首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Abstract

Computational fluid dynamic (CFD) analysis of the thermal flow in the combustion chamber of a solid waste incinerator provides crucial insight into the incinerator’s performance. However, the interrelation of the gas flow with the burning waste has not been adequately treated in many CFD models. A strategy for a combined simulation of the waste combustion and the gas flow in the furnace is introduced here. When coupled with CFD, a model of the waste combustion in the bed provides the inlet conditions for the gas flow field and receives the radiative heat flux onto the bed from the furnace wall and gaseous species. An unsteady one-dimensional bed model was used for the test simulation, in which the moving bed was treated as a packed bed of homogeneous fuel particles. The simulation results show the physical processes of the waste combustion and its interaction with the gas flow for various operational parameters.  相似文献   

2.
Air monitoring by the A.I.S.I. filter sampling device which both preceded and was concurrent with source control of particulates demonstrated air quality improvement over a ten-year period. A difference in improvement from that estimated by the pollution control agency resulted from difference in the measurement parameters.  相似文献   

3.
The TR-l Research Committee of the Air Pollution Control Association conducted a survey during 1969–70 to determine what air pollution research problems require attention. All APCA committees were requested to contribute topics to this survey, especially within their area of activity. Other professional societies were contacted through liaison representatives of APCA. The responses to the survey have been reviewed, categorized, selected, and edited for inclusion in this report. Additional material and concepts have been contributed by members of the TR-l Committee.  相似文献   

4.
The use of multistage, dry, fluidized beds of continuously recycled, coal-based activated carbon appears technically and economically attractive for both adsorption of stack gas So2 and sequential conversion to elemental sulfur. Conceptual design details and economic factors are discussed for the treatment of power plant or oil refinery SO2 effluents with by-product sulfur recovery.  相似文献   

5.
Most air pollution control programs rest on one or more of the following four basic philosophies: emission standards, air quality standards, emission taxes, and cost benefit analysis. Frequently they rest on mixtures or combinations of these four. This paper examines each of the four separately, tries to show why each is different from the others, and compares their advantages and disadvantages.  相似文献   

6.
7.
An urban air pollution incident, like a natural or man-made catastrophe, presents a crisis situation which can only be relieved if adequate contingency plans have been prepared in advance and an effective control organization is in a state of operational readiness to meet the threatened emergency. Although many air pollution incident control plans have been proposed in the past, most have remained in the conceptual or theoretical stages of preparation, because the relative infrequency of serious urban air pollution crises and the disruptive nature of major emission control operations tend to limit the opportunities available for field testing of these plans. In this respect, air pollution incident control planning is analogous to strategic planning for a military operation, where the only completely legitimate test of a strategy is applied on the battlefield. In order to accomplish the transition from conceptual planning to a practical, operational field strategy for air pollution incident control, a program of incident control tests has been initiated in Chicago. These field tests, which use the city as a laboratory for the development of control strategies, are analogous to a series of military war games in which communication systems, command and control organizational structures, personnel roles, surveillance and monitoring equipment, control resources and pollution source controllability are tested under conditions which approximate as closely as possible the situation which prevails during an actual air pollution incident. This paper discusses the evolution of an incident control strategy from an initial, fixed response emission control exercise, through a meteorologically initiated control test to a fairly realistic war game series which is still developing.  相似文献   

8.
9.
Abstract

The destruction of parts per million (ppm) levels of volatile organic compounds in a dry air stream by high–energy electron–beam irradiation has been investigated in a pilot plant at the University of Tennessee Space Institute, Tullahoma, Tennessee. In a series of experiments, dry air contaminated with various VOCs in the concentration range of 50–1000 ppm were treated in the UTSI pilot plant to determine the extent of destruction at various electronbeam dose levels.

The destruction removal efficiency was determined as a function of the electron beam irradiation dose. The results suggest a charge transfer reaction as the major decomposition mechanism. A theoretical foundation of the process, along with a simple first–generation reaction kinetics model, a summary of the results from the pilot plant flow reactor, and a preliminary cost analysis for a fullscale detoxification plant using currently available electronbeam gun technology are presented in this paper.  相似文献   

10.
11.
12.
13.
This paper was one of several presented at the Workshop on Air Pollution Control in Portland, Oregon, on May 6, 1968. The Workshop was sponsored by the Manufacturing Chemists Association and the Chemical Industry Council of the Pacific Northwest in cooperation with the Association of Oregon Industries, Association of Washington Industries, and the Environmental Committee of the Portland Chamber of Commerce. While many of the papers were of localized interest, this paper speaks to anyone designing air pollution control systems.  相似文献   

14.
室内空气污染与控制   总被引:8,自引:0,他引:8  
论述了造成室内空气污染的主要原因,分析了室内空气污染的特点及其危害,并结合房屋建筑过程以及人们日常生活的各个方面,提出了预防及控制室内空气污染的具体方法。  相似文献   

15.
16.
17.
18.
19.
20.
Informative Report No. 7 on the inedible rendering industry is one of a series of survey reports prepared by APCA’ TI-2 Committee on air pollution problems and control methods encountered in the chemical industry today.  相似文献   