首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 781 毫秒
1.
Salthammer T  Mentese S 《Chemosphere》2008,73(8):1351-1356
The level of carbonyl compounds in indoor air is crucial due to possible health effects and the high prevalence of their potential sources. Therefore, selecting a convenient and rapid analytical technique for the reliable detection of carbonyl compound concentrations is important. The acetyl acetone (acac) method is a widely used standard procedure for detecting gaseous formaldehyde. For measuring formaldehyde along with other carbonyl compounds, the DNPH-method is commonly applied. The recommended procedure for measuring volatile organic compounds (VOCs) is sampling on Tenax TA, followed by thermal desorption and GC/MS analysis. In this study, different analytical techniques for the quantification of formaldehyde, pentanal, and hexanal are critically compared. It was found that the acac- and DNPH-method are in very good agreement for formaldehyde. In contrast, the DNPH-method significantly underestimates indoor air concentrations of the higher aldehydes in comparison to sampling on Tenax TA, although both methods are strongly correlated. The reported results are part of the EURIMA-WKI study on levels of indoor air pollutants resulting from construction, building materials and interior decoration.  相似文献   

2.
A new sensitive technique for the quantification of formaldehyde (HCHO) and total aldehydes has been developed in order to monitor these compounds, which are known to be involved in air quality issues and to have health impacts. Our approach is based on a colorimetric method where aldehydes are initially stripped from the air into a scrubbing solution by means of a turning coil sampler tube and then derivatised with 3-methylbenzothiazolinone-2-hydrazone in acid media (pH?=??0.5). Hence, colourless aldehydes are transformed into blue dyes that are detected by UV–visible spectroscopy at 630 nm. Liquid core waveguide LCW Teflon® AF-2400 tube was used as innovative optical cells providing a HCHO detection limit of 4 pptv for 100 cm optical path with a time resolution of 15 min. This instrument showed good correlation with commonly used techniques for aldehydes analysis such as DNPH derivatisation chromatographic techniques with off-line and on-line samplers, and DOAS techniques (with deviation below 6 %) for both indoor and outdoor conditions. This instrument is associated with simplicity and low cost, which is a prerequisite for indoor monitoring.  相似文献   

3.
The emission of formaldehyde is an important factor in the evaluation of the environmental and health effects of wood-based board materials. This article gives a comparison between commonly used European test methods: chamber method [EN 717-1, 2004. Wood-based panels—determination of formaldehyde release—Part 1: formaldehyde emission by the chamber method. European Standard, October 2004], gas analysis method [EN 717-2, 1994. Wood-based panels—determination of formaldehyde release—Part 2: formaldehyde release by the gas analysis method, European Standard, November 1994], flask method [EN 717-3, 1996. Wood-based panels—determination of formaldehyde release—Part 3: formaldehyde release by the flask method, European Standard, March 1996], perforator method [EN 120, 1993. Wood based panels—determination of formaldehyde content—extraction method called perforator method, European Standard, September 1993], Japanese test methods: desiccator methods [JIS A 1460, 2001. Building boards. Determination of formaldehyde emission—desiccator method, Japanese Industrial Standard, March 2001 and JAS MAFF 233, 2001] and small chamber method [JIS A 1901, 2003. Determination of the emission of volatile organic compounds and aldehydes for building products—small chamber method, Japanese Industrial Standard, January 2003], for solid wood, particleboard, plywood and medium density fiberboard.The variations between the results from different methods can partly be explained by differences in test conditions. Factors like edge sealing, conditioning of the sample before the test and test temperature have a large effect on the final emission result. The Japanese limit for F **** of 0.3 mg l−1 (in desiccator) for particleboards was found to be equivalent to 0.04 mg m−3 in the European chamber test and 2.8 mg per 100 g in the perforator test. The variations in inter-laboratory tests are much larger than in intra-laboratory tests; the coefficient of variation is 16% and 6.0% for the chamber method, 25% and 3.5% for the gas analysis method and 15% and 5.2% for the desiccator method.  相似文献   

4.
We developed a diffusive sampling device (DSD-carbonyl) for organic carbonyl compounds (aldehydes and ketones) which is suitable for collection and analysis of low concentration levels. This sampling device is composed of three parts, an exposure part made of a porous polytetrafluoroethylene (PPTFE) tube, an analysis part made of polypropylene (PP) tubing and an absorbent part made of 2,4-dinitrophenylhydrazine (DNPH) coated silica gel (DNPH-silica). Aldehydes and ketones diffuse to the DSD-carbonyl through PPTFE-tube by the mechanism of molecular diffusion and react specifically with DNPH to form a stable DNPH-derivatives. Collection is controlled by moving the absorbent from the exposure part to the analysis part by changing the posture of the DSD-carbonyl. DNPH-derivatives were eluted from an analysis part of DSD-carbonyl with acetonitrile directly and analyzed by high performance liquid chromatography (HPLC). The advantages of the DSD-carbonyl are the following: (1) The DSD-carbonyl can be used in a wide range of concentration of aldehydes and ketones in atmosphere, as the DSD-carbonyl exposure part has a variable diffusion area, (2) DNPH-derivatives are eluted from DNPH-silica without contamination of air. (3) The sampler can be applied to active sampling by connecting it with a pump. The limit of detection (LOD) for concentrations of major aldehydes and ketones ranged from 0.072 to 0.13 ppb, and the limit of quantitation (LOQ) ranged from 0.24 to 0.42 ppb. The coefficient variation (CV) for concentrations of major aldehydes and ketones ranged from 2.5 to 3.0% in laboratory air. The DSD-carbonyl method and active sampling method (US EPA method IP-6A) showed a good correlation (formaldehyde, r2=0.995). The uptake rates for formaldehyde, acetaldehyde, and acetone were estimated as 0.078, 0.062 and 0.079 nmol ppb-1 h-1, respectively. It is possible to estimate atmospheric aldehydes and ketones at parts per billion (ppb), with high sensitivity and precision, by using DSD-carbonyl.  相似文献   

5.
Ambient levels of carbonyls were measured at the University of Mexico campus, Mexico City. Only formaldehyde and acetaldehyde were measured, since aldehydes with higher molecular weight were not detected. The most abundant aldehyde was formaldehyde, with an overall ratio CH3CHO/H2CO of 0.43. Maximum concentrations occurred for formaldehyde at 10:00 h while for acetaldehyde at 8:00 h. Comparing the concentration measured in this work with those in urban areas it was found that the formaldehyde and acetaldehyde levels in Mexico City are among the highest reported in the literature.  相似文献   

6.
Measurements of carbonyl compound concentrations at different sites in the Paris area have been carried out. Interpretation of the results made use of the following data: general meteorological conditions, wind field analysis and type of primary pollutant sources. The principal phenomena observed were: a sharp formaldehyde decrease during rainfall; concentration levels of lower aldehydes in rural sites comparable to those found in the literature; an important variation in the ratio of primary aldehydes to secondary aldehydes depending on meteorological conditions; a significant increase in lower aldehyde concentrations downwind from the urban center despite vertical dispersion of the pollutants.  相似文献   

7.
A comprehensive monitoring campaign to assess aldehydes and BTEX concentrations was performed during 12 months, in the Tijuca district (Rio de Janeiro), an area with commercial activities and a high flux of vehicles. The mean concentrations of formaldehyde and acetaldehyde were 151 and 30 ppb, respectively. The high formaldehyde/acetaldehyde ratio was attributed to extensive use of compressed natural gas (CNG). The number of CNG vehicles in the metropolitan Region of Rio de Janeiro increased from 23000 in January 2001 to 161000 in January 2005. Monitoring data show that, for the same period, methane and formaldehyde concentrations increased while NO(x) and CO levels diminished. Mean concentrations for benzene, toluene, ethylbenzene, m,p-xylene and o-xylene, were 1.1, 4.8, 3.6, 10.4 and 3.0 micro gm(-3), respectively. Benzene and toluene concentrations were lower than the values determined in 1996, for the same location. The levels of ethylbenzene and xylenes determined in this work are similar to values obtained in 1996. This fact may be explained as a consequence of changes in the gasoline composition.  相似文献   

8.
Emissions of carbonyl compounds such as formaldehyde, acetaldehyde, and acrolein are of interest to the scientific and regulatory communities due to their suspected or likely impacts on human health. The present work investigates emissions of carbonyl compounds from nine Class 8 heavy-duty diesel (HDD) tractors and also from nine diesel-powered backup generators (BUGs); the former were chosen because of their ubiquity as an emission source, and the latter because of their proximity to centers of human activity. The HDD tractors were operated on the ARB 4-Mode heavy heavy-duty diesel truck (HHDDT) driving cycle, while the BUGs were operated on the ISO 8178 Type D2 5-mode steady-state cycle and sampled using a mobile emissions laboratory (UCR MEL) equipped with a full-scale dilution tunnel. Samples were analyzed using the SAE930142 (Auto/Oil) method for 11 aldehydes, from formaldehyde to hexanaldehyde, and 2 ketones (acetone and methyl ethyl ketone). Although absolute carbonyl emissions varied widely by BUG, the relative contributions of the different carbonyls were similar (e.g., median: 56% for formaldehyde). A slight increasing trend with engine load was observed for relative formaldehyde contribution, but not for acetaldehyde contribution, for the BUGs. On-road per-mile carbonyl emission factors were a strong function of operating mode of the ARB HHDDT cycle, and found to decrease in the order Creep>Transient>Cruise. This order is qualitatively similar to emission factors for PAHs and n-alkanes determined for the same set of Class 8 diesel tractors in an earlier work. In general, relative carbonyl contributions for the HDD tractors were similar to those for BUGs (e.g., median: 54% for formaldehyde). These results indicate that while engine operating mode and application appear to exert a strong influence on the total absolute mass emission rate of the carbonyls measured, they do not appear to exert as strong an influence on the relative mass emission rates of individual carbonyls.  相似文献   

9.
Oxidation of benzene, toluene, ethylbenzene, and xylenes (BTEX) in air, of significance due to, for example, the potential for O3 formation, is believed to be initiated by OH attack on the ring (addition) or on the alkyl side chain (H abstraction). A series of ring-breaking reactions follows, with major products predicted to be alpha-dicarbonyls, simple aldehydes, and organic acids. To test this prediction, ambient air mixing ratios of aldehydes (formaldehyde, acetaldehyde, benzaldehyde, glyoxal, and pyruvaldehyde), along with some supporting BTEX data, were measured at an urban site in Las Vegas, NV. Samples were collected on sorbents and determined by chromatographic methods; mixing ratios were compared to ambient levels of CO, O3, and NOx. A meteorological analysis (temperature, wind speed, and wind direction) was also included. Statistically significant relationships were noted among the BTEX hydrocarbons (HCs) and among the photochemically derived species (e.g., O3, NO2, and some of the aldehydes), although there was seasonal variation. The observations are consistent with a common primary source (i.e., vehicular exhaust or fuel evaporation) for the BTEX compounds and a common secondary source (e.g., OH attack) for glyoxal and pyruvaldehyde.  相似文献   

10.
Atmospheric levels of formaldehyde and acetaldehyde as well as their diurnal and seasonal variations were investigated from 1994 to 1997 in downtown Rome during sunny and wind calm days. Hourly concentrations of formaldehyde ranged from 8 to 28 ppbV in summer and 7 to 17 ppbv in winter; acetaldehyde concentrations varied correspondingly within the 3–18 and 2–7 ppbv intervals. Percentages of both aldehydes photochemically produced were estimated through a simple relationship based upon the comparison of individual ratios of formaldehyde and acetaldehyde to toluene in ambient air and automobile emission. Photochemical production was found to weigh upon atmospheric levels for 80–90% in summer days. It dropped below 35% in the winter period, when direct emission from traffic largely predominated. Photochemical summer source was more efficient for acetaldehyde than for formaldehyde, especially in the early morning. The importance of formaldehyde as the major source of hydroxyl radicals in Rome was also assessed.  相似文献   

11.
Measurements of carbonyls in a 13-story building   总被引:1,自引:0,他引:1  
BACKGROUND, AIM AND SCOPE: Formaldehyde and acetaldehyde are emitted by many mobile and stationary sources and secondary aldehydes are intermediates in the photo-oxidation of organic compounds in the atmosphere. These aldehydes are emitted indoors by many materials such as furniture, carpets, heating and cooling systems, an by smoking. Carbonyls, mainly formaldehyde and acetaldehyde, have been studied because of their adverse health effects. In addition, formaldehyde is a suspected carcinogen. Therefore, the concentrations of formaldehyde and acetaldehyde were determined to assess the inhalation exposure doses to carbonyls for people who work in a 13-story building and in order to evaluate the cancer hazard. METHODS: Carbonyl compounds in indoor and outdoor air were measured at a 13-story building located in Mexico City. The mezzanine, fifth and tenth floors, and the third level-parking garage were selected for sampling. Samples were collected in two sampling periods, the first from April 20 to 29, 1998 and the second from December 1 to 20, 1998. Carbonyls were sampled by means of DNHP-coated cartridges at a flow rate of 1 l min(-1) from 9:00 to 19:00 hours, during 2-hour time intervals and analyzed by HPLC with hours, during 2-hour time intervals and analyzed by HPLC with UV/VIS detection. RESULTS: Mean carbonyl concentrations were highest in the 3rd level-parking garage, with the formaldehyde concentration being the highest ranging from 108 to 418 microg m(-3). In working areas, the highest carbonyl arithmetic mean concentrations (AM) were observed on the 5th floor. Acetone and formaldehyde concentrations were highest in April ranging from 161 to 348 microg m(-3) (AM = 226) and from 157 to 270 microg m(-3) (AM = 221), respectively. Propionaldehyde and butyraldehyde were present in smaller concentrations ranging from 2 to 25 and 1 to 28 microg m(-3), respectively, considering all the samples. Mean indoor/outdoor ratios of carbonyls ranged from 1.8 to 9.6. A reduction of inhalation exposure doses of 41% and 45% was observed in the fifth floor air after the air conditioning systems had been repaired. Formaldehyde and acetaldehyde concentrations were higher in smoking environments. CONCLUSION: Indoor carbonyl concentrations were significantly greater than outdoor concentrations. Tobacco smoke seems to be the main indoor source of formaldehyde. After the air conditioning system was maintained and repaired (as was recommended), an important reduction in the emission of formaldehyde and acetaldehyde was achieved on all floors, except for the 3rd level parking garage, thereby reducing the inhalation exposure doses. RECOMMENDATION: The results obtained in this research demonstrated that maintenance of air conditioning systems must be carried out regularly in order to avoid possible adverse effects on health. Additionally, it is mandatory that isolated smoking areas, with air extraction systems, be installed in every public building.  相似文献   

12.
The emission of volatile organic compounds (VOC) from air filters of HVAC systems was to be evaluated. In a first study carbonyl compounds (14 aldehydes and two ketones) were measured by reacting them with 2,4-dinitrophenylhydrazine (DNPH). Analysis was done by HPLC and UV detection. In laboratory experiments pieces of used and unused HVAC filters were incubated in test chambers. Filters to be investigated were taken from a filter bank of a large HVAC system in the centre of Berlin. First results show that – among those compounds – formaldehyde and acetone were found in higher concentrations in the test chambers filled with used filters in comparison to those with unused filters. Parallel field measurements were carried out at the prefilter and main filter banks of the two HVAC systems. Here measurements were carried out simultaneously before and after the filters to investigate whether those aldehydes or ketones arise from the filter material on site. Formaldehyde and acetone significantly increased in concentration after the filters of one HVAC system. In parallel experiments microorganisms were proved to be able to survive on air filters. Therefore, a possible source of formaldehyde and acetone might be microbes.  相似文献   

13.
《Chemosphere》1987,16(1):99-107
In determining the atmospheric concentration of various components in a complex mixture of organic compounds, substantial problems are often encountered in connection with sampling and analysis. A strategy based on limited sampling of a few compounds, together with a mathematical model (monitor), is proposed as a practical solution to these problems. In this paper such a simplified procedure for monitoring occupational exposure to chain-saw exhaust is reported. The procedure is based on personal monitoring of formaldehyde, benzaldehyde and carbon monoxide and on a mathematical model calculated from emission data. Exposure to hydrocarbons, including benzene, other aldehydes, nitrogen oxides, alkyllead, lead, scavengers and polycyclic aromatic hydrocarbons may be calculated from this monitor with acceptable precision. The use of the monitor greatly simplifies an evaluation of occupational exposure to chain-saw exhaust during logging and it can also be used in emission studies.  相似文献   

14.
Volatile aldehydes are produced during degradation of paper-based materials. This may result in their accumulation in archival and library repositories. However, no systematic study has been performed so far. In the frame of this study, passive sampling was carried out at ten locations in four libraries and archives. Despite the very variable sampling locations, no major differences were found, although air-filtered repositories were found to have lower concentrations while a non-ventilated newspaper repository exhibited the highest concentrations of volatile aldehydes (formaldehyde, acetaldehyde, furfural and hexanal). Five employees in one institution were also provided with personal passive samplers to investigate employees’ exposure to volatile aldehydes. All values were lower than the presently valid exposure limits.The concentration of volatile aldehydes, acetic acid, and volatile organic compounds (VOCs) in general was also compared with that of outdoor-generated pollutants. It was evident that inside the repository and particularly inside archival boxes, the concentration of VOCs and acetic acid was much higher than the concentration of outdoor-generated pollutants, which are otherwise more routinely studied in connection with heritage materials. This indicates that further work on the pro-degradative effect of VOCs on heritage materials is necessary and that monitoring of VOCs in heritage institutions should become more widespread.  相似文献   

15.
静态顶空气相色谱法测定工业废水中的甲醛和苯酚   总被引:7,自引:0,他引:7  
建立了静态顶空取样,气相色谱直接分析水产中甲醛和苯酚的方法。该方法有良好的重现性,甲醛、苯酚连续监测定6次的相对标准偏差分别为1.9%和4.7%,甲醛、苯酚的检测限分别为0.50mg/mL和0.30mg/mL,方法简便,快速,基底干扰小,适用于工业废水中甲醛和苯酚的同时,快速测定。  相似文献   

16.
单波  陈杰  肖岩 《环境工程学报》2013,7(2):649-656
胶合竹材GluBam的甲醛释放情况是现代竹结构住宅环保性的一个重要方面,也是竹结构住宅推广中最受关注的指标之一。采用1 m3气候箱对温度、相对湿度和封边情况与GluBam的甲醛释放量和释放速率的相关关系进行了测试,并以一阶单衰减模型为基础提出了GluBam的甲醛释放分析模型。测试和分析结果表明:GluBam板材在各模拟条件下甲醛浓度峰值均小于规范要求;初始甲醛释放量E0和衰减率常数k可以用来评价GluBam的甲醛释放特征;GluBam的醛释放量和释放速率随环境温度和湿度增加而显著增大,且温度因素的影响更大;封边处理可以有效降低GluBam板材的甲醛释放量。  相似文献   

17.
It is important to understand the effects of emission controls on concentrations of ozone, fine particulate matter (PM2.5), and hazardous air pollutants (HAPs) simultaneously, to evaluate the full range of health, ecosystem, and economic effects. Until recently, the capability to simultaneously evaluate interrelated atmospheric pollutants ("one atmosphere" analysis) was unavailable to air quality managers. In this work, we use an air quality model to examine the potential effect of three emission reductions on concentrations of ozone, PM2.5, and four important HAPs (formaldehyde, acetaldehyde, acrolein, and benzene) over a domain centered on Philadelphia for 12-day episodes in July and January 2001. Although NO(x) controls are predicted to benefit PM2.5 concentrations and sometimes benefit ozone, they have only a small effect on formaldehyde, slightly increase acetaldehyde and acrolein, and have no effect on benzene in the July episode. Concentrations of all pollutants except benzene increase slightly with NO(x) controls in the January simulation. Volatile organic compound controls alone are found to have a small effect on ozone and PM2.5, a less than linear effect on decreasing aldehydes, and an approximately linear effect on acrolein and benzene in summer, but a slightly larger than linear effect on aldehydes and acrolein in winter. These simulations indicate the difficulty in assessing how toxic air pollutants might respond to emission reductions aimed at decreasing criteria pollutants such as ozone and PM2.5.  相似文献   

18.
Formaldehyde, acetaldehyde, acetone, propanal, butanal, 2-butenal, 3-methylbutanal, hexanal, benzaldehyde, 2-methylbenzaldehyde, and 2,5-dimethylbenzaldehyde were measured during six spring days at downtown Santiago de Chile. Measurements were performed 24h/day and averaged over three hour periods. The averages of the maxima (ppbv) were, formaldehyde: 3.9+/-1.4; butanal: 3.3+/-3.4; acetaldehyde: 3.0+/-0.9; acetone: 2.4+/-1.0; 2-butenal: 0.56+/-0.52; propanal: 0.46+/-0.21; benzaldehyde: 0.34+/-0.3; 3-butanal: 0.11+/-0.05; hexanal: 0.11+/-0.08; 2-methylbenzaldehyde: 0.08+/-0.05; 2,5-dimethylbenzaldehyde: 0.05+/-0.03. Aliphatic aldehydes (C1-C3) are strongly correlated among them and weakly with primary (toluene) and secondary (ozone plus nitrogen dioxide or PAN) pollutants. In particular, the correlation between acetaldehyde and propanal values remains even if diurnal and nocturnal data are considered separately, indicating similar sources. All these aldehydes present maxima values in the morning (9-12h) and minima at night (0-3h). The best correlation is observed when butanal and 2-butenal data are considered (r=0.99, butanal/2-butenal=6.2). These compounds present maxima values during the 3-6h period, with minima values in the 0-3h period. These data imply a strong pre-dawn emission. Other aldehydes show different daily profiles, suggesting unrelated origins. Formaldehyde is the aldehyde whose concentration values best correlate with the levels of oxidants. The contribution of primary emissions and photochemical processes to formaldehyde concentrations were estimated by using a multiple regression. This treatment indicates that (32+/-16)% of measured values arise from direct emissions, while (79+/-23)% is attributable to secondary formation.  相似文献   

19.
ABSTRACT

A large chamber test method for measuring indoor air emissions from office equipment was developed, evaluated, and revised based on the initial testing of four dry-process photocopiers. Because all chambers may not necessarily produce similar results (e.g., due to differences in sink effects, temperature and humidity control, air exchange, pollutant monitoring, and measurement biases), a preliminary four-laboratory evaluation of the revised test method was conducted. To minimize variability, the evaluation used a single dry-process photocopier that was shipped to each of the four laboratories along with supplies (i.e., toner and paper).

The results of this preliminary four-laboratory evaluation demonstrate that the test method was used successfully in the different chambers to measure emissions from dry-process photocopiers. Differences in chamber design and construction appeared to have had minimal effect on the results for the volatile organic compounds (VOCs). Perhaps more important than the chamber itself is the sample analysis as identified by duplicate samples that were analyzed by a different laboratory. Percent relative standard deviation (%RSD) was used to provide a simplistic view of interlaboratory precision for this evaluation. Excluding problems with suspected analytical bias observed from one of the laboratories, the precision was excellent for the VOCs with RSDs of less than 10% in most cases. Less precision was observed among the laboratories for aldehydes/ketones (RSD of 23.2% for formaldehyde). The precision for ozone emission rates among three of the laboratories was excellent (RSD of 7.9%), but emission rates measured at the fourth laboratory were much higher.  相似文献   

20.
A compression ignition engine is used for the study of the fuel (one reference and one hydrotreated) and the fuel/air equivalence ratio influence on the exhaust emissions of specific pollutants. Under the experimental conditions used, seven hydrocarbons, nine aldehydes and three organic acids are detected in the exhaust gas. No alcohols are detected under these conditions, indicating that these compounds are emitted only if they (or probably other oxygenated compounds) are introduced in the fuel. Fuel hydrotreatment decreases most of the exhaust pollutants, the four toxics and also the quantity of the ozone that could be formed from the exhaust gas. It also changes the composition of exhaust gas: it increases the proportion of methane, benzene, formaldehyde, acetaldehyde, acroleine, and propionic acid, while it decreases the proportion of all other pollutants detected. Fuel/air equivalence ratio also decreases most of the exhaust emissions, the emission of the total toxics and the quantity of the ozone that could be formed. It also changes the proportion of each pollutant in exhaust gas: the percentages of methane, benzene, acetone and acetic acid increase, while those of the other pollutants detected decrease. The majority of the specific pollutants detected corresponds to organic acids, followed by hydrocarbons and aldehydes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号