the soil remediation process was successfully finished in December 2006 about 3 % of the waste still remains. The case demonstrates that releases from incinerators which do not use best available technology or which are not operated according to best environmental practices can contaminate their operators and surrounding land. This significant pollution had a large impact on the Japanese government’s approach toward controlling dioxin pollution. Since this incident, a ministerial conference on dioxins has successfully strengthened control measures.  相似文献   

6.
The performance of a garbage disposal system to solubilize and mineralize food wastes through biological solubilization was evaluated through the examination of the effects of operational conditions like water supply volume, water supply frequency and aeration on the amount of waste solubilized, mineralized and accumulated in the reactor. The biological solubilization process consisted of a solubilization reactor and a circulation tank. Food waste and fresh water were supplied into the solubilization reactor with support media. Wastewater from the solubilization reactor was discharged to the circulation tank and water in the circulation tank was periodically pumped back to the solubilization reactor. In case of the total food waste loading of 16 kg m(3-1) d(-1), little carbon (0-5.7%) accumulated in the reactor as long as the system was kept under aerobic condition through large volume of water supply (higher than 3.5 lh(-1)) or applying aeration in the circulation tank. However, 42% of the loaded carbon accumulated under anaerobic condition in low water supply (less than 1.8 lh(-1)). The rest of the waste was either solubilized or mineralized. The aeration in the circulation tank, therefore, was effective to provide similar solubilization and mineralization as the large volume of water supply. However, frequency of feeding at the large volume of water supply had no significant effect on the amount of waste solubilization and mineralization.  相似文献   

7.

Water is necessary for the survival of life on Earth. A wide range of pollutants has contaminated water resources in the last few decades. The presence of contaminants incredibly different dyes in waste, potable, and surface water is hazardous to environmental and human health. Different types of dyes are the principal contaminants in water that need sudden attention because of their widespread domestic and industrial use. The toxic effects of these dyes and their ability to resist traditional water treatment procedures have inspired the researcher to develop an eco-friendly method that could effectively and efficiently degrade these toxic contaminants. Here, in this review, we explored the effective and economical methods of metal-based nanomaterials photocatalytic degradation for successfully removing dyes from wastewater. This study provides a tool for protecting the environment and human health. In addition, the insights into the transformation of solar energy for photocatalytic reduction of toxic metal ions and photocatalytic degradation of dyes contaminated wastewater will open a gate for water treatment research. The mechanism of photocatalytic degradation and the parameters that affect the photocatalytic activities of various photocatalysts have also been reported.

  相似文献   

8.
The local and regional distribution of pollutants is significantly influenced by weather patterns and variability along with the spatial patterns of emissions. Therefore, climatic changes which affect local meteorological conditions can alter air quality. We use the regional air quality model CHIMERE driven by meteorological fields from regional climate change simulations to investigate changes in summer ozone mixing ratios over Europe under increased greenhouse gas (GHG) forcing. Using three 30-year simulation periods, we find that daily peak ozone amounts as well as average ozone concentrations substantially increase during summer in future climate conditions. This is mostly due to higher temperatures and reduced cloudiness and precipitation over Europe and it leads to a higher number of ozone events exceeding information and warning thresholds. Our results show a pronounced regional variability, with the largest effects of climate change on ozone concentrations occurring over England, Belgium, Germany and France. The temperature-driven increase in biogenic emissions appears to enhance the ozone production and isoprene was identified as the most important chemical factor in the ozone sensitivity. We also find that summer ozone levels in future climate projections are similar to those found during the exceptionally warm and dry European summer of 2003. Our simulations suggest that in future climate conditions summer ozone might pose a much more serious threat to human health, agriculture and natural ecosystems in Europe, so that the effects of climate trends on pollutant amounts should be considered in future emission control measures.  相似文献   

9.
10.
Measurements of natural draft cooling tower plume behavior, as well as meteorological variables, were obtained from aircraft flights near major power plants of the American Electric Power System. Persistence of the visible plume to great distances depends essentially on ambient humidity. Atmospheric stability at plume elevation was also important. Cooling tower-induced fog at ground-level was never observed in any of the tests, and aerodynamic downwash of the visible plume was absent also. The cooling towers did cause modification of natural clouds and they occasionally shadowed some local areas from the sun. Merging of the stack and cooling tower plumes was a common occurrence.  相似文献   

11.
A simple method, in real time, to detect an inversion layer in the lower atmosphere, can be that of monitoring horizontal microwave radiopropagation across the considered area, between two stations linked by radiowaves only during non-standard atmospheric conditions.Experimental results of the first three months of continuous measurements at 3cm, wave-lengths, are given for a path only over sea and for one only flat land.An attempt to find a connection with local meteorological ground data has shown a strong correlation between radio signal reception along super-standard distances and the water vapour pressure for the sea path. In this case, “radio ducting” seems to result from a steep monotonic decaying of the water content of the air.Radio measurements over the flat land path show radio ducting to be an almost nocturnal process. In this case, radiopropagation beyond the horizon detects temperature inversions caused by nocturnal cooling and, therefore, there is no correlation with meteorological ground data.Finally, the frequent presence of radio ducts (time efficiencies greater than 80% have been measured by the authors in certain periods of the year) could also be exploited by telecommunication users for inexpensive transmission, although not in real time, of pre-recorded data.  相似文献   

12.
研究城市生活垃圾在机械炉排炉内焚烧过程,建立了垃圾在炉排炉移动床内燃烧过程中垃圾体积变化、水分蒸发、挥发分析出及燃烧、垃圾颗粒的移动、气-固两相热传递、焦炭燃烧等各个反应阶段的热化学模型,采用一维非稳态模型分别建立了床层内气固两相介质控制方程。通过对炉排上垃圾焚烧过程的数值模拟研究,获得料层中温度分布、料层高度、炉床机械负荷、气相中反应物组分和污染物浓度分布。利用建立的模型对某大型垃圾焚烧炉的燃烧过程进行数值仿真,对燃烧过程、烟气成分进行预测,为垃圾焚烧炉排炉的设计和燃烧控制提供理论依据。  相似文献   

13.
Goal, Scope and Background One of the burning problems of our industrial society is the high consumption of water and the high demand for clean drinking water. Numerous approaches have been taken to reduce water consumption, but in the long run it seems only possible to recycle waste water into high quality water. It seems timely to discuss alternative water remediation technologies that are fit for industrial as well as less developed countries to ensure a high quality of drinking water throughout Europe. Main Features The present paper discusses a range of phytoremediation technologies to be applied in a modular approach to integrate and improve the performance of existing wastewater treatment, especially towards the emerging micro pollutants, i.e. organic chemicals and pharmaceuticals. This topic is of global relevance for the EU. Results Existing technologies for waste water treatment do not sufficiently address increasing pollution situation, especially with the growing use of organic pollutants in the private household and health sector. Although some crude chemical approaches exist, such as advanced oxidation steps, most waste water treatment plants will not be able to adopt them. The same is true for membrane technologies. Discussion Incredible progress has been made during recent years, thus providing us with membranes of longevity and stability and, at the same time, high filtration capacity. However, these systems are expensive and delicate in operation, so that the majority of communities will not be able to afford them. Combinations of different phytoremediation technologies seem to be most promising to solve this burning problem. Conclusions To quantify the occurrence and the distribution of micropollutants, to evaluate their effects, and to prevent them from passing through wastewater collection and treatment systems into rivers, lakes and ground water bodies represents an urgent task for applied environmental sciences in the coming years. Recommendations Public acceptance of green technologies is generally higher than that of industrial processes. The EU should stimulate research to upgrade existing waste water treatment by implementing phytoremediation modules and demonstrating their reliability to the public.  相似文献   

14.
This study quantifies the contribution through energy consumption, to the heat island phenomena and discussed how reductions in energy consumption could mitigate impacts on the urban thermal environment. Very detailed maps of anthropogenic heat in Tokyo were drawn with data from energy statistics and a very detailed digital geographic land use data set including the number of stories of building at each grid point. Animated computer graphics of the annual and diurnal variability in Tokyo's anthropogenic heat were also prepared with the same data sources. These outputs characterize scenarios of anthropogenic heat emission and can be applied to a numerical simulation model of the local climate. The anthropogenic heat flux in central Tokyo exceeded 400 W m−2 in daytime, and the maximum value was 1590 W m−2 in winter. The hot water supply in offices and hotels contributed 51% of this 1590 W m−2. The anthropogenic heat flux from the household sector in the suburbs reached about 30 W m−2 at night. Numerical simulations of urban climate in Tokyo were performed by referring to these maps. A heat island appeared evident in winter because of weakness of the sea breeze from Tokyo Bay. At 8 p.m., several peaks of high-temperature appeared, around Otemachi, Shinjuku and Ikebukuro; the areas with the largest anthropogenic heat fluxes. In summer the shortwave radiation was strong and the influence of anthropogenic heat was relatively small. In winter, on the other hand, the shortwave radiation was weak and the influence of anthropogenic heat was relatively large. The effects of reducing energy consumption, by 50% for hot water supply and 100% for space cooling, on near surface air temperature would be at most −0.5°C.  相似文献   

15.
Microscale sealed vessel pyrolysis (MSSVpy) was used to characterise the hydrophobic (HPO) and colloid (COL) fractions of dissolved organic matter (DOM) from the effluents (EFFs) of two waste water treatment plants (WWTPs) and several primary source waters (SWs). The EFFs showed a large range of anthropogenically sourced organics - including the metabolites of industrial chemicals (e.g., dioxanes, n- and sec-alkyl substituted benzenes and long chain alkyl phenols), pharmaceuticals (e.g., N- and S-heterocycles) and human waste (e.g., S- and N-organics, steranes/sterenes) - as well as high concentrations of alkyl aromatic and N-organic products (e.g., alkyl indoles, carbazoles and β-carbolines) attributed to the treatment biota. Some anthropogenic chemicals are potentially toxic at even trace levels, whilst the N-organics may be precursors for toxic N-disinfection by-products. Much lower concentrations of just a few of the anthropogenic and N-organic products were detected by more traditional flash pyrolysis (Flash-py) of the EFF samples, reflecting the higher sensitivity of MSSVpy to many chemical functionalities. Few of these products were detected in the corresponding MSSVpy analysis of the SWs, but these samples did show relatively high abundances of lignin (e.g., alkylphenols) and carbohydrate (e.g., furans) derived products. Their lower EFF abundances are consistent with efficient removal by the water treatment procedures applied. Conversely, the detection of the anthropogenics in the treated EFFs reflects their general resistance to treatment. Their occurrence in the HPO fractions isolated by XAD resin separation suggests a potential relationship with the structurally stable macromolecular fraction of the DOM.  相似文献   

16.
Static subcritical water extraction (SubWE) along with solid phase extraction (SPE) was used for the analysis of PAHs and pesticides in municipal solid waste compost. Yields obtained for PAHs in certified reference sediment (CRM 104) were acceptable. The extraction method was simple, rapid, used small sample sizes, and no sample drying was required. Analysis of samples was performed by GC/MS and HPLC. Recovery of spiked pesticides was greatest at 110 degrees C for 20 min extraction time. The optimum extraction for PAH analysis was achieved at 150 degrees C for 20 min. Addition of C-18 resin as an "alternate sorbent" upon cooling increased recovery of PAHs but not of pesticides, however, it increased the stability of atrazine and propazine at higher temperatures. Analysis of three municipal compost samples from the Dayton, OH (USA) area showed no pesticides above the detection limit, however, PAH totals for 11 PAHs were 15.97, 14.42, and 20.79 microg g(-1). The totals of six of the seven carcinogenic PAHs, for which remediation goals in the United States is 4.6 microg g(-1), were determined to be 9.89, 6.77, and 13.06 microg g(-1) dry weight. The highest PAH totals were obtained from compost containing sewage sludge.  相似文献   

17.
Waters located at greater depths usually exhibit high mineral content, which necessitates the use of closed systems, i.e. re-injecting them into the formation after recovering the heat. This significantly reduces investment efficiency owing to the need to drill absorption wells and to perform anti-corrosion and anti-clogging procedures. In this paper, possibilities for the efficient utilisation of cooled geothermal waters are considered, particularly with respect to open or mixed geothermal water installations. Where cooled water desalination technologies are used, this allows the water to be demineralised and used to meet local needs (as drinking water and for leisure purposes). The retentate left as a by-product of the process contains valuable ingredients that can be used for balneological and/or leisure purposes. Thus, the technology for desalinating spent geothermal waters with high mineral content allows improved water management on a local scale and makes it possible to minimise the environmental threat resulting from the need to dump these waters into waterways or surface water bodies and/or inject them into the formation. The paper is concerned with Polish geothermal system and provides information about the parameters of Polish geothermal waters.  相似文献   

18.
This paper is a contribution to the understanding of the topoclimatic and environmental geography of the basin where Santiago — one of the most polluted Latin American city – is located. In the first part, land-use change is analysed looking at the climatic transformation caused by the rapid transit from natural semiarid surface to urban areas. In the second part, seasonal weather and daily cycles of slope winds and the available ventilation are described trying to relate those patterns with the spatial distribution of air pollution. A combination of meteorological, geographical and cultural factors explain extreme air pollution events: meteorologically, Santiago is under permanent subsidence inversion layers. Geographically, the city is located in a closed basin surrounded by mountains. Culturally, the urban area has the highest population concentration (40% of the national total), industries (near 70% of the total) and vehicles, which are the main sources of smog. The urban and suburban transport system is based on a large number of buses (diesel) and private cars, both experiencing a rapid growth from the past few years. The city and specially the transport system generates high emissions of pollutant, but the natural semiarid deforested soils and slopes are also important sources. The local wind system can explain the differential spatial distribution on the concentration of air pollutants in the city and its periphery. In winter (rain season) concentrations of particulate matter are higher at the centre and the SW part of the city. The andean piedmont area (E part of the city) shows minimum values, suggesting major ventilation effects of slope and valley winds. Ozone exceeds air quality standards in summer (dry season) at all sites in the centre and periphery. However, the O3-concentrations are higher on preferred residential areas located at the piedmont area (E part of the city), suggesting air pollution transport effects. Currently, there is no consideration of these local climatic features in the process of urban planning.  相似文献   

19.
An episode selection procedure was developed and applied to select sets of days representing characteristic meteorological conditions leading to high ozone episodes over the Swiss Plateau. The selection procedure was applied to data extending from January 1991 through December 1998, and is comprised of two steps: First, days were classified according to observed air quality and meteorological characteristics using classification and regression trees analysis (CART). Second, the CART results were used in conjunction with observed air quality data to identify sets of days characteristic of those leading to elevated ozone. These sets of days were selected to optimise how well a limited number of days represented seasonal air quality, and that formed longer episodes for use in the air quality modelling. CART analysis was performed for three zones of the Swiss Plateau that have different air quality and meteorological characteristics. The results for two zones were used together in the episode selection procedure in order to identify days representative for the whole Plateau. Meteorological analysis for a third zone suggested that it would be strongly impacted by pollutants transported in from outside the country. One thousand and eight hundred optimisation runs were performed to minimise the likelihood that the set of days was a local optimum, increasing the robustness for use in air quality modelling analysis. Fifteen days, grouped in four episodes ranging from 3 to 5 days were selected along with their calculated representativeness (or weight) to recreate a seasonal metric. The variety of local as well as regional meteorological characteristics showed that the episode selection procedure chose days representing a diverse set of meteorological situations which are associated with elevated ozone. This set of episodes can now be used to test air quality strategies.  相似文献   

20.
Analyte concentrations in aqueous leachates from polyethylene tanks filled with five different solid wastes were compared with those in extracts from five laboratory batch procedures. Solid wastes used in the study included: electroplating sludge, electric arc furnace dust, paint Incinerator ash, mine tailings, and municipal refuse incinerator ash. Batch extraction procedures used to extract the solid wastes Included: Monofilled Waste Extraction Procedure (MWEP), U.S. EPA Extraction Procedure (EP), Ham Procedure C (HAM-C), Acetate Buffer Extraction Procedure (ABEP), and Saturated Paste Procedure (PASTE).

Analyte concentrations in leachate from the large columns were reproducible and characteristic of each solid waste. In most Instances, analytes in column leachate reached a peak concentration at a liquld-to-solid ratio of 1:1 followed by a gradual to rapid decrease with continued leaching. Analyte concentrations found in large column leachate were related qualitatively to those found in extracts from the batch procedures which used delonlzed water as the extraction medium (i.e., MWEP, HAM-C, and PASTE). Batch extraction procedures using leaching medium containing acetic acid (I.e., EP) or sodium acetate buffer (i.e., ABEP) generally did not reflect analyte concentrations in leachate from the large columns. These results suggest that batch extraction procedures using acetic acid or acetate buffer are less effective for assessing the teachability of monofilled wastes than extraction methods using deionized water as the extraction fluid.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号