首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
通过动态法测试水吸收型空气净化器A和活性炭过滤吸附型净化器B对甲醛的去除性能,探索更为合理的方法以评价空气净化器对气态污染物的去除性能.对净化器A去除甲醛的短期测试结果表明,净化器对甲醛浓度为0.3、0.5、0.8和1 mg/m3的连续空气流均有明显的净化效果,对甲醛的去除速率在0.91~2.78 mg/h之间.对净化...  相似文献   

2.
A survey of key indoor air quality (IAQ) parameters and resident health was carried out in 72 apartments within a single low-income senior housing building in Phoenix, Arizona. Air sampling was carried out simultaneously with a questionnaire on personal habits and general health of residents. Mean PM10 concentrations are 66±16, 58±13, and 24±3 μg/m3 and mean PM2.5 concentrations are 62±16, 53±13, and 20±2 μg/m3 for the living room, kitchen, and outdoor balcony, respectively. Median PM10 concentrations are 17, 18 and 17 μg/m3 and median PM2.5 concentrations are 13, 14, and 13 μg/m3, respectively. The initial results indicate that increased indoor particle concentrations coincide with residents who report smoking cigarettes. Indoor formaldehyde concentrations revealed median levels of 36.9, 38.8, and 4.3 ppb in the living room, kitchen, and balcony, respectively. Results show that 36% of living room samples and 44% of kitchen samples exceeded the Health Canada REL for chronic exposure to formaldehyde (40 ppb). Associations between occupants’ behavior, self-reported health conditions, and IAQ are evaluated.
Implications:This study provides a characterization of indoor air quality (IAQ) of subsidized apartments for seniors in Phoenix, Arizona. It is important for policy makers to understand the environments in which low-income seniors live, as they are vulnerable to the health impacts from poor IAQ. Formaldehyde concentrations were found to exceed the Health Canada 8-hr reference exposure level (REL) for up to 44% of indoor samples. Particulate matter exposure was governed by resident behavior (i.e., smoking). Associations between occupants’ behavior, IAQ, and self-reported health conditions are evaluated. This work can provide a foundation for subsequent remediation of IAQ conditions.  相似文献   

3.
This study was designed to determine the effect of source combinations on formaldehyde levels under whole-house conditions. Evaluations were conducted on particleboard (applied as subflooring) and hardwood plywood panelling (applied as a wall covering) both singly and in combination, and on urea-formaldehyde foam insulation and particleboard. Formaldehyde source combination/interaction evaluations revealed several different outcomes, including no augmentation of formaldehyde levels, a slight augmentation (30-50%) and complete addivity. Additivity was observed for regular and low emission grade particleboard and hardwood plywood combinations and for urea-formaldehyde foam insulation and particleboard subflooring. In contrast, controlled chamber studies employing samples of the same wood materials revealed no additive effects. Results of these studies raise questions about the reliability of using laboratory evaluations alone to predict formaldehyde levels under real-world residential conditions.  相似文献   

4.
A kinetic model for a cycling adsorbent/photocatalyst combination for formaldehyde removal in indoor air (Chin et al. J. Catalysis 2006, 237, 29-37) was previously developed in our lab, demonstrating agreement with lab-scale batch operation data of other researchers (Shiraishi et al. Chem. Engineer. Sci. 2003, 58, 929-934). Model parameters evaluated included adsorption equilibrium and rate constants for the adsorbent (activated carbon) honeycomb rotor, and catalytic rate constant for pseudo-first-order formaldehyde destruction in the titanium dioxide photoreactor. This paper explores design consequences for this novel system. In particular, the batch parameter values are used to model both adsorbent and photocatalyst behavior for continuous operation in typical residential home challenges. Design variables, including realistic make-up air fraction, adsorbent honeycomb rotation speed, and formaldehyde source emission rate, are considered to evaluate the ability of the system to achieve World Health Organization pollutant guidelines. In all circumstances, the size of the required rotating adsorbent bed and photoreactor for single-stage operation and the resultant formaldehyde concentration in the home are calculated. The ability of how well such a system might be accommodated within the typical dimensions of commercial ventilation ducts is also considered.  相似文献   

5.
以集中空调中处理室内可挥发性有机物(VOCs)为应用背景,搭建了试验台.实验研究了真空紫外灯(主波长254 nm,185 nm)降解甲醛的影响因素以及产生O3的情况.研究表明,在产生的O3浓度低于室内空气质量标准(0.16mg/m3)的情况下,真空紫外灯也能够高效地降解空气中低浓度甲醛(<1 mg/m3);甲醛降解率与反应器空气流速及甲醛初始浓度成反比;降解速率与甲醛初始浓度成正比,与反应器空气的流速成反比;绝对湿度对真空紫外灯降解甲醛有一定的影响;反应器空间大小对甲醛降解影响比较显著.应用于集中空调系统净化室内空气中VOCs,取得了很好的效果.  相似文献   

6.
Salthammer T  Mentese S 《Chemosphere》2008,73(8):1351-1356
The level of carbonyl compounds in indoor air is crucial due to possible health effects and the high prevalence of their potential sources. Therefore, selecting a convenient and rapid analytical technique for the reliable detection of carbonyl compound concentrations is important. The acetyl acetone (acac) method is a widely used standard procedure for detecting gaseous formaldehyde. For measuring formaldehyde along with other carbonyl compounds, the DNPH-method is commonly applied. The recommended procedure for measuring volatile organic compounds (VOCs) is sampling on Tenax TA, followed by thermal desorption and GC/MS analysis. In this study, different analytical techniques for the quantification of formaldehyde, pentanal, and hexanal are critically compared. It was found that the acac- and DNPH-method are in very good agreement for formaldehyde. In contrast, the DNPH-method significantly underestimates indoor air concentrations of the higher aldehydes in comparison to sampling on Tenax TA, although both methods are strongly correlated. The reported results are part of the EURIMA-WKI study on levels of indoor air pollutants resulting from construction, building materials and interior decoration.  相似文献   

7.
Abstract

A kinetic model for a cycling adsorbent/photocatalyst combination for formaldehyde removal in indoor air (Chin et al. J. Catalysis 2006, 237, 29-37) was previously developed in our lab, demonstrating agreement with lab-scale batch operation data of other researchers (Shiraishi et al. Chem. Engineer. Sci. 2003, 58, 929-934). Model parameters evaluated included adsorption equilibrium and rate constants for the adsorbent (activated carbon) honeycomb rotor, and catalytic rate constant for pseudo-first-order formaldehyde destruction in the titanium dioxide photoreactor. This paper explores design consequences for this novel system. In particular, the batch parameter values are used to model both adsorbent and photocatalyst behavior for continuous operation in typical residential home challenges. Design variables, including realistic make-up air fraction, adsorbent honeycomb rotation speed, and formaldehyde source emission rate, are considered to evaluate the ability of the system to achieve World Health Organization pollutant guidelines. In all circumstances, the size of the required rotating adsorbent bed and photoreactor for single-stage operation and the resultant formaldehyde concentration in the home are calculated. The ability of how well such a system might be accommodated within the typical dimensions of commercial ventilation ducts is also considered.  相似文献   

8.
This study was designed to determine the effectiveness of spider plants (Clorophytum elatum var. vittatium) as a botanical air purification measure for formaldehyde under dynamic laboratory chamber conditions. Significant reductions in chamber formaldehyde levels were observed when spider plants were placed in experimental chambers. However, highest reductions occurred when spider plants were defoliated. Observed reductions in formaldehyde levels appeared to have been associated with soil medium factors and a source moisture storage phenomenon associated with the use of particleboard as a formaldehyde source inside the chambers. The results of this study do not support the conclusions of previous studies which suggest that botanical air purification using only plant leaves is an effective means of reducing residential formaldehyde levels.  相似文献   

9.
环境测试舱自吸附甲醛重释放规律与影响因素研究   总被引:2,自引:1,他引:1  
广泛用于板材污染物释放量测试、空气净化产品净化效果测试等实验中的环境测试舱,往往由于其内壁黏附性杂质而对目标测试物产生不可忽视的自吸附作用,自吸附污染物将作为二次释放源出现重释放,研究目标测试物的自吸附消耗量及重释放规律,探索有效控制措施,有利于对环境测试舱实验应用及室内污染控制提出指导性实际意义。分别选取0.2%甲醛溶液、大芯板作为同一自制玻璃环境测试舱2期实验(I期、Ⅱ期)的不同甲醛释放源,通过近90 d追踪测试,经不同释放源、不同控制条件下舱内壁自吸附甲醛的多次重释放实验,结合非线性拟合分析方法,总结出舱内壁自吸附甲醛重释放甲醛浓度变化符合一阶递增指数函数:y=A1×exp(-x/t1)+y0,(A1<0、t1>0)。曲线参数y0值可用于评价实验条件下测试舱内自吸附甲醛残余量;y0值与环境舱舱体材质、环境温湿度、舱外甲醛浓度及空气交换手段有关,而与释放源及其释放平衡浓度高低无明显关系。大开舱门短时间抽气式空气交换对舱内自吸附甲醛残余有适度清除效果,使y0值降低,同时有利于再次平衡状态的快速建立;而长时间的无动力空气交换,或者自来水洗及去离子水洗等处理手段对舱内壁自吸附甲醛残余无明显清除作用。  相似文献   

10.
This paper describes a laboratory project to assess the accuracy of emission and indoor air quality models to be used in predicting formaldehyde (HCHO) concentrations in residences due to pressed-wood products made with urea-formaldehyde bonding resins. The products tested were partlcleboard underlayment, hardwood- plywood paneling and medium-density fiberboard (mdf). The products were initially characterized in chambers by measuring their formaldehyde surface emission rates over a range of formaldehyde concentrations, air exchange rates and two combinations of temperature and relative humidity (23° C and 5 0% RH; 26°C and 60% RH). They were then installed in a two-room prototype house in three different combinations (underlayment flooring only; underlayment flooring and paneling; and underlayment flooring, paneling, and mdf). The equilibrium formaldehyde concentrations were monitored as a function of air exchange rate. Particleboard underlayment and mdf, but not paneling, behaved as the emission model predicted over a large concentration range, under both sets of temperature and relative humidity. Good agreement was also obtained between measured formaldehyde concentrations and those predicted by a mass-balance indoor air quality model.  相似文献   

11.
BACKGROUND, AIM AND SCOPE: All across Europe, people live and work in indoor environments. On average, people spend around 90% of their time indoors (homes, workplaces, cars and public transport means, etc.) and are exposed to a complex mixture of pollutants at concentration levels that are often several times higher than outdoors. These pollutants are emitted by different sources indoors and outdoors and include volatile organic compounds (VOCs), carbonyls (aldehydes and ketones) and other chemical substances often adsorbed on particles. Moreover, legal obligations opposed by legislations, such as the European Union's General Product Safety Directive (GPSD) and Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH), increasingly require detailed understanding of where and how chemical substances are used throughout their life-cycle and require better characterisation of their emissions and exposure. This information is essential to be able to control emissions from sources aiming at a reduction of adverse health effects. Scientifically sound human risk assessment procedures based on qualitative and quantitative human exposure information allows a better characterisation of population exposures to chemical substances. In this context, the current paper compares inhalation exposures to three health-based EU priority substances, i.e. benzene, formaldehyde and acetaldehyde. MATERIALS AND METHODS: Distributions of urban population inhalation exposures, indoor and outdoor concentrations were created on the basis of measured AIRMEX data in 12 European cities and compared to results from existing European population exposure studies published within the scientific literature. By pooling all EU city personal exposure, indoor and outdoor concentration means, representative EU city cumulative frequency distributions were created. Population exposures were modelled with a microenvironment model using the time spent and concentrations in four microenvironments, i.e. indoors at home and at work, outdoors at work and in transit, as input parameters. Pooled EU city inhalation exposures were compared to modelled population exposures. The contributions of these microenvironments to the total daily inhalation exposure of formaldehyde, benzene and acetaldehyde were estimated. Inhalation exposures were compared to the EU annual ambient benzene air quality guideline (5 microg/m3-to be met by 2010) and the recommended (based on the INDEX project) 30-min average formaldehyde limit value (30 microg/m3). RESULTS: Indoor inhalation exposure contributions are much higher compared to the outdoor or in-transit microenvironment contributions, accounting for almost 99% in the case of formaldehyde. The highest in-transit exposure contribution was found for benzene; 29.4% of the total inhalation exposure contribution. Comparing the pooled AIRMEX EU city inhalation exposures with the modelled exposures, benzene, formaldehyde and acetaldehyde exposures are 5.1, 17.3 and 11.8 microg/m3 vs. 5.1, 20.1 and 10.2 microg/m3, respectively. Together with the fact that a dominating fraction of time is spent indoors (>90%), the total inhalation exposure is mostly driven by the time spent indoors. DISCUSSION: The approach used in this paper faced three challenges concerning exposure and time-activity data, comparability and scarce or missing in-transit data inducing careful interpretation of the results. The results obtained by AIRMEX underline that many European urban populations are still exposed to elevated levels of benzene and formaldehyde in the inhaled air. It is still likely that the annual ambient benzene air quality guideline of 5 microg/m3 in the EU and recommended formaldehyde 30-min average limit value of 30 microg/m3 are exceeded by a substantial part of populations living in urban areas. Considering multimedia and multi-pathway exposure to acetaldehyde, the biggest exposure contribution was found to be related to dietary behaviour rather than to inhalation. CONCLUSIONS: In the present study, inhalation exposures of urban populations were assessed on the basis of novel and existing exposure data. The indoor residential microenvironment contributed most to the total daily urban population inhalation exposure. The results presented in this paper suggest that a significant part of the populations living in European cities exceed the annual ambient benzene air quality guideline of 5 microg/m3 in the EU and recommended (INDEX project) formaldehyde 30-min average limit value of 30 microg/m3. RECOMMENDATIONS AND PERSPECTIVES: To reduce exposures and consequent health effects, adequate measures must be taken to diminish emissions from sources such as materials and products that especially emit benzene and formaldehyde in indoor air. In parallel, measures can be taken aiming at reducing the outdoor pollution contribution indoors. Besides emission reduction, mechanisms to effectively monitor and manage the indoor air quality should be established. These mechanisms could be developed by setting up appropriate EU indoor air guidelines.  相似文献   

12.
Personal 48-hr exposures to formaldehyde and acetaldehyde of 15 randomly selected participants were measured during the summer/autumn of 1997 using Sep-Pak DNPH-Silica cartridges as a part of the EXPOLIS study in Helsinki, Finland. In addition to personal exposures, simultaneous measurements of microenvironmental concentrations were conducted at each participant's residence (indoor and outdoor) and workplace. Mean personal exposure levels were 21.4 ppb for formaldehyde and 7.9 ppb for acetaldehyde. Personal exposures were systematically lower than indoor residential concentrations for both compounds, and ambient air concentrations were lower than both indoor residential concentrations and personal exposure levels. Mean workplace concentrations of both compounds were lower than mean indoor residential concentrations. Correlation between personal exposures and indoor residential concentrations was statistically significant for both compounds. This indicated that indoor residential concentrations of formaldehyde and acetaldehyde are a better estimate of personal exposures than are concentrations in ambient air. In addition, a time-weighted exposure model did not improve the estimation of personal exposures above that obtained using indoor residential concentrations as a surrogate for personal exposures. Correlation between formaldehyde and acetaldehyde was statistically significant in outdoor microenvironments, suggesting that both compounds have similar sources and sinks in ambient urban air.  相似文献   

13.
汽车内微环境空气污染的初步探究   总被引:2,自引:1,他引:1  
为了研究车内的污染水平,在2004-04-10至2004-06-20对车内空气进行了采样和分析.对车龄在2年内的91种型号轿车的车内微环境进行了静态检测,有效检测车辆共计802辆,同时对比检测20辆2002年以前出厂的旧车.检测项目包括甲醛、苯、甲苯、二甲苯和CO等.参照国家室内空气质量标准,新车中甲苯浓度超标率达82%,苯和甲醛浓度的超标率分别为75%和24%.在被检测车辆中,甲醛、苯、甲苯和二甲苯浓度均是新车比旧车高,只有CO浓度是旧车比新车高.初步分析判断苯系物主要来源于车内的胶粘剂,甲醛来自于车椅座套和座垫等,CO来源于发动机排放残留.  相似文献   

14.
Abstract

Tuberculosis (TB) is a public health problem that may pose substantial risks to health care workers and others. TB infection occurs by inhalation of airborne bacteria emitted by persons with active disease. We experimentally evaluated the effectiveness of in-room air filtration systems, specifically portable air filters (PAFs) and ceiling-mounted air filters (CMAFs), in conjunction with dilution ventilation, for controlling TB exposure in high-risk settings. For each experiment, a test aerosol was continuously generated and released into a full-sized room. With the in-room air filter and room ventilation system operating, time-averaged airborne particle concentrations were measured at several points. The effectiveness of in-room air filtration plus ventilation was determined by comparing particle concentrations with and without device operation. The four PAFs and three CMAFs we evaluated reduced room-average particle concentrations, typically by 30% to 90%, relative to a baseline scenario with two air-changes per hour of ventilation (outside air) only. Increasing the rate of air flow recirculating through the filter and/or air flow from the ventilation did not always increase effectiveness. Concentrations were generally higher near the emission source than elsewhere in the room. Both the air flow configuration of the filter and its placement within the room were important, influencing room air flow patterns and the spatial distribution of concentrations. Air filters containing efficient, but non-high efficiency particulate air (HEPA) filter media were as effective as air filters containing HEPA filter media.  相似文献   

15.
为了对市售被动式室内空气净化产品的净化效果有深刻具体的认识,选择销售份额较大的4种甲醛清除剂进行实验舱测试。结果表明:(1)甲醛清除剂对甲醛的净化过程均随时间呈对数衰减,可见甲醛浓度越高,甲醛清除剂对甲醛的净化速率越快。(2)不同的甲醛清除剂的净化速率都有一定差异,即使24h净化率均在90%以上的甲醛清除剂,净化速率也不同,净化率达到90%以上所需要的实际时间可相差数倍。(3)《室内空气净化功能涂覆材料净化性能》(JCT 1074—2008)中对甲醛清除剂根据其对污染物24h的净化率进行了分级,消费者可据此对净化产品的优劣有初步判断。而净化速率和饱和净化量则可在消费者购买甲醛清除剂时起到更具体和明确的指导作用,并可在消费者具体使用时,根据饱和净化量,对甲醛清除剂用量和甲醛清除剂持续作用时间有初步的判断。  相似文献   

16.
鉴于室内空气甲醛污染的危害,使用市售的"家丁"牌甲醛消除剂,对其去除甲醛性能进行了测试研究.研究结果表明,甲醛消除剂可以快速、有效地消除室内空气中的甲醛,又可以减少室内装修材料中游离甲醛的释放,是治理室内空气甲醛污染的有效手段之一.  相似文献   

17.
A study was conducted to evaluate five techniques for determining ambient formaldehyde concentrations. One technique used a spectroscopic determination, and the other four techniques used derivatization followed by fluorometric analysis or high-performance liquid chromatography with detection by u.v. absorption. Formaldehyde was generated by two techniques. In the first technique, zero air was bubbled through a solution of aqueous formaldehyde to produce gas-phase formaldehyde. Various compounds serving as possible interferences were added singly or in combination to these air mixtures. In the second technique, formaldehyde was generated as a product from controlled irradiations of hydrocarbons and nitrogen oxides in a smog chamber operated in a dynamic mode. The study was conducted as a blind intercomparison with no knowledge by the participants of the HCHO concentrations or the interferences added.The data from each of the techniques were compared against mean values in each sampling period. For formaldehyde in zero air, average deviations for each of the techniques ranged between 15 and 30%. At a formaldehyde concentration of 10 ppb, each technique showed no evidence for interferences by O3 (190 ppbv), NO2 (300 ppbv), SO2 (20 ppbv), and H2O2 (7 ppbv). The agreement for formaldehyde concentrations measured for the photochemical mixtures was similar to that of the mixtures in zero air.Ambient measurements were also performed on three evenings and for one 36-h period. Ambient formaldehyde concentrations ranged from 1 to 10 ppbv. Ambient H2O2 measurements were also performed. A strong correlation in the diurnal concentration profile for formaldehyde and H2O2 was observed over the 36-h period.  相似文献   

18.
Urea-formaldehyde resin bonded partlcleboard, medium density fiberboard and plywood paneling are used as flooring, wall paneling, for cabinet work and in furniture, and are present In almost every office, home and public building. If large quantities of these products are used In poorly ventilated spaces, high manufacturing quality control is necessary to avoid problems of latent formaldehyde release. Indoor air formaldehyde concentrations depend on the nature of the product, the product surface to air volume (loading) factor, temperature, humidity, age and product emission rates. Standard test methods are now available for measuring product emission rates that make It possible to predict the performance of UF-bonded pressed wood materials If use conditions and environmental parameters are known. Recent modifications In adhesive and board manufacturing parameters have made It possible to reduce formaldehyde emission significantly, and UF-bonded wood products are now capable of meeting indoor air quality standard levels of 0.1 ppm under almost all customary loading conditions.  相似文献   

19.
以大孔径SiO2为载体,通过钛酸丁酯溶液的浸渍、原位水解以及高温煅烧制备出大尺寸、大孔径的TiO2/SiO2光催化剂。利用自制空气净化装置对室内甲醛的清除进行研究,分别考察了TiO2的百分含量、紫外光光强、温度、湿度和空气流量等不同条件下TiO2/SiO2光催化剂对除去甲醛效率的影响。结果表明,反应温度从10~50℃依次升高,去除率逐渐下降。在相对湿度为50%,TiO2负载率为55.6%,流量为8 m3/h时,甲醛的最佳除去率达96.5%;经过7周时间的考察,发现TiO2/SiO2光催化剂的催化活性没有明显的下降。  相似文献   

20.
Atmospheric levels of formaldehyde and acetaldehyde as well as their diurnal and seasonal variations were investigated from 1994 to 1997 in downtown Rome during sunny and wind calm days. Hourly concentrations of formaldehyde ranged from 8 to 28 ppbV in summer and 7 to 17 ppbv in winter; acetaldehyde concentrations varied correspondingly within the 3–18 and 2–7 ppbv intervals. Percentages of both aldehydes photochemically produced were estimated through a simple relationship based upon the comparison of individual ratios of formaldehyde and acetaldehyde to toluene in ambient air and automobile emission. Photochemical production was found to weigh upon atmospheric levels for 80–90% in summer days. It dropped below 35% in the winter period, when direct emission from traffic largely predominated. Photochemical summer source was more efficient for acetaldehyde than for formaldehyde, especially in the early morning. The importance of formaldehyde as the major source of hydroxyl radicals in Rome was also assessed.  相似文献   