首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The object of this program was to study particle collection efficiency in venturi scrubbers in order to account for the effects of particle size and wettability, venturi size, and fluid flow rates. The body of information is directed to those interested in the prediction of particle collection efficiency in venturi scrubbers.  相似文献   

2.
Knowledge of the distribution of airborne particulate matter into size fractions has become an increasing area of focus when examining the effects of air pollution. While total number and mass concentrations may play an important role in exposure and risk assessment analyses, often an understanding of the particle size distributions provides more information on the type of atmospheric processes resulting in the distributions. The modality of the particle size distribution is one such aspect that has been associated with the aerosol formation mechanisms. The aim of this work is to provide a detailed analysis of the modal characteristics of a large number of particle size spectra collected over a period of three years for a range of ambient aerosol types. Measurements of over 6000 size distributions in the size range 0.016–30 μm were made using a scanning mobility particle sizer and an aerodynamic particle sizer for various ambient aerosols including: traffic influenced, urban, vegetation burning influenced, marine, modified background and suburban. Advanced data analytical procedures were adopted to combine the distributions from the two instruments for the calculation of the volume size distributions to allow clear interpretation of the modal characteristics. It was determined that, while in most cases there is a distinct nuclei mode in the number size distribution, this does not translate to a nuclei mode in the volume size distribution. Furthermore, while many of the number size distributions were different for each aerosol studied, the volume distributions were similar. This finding has serious implications for the setting of mass-based air quality standards.  相似文献   

3.

Investors and other stakeholders are starting to pay attention to firms’ carbon emissions and carbon disclosure. This study investigated the effects of voluntary carbon disclosure information and carbon emissions on firm value from listed companies in the Shanghai and Shenzhen 300 (CSI 300) Index. We also apply the Probit model to predict the probability of voluntary carbon disclosure information. The results indicate that the increase in carbon emissions has a negative impact on firm value. The action that companies select to disclose carbon emissions has a positive impact on firm value. The effect of leverage ratio on VCDI is increasing year by year. What is more, the probability of the average size firm carbon disclosure was 30.73% in 2020. Company management needs to pay attention to the risks caused by carbon emissions and ensure the quality of carbon disclosure information, especially the authenticity and reliability of the information.

  相似文献   

4.
Rhizoremediation is a significant form of bioremediation for polycyclic aromatic hydrocarbons (PAHs). This study examined the role of molecular structure in determining the rhizosphere effect on PAHs dissipation. Effect size in meta-analysis was employed as activity dataset for building quantitative structure-activity relationship (QSAR) models and accumulative effect sizes of 16 PAHs were used for validation of these models. Based on the genetic algorithm combined with partial least square regression, models for comprehensive dataset, Poaceae dataset, and Fabaceae dataset were built. The results showed that information indices, calculated as information content of molecules based on the calculation of equivalence classes from the molecular graph, were the most important molecular structural indices for QSAR models of rhizosphere effect on PAHs dissipation. The QSAR model, based on the molecular structure indices and effect size, has potential to be used in studying and predicting the rhizosphere effect of PAHs dissipation.  相似文献   

5.
The body of information presented in this paper is directed to those individuals concerned with the measurement of the size distribution of particulate matter in air. The light scattering instrument described herein is characterized by the fact that it can accurately size particles almost independently of their index of refraction. The basic concept involves the simultaneous measurement of the intensity of light scattered by a single particle at two small scattering angles. The ratio of the two intensities is directly related io ine size of ihe pariicle, and for scattering angles of 5° and 10° the effective range of the instrument is 0.2 to 4 μm. The air flows through the optical system at such a rate that approximately 25 μs are required to determine the size of each particle, and concentrations as high as 104 particles/cc can be measured without dilution and without serious coincidence effects. By employing a multichannel analyzer as the data storage and readout device it is possible to detect changes in particulate size distribution within a few seconds. Calibration of the instrument has been performed using polystyrene latex spheres and materials having a wide range of index of refraction and shape including carbon black, iron oxide and spores.  相似文献   

6.
A single-particle scintillation counter-analyser mounted in a light aircraft has been used to obtain information on the Na and K content of the particulates in the atmosphere of Sydney, Australia. A spatial resolution of 1 km is obtained along a 250-km flight path. Total mass loadings and loadings as a function of particle size for Na and K agree with published data for filter samples collected on the ground. Na/K ratios for individual plumes indicate soil dust and combustion are the principal contributors to urban haze detected by this method. The large sea-salt contribution is readily identified and significant sources of non-marine Na exist, particularly in the smaller size ranges. The results suggest that sea-salt contribution to the Na measured in coastal city aerosols may be overestimated.  相似文献   

7.
The body of information presented in this paper is directed to investigators using inertial samplers for precise and accurate studies of respirable aerosols. The conventions commonly used for aerodynamic size for aerosol particles are discussed including the definition popularized by the "Task Group on Lung Dynamics" of the ICRP, and the "Lovelace" definition. To emphasize the distinction, the Task Group definition (unit density sphere equivalent) is called the aerodynamic equivalent diameter, Dae, and the Lovelace definition (characteristic expression based upon viscous resistance) is called the aerodynamic resistance diameter, Dar. The implications and efficacy of these conventions are related to procedures for calibration of cascade impactors, cyclones, and spiral centrifuges. The calibration of a spiral centrifuge at different altitudes is used as an example of the potential problems associated with the use of the different conventions for describing aerodynamic size. The aerodynamic resistance diameter is recommended for calibration of inertial samplers to be used to collect aerosols in the respirable size range.  相似文献   

8.

Goal, scope, and background  

Many studies have focused on measuring fine and course particulate matter (PM) in urban and rural sites around the world. The aim of this research is to gain information on the size distribution of particles. The physical characteristics of PM in the urban air of Istanbul were determined.  相似文献   

9.
We have used Raman spectroscopy to characterize a variety of carbon-containing particulate matter, including samples collected in ambient urban atmospheres. Based on the Raman spectra of known, commercial particles, we derive a simple empirical model that reflects their microchemistry and microphysics. This model gives information on the crystal size and morphology of the graphitic component, which correlates with the known characteristics of the commercial samples. We derive similar information about the graphitic component of the ambient particles, and suggest that this method might be used to characterize ambient particles systematically in the future.  相似文献   

10.
We describe a new experimental methodology based on the contemporary use of two-stage continuous streaker samplers and optical particle counters. This is a complementary approach to size-segregated particulate matter (PM) sampling, and it is able to give information on the elemental size distribution and to assess the contribution of major PM source to size bins. PM samples in the fine and coarse fraction of PM10 have been collected by a two-stage streaker sampler and analyzed by particle-induced X-ray emission (PIXE) to obtain elemental concentration time series with hourly resolution. PM sources and profiles were singled out by positive matrix factorization (PMF). A multi-linear regression of size-segregated number of particles versus the sources, resolved by PMF, made possible the apportionment of size-segregated particles number in a fast and direct way. Results obtained in three sampling sites, located in different urban districts are discussed.  相似文献   

11.
The levels reported in diverse publications of byproducts of cigarette combustion (acrolein, aldehydes, aromatic hydrocarbons, carbon monoxide, nicotine, nitrogen oxides, nitrosamines, particulates, and others for which scattered information is available as HCN, ketones, nitriles) are summarized in tabular form. Summaries also include information on test conditions such as ventilation, size and types of premises, monitoring conditions, number of smokers, and rate of smoking. Current methodology emerging from a review of a wide variety of measuring practices is critically evaluated and discussed. Major findings are reviewed. In conclusion, the presently available data are useful for gaining a reasonably accurate perspective of the amount of combustion products contributed by cigarette smoking under different conditions, even though serious methodological problems persist.  相似文献   

12.
The use of organisms to monitor contamination allows the access to information that cannot be acquired by chemical methods. Limnoperna fortunei, mussel frequently found in Río de la Plata estuary, fulfils the requirements to be used as a biomonitoring organism. In this work we report that a polypeptide of 22 kDa of molecular weight (LF22) is induced when L. fortunei is exposed to Cd (II), Cu(II) and Hg(II) sublethal levels. To characterize LF22, mussels were sampled from a non-polluted region and whole soft tissue was homogenized, with and without previous exposure to 100 microg/L of Cd(II). The cytosolic proteins were evaluated by mono and bidimensional SDS-PAGE, and size exclusion chromatography. All the methods showed that LF22 triples its concentration in presence of Cd(II). Purification of LF22 was achieved by fractioned precipitation, salting-out, ionic exchange and size exclusion chromatography. We conclude that LF22 is a useful biomarker of heavy metal exposure.  相似文献   

13.
The emphasis on participate control from industrial processes has been shifted recently towards fine particulates, having diameters less than 3 microns. There exists an urgent need for more scientific information of fine particle characterization.1,2 Coal and oil fired power plants are among the largest anthropogenic point sources of particulate matter.3 Limited knowledge is available on particle size distribution and trace metal composition in power plant emissions.4-7 The morphological properties of particle emissions have been largely neglected. In this report we present some information on particle characteristics for an oil-fired and coal-fired power plant.  相似文献   

14.

An analytical methodology was developed to characterize the colloidal distribution of trace elements of interest in environmental waters sampled in a same site and enables the different colloidal distributions from waters to be compared. The purpose was to provide consistent information related to the origin and nature of colloids responsible for the transport of trace element(s). The work was motivated by the observed enhanced mobility of uranium in soil. The colloidal size continuum was investigated by a multi-technique approach involving asymmetric flow field-flow fractionation (AF4) coupled with ultraviolet spectroscopy (UV), multi angle light scattering (MALS), and atomic mass spectrometry (ICPMS). To take into consideration the size and shape variability specific to each sample, the size distributions were established from the gyration radii measured from MALS, also considering the size information from standard nanospheres fractionated by AF4. A new parameter called “shape index” was proposed. It expresses the difference in hydrodynamic behavior between analytes and spherical particles taken as reference. Under AF4 diffusion conditions, it can be considered as an evaluator of the deviation from the sphericity of the fractionated analytes. AF4-UV-MALS-ICPMS enabled the dimensional and chemical characteristics of the colloidal size continuum to be obtained. As a “proof of concept”, the developed methodology was applied at a field scale, in a reference study site. In order to have a “dynamic understanding”, the investigation was based on the joint characterization of colloids from surface waters and soil leachates from static and dynamic processes. In the water samples of the study site, the continuum of gyration radius ranged from a few nanometers up to 200 nm. Colloids containing iron, aluminum, and organic carbon were involved in the uranium transport in the soil column and surface waters. The colloidal uranium concentration in the surface water increased from the upstream location (approximately 13 ng (U) L?1) to the downstream location (approximately 60 ng (U) L?1).

  相似文献   

15.
The chemical composition of marine aerosols as a function of their size is an important parameter for the evaluation of their impact on the global climate system. In this work we model fine particle organic matter emitted by sea spray processes and its influence on the aerosol chemical properties at the global scale using the off-line global Chemistry-Transport Model TM5. TM5 is coupled to a microphysical aerosol dynamics model providing size resolved information on particle masses and numbers. The mass of the emitted sea spray particles is partitioned between water insoluble organic matter (WIOM) and sea salt components in the accumulation mode using a function that relates the emitted organic fraction to the surface ocean chlorophyll-a concentrations. The global emission in the sub-micron size range of organic matter by sea spray process is 8.2 Tg yr?1, compared to 24 Tg fine yr?1 sea-salt emissions. When the marine sources are included, the concentrations of modelled primary particulate organic matter (POM) increase mainly over the oceans. The model predictions of WIOM and sea salt are evaluated against measurements carried out at Mace Head (Northern Hemisphere) and Amsterdam Island (Southern Hemisphere), showing that in clean marine conditions WIOM marine emissions contribute significantly to POM values.  相似文献   

16.
Using one- and two-dimensional homogeneous simulations, this paper addresses challenges associated with sensitivity analysis and parameter estimation for virus transport simulated using sorptive-reactive processes. Head, flow, and conservative- and virus-transport observations are considered. The paper examines the use of (1) observed-value weighting, (2) breakthrough-curve temporal moment observations, and (3) the significance of changes in the transport time-step size. The results suggest that (1) sensitivities using observed-value weighting are more susceptible to numerical solution variability, (2) temporal moments of the breakthrough curve are a more robust measure of sensitivity than individual conservative-transport observations, and (3) the transport-simulation time step size is more important than the inactivation rate in solution and about as important as at least two other parameters, reflecting the ease with which results can be influenced by numerical issues. The approach presented allows more accurate evaluation of the information provided by observations for estimation of parameters and generally improves the potential for reasonable parameter-estimation results.  相似文献   

17.
A technique is presented that can be used to estimate the changes in physical structure in a natural biofilter packing medium, such as compost, over time. The technique applies information from tracer studies, grain size distribution, and pressure drop analysis to a model that estimates the number of channels, average channel diameter, number of particles, and specific surface area of the medium. Important operational factors, such as moisture content, pressure drop, and sulfate accumulation also were evaluated both in a conventionally operated biofilter and in one operated with periodic compost mixing. In the conventionally operated laboratory-scale compost biofilter, hydrogen sulfide (H2S) removal efficiency decreased from 100% to approximately 90% over 206 days of operation. In a similar system, operated with compost mixing, the H2S removal efficiency was maintained near 100%. Variations in media moisture conditions and specific surface area can explain the results observed in this study. Under conventional operation, drying near the inlet disintegrated the compost particles, producing a large number of particles and flow channels and increasing the specific surface area. At the top of the column, where moisture was added, particle size increased and specific surface area decreased. In the column with media mixing, moisture content, particle size, and specific surface area remained homogeneous.  相似文献   

18.
The body of information presented in this paper is directed towards the scientist or engineer who measures and interprets the physical characteristics of ambient air. This paper interprets measurements made with the Minnesota Aerosol Analyzing System (MAAS) in Denver, near Denver, and near Ft. Collins, Colo., and examines the measurements in the light of what has been learned from several thousand size distributions measured in the other parts of the United States. The origin and physical change of atmospheric particulates is examined through interpretation of modes occurring in the size distributions. The mode coined “AHken Nuclei Range” mode is a measure of aerosol generation, while aged aerosols show up in the “Accumulation Range” mode. Windblown dusts, sea sprays, and mechanically produced particles such as fly ash generate a “Coarse Particle Range” mode. The air environment is categorized into several types of background and urban aerosols whose physical characteristics are described by a limited number of parameters. These categories are exemplified and discussed.  相似文献   

19.
《Environmental Forensics》2002,3(3-4):349-355
Assessment of environmental damage following accidental oil spills requires reliable oil identification methods. Results from hydrocarbon analyses of environmental samples are often difficult to interpret, because of the changes in oil composition (or weathering) that follows release into the environment, and because of confounding by hydrocarbons from other sources. To a first-order approximation, weathering proceeds according to simple first-order loss-rate (FOLR) kinetics for polycyclic aromatic hydrocarbons (PAH) based on molecular size. This relationship between relative weathering rate and molecular size can be exploited to infer the initial PAH composition of spilled oils, and this information can be combined with results for weathering-invariant analytes to substantially increase the precision and accuracy of hydrocarbon source recognition methods. The approach presented here evaluates a goodness-of-fit metric between the measured hydrocarbon composition of an environmental sample and a suspected source, after correcting for PAH weathering losses based on FOLR kinetics. Variability from analytical and sampling error may thus be accounted for, and source identifications can be expressed as objective probability statements. This approach is illustrated by application to four independent case studies.  相似文献   

20.
Different monitoring parameters (PM mass concentrations, number–size distribution, black carbon, gaseous pollutants, and chemical composition, among others) are currently used in air quality studies. Urban aerosols are the result of several sources and atmospheric processes, which suggests that a single monitoring technique is insufficient to quantitatively evaluate all of them.This study assesses the suitability of a number of monitoring techniques (PM mass concentrations, number and size distribution of ultra-fine particles, levels of gaseous pollutants, and a complete chemical characterization of PM10 and PM2.5) by examining the response of those techniques to the different emission sources and/or atmospheric processes affecting an urban Mediterranean area (Barcelona, NE Spain).The results of this work reveal that the PM mass, the number concentration and the chemical composition give different, but complementary, information. Whereas the mineral matter, a key atmospheric aerosol component across the Mediterranean, is not properly quantitatively assessed by measuring sub-micrometric particles, the monitoring of the number concentration is indispensable to interpret the origin of specific aerosol episodes. Furthermore, the chemical composition yields very relevant information to deduce the causes of specific pollution episodes.The number concentration of ultra-fine particles in urban areas is strongly dependent upon vehicle exhaust emissions, which may cause adverse health impacts. Moreover, urban Mediterranean environments are favourable to produce nucleation-mode particles (<20 nm) with photochemical origin. In those cases, these particles are expected to be of high solubility and consequently their toxicity may differ from that of traffic-generated ultra-fine particles. Thus, the use of a single monitoring parameter to evaluate the health effects seems to be not enough.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号