1.
Abstract

Vanadium concentrations were determined by neutron activation analysis in samples of epiphytic lichens and tree foliage collected at sites along 10 transects in the vicinity of three oil-fired power plants in eastern Canada. The vanadium concentrations in plants decreased exponentially with increasing distance from the power plants. Substantially larger concentrations of vanadium occurred in lichen tissues than in tree foliage. Lichens clearly are more suitable for bio-monitoring environmental contamination with vanadium near oil-fired power plants.  相似文献   

2.
This is the third in a series of papers discussing the experience of electric utilities in applying baghouse technology for the collection of particulate matter at coal-fired electric power generating plants. The series presents new data obtained in research sponsored by the Electric Power Research Institute (EPRI) on reverse-gas and shake/deflate cleaned baghouses, and specifically addresses a number of unresolved issues in the design and operation of these units. This paper provides an overview of the design and operating characteristics of baghouses now in place in the utility industry. In addition, it discusses three key issues in design and operation: the relationships among dust cake weight and chemical composition, air-to-cloth ratio, and pressure drop; fabric selection; and bag life.  相似文献   

3.
This is the fifth in a series of papers discussing the experience of electric utilities in applying baghouse technology for the collection of particulate matter at coal-fired electric power generating plants. The series presents new data obtained in research sponsored by the Electric Power Research Institute (EPRI) on reverse-gas and shake/deflate cleaned baghouses, and specifically addresses a number of unresolved issues in the design and operation of these units. This paper describes research to improve reverse-gas cleaning technology, and to characterize reverse-gas sonic assisted and shake/deflate cleaning.  相似文献   

4.
This is the sixth and last part in a series of papers discussing the experience of electric utilities in applying baghouse technology for the collection of particulate matter at coal-fired electric power generating plants. The series presents new data obtained in research sponsored by the Electric Power Research Institute (EPRI) on reverse-gas and shake/deflate cleaned baghouses, and specifically addresses a number of unresolved issues in the design and operation of these units. This paper discusses research, development and demonstration activities now underway or planned to further understand baghouse technology to ensure efficient, economic and reliable service in utility applications. In addition, it summarizes the major findings reported in Parts I through V.  相似文献   

5.
Abstract

For the past 22 years in the Netherlands, the behavior of Hg in coal-fired power plants has been studied extensively. Coal from all over the world is fired in Dutch power stations. First, the Hg concentrations in these coals were measured. Second, the fate of the Hg during combustion was established by performing mass balance studies. On average, 43 ± 30% of the Hg was present in the flue gases downstream of the electrostatic precipitator (ESP; dust collector). In individual cases, this figure can vary between 1 and 100%. Important parameters are the Cl content of the fuel and the flue gas temperature in the ESP. On average, 54 ± 24% of the gaseous Hg was removed in the wet flue-gas desulfurization (FGD) systems, which are present at all Dutch coal-power stations. In individual cases, this removal can vary between 8% (outlier) and 72%.

On average, the fate of Hg entering the power station in the coal was as follows: <1% in the bottom ash, 49% in the pulverized fuel ash (ash collected in the ESP), 16.6% in the FGD gypsum, 9% in the sludge of the wastewater treatment plant, 0.04% in the effluent of the wastewater treatment plant, 0.07% in fly dust (leaving the stack), and 25% as gaseous Hg in the flue gases and emitted into the air. The distribution of Hg over the streams leaving the FGD depends strongly on the installation. On average, 75% of the Hg was removed, and the final concentration of Hg in the emitted flue gases of the Dutch power stations was only ~3 μg/mSTP 3 at 6% O2. During co-combustion with biomass, the removal of Hg was similar to that during 100% coal firing.

Speciation of Hg is a very important factor. An oxidized form (HgCl2) favors a high degree of removal. The conversion from Hg0 to HgCl2 is positively correlated with the Cl content of the fuel. A catalytic DENOX (SCR) favors the formation of oxidized Hg, and, in combination with a wet FGD, the total removal can be as high as 90%.  相似文献   

6.
The emphasis on participate control from industrial processes has been shifted recently towards fine particulates, having diameters less than 3 microns. There exists an urgent need for more scientific information of fine particle characterization.1,2 Coal and oil fired power plants are among the largest anthropogenic point sources of particulate matter.3 Limited knowledge is available on particle size distribution and trace metal composition in power plant emissions.4-7 The morphological properties of particle emissions have been largely neglected. In this report we present some information on particle characteristics for an oil-fired and coal-fired power plant.  相似文献   

7.
This paper summarizes information and results presented at the Third Conference on Fabric Filter Technology for Coal-Fired Power Plants held November 19-21, 1985 in Scottsdale, Arizona. Sponsored by the Electric Power Research Institute (EPRI), in cooperation with the Arizona Public Service Co. and Salt River Project, the conference focused on recent technological developments in the design and operation of fabric filters (baghouses) in electric utility settings. Papers were presented by individuals representing utilities, fabric filter manufacturers, research and development organizations, and regulatory agencies. Approximately 200 individuals attended the sessions. Summaries of the first two conferences and results of other fabric Biter research sponsored bv EPRI have been published previously in JAPCA.1–9  相似文献   

8.
This 2-part article deals with the technical aspects of lime/limestone scrubbers for coal-fired power plants. Part I covers process chemistry and scrubber systems. Part II (next month) will cover instrumentation, particulate removal, and sludge disposal.  相似文献   

9.
This is the conclusion of a 2-part article dealing with the technical aspects of lime/limestone scrubbers for coal-fired power plants, it covers instrumentation, participate removal and sludge disposal. Part I (June JAPCA) covered process chemistry and scrubber systems  相似文献   

10.
Abstract

The objectives of this paper are to (1) quantify variability in hourly utility oxides of nitrogen (NOx) emission factors, activity factors, and total emissions; (2) investigate the autocorrelation structure and evaluate cyclic effects at short and long scales of the time series of total hourly emissions; (3) compare emissions for the ozone (O3) season versus the entire year to identify seasonal differences, if any; and (4) evaluate interannual variability. Continuous emissions monitoring data were analyzed for 1995 and 1998 for 32 units from nine baseload power plants in the Charlotte, NC, airshed. Unit emissions have a strong 24-hr cycle attributable primarily to the capacity factor. Typical ranges of the coefficient of variation for emissions at a given hour of the day were from 0.2 to 0.45. Little difference was found when comparing weekend emissions with the entire week or when comparing the O3 season with the entire year. There were substantial differences in the mean and standard deviation of emissions when comparing 1995 and 1998 data, indicative of the effect of retrofits of control technology during the intervening time. The wide range of variability and its autocorrelation should be accounted for when developing probabilistic utility emission inventories for analysis of near-term future episodes.  相似文献   

11.
12.
PISCES, Power Plant Integrated Systems: Chemical Emissions Studies, is a multimedia chemical species project on plant emissions. Products generated in the PISCES project will help utilities design and operate their plants to minimize chemical species emissions. PISCES takes a holistic approach to the control of toxics by acknowledging that a chemical removed from a gas stream will appear in a liquid or solid stream.  相似文献   

13.
Abstract

Increased interest in the health effects of ambient par–ticulate mass (PM) has focused attention on the evaluation of existing mass measurement methodologies and the definition of PM in ambient air. The Rupprecht and Patashnick Tapered Element Oscillating MicroBalance (TEOM®) method for PM is compared with time–integrated gravimetric (manual) PM methods in large urban areas during different seasons. Comparisons are conducted for both PM10 and PM2.5 concentrations.

In urban areas, a substantial fraction of ambient PM can be semi–volatile material. A larger fraction of this component of PM10 may be lost from the TEOM–heated filter than the Federal Reference Method (FRM). The observed relationship between TEOM and FRM methods varied widely among sites and seasons. In East Coast urban areas during the summer, the methods were highly correlated with good agreement. In the winter, correlation was somewhat lower, with TEOM PM concentrations generally lower than the FRM. Rubidoux, CA, and two Mexican sites (Tlalnepantla and Merced) had the highest levels of PM10 and the largest difference between TEOM and manual methods.

PM2.5 data from collocation of 24–hour manual samples with the TEOM are also presented. As most of the semi–volatile PM is in the fine fraction, differences between these methods are larger for PM2.5 than for PM10.  相似文献   

14.
The body of information presented in this paper is directed to those individuals who may be concerned with principal plume dispersion models at coal-burning power plants. About 20 years of comprehensive field surveillance and documentation of dispersion of power plant emissions for a varied range of unit sizes, stack heights, and meteorological conditions have determined the Tennessee Valley Authority’s interpretation of principal plume dispersion models. TVA’s experience indicates that as unit sizes are increased and taller stacks are constructed, the plume dispersion model associated with maximum surface concentrations changes. Maximum surface concentrations for principal plume dispersion models were approximately equal for the early small plants. However, the coning model was considered the critical plume dispersion model because the frequency of recurrence of surface concentrations from this model was appreciably greater than other models.

There were progressive changes because of an increase in unit sizes and stack heights; the magnitude of maximum surface concentrations from the coning model decreased, and the magnitude (relative to the coning model) of concentrations from the inversion breakup model increased. However, with plumes from newer and larger units with higher stacks, the trapping dispersion model became prominent. Finally, by the time unit size had increased to 900 mw and stack height to about 245 meters, as at Bull Run Power Plant, the magnitude of surface concentrations associated with trapping had increased to such a degree that it became the critical dispersion model identified with power plants of this size.  相似文献   

15.
To preserve and improve environmental quality in a prosperous industrialized nation like the United States, we must use efficient control technology to reduce the pollution which would otherwise accompany our growth. The need for control is especially great in our use of energy. In the near term our country must depend increasingly on coal to meet our energy needs. In his 1977 energy message President Carter declared that it would be this Administration’s policy to require the use of best available control technology for all new coal burning plants. EPA is implementing this policy by adopting a rule that will require such controls on new coal-fired power plants.  相似文献   

16.
17.
ABSTRACT

The application of artificial intelligence techniques for performance optimization of the fuel lean gas reburn (FLGR) system is investigated. A multilayer, feedforward artificial neural network is applied to model static nonlinear relationships between the distribution of injected natural gas into the upper region of the furnace of a coal-fired boiler and the corresponding oxides of nitrogen (NOx) emissions exiting the furnace. Based on this model, optimal distributions of injected gas are determined such that the largest NOx reduction is achieved for each value of total injected gas. This optimization is accomplished through the development of a new optimization method based on neural networks. This new optimal control algorithm, which can be used as an alternative generic tool for solving multidimensional nonlinear constrained optimization problems, is described and its results are successfully validated against an off-the-shelf tool for solving mathematical programming problems. Encouraging results obtained using plant data from one of Commonwealth Edison's coal-fired electric power plants demonstrate the feasibility of the overall approach.

Preliminary results show that the use of this intelligent controller will also enable the determination of the most cost-effective operating conditions of the FLGR system by considering, along with the optimal distribution of the injected gas, the cost differential between natural gas and coal and the open-market price of NOx emission credits. Further study, however, is necessary, including the construction of a more comprehensive database, needed to develop high-fidelity process models and to add carbon monoxide (CO) emissions to the model of the gas reburn system.  相似文献   

18.
This paper describes an experimental, domestic-sized, oil-fired furnace to be used for evaluation of fuel additives and equipment design modifications in reducing air pollutant emissions. Operating data and emissions of particulate matter, smoke, carbon monoxide, gaseous hydrocarbons, oxides of nitrogen, and oxides of sulfur are reported over the range of operable air-fuel ratio. Emission levels are interpreted in terms of key operating parameters and potential areas for reduction of emissions.  相似文献   

19.
A large scale simulation model was employed in evaluating various policy alternatives for reducing SO2 emissions from Illinois electric power plants for a broad range of nuclear power capacity addition scenarios. A dynamic simulation of a transferable discharge permit (TDP) program suggests a market oriented management system can assure an acceptable level of environmental quality while achieving typical cost savings of 40-60 percent over a program based on uniform decreases in existing emission standards. This cost advantage can be realized without any major decline in the demand for coal generally or indigenous coals in particular. Several options for initiating the TDP market are evaluated. The analysis concludes that initiating the market by government sales may not constitute a major financial burden on the electric utilities or their customers.  相似文献   