首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A continuous method for the measurement of SO2 in ambient air at trace levels is described. The principle of detection is based on the anodic oxidation of SO2 in a galvanic cell. A differential measuring technique with a cell with two anodes and one cathode is used; background and noise current are low and stable. A feature of the measuring system is that the air sample is passed through a porous anode against a head of electrolyte on the other side of the anode. The minimum values for the time constant and the lower detection limit were 3 seconds and about 3µg/m3, respectively. The selectivity of the method was compared with those of other techniques in field testing. Trace concentrations measured by the galvanic method in the range from 12 to 135 µg/m3 were in good agreement with those of the flame photometric and the West-Gaeke method. With a Pt/Ni2B/graphite anode the mean oxidation efficiency was 94 ± 2% on the basis of 2 faraday/mol of SO2 within the tested concentration range of 50 to 560 µg/m3. During a field test no decrease in the anode activity was observed over a period of ten months. Examples are given for the galvanic detection of other compounds using porous measuring electrodes.  相似文献   

2.
ABSTRACT

The air quality in five Finnish ice arenas with different volumes, ventilation systems, and resurfacer power sources (propane, gasoline, electric) was monitored during a usual training evening and a standardized, simulated ice hockey game. The measurements included continuous recording of carbon monoxide (CO), nitric oxide (NO), and nitrogen dioxide (NO2) concentrations, and sampling and analysis of volatile organic compounds (VOCs). Emissions from the ice resurfacers with combustion engines caused indoor air quality problems in all ice arenas. The highest 1-hour average CO and NO2 concentrations ranged from 20 to 33 mg/m3 (17 to 29 ppm) and 270 to 7440 µg/m3 (0.14 to 3.96 ppm), respectively. The 3-hour total VOC concentrations ranged from 150 to 1200 µg/m3. The highest CO and VOC levels were measured in the arena in which a gasoline-fueled resurfacer was used. The highest NO2 levels were measured in small ice arenas with propane-fueled ice resurfacers and insufficient ventilation.

In these arenas, the indoor NO2 levels were about 100 times the levels measured in ambient outdoor air, and the highest 1-hour concentrations were about 20 times the national and World Health Organization (WHO) health-based air quality guidelines. The air quality was fully acceptable only in the arena with an electric resurfacer. The present study showed that the air quality problems of indoor ice arenas may vary with the fuel type of resurfacer and the volume and ventilation of arena building. It also confirmed that there are severe air quality problems in Finnish ice arenas similar to those previously described in North America.  相似文献   

3.
ABSTRACT

Recent evidence has implicated the fine fraction of particulate as the major contributor to the increase in mortality and morbidity related to particulate ambient levels. We therefore evaluated the impact of daily variation of ambient PM2.5 and other pollutants on the number of daily respiratory-related emergency visits (REVs) to a large pediatric hospital of Santiago, Chile. The study was conducted from February 1995 to August 1996. Four monitoring stations from the network of Santiago provided air pollution data. The PM2.5 24-hr average ranged from 10 to 111 μg/m3 during September to April (warm months) and from 10 to 156 μg/m3 during May to August (cold months). Other contaminants (ozone (O3), nitrogen dioxide (NO2), and sulfur dioxide (SO2)) were, in general, low during the study period. The increase in REVs was significantly related to PM10 and PM2.5 ambient levels, with the relationship between PM2.5 levels and the number of REVs the stronger. During the cold months, an increase of 45 ìg/m3 in the PM2.5 24-hr average was related to a 2.7% increase in the number of REVs (95% CI, 1.1–4.4%) with a two-day lag, and to an increase of 6.7% (95% CI, 1.7–12.0%) in the number of visits for pneumonia with a three-day lag. SO2 and NO2 were also related to REVs. We conclude that urban air pollutant mixture, particularly fine particulates, adversely affect the respiratory health of children residing in Santiago.  相似文献   

4.
Abstract

Particles emitted from gravel processing sites are one contributor to worsening air quality in Taiwan. Major pollution sources at gravel processing sites include gravel and sand piles, unpaved roads, material crushers, and bare ground. This study analyzed fugitive dust emission characteristics at each pollution source using several types of particle samplers, including total suspended particulates (TSP), suspended particulate (PM10), fine suspended particulate (PM2.5), particulate sizer, and dust-fall collectors. Furthermore, silt content and moisture in the gravel were measured to develop particulate emission factors. The results showed that TSP (<100 µm) concentrations at the boundary of gravel sites ranged from 280 to 1290 µg/m3, which clearly exceeds the Taiwan hourly air quality standard of 500 µg/m3. Moreover, PM10 concentrations, ranging from 135 to 550 µg/m3, were also above the daily air quality standard of 125 µg/m3 and approximately 1.2 and 1.5 times the PM2.5 concentrations, ranging from 105 to 470 µg/m3. The size distribution analysis reveals that mass mean diameter and geometric standard deviation ranged from 3.2 to 5.7 µm and from 2.82 to 5.51, respectively. In this study, spraying surfactant was the most effective control strategy to abate windblown dust from unpaved roads, having a control efficiency of approximately 93%, which is significantly higher than using paved road strategies with a control efficiency of approximately 45%. For paved roads, wet suppression provided the best dust control efficiencies ranging from 50 to 83%. Re-vegetation of disturbed ground had dust control efficiencies ranging from 48 to 64%.  相似文献   

5.

Background, aim, and scope

Ten years of public health interventions on industrial emissions to clean air were monitored for the Mediterranean city of Cartagena. During the 1960s, a number of large chemical and non-ferrous metallurgical factories were established that significantly deteriorated the city’s air quality. By the 1970s, the average annual air concentration of sulfur dioxide (SO2) ranged from 200 to 300 µg/m3 (standard conditions units). In 1979, the Spanish government implemented an industrial intervention plan to improve the performance of factories and industrial air pollution surveillance. Unplanned urban development led to residential housing being located adjacent to three major factories. Factory A produced lead, factory B processed zinc from ore concentrates, and factory C produced sulfuric acid and phosphates. This, in combination with the particular abrupt topography and frequent atmospheric thermal inversions, resulted in the worsening of air quality and heightening concern for public health. In 1990, the City Council authorized the immediate intervention at these factories to reduce or shut down production if ambient levels of SO2 or total suspended particles (TSP) exceeded a time-emission threshold in pre-established meteorological contexts. The aim of this research was to assess the appropriateness and effectiveness of the intervention plan implemented from 1992 to 2001 to abate industrial air pollution.

Materials and methods

The maximum daily 1-h ambient air level of SO2, NO2, and TSP pollutants was selected from one of the three urban automatic stations, designed to monitor ambient air quality around industrial emissions sources. The day on which an intervention took place to reduce and/or interrupt industrial production by factory and pollutant was defined as a control day, and the day after an intervention as a post-control day. To assess the short-term intervention effect on air quality, an ecological time series design was applied, using regression analysis in generalized additive models, focusing on day-to-day variations of ambient air pollutants levels. Two indicators were estimated: (a) appropriateness, the ratio between mean levels of the pollutant for control days versus the other days, and (b) effectiveness, the ratio between mean levels of the pollutant for post-control days versus the other days. Ratios in regression analyses were adjusted for trend, seasonality, temperature, humidity and atmospheric pressure, calendar day, and special events as well as the other pollutants.

Results

A total of 702 control days were made on the factories’ industrial production during the 10-year period. Fifteen reductions and five shutdown control days took place at factory A for ambient air SO2. At factory B, more controls were carried out for the SO2 pollutant in the years 1992–1993 and 1997. At factory C, the control days for SO2 decreased from 59 reductions and 14 shutdowns to a minimum from 1995 onwards, whereas the controls on TSP were more frequent, reaching a maximum of 99 reductions and 47 shutdowns in the last year. SO2 ambient air mean levels ranged from 456 to 699 µg/m3 among factories on reduction control days and between 624 and 1,010 µg/m3 on shutdown days. The TSP ambient air mean levels were 428 and 506 µg/m3 on reduction and shutdown days, respectively. For all types of control days and factories, a mean ratio of 104% (95% confidence interval [CI] 88 to 121) in SO2 levels was obtained and a mean ratio of 67% (95% CI 59 to 75) in TSP levels. Post-control days at all factories showed a mean ratio of ?16% (95% CI ?7 to ?24) in SO2 levels and a mean ratio of ?13% (95% CI ?7 to ?19) in TSP levels.

Discussion

Interventions on industrial production based on the urban SO2 and TSP ambient air levels were justified by the high concentrations detected. The best assessment of the interventions’ effectiveness would have been to utilize the ambient air pollutant concentration readings from the entire time of the production shutdowns or reductions; however, the daily hourly maximum turned out to be a useful indicator because of meteorological factors influencing the diurnal concentration profile. A substantial number of interventions were carried out from 1 to 3 am, when vehicular traffic was minimum. On the other hand, atmospheric stability undergoes diurnal cycling in the autumn–winter period due to thermal inversion, which reaches maximum levels around daybreak. Therefore, this increases the ambient air levels and justified the interventions carried out at daybreak in spite of the traffic influence.

Conclusions

All the interventions for SO2 and TSP were carried out when the measured ambient air levels of pollutants were exceeded, which shows the appropriateness of the intervention program. This excess was greater when intervening on SO2 than on the TSP levels. For both ambient air levels of SO2 and TSP, significant drops in air pollution were achieved from all three factories following activity reductions. The production shutdown controls were very effective, because they returned excess levels, higher than in the reduction controls, to everyday mean values.

Recommendations and perspectives

The Cartagena City observational system of intermittent control has proven to effectively reduce industrial emissions’ impact on ambient air quality. This experienced model approach could serve well in highly polluted industrial settings. From a public health perspective, studies are needed to assess that the industrial interventions to control air pollution were related to healthier human populations. Legislation was needed to allow the public administration to take direct actions upon the polluting industries.  相似文献   

6.
Abstract

This paper analyzes the air quality impacts of coal-fired power plants in the northern passageway of the West-East Power Transmission Project in China. A three-layer Lagrangian model called ATMOS, was used to simulate the spatial distribution of incremental sulfur dioxide (SO2) and coarse particulate matter (PM10) concentrations under different emission control scenarios. In the year 2005, the emissions from planned power plants mainly affected the air quality of Shanxi, Shaanxi, the common boundary of Inner Mongolia and Shanxi, and the area around the boundary between Inner Mongolia and Ningxia. In these areas, the annually averaged incremental SO2 and PM10 concentrations exceed 2 and 2.5 µg/m3, respectively. The maximum increases of the annually averaged SO2 and PM10 concentrations are 8.3 and 7.2 µg/m3, respectively, which occur around Hancheng city, near the boundary of the Shaanxi and Shanxi provinces. After integrated control measures are considered, the maximum increases of annually averaged SO2 and PM10 concentrations fall to 4.9 and 4 µg/m3, respectively. In the year 2010, the areas affected by planned power plants are mainly North Shaanxi, North Ningxia, and Northwest Shanxi. The maximum increases of the annually averaged SO2 and PM10 concentrations are, respectively, 6.3 and 5.6 µg/m3, occurring in Northwest Shanxi, which decline to 4.4 and 4.1 µg/m3 after the control measures are implemented. The results showed that the proposed power plants mainly affect the air quality of the region where the power plants are built, with little impact on East China where the electricity will be used. The influences of planned power plants on air quality will be decreased greatly by implementing integrated control measures.  相似文献   

7.
Continued development of personal air pollution monitors is rapidly improving government and research capabilities for data collection. In this study, we tested the feasibility of using GPS-enabled personal exposure monitors to collect personal exposure readings and short-term daily PM2.5 measures at 15 fixed locations throughout a community. The goals were to determine the accuracy of fixed-location monitoring for approximating individual exposures compared to a centralized outdoor air pollution monitor, and to test the utility of two different personal monitors, the RTI MicroPEM V3.2 and TSI SidePak AM510. For personal samples, 24-hr mean PM2.5 concentrations were 6.93 μg/m3 (stderr = 0.15) and 8.47 μg/m3 (stderr = 0.10) for the MicroPEM and SidePak, respectively. Based on time–activity patterns from participant journals, exposures were highest while participants were outdoors (MicroPEM = 7.61 µg/m3, stderr = 1.08, SidePak = 11.85 µg/m3, stderr = 0.83) or in restaurants (MicroPEM = 7.48 µg/m3, stderr = 0.39, SidePak = 24.93 µg/m3, stderr = 0.82), and lowest when participants were exercising indoors (MicroPEM = 4.78 µg/m3, stderr = 0.23, SidePak = 5.63 µg/m3, stderr = 0.08). Mean PM2.5 at the 15 fixed locations, as measured by the SidePak, ranged from 4.71 µg/m3 (stderr = 0.23) to 12.38 µg/m3 (stderr = 0.45). By comparison, mean 24-h PM2.5 measured at the centralized outdoor monitor ranged from 2.7 to 6.7 µg/m3 during the study period. The range of average PM2.5 exposure levels estimated for each participant using the interpolated fixed-location data was 2.83 to 19.26 µg/m3 (mean = 8.3, stderr = 1.4). These estimated levels were compared with average exposure from personal samples. The fixed-location monitoring strategy was useful in identifying high air pollution microclimates throughout the county. For 7 of 10 subjects, the fixed-location monitoring strategy more closely approximated individuals’ 24-hr breathing zone exposures than did the centralized outdoor monitor. Highlights are: Individual PM2.5 exposure levels vary extensively by activity, location and time of day; fixed-location sampling more closely approximated individual exposures than a centralized outdoor monitor; and small, personal exposure monitors provide added utility for individuals, researchers, and public health professionals seeking to more accurately identify air pollution microclimates.

Implications: Personal air pollution monitoring technology is advancing rapidly. Currently, personal monitors are primarily used in research settings, but could they also support government networks of centralized outdoor monitors? In this study, we found differences in performance and practicality for two personal monitors in different monitoring scenarios. We also found that personal monitors used to collect outdoor area samples were effective at finding pollution microclimates, and more closely approximated actual individual exposure than a central monitor. Though more research is needed, there is strong potential that personal exposure monitors can improve existing monitoring networks.  相似文献   

8.
The motorcycle taxi drivers of Bangkok have been heavily exposed to high concentrations of PM10 (particulate matter with an aerodynamic diameter ≤10 μm), and the impact of this on their lungs has been neither documented nor studied. This study examines the association between exposure to PM10 and lung function decline among motorcycle taxi drivers. A cross-sectional study was conducted in Bangkok between two groups: a subject group of motorcycle taxi drivers and control group of enclosed vehicle taxi drivers. The findings of the Thailand Pollution Control Department were used to estimate the annual ambient PM10 concentration levels in the metropolis. Pulmonary functions of motorcycle taxi drivers and enclosed vehicle taxi drivers were measured and compared using the Mann-Whitney test. Multiple linear regression analysis was applied to estimate the effects of PM10 exposure on the lung function of motorcycle taxi drivers. A total of 1283 motorcycle taxi drivers and 600 taxi drivers were investigated. The mean forced expiratory volume in 1 sec/forced vital capacity (FEV1/FVC) of the motorcycle taxi drivers was significantly lower than that of the taxi drivers (P < 0.001). The mean FEV1/FVC of motorcycle taxi drivers exposed to ≥50 µg/m3 PM10 was statistically lower (?2.82%; 95% confidence interval [CI]: ?4.54% to ?1.09%) and the mean % vital capacity (%VC) of those exposed to 40–49.9 µg/m3 PM10 was statistically lower than that of motorcycle taxi drivers exposed to <30 µg/m3 PM10 (?3.33%; 95% CI: ?5.79% to ?0.87%). Motorcycle taxi drivers were directly exposed to air pollution in their working environment. As a result, their lung function might decrease more than that of enclosed vehicle taxi drivers. With the possible exposure to ≥50 µg/m3 PM10, the vehicular emission standards should be vigorously enforced. Further investigation is warranted to clarify the effect of lung dysfunction on the work and lifestyle of motorcycle taxi drivers.

Implications: Motorcycle taxi drivers are directly exposed to air pollution in their work environment; therefore, their lung function might decrease more than that of enclosed vehicle taxi drivers, especially when exposed to ≥50 µg/m3 PM10. World Health Organization (WHO) vehicular emission standards should be recognized and eventually enforced.  相似文献   

9.
Carbonaceous species (organic carbon [OC] and elemental carbon [EC]) and inorganic ions of particulate matter less than 2.5 μm (PM2.5) were measured to investigate the chemical characteristics of long-range-transported (LTP) PM2.5 at Gosan, Jeju Island, in Korea in the spring and fall of 2008–2012 (excluding 2010). On average, the non-sea-salt (nss) sulfate (4.2 µg/m3) was the most dominant species in the spring, followed by OC (2.6 µg/m3), nitrate (2.1 µg/m3), ammonium (1.7 µg/m3), and EC (0.6 µg/m3). In the fall, the nss-sulfate (4.7 µg/m3) was also the most dominant species, followed by OC (4.0 µg/m3), ammonium (1.7 µg/m3), nitrate (1.1 µg/m3), and EC (0.7 µg/m3). Both sulfate and OC were higher in the fall than in the spring, possibly due to more common northwest air masses (i.e., coming from China and Korea polluted areas) and more frequent biomass burnings in the fall. There was no clear difference in the EC between the spring and fall. The correlation between OC and EC was not strong; thus, the OC measured at Gosan was likely transported across a long distance and was not necessarily produced in a manner similar to the EC. Distinct types of LTP events (i.e., sulfate-dominant LTP versus OC-dominant LTP) were observed. In the sulfate-dominant LTP events, air masses directly arrived at Gosan without passing over the Korean Peninsula from the industrial area of China within 48 hr. During these events, the aerosol optical depth (AOD) increased to 1.63. Ionic balance data suggest that the long-range transported aerosols are acidic. In the OC-dominant LTP event, a higher residence time of air masses in Korea was observed (the air masses departing from the mainland of China arrived at the sampling site after passing Korea within 60–80 hr).

Implications:?In Northeast Asia, various natural and anthropogenic sources contribute to the complex chemical components and affect local/regional air quality and climate change. Chemical characteristics of long-range-transported (LTP) PM2.5 were investigated during spring and fall of 2008, 2009, 2011, and 2012. Based on air mass types, sulfate-dominant LTP and OC-dominant LTP were observed. A long-term variation and chemical characteristics of PM2.5 along with air mass and satellite data are required to better understand long-range-transported aerosols.  相似文献   

10.
To estimate plausible health effects associated with peak sulfur dioxide (SO2) levels from three coal-fired power plants in the Baltimore, Maryland, area, air monitoring was conducted between June and September 2013. Historically, the summer months are periods when emissions are highest. Monitoring included a 5-day mobile and a subsequent 61-day stationary monitoring study. In the stationary monitoring study, equipment was set up at four sites where models predicted and mobile monitoring data measured the highest average concentrations of SO2. Continuous monitors recorded ambient concentrations each minute. The 1-min data were used to calculate 5-min and 1-hr moving averages for comparison with concentrations from clinical studies that elicited lung function decrement and respiratory symptoms among asthmatics. Maximum daily 5-min moving average concentrations from the mobile monitoring study ranged from 70 to 84 ppb (183–220 µg/m3), and maximum daily 1-hr moving average concentrations from the mobile monitoring study ranged from 15 to 24 ppb (39–63 µg/m3). Maximum 5-min moving average concentrations from stationary monitoring ranged from 39 to 229 ppb (102–600 µg/m3), and maximum daily 1-hr average concentrations ranged from 15 to 134 ppb (40–351 µg/m3). Estimated exposure concentrations measured in the vicinity of monitors were below the lowest levels that have demonstrated respiratory symptoms in human clinical studies for healthy exercising asthmatics. Based on 5-min and 1-hr monitoring, the exposure levels of SO2 in the vicinity of the C.P. Crane, Brandon Shores, and H.A. Wagner power plants were not likely to elicit respiratory symptoms in healthy asthmatics.

Implications: Mobile and stationary air monitoring for SO2 were conducted to quantify short-term exposure risk, to the surrounding community, from peak emissions of three coal-fired power plants in the Baltimore area. Concentrations were typically low, with only a few 5-min averages higher than levels indicated during clinical trials to induce changes in lung capacity for healthy asthmatics engaged in exercise outdoors.  相似文献   

11.
Abstract

The follow-up of a cohort of adults from 29 European centers of the former European Community Respiratory Health Survey (ECRHS) I (1989–1992) will examine the long-term effects of exposure to ambient air pollution on the incidence, course, and prognosis of respiratory diseases, in particular asthma and decline in lung function. The purpose of this article is to describe the methodology and the European-wide quality control program for the collection of particles with 50% cut-off size of 2.5 µm aerodynamic diameter (PM2.5 ) in the ECRHS II and to present the PM2.5 results from the winter period 2000–2001.

Because PM2.5 is not routinely monitored in Europe, we measured PM2.5 mass concentrations in 21 participating centers to estimate background exposure in these cities. A standardized protocol was developed using identical equipment in each center (U.S. Environmental Protection Agency Well Impactor Ninety-Six [WINS] and PQ167 from BGI, Inc.). Filters were weighed in a single central laboratory. Sampling was conducted for 7 days per month for a year.

Winter mean PM2.5 mass concentrations (November 2000–February 2001) varied substantially, with Iceland reporting the lowest value (5 µg/m3) and northern Italy the highest (69 µg/m3). A standardized procedure appropriate for PM2.5 exposure assessmnt in a multicenter study was developed. We expect ECRHS II to have sufficient variation in exposure to assess long-term effects of air pollution in this cohort. Any bias caused by variation in the characteristics of the chosen monitoring location (e.g., proximity to traffic sources) will be addressed in later analyses. Given the homogenous spatial distribution of PM2.5 , however, concentrations measured near traffic are not expected to differ substantially from those measured at urban background sites.  相似文献   

12.
Exposure to ambient particulate matter (PM) is known as a significant risk factor for mortality and morbidity due to cardiorespiratory causes. Owing to increased interest in assessing personal and community exposures to PM, we evaluated the feasibility of employing a low-cost portable direct-reading instrument for measurement of ambient air PM exposure. A Dylos DC 1700 PM sensor was collocated with a Grimm 11-R in an urban residential area of Houston Texas. The 1-min averages of particle number concentrations for sizes between 0.5 and 2.5 µm (small size) and sizes larger than 2.5 µm (large size) from a DC 1700 were compared with the 1-min averages of PM2.5 (aerodynamic size less than 2.5 µm) and coarse PM (aerodynamic size between 2.5 and 10 µm) concentrations from a Grimm 11-R. We used a linear regression equation to convert DC 1700 number concentrations to mass concentrations, utilizing measurements from the Grimm 11-R. The estimated average DC 1700 PM2.5 concentration (13.2 ± 13.7 µg/m3) was similar to the average measured Grimm 11-R PM2.5 concentration (11.3 ± 15.1 µg/m3). The overall correlation (r2) for PM2.5 between the DC 1700 and Grimm 11-R was 0.778. The estimated average coarse PM concentration from the DC 1700 (5.6 ± 12.1 µg/m3) was also similar to that measured with the Grimm 11-R (4.8 ± 16.5 µg/m3) with an r2 of 0.481. The effects of relative humidity and particle size on the association between the DC 1700 and the Grimm 11-R results were also examined. The calculated PM mass concentrations from the DC 1700 were close to those measured with the Grimm 11-R when relative humidity was less than 60% for both PM2.5 and coarse PM. Particle size distribution was more important for the association of coarse PM between the DC 1700 and Grimm 11-R than it was for PM2.5.

Implications: The performance of a low-cost particulate matter (PM) sensor was evaluated in an urban residential area. Both PM2.5 and coarse PM (PM10-2.5) mass concentrations were estimated using a DC1700 PM sensor. The calculated PM mass concentrations from the number concentrations of DC 1700 were close to those measured with the Grimm 11-R when relative humidity was less than 60% for both PM2.5 and coarse PM. Particle size distribution was more important for the association of coarse PM between the DC 1700 and Grimm 11-R than it was for PM2.5.  相似文献   


13.
PM2.5 (particulate matter with an aerodynamic diameter <2.5 μm) samples were collected in the indoor environments of 15 urban homes and their adjacent outdoor environments in Alexandria, Egypt, during the spring time. Indoor and outdoor carbon dioxide (CO2) levels were also measured concurrently. The results showed that indoor and outdoor PM2.5 concentrations in the 15 sites, with daily averages of 45.5 ± 11.1 and 47.3 ± 12.9 µg/m3, respectively, were significantly higher than the ambient 24-hr PM2.5 standard of 35 µg/m3 recommended by the U.S. Environmental Protection Agency (EPA). The indoor PM2.5 and CO2 levels were correlated with the corresponding outdoor levels, demonstrating that outdoor convection and infiltration could lead to direct transportation indoors. Ventilation rates were also measured in the selected residences and ranged from 1.6 to 4.5 hr?1 with median value of 3.3 hr?1. The indoor/outdoor (I/O) ratios of the monitored homes varied from 0.73 to 1.65 with average value of 0.99 ± 0.26 for PM2.5, whereas those for CO2 ranged from 1.13 to 1.66 with average value of 1.41 ± 0.15. Indoor sources and personal activities, including smoking and cooking, were found to significantly influence indoor levels.

Implications: Few studies on indoor air quality were carried out in Egypt, and the scarce data resulted from such studies do not allow accurate assessment of the current situation to take necessary preventive actions. The current research investigates indoor levels of PM2.5 and CO2 in a number of homes located in the city of Alexandria as well as the potential contribution from both indoor and outdoor sources. The study draws attention of policymakers to the importance of the establishment of national indoor air quality standards to protect human health and control air pollution in different indoor environments.  相似文献   

14.
Abstract

Wildfires and prescribed burns are receiving increasing attention as sources of fine particulate matter (PM2.5). The goal of this research project was to understand the impact of mitigation strategies for residences impacted by scheduled prescribed burns and wildfires. Pairs of residences were solicited to have PM2.5 concentrations monitored inside and outside of their houses during four fires. The effect of using air cleaners on indoor PM2.5 was investigated, as well as the effect of keeping windows closed. Appropriately sized air cleaners were provided to one of each pair of residences; occupants of all of the residences were asked to keep windows shut and minimize opening of exterior doors. Additionally, residents were asked to record all of the activities that may be a source of particulate matter, such as cooking and cleaning. Measurements were made during one prescribed burn and three wildfires during the 2002 fire season. Outdoor 24‐hr average PM2.5 concentrations ranging from 6 to 38 µg/m3 were measured during the fires, compared with levels of 2–5 µg/m3 during background measurements when no fires were burning. During the fires, PM2.5 was <3 µg/m3 inside all of the houses with air cleaners installed. This corresponds with a decrease of 63–88% in homes with the air cleaners operating when compared with homes without air cleaners. In the homes without the air cleaners, measured indoor concentrations were 58–100% of the concentrations measured outdoors.  相似文献   

15.
This study was conducted to derive receptor-specific outdoor exposure concentrations of total suspended particulate (TSP) and respirable (dae ≤ 10 µm) air manganese (air-Mn) for East Liverpool and Marietta (Ohio) in the absence of facility emissions data, but where long-term air measurements were available. Our “site-surface area emissions method” used U.S. Environmental Protection Agency’s (EPA) AERMOD (AMS/EPA Regulatory Model) dispersion model and air measurement data to estimate concentrations for residential receptor sites in the two communities. Modeled concentrations were used to create ratios between receptor points and calibrated using measured data from local air monitoring stations. Estimated outdoor air-Mn concentrations were derived for individual study subjects in both towns. The mean estimated long-term air-Mn exposure levels for total suspended particulate were 0.35 μg/m3 (geometric mean [GM]) and 0.88 μg/m3 (arithmetic mean [AM]) in East Liverpool (range: 0.014–6.32 μg/m3) and 0.17 μg/m3 (GM) and 0.21 μg/m3 (AM) in Marietta (range: 0.03–1.61 μg/m3). Modeled results compared well with averaged ambient air measurements from local air monitoring stations. Exposure to respirable Mn particulate matter (PM10; PM <10 μm) was higher in Marietta residents.

Implications: Few available studies evaluate long-term health outcomes from inhalational manganese (Mn) exposure in residential populations, due in part to challenges in measuring individual exposures. Local long-term air measurements provide the means to calibrate models used in estimating long-term exposures. Furthermore, this combination of modeling and ambient air sampling can be used to derive receptor-specific exposure estimates even in the absence of source emissions data for use in human health outcome studies.  相似文献   

16.
Abstract

In response to community concerns, the air quality impact of imploding a 22-story building in east Baltimore, MD, was studied. Time- and space-resolved concentrations of indoor and outdoor particulate matter (PM) (nominally 0.5–10 µm) were measured using a portable nephelometer at seven and four locations, respectively. PM10 levels varied in time and space; there was no measurable effect observed upwind of the implosion. The downwind peak PM10 levels varied with distance (54,000–589 µg/m3) exceeding pre-implosion levels for sites 100 and 1130 m 3000- and 20-fold, respectively. Estimated outdoor 24-hr integrated mass concentrations varied from 15 to 72 µg/m3. The implosion did not result in the U.S. Environmental Protection Agency (EPA) National Ambient Air Quality Standard (NAAQS) for PM10 being exceeded. X-ray fluorescence analysis indicated that the elemental composition was dominated by crustal elements: calcium (57%), silicon (23%), aluminum (7.6%), and iron (6.1%). Lead was above background but at a low level (0.17 µg/m3). Peak PM10 concentrations were short-lived; most sites returned to background within 15 min. No increase in indoor PM10 was observed even at the most proximate 250 m location. These results demonstrate that a building implosion can have a severe but short-lived impact on community air quality. Effective protection is offered by being indoors or upwind.  相似文献   

17.
Health effects of ambient air pollution were studied in three groups of schoolchildren living in areas (suburban, urban and urban-traffic) with different air pollution levels in Eski?ehir, Turkey. This study involved 1,880 students aged between 9 and 13 years from 16 public primary schools. This two-season study was conducted from January 2008 through March 2009. Symptoms of asthma, rhinitis and eczema were determined by the International Study of Asthma and Allergies in Childhood questionnaire in 2008. Two lung function tests were performed by each child for summer and winter seasons with simultaneous ambient air measurements of ozone (O3), nitrogen dioxide (NO2) and sulfur dioxide (SO2) by passive sampling. Effects of air pollution on impaired lung function and symptoms in schoolchildren were estimated by multivariate logistic regression analyses. Girls with impaired lung function (only for the summer season evaluation) were more observed in suburban and urban areas when compared to urban-traffic area ([odds ratio (OR)?=?1.49; 95 % confidence interval (CI) 1.04–2.14] and [OR?=?1.69 (95 % CI 1.06–2.71)] for suburban vs. urban-traffic and urban vs. urban-traffic, respectively). Significant association between ambient ozone concentrations and impaired lung function (for an increase of 10 μg m?3) was found only for girls for the summer season evaluation [OR?=?1.11 (95 % CI 1.03–1.19)]. No association was found for boys and for the winter season evaluation. No association was found between any of the measured air pollutants and symptoms of current wheeze, current rhinoconjunctivitis and current itchy rash. The results of this study showed that increasing ozone concentrations may cause a sub-acute impairment in lung function of school aged children.  相似文献   

18.
Dhaka, the capital of Bangladesh, is among the most polluted cities in the world. This research evaluates seasonal patterns, day-of-week patterns, spatial gradients, and trends in PM2.5 (<2.5 µm in aerodynamic diameter), PM10 (<10 µm in aerodynamic diameter), and gaseous pollutants concentrations (SO2, NO2, CO, and O3) monitored in Dhaka from 2013 to 2017. It expands on past work by considering multiple monitoring sites and air pollutants. Except for ozone, the average concentrations of these pollutants showed strong seasonal variation, with maximum during winter and minimum during monsoon, with the pollution concentration of PM2.5 and PM10 being roughly five- to sixfold higher during winter versus monsoon. Our comparisons of the pollutant concentrations with Bangladesh NAAQS and U.S. NAAQS limits analysis indicate particulate matter (PM2.5 and PM10) as the air pollutants of greatest concern, as they frequently exceeded the Bangladesh NAAQS and U.S. NAAQS, especially during nonmonsoon time. In contrast, gaseous pollutants reported far fewer exceedances throughout the study period. During the study period, the highest number of exceedances of NAAQS limits in Dhaka City (Darus-Salam site) were found for PM2.5 (72% of total study days), followed by PM10 (40% of total study days), O3 (1.7% of total study days), SO2 (0.38% of total study days), and CO (0.25% of total study days). The trend analyses results showed statistically significant positive slopes over time for SO2 (5.6 ppb yr?1, 95% confidence interval [CI]: 0.7, 10.5) and CO (0.32 ppm yr?1, 95% CI: 0.01, 0.56), which suggest increase in brick kilns operation and high-sulfur diesel use. Though statistically nonsignificant annual decreasing slopes for PM2.5 (?4.6 µg/m3 yr?1, 95% CI: ?12.7, 3.6) and PM10 (?2.7 µg/m3 yr?1, 95% CI: ?7.9, 2.5) were observed during this study period, the PM2.5 concentration is still too high (~ 82.0 µg/m3) and can cause severe impact on human health.

Implications: This study revealed key insights into air quality challenges across Dhaka, Bangladesh, indicating particulate matter (PM) as Dhaka’s most serious air pollutant threat to human health. The results of these analyses indicate that there is a need for immediate further investigations, and action based on those investigations, including the conduct local epidemiological PM exposure-human health effects studies for this city, in order to determine the most public health effective interventions.  相似文献   


19.
The body of the information presented in this paper is of general interest to those concerned with air quality. This paper reports data for ambient atmospheric concentrations of water-soluble fluorides determined in samples of suspended particulate matter collected on glass-fiber filters by the National Air Surveillance Network. Data for over 12,000 samples collected in calendar years 1966, 1967, and 1968 are examined. The purpose of the examination of the data is to give an estimation of current air quality with respect to fluoride content.

The samples are extracted with pure boiling water, and the fluoride concentration of the extracts measured using a fluoride-ion selective electrode. The data engendered are tabulated on an annual basis, and a table is presented summarizing the results. Comparative data will be presented showing the distribution of urban and non-urban stations that exhibit various specified fluoride levels. The results show that the fluoride content in the majority of the samples is below the minimum detectable amount of 0.05 µgF/m3. Conclusions that can be drawn include the observations that: few of the urban samples contain over 1.00 µg/m 3 of fluoride, very few of all samples exceeded 1.00 µ/m3 of fluoride, and no non-urban sample contained over 0.16 µg/m3 of fluoride. It was also concluded that only in rare instances would the fluoride concentrations at the sites sampled be in excess of published standards.  相似文献   

20.
The electric system is experiencing rapid growth in the adoption of a mix of distributed renewable and fossil fuel sources, along with increasing amounts of off-grid generation. New operational regimes may have unforeseen consequences for air quality. A three-dimensional microscale chemical transport model (CTM) driven by an urban wind model was used to assess gaseous air pollutant and particulate matter (PM) impacts within ~10 km of fossil-fueled distributed power generation (DG) facilities during the early afternoon of a typical summer day in Houston, TX. Three types of DG scenarios were considered in the presence of motor vehicle emissions and a realistic urban canopy: (1) a 25-MW natural gas turbine operating at steady state in either simple cycle or combined heating and power (CHP) mode; (2) a 25-MW simple cycle gas turbine undergoing a cold startup with either moderate or enhanced formaldehyde emissions; and (3) a data center generating 10 MW of emergency power with either diesel or natural gas-fired backup generators (BUGs) without pollution controls. Simulations of criteria pollutants (NO2, CO, O3, PM) and the toxic pollutant, formaldehyde (HCHO), were conducted assuming a 2-hr operational time period. In all cases, NOx titration dominated ozone production near the source. The turbine scenarios did not result in ambient concentration enhancements significantly exceeding 1 ppbv for gaseous pollutants or over 1 µg/m3 for PM after 2 hr of emission, assuming realistic plume rise. In the case of the datacenter with diesel BUGs, ambient NO2 concentrations were enhanced by 10–50 ppbv within 2 km downwind of the source, while maximum PM impacts in the immediate vicinity of the datacenter were less than 5 µg/m3.

Implications: Plausible scenarios of distributed fossil generation consistent with the electricity grid’s transformation to a more flexible and modernized system suggest that a substantial amount of deployment would be required to significantly affect air quality on a localized scale. In particular, natural gas turbines typically used in distributed generation may have minor effects. Large banks of diesel backup generators such as those used by data centers, on the other hand, may require pollution controls or conversion to natural gas-fired reciprocal internal combustion engines to decrease nitrogen dioxide pollution.  相似文献   


设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号