首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Carbon monoxide exposures to commuters were simulated in a 5-day study in Los Angeles County. Exposures were determined by measuring CO in three vehicles as they traveled typical commuter routes. The data collected during this study include measurements of vehicle speed and CO measurements in the interior and exterior of the three vehicles during the morning and evening peak traffic periods. In addition, hourly averaged CO measurements were taken from eight south coastal Air Quality Management District fixed-site monitoring stations and six California Department of Transportation vans in the proximity of the commuter routes. These data were used to investigate the relationship of CO exposures to meteorological parameters, fixed-site monitors, and traffic conditions.

The average ratio of interior CO concentrations to exterior CO concentrations was 0.92. Concentrations inside and outside the vehicles remained about the same even when the vehicles were driven with vents closed and windows up. Smoking was not permitted in the vehicles during the study. The average ratio of the hour average CO concentrations in the vehicles to fixed-site measurements was 3.9. However, this ratio decreases with increasing ambient CO levels. Although CO levels in the vehicles frequently exceeded 40 ppm and sometimes exceeded 60 ppm, the hour average CO concentrations did not exceed 35 ppm. Slow moving congested traffic is associated with higher CO levels in the vehicles than a high volume of traffic moving at a steady speed.  相似文献   

2.
Abstract

This paper focuses on the auto commuting micro-environment and presents typical carbon monoxide (CO) concentrations to which auto commuters in central Riyadh, Saudi Arabia were exposed. Two test vehicles traveling over four main arterial roadways were monitored for inside and outside CO levels during eighty peak and off-peak hours extending over an eight month period. The relative importance of several variables which explained the variability in CO concentrations inside autos was also assessed. It was found that during peak hours auto commuters were exposed to mean CO levels that ranged from 30 to 40 ppm over trips that typically took between 25 to 40 minutes. The mean ratio of inside to outside CO levels was 0.84. Results of variance component analyses indicated that the most important variables affecting CO concentrations inside autos were, in addition to the smoking of vehicle occupants, traffic volume, vehicle speed, period of day and wind velocity. An increase in traffic volume from 1,000 to 5,000 vehicles per hour (vph) increased mean CO level exposure by 71 percent. An increase in vehicle speed from 14 to 55 km/h reduced mean CO exposure by 36 percent. The number of traffic interruptions had a moderate effect on mean concentrations of CO inside vehicles.  相似文献   

3.
Carbon monoxide and hydrocarbons were sampled at operator’s nose height inside vehicles moving in moderate to heavy traffic in six cities. The samples were integrated over 20-30 minutes by collection in Mylar bags. Carbon monoxide and hydrocarbons were analyzed by infrared and flame ionization, respectively, with instruments at the Continuous Air Monitoring Program (CAMP) station in each city. Detector tubes for carbon monoxide were also used to determine 5-min concentrations at suspected high points in the field. Estimates of traffic density were made. Three types of traffic arteries were considered: (7) heavily traveled, wide expressways, (2) main city streets with moderately rapid vehicular traffic, and (3) center city streets with slow-moving traffic. Integrated half-hour CO concentrations obtained within the vehicles while in traffic were generally considerably higher than the concurrent concentrations measured at the CAMP sites. In-traffic CO values in all cities sampled exceeded 30 ppm in at least 10% of the integrated samples. The range of city averages was 21–39 ppm carbon monoxide and the range of individual integrated samples was 7–77 ppm of carbon monoxide.  相似文献   

4.
A carbon monoxide analyzer has been developed which is capable of continuous measurement of the carbon monoxide concentration in the atmosphere. The operating principle of the instrument is the reaction of carbon monoxide with hot mercuric oxide followed by the photometric determination of the mercury vapor produced. Oxygenated hydrocarbons and olefins are quantitatively detected. Those normally present are in the ambient atmosphere in low concentrations relative to CO. Hydrogen and methane in the atmosphere do not interfere with the CO analysis. Measurements of atmospheric CO concentrations in California, Greenland, and Oregon seem to indicate that CO content is an air mass characteristic. North Pacific marine air mass concentrations may be as low as about 0.040 parts per million (ppm) CO, while the air mass over continental California seems to be characterized by CO levels of 0.5-1.0 ppm or greater.  相似文献   

5.
ABSTRACT

The air quality in five Finnish ice arenas with different volumes, ventilation systems, and resurfacer power sources (propane, gasoline, electric) was monitored during a usual training evening and a standardized, simulated ice hockey game. The measurements included continuous recording of carbon monoxide (CO), nitric oxide (NO), and nitrogen dioxide (NO2) concentrations, and sampling and analysis of volatile organic compounds (VOCs). Emissions from the ice resurfacers with combustion engines caused indoor air quality problems in all ice arenas. The highest 1-hour average CO and NO2 concentrations ranged from 20 to 33 mg/m3 (17 to 29 ppm) and 270 to 7440 µg/m3 (0.14 to 3.96 ppm), respectively. The 3-hour total VOC concentrations ranged from 150 to 1200 µg/m3. The highest CO and VOC levels were measured in the arena in which a gasoline-fueled resurfacer was used. The highest NO2 levels were measured in small ice arenas with propane-fueled ice resurfacers and insufficient ventilation.

In these arenas, the indoor NO2 levels were about 100 times the levels measured in ambient outdoor air, and the highest 1-hour concentrations were about 20 times the national and World Health Organization (WHO) health-based air quality guidelines. The air quality was fully acceptable only in the arena with an electric resurfacer. The present study showed that the air quality problems of indoor ice arenas may vary with the fuel type of resurfacer and the volume and ventilation of arena building. It also confirmed that there are severe air quality problems in Finnish ice arenas similar to those previously described in North America.  相似文献   

6.
Abstract

The concentrations of carbon monoxide (CO) and other gases were measured in the emissions from solid waste degradation under aerobic and anaerobic conditions during laboratory and field investigations. The emissions were measured as room temperature headspace gas concentrations in reactors of 1, 30, and 150 L, as well as sucked gas concentrations from windrow composting piles and a biocell, under field conditions. The aerobic composting laboratory experiments consisted of treatments with and without lime. The CO concentrations measured during anaerobic conditions varied from 0 to 3000 ppm, the average being 23 ppm, increasing to 133 ppm when methane (CH4) concentrations were low. The mean/maximum CO concentrations during the aerobic degradation in the 2-L reactor were 101/194 ppm without lime, 486/2022 ppm with lime, and 275/980 ppm in the 150-L reactors. The presence of CO during the aerobic composting followed a rapid decline in O2 concentrations Significantly higher CO concentrations were obtained when the aerobic degradation was amended with lime, probably because of a more extreme depletion of oxygen. The mean/maximum CO concentrations under field conditions during aerobic composting were 95/1000 ppm. The CO concentrations from the anaerobic biocell varied from 20 to 160 ppm. The hydrogen sulfide concentrations reached almost 1200 ppm during the anaerobic degradation and 67 ppm during the composting experiments. There is a positive correlation between the CO and hydrogen sulfide concentrations measured during the anaerobic degradation experiments.  相似文献   

7.
Seventeen non-smoking young men served as subjects to determine the alteration in carboxyhemoglobin (COHb) concentrations during exposure to 0 or 9 ppm carbon monoxide for 8 hours (CO) at sea level or an altitude of 2134 meters (7000 feet) in a hypobaric chamber. Nine subjects rested during the exposure and 8 exercised for 10 minutes of each exposure hour at a mean ventilation of 25 L (BTPS). All subjects performed a maximal aerobic capacity test at the completion of their respective exposures. Carboxyhemoglobin concentrations fell in all subjects during their exposures to 0 ppm CO at sea level or 2134 m. During the 8-h exposures to 9 ppm CO, COHb rose linearly from approximately 0.2 percent to 0.7 percent. No significant differences in uptake were found whether the subjects were resting or intermittently exercising during their 8-h exposures. COHb levels attained were similar at both sea level and 2134 m. Maximal aerobic capacity was reduced approximately 7-10 percent consequent to altitude exposure during 0 ppm CO exposures. These values were not altered following exposure for 8 h to 9 ppm CO in either the resting or exercising subjects.  相似文献   

8.
ABSTRACT

The effectiveness of a new emission control system in the ice resurfacer was tested in an exhaust gas emission laboratory, and the improvement of the air quality in a small, enclosed ice arena was demonstrated in a 4.5-month follow-up study. The emission control system consisted of a lambda sensor-controlled fuel supply and a three-way metallic catalyst that were applied to a propane-fueled resurfacer. In the laboratory tests, the engine emissions of carbon monoxide (CO), hydrocarbons (HC), and nitrogen oxides (NO ) reduced simultaneously by 91, 90, and 96%, respectively. During the air quality follow-up the median 1-hour average nitrogen dioxide (N02) concentration inside the ice arena decreased from 430 ug/m3 (230ppb) to 58 ug/m3 (31 ppb), and that of CO decreased from 4.4 mg/m3 (3.8 ppm) to 1.5 mg/m3 (1.3 ppm). The new emission control system proved to be a feasible, reliable, and effective means to improve the indoor air quality in the ice arena. However, continuous mechanical ventilation was necessary during all business hours in order to achieve and maintain a fully acceptable air quality with this technology.  相似文献   

9.
The concentrations of carbon monoxide (CO) and other gases were measured in the emissions from solid waste degradation under aerobic and anaerobic conditions during laboratory and field investigations. The emissions were measured as room temperature headspace gas concentrations in reactors of 1, 30, and 150 L, as well as sucked gas concentrations from windrow composting piles and a biocell, under field conditions. The aerobic composting laboratory experiments consisted of treatments with and without lime. The CO concentrations measured during anaerobic conditions varied from 0 to 3000 ppm, the average being 23 ppm, increasing to 133 ppm when methane (CH4) concentrations were low. The mean/maximum CO concentrations during the aerobic degradation in the 2-L reactor were 101/194 ppm without lime, 486/2022 ppm with lime, and 275/980 ppm in the 150-L reactors. The presence of CO during the aerobic composting followed a rapid decline in O2 concentrations Significantly higher CO concentrations were obtained when the aerobic degradation was amended with lime, probably because of a more extreme depletion of oxygen. The mean/maximum CO concentrations under field conditions during aerobic composting were 95/1000 ppm. The CO concentrations from the anaerobic biocell varied from 20 to 160 ppm. The hydrogen sulfide concentrations reached almost 1200 ppm during the anaerobic degradation and 67 ppm during the composting experiments.  相似文献   

10.
The associations of personal carbon monoxide (CO) exposures with ambient air CO concentrations measured at fixed monitoring sites, were studied among 194 children aged 3–6 yr in four downtown and four suburban day-care centers in Helsinki, Finland. Each child carried a personal CO exposure monitor between 1 and 4 times for a time period of between 20 and 24 h. CO concentrations at two fixed monitoring sites were measured simultaneously. The CO concentrations measured at the fixed monitoring sites were usually lower (mean maximum 8-h concentration: 0.9 and 2.6 mg m−3) than the personal CO exposure concentrations (mean maximum 8-h concentration: 3.3 mg m−3). The fixed site CO concentrations were poor predictors of the personal CO exposure concentrations. However, the correlations between the personal CO exposure and the fixed monitoring site CO concentrations increased (−0.03–−0.12 to 0.13–0.16) with increasing averaging times from 1 to 8 h. Also, the fixed monitoring site CO concentrations explained the mean daily or weekly personal CO exposures of a group of simultaneously measured children better than individual exposure CO concentrations. This study suggests that the short-term CO personal exposure of children cannot be meaningfully assessed using fixed monitoring sites.  相似文献   

11.
The probabilistic National Ambient Air Quality Standards (NAAQS) Exposure Model applied to carbon monoxide (pNEM/CO) was developed by the U.S. Environmental Protection Agency (EPA) to estimate frequency distributions of population exposure to carbon monoxide (CO) and the resulting carboxyhemoglobin (COHb) levels. To evaluate pNEM/CO, the model was set up to simulate CO exposure data collected during a Denver Personal Exposure Monitoring Study (PEM) conducted during the winter of 1982-1983. This paper compares computer-simulated exposure distributions obtained by pNEM/CO with the observed cumulative relative frequency distributions of population exposure to CO from 779 people in the Denver PEM study.

The subjects were disaggregated into two categories depending upon whether they lived in a home with a gas stove or an electric stove. The observed and predicted population exposure frequency distributions were compared in terms of 1-hr daily maximum exposure (1DME) and 8-hr daily maximum moving average exposure (8DME) for people living in homes with gas stove or an electric stove. For 1DME, the

computer-simulated results from pNEM/CO agreed most closely within the range of 6-13 ppm, but overestimated occurrences at low exposure (<6 ppm) and underestimated occurrences at high exposure (>13 ppm). For 8DME, the predicted exposures agreed best with observed exposures in the range of CO concentration between 5.5 and 7 ppm, and over-predicted occurrences below 5.5 ppm and under-predicted occurrences above 7 ppm.  相似文献   

12.
This paper describes a long-term trend study of passenger exposure to carbon monoxide (CO) inside a vehicle traveling on an arterial highway in northern California. CO exposure was measured during four field surveys on State Route #82 (El Camino Real) on the San Francisco Peninsula in 1980–1981, 1991–1992, 2001–2002, and 2010–2011. Each field survey took at least 12 months. Fifty trips from each survey—for a total of 200 trips—were matched by date, day of the week, and starting time of the day to facilitate comparisons over three decades. The mean net CO concentration of each trip was obtained by subtracting the background CO level from the average CO concentration for the entire trip. The mean net CO concentration (0.5 ppm) for 2010–2011 was only 5.2% of that (9.7 ppm) for 1980–1981. For the 50 trips, the average travel time for the 1980–1981 period (39.6 min) was only 8.3% higher than during the 2010–2011 period (36.3 min). The estimated round-trip distance on the highway was held constant at 11.8 miles. The reduction in the mean net CO concentration was attributed to more stringent CO emission standards on new vehicles sold in California since 1980. The state’s cold-temperature CO standard implemented in 1996 appeared to reduce high CO concentrations that were observed during the late fall and winter of 1980–1981. In addition, the observed standard deviation in concentration fell from 3.1 ppm in 1980–1981 to 0.2 ppm in 2010–2011, and the range of the 50 mean net CO concentrations narrowed from 14.9 ppm in 1980–1981 to 1.1 ppm in 2010–2011, but the relative variability, as indicated by the geometric standard deviation, remained the same. These results have important scientific implications for regulatory policies designed to control air pollution from motor vehicles.

Implications: Many developing countries launched or expanded their mobile source emission control programs in the 1990s, yet many of them do not have adequate inspection and maintenance (I/M) programs. The El Camino Real study shows the long-term public health benefits of more stringent motor vehicle emission standards for carbon monoxide (CO) on new cars and of an I/M program (Smog Check) on the existing fleet in California. The study provides a protocol for conducting standardized field surveys of in-vehicle exposure on a periodic basis. Such surveys would enable developing countries to assess the progress of their mobile source emission control programs.  相似文献   


13.
Eleven new cars were driven around a 35 km route comprising heavily trafficked roads in and around London, and the concentrations of carbon monoxide inside and immediately outside the vehicles were continuously monitored. Average levels of CO between 12 and 60 parts per million were found inside the cars, and these levels were between 30 and 80% of the external concentrations. The internal levels varied according to external changes but the changes were greatly damped by the buffering effect of the ventilation system. Differences in internal CO levels were more marked between vehicles than for different runs in the same vehicle and were probably due to differences in the ventilation systems.

Blood carboxy-hemoglobin concentrations which would arise from the CO exposures were calculated. Published data suggest that carboxy-hemoglobin concentrations within the range found (1.5-3.0%) would not be expected to produce an adverse effect on health; there are conflicting views as to whether driving performance would be impaired.  相似文献   

14.
The U.S. EPA studied the carbon monoxide (CO) exposures and resulting breath CO concentrations of 625 non-smoking persons in Washington, D.C., and 454 non-smokers in Denver, CO, in the winter of 1982–83. Mean population-weighted breath concentrations were 5.1 ± 0.2 (SE) ppm in Washington and 7.2 ± 0.2 ppm in Denver. These values were correlated with the preceding personal air CO exposures (Spearman rank correlation coefficient rs > 0.5, P < 0.0001) but not with the outdoor concentrations (rs < 0.2). However, the breath measurements did not agree very closely with the personal exposures according to the current (Coburn) model relating alveolar CO to ambient CO. One reason for the discrepancy may have been the slight observed negative bias displayed by the personal monitors. A method of using the breath measurements to arrive at an improved estimate of personal exposures has been developed and applied. The method leads to an upward revision of exposure estimates: about 10% of the Washington target population of 1.22 million non-smokers are estimated to have exceeded the EPA 8-h ambient standard of 9 ppm during the winter of 1982–83, well above the 3.5% indicated by the personal monitor measurements.  相似文献   

15.
Abstract

House depressurization occurs when household equipment such as a kitchen or bathroom fan or a fireplace exhausts air from the house and lowers the pressure indoors with respect to the outside. The operation of air handlers for forced-air heating or cooling systems also can have a depressurization effect. This depressurization can hinder the natural draft from vented combustion appliances and lead to backdrafting, which in turn can result in combustion gases spilling into the indoor airspace. Extensive spillage can cause elevated indoor levels of combustion products such as carbon dioxide (CO2) and water vapor, as well as contaminants such as carbon monoxide (CO) and nitrogen dioxide (NO2).

The focus of this paper is to review studies on depressurization- induced backdrafting and spillage from gas-fired, drafthood equipped furnaces and domestic hot water heaters. Qualitative and quantitative techniques that were used in depressurization and backdrafting studies conducted in Canada, Europe, and the United States are analyzed. These studies have shown that exhaust fans operated simultaneously with fireplaces depressurize houses by 3 to 8 Pa on average. The CO indoor concentrations due to spillage, as reported in these studies, generally have been lower than 5 ppm. However, such low CO concentrations do not necessarily imply that a potential problem associated with backdrafting does not exist. Other combustion products, such as NO2, rarely have been measured in prior backdrafting studies.

It can be concluded from the literature review that causes of house depressurization are well understood. However, more comprehensive research is needed to better understand the frequency, duration, and severity of depressurization-induced spillage in a broad cross section of houses. Efforts in this direction have begun recently in the United States through a workshop to define research issues, pilot studies to develop comprehensive measurement protocols, and consensus standard development activities to prepare standardized methods and protocols.  相似文献   

16.
The interest in biomass fuel is continuing to expand globally and in the northeastern United States as wood pellets are becoming a primary source of fuel for residential and small commercial systems. Wood pellets for boilers are often stored in basement storage rooms or large bag-type containers. Due to the enclosed nature of these storage areas, the atmosphere may exhibit increased levels of carbon monoxide. Serious accidents in Europe have been reported over the last decade in which high concentrations of carbon monoxide (CO) have been found in or near bulk pellet storage containers. The aim of this study was to characterize the CO concentrations in areas with indoor storage of bulk wood pellets. Data was obtained over approximately 7 months (December 2013 to June 2014) at 25 sites in New Hampshire and Massachusetts: 16 homes using wood pellet boilers with indoor pellet storage containers greater than or equal to 3 ton capacity; 4 homes with wood pellet heating systems with outdoor pellet storage; 4 homes using other heating fuels; and a university laboratory site. CO monitors were set up in homes to collect concentrations of CO in the immediate vicinity of wood pellet storage containers, and data were then compared to those of homes using fossil fuel systems. The homes monitored in this study provided a diverse set of housing stock spanning two and a half centuries of construction, with homes built from 1774 to 2013, representing a range of air exchange rates. The CO concentration data from each home was averaged hourly and then compared to a threshold of 9 ppm. While concentrations of CO were generally low for the homes studied, the need to properly design storage locations for pellets is and will remain a necessary component of wood pellet heating systems to minimize the risk of CO exposure.

Implications: This paper is an assessment of carbon monoxide (CO) exposure from bulk wood pellet storage in homes in New Hampshire and Massachusetts. Understanding the CO concentrations in homes allows for better designs for storage bins and ventilation for storage areas. Hence, uniform policies for stored wood pellets in homes, schools, and businesses can be framed to ensure occupant safety. Currently in New York State rebates for the installation of wood pellet boilers are only provided if the bulk pellet storage is outside of the home, yet states such as New Hampshire, Vermont, and Maine currently do not have these restrictions.  相似文献   


17.
During the fall of 1972, a study was undertaken to characterize gaseous air pollutants in the St. Louis metropolitan area. Information obtained in this study will be used in planning air pollution modeling studies to be carried out over the next 4 or 5 years under the Regional Air Pollution Study (RAPS) of the Environmental Protection Agency. From analyses of roadway samples, it was found that certain compounds in automotive emissions such as acetylene, carbon monoxide, o-xylene, ethylene, and 2-methylpentane occur in consistent proportions to other compounds. The concentrations of these indicator compounds in atmospheric samples were used to estimate the amounts of other hydrocarbons present that are attributable to automotive related emissions. Methane, ethane, and propane were found to originate principally from nonautomotive sources, both at St. Louis University and the St. Louis CAMP station. Similar concentrations were found in urban and non-urban areas. A comparison of ethylene-CO and propyl-ene-CO ratios in urban and non-urban areas indicates that CO can serve as an indicator of transport of urban pollutants. Sunlight irradiations of captured air samples showed increasing ozone production with increasing initial concentrations of hydrocarbons and nitrogen oxides. Substantial ozone and peroxyacetyl nitrate were formed from a total non-methane hydrocarbon concentration of only 1/4 ppm C.  相似文献   

18.
Use of vent-free gas heating appliances for supplemental heating in U.S. homes is increasing. However, there is currently a lack of information on the potential impact of these appliances on indoor air quality for homes constructed according to energy-efficient and green building standards. A probabilistic analysis was conducted to estimate the impact of vent-free gas heating appliances on indoor air concentrations of carbon monoxide (CO), nitrogen dioxide (NO2), carbon dioxide (CO2), water vapor, and oxygen in “tight” energy-efficient homes in the United States. A total of 20,000 simulations were conducted for each Department of Energy (DOE) heating region to capture a wide range of home sizes, appliance features, and conditions, by varying a number of parameters, e.g., room volume, house volume, outdoor humidity, air exchange rates, appliance input rates (Btu/hr), and house heat loss factors. Predicted airborne levels of CO were below the U.S. Environmental Protection Agency (EPA) standard of 9 ppm for all modeled cases. The airborne concentrations of NO2 were below the U.S. Consumer Product Safety Commission (CPSC) guideline of 0.3 ppm and the Health Canada benchmark of 0.25 ppm in all cases and were below the World Health Organization (WHO) standard of 0.11 ppm in 99–100% of all cases. Predicted levels of CO2 were below the Health Canada standard of 3500 ppm for all simulated cases. Oxygen levels in the room of vent-free heating appliance use were not significantly reduced. The great majority of cases in all DOE regions were associated with relative humidity (RH) levels from all indoor water vapor sources that were less than the EPA-recommended 70% RH maximum to avoid active mold and mildew growth. The conclusion of this investigation is that when installed in accordance with the manufacturer’s instructions, vent-free gas heating appliances maintain acceptable indoor air quality in tight energy-efficient homes, as defined by the standards referenced in this report.

Implications: Probabilistic modeling of indoor air concentrations of carbon monoxide (CO), nitrogen dioxide (NO2), carbon dioxide (CO2), water vapor, and oxygen associated with use of vent-free gas heating appliances provides new data indicating that uses of these devices are consistent with acceptable indoor air quality in “tight” energy-efficient homes in the United States. This study will provide authoritative bodies such as the International Code Council with definitive information that will assist in the development of future versions of national building codes, and will provide evaluation of the performance of unvented gas heating products in energy conservation homes.  相似文献   


19.
Carbon monoxide (CO) exposures were measured inside a motor vehicle during 88 standardized drives on a major urban arterial highway, El Camino Real (traffic volume of 30,500-45,000 vehicles per day), over a 13-1/2 month period. On each trip (lasting between 31 and 61 minutes), the test vehicle drove the same 5.9-mile segment of roadway in both directions, for a total of 11.8 miles, passing through 20 intersections with traffic lights (10 in each direction) in three California cities (Menlo Park, Palo Alto, and Los Altos). Earlier tests showed that the test vehicle was free of CO intrusion. For the 88 trips, the mean CO concentration was 9.8 ppm, with a standard deviation of 5.8 ppm. Of nine covariates that were examined to explain the variability in the mean CO exposures observed on the 88 trips (ambient CO at two fixed stations, atmospheric stability, seasonal trend function, time of day, average surrounding vehicle count, trip duration, proportion of time stopped at lights, and instrument type), a fairly strong seasonal trend was found. A model consisting of only a single measure of traffic volume and a seasonal trend component had substantial predictive power (R2 = 0.68); by contrast, the ambient CO levels, although partially correlated with average exposures, contributed comparatively little predictive power to the model. The CO exposures experienced while drivers waited at the red lights at an intersection ranged from 6.8 to 14.9 ppm and differed considerably from intersection to intersection. A model also was developed to relate the short-term variability of exposures to averaging time for trip times ranging from 1 to 20 minutes using a variogram approach to deal with the serial autocorrelation. This study shows: (1) the mass balance equation can relate exterior CO concentrations as a function of time to interior CO concentrations; (2) CO exposures on urban arterial highways vary seasonally; (3) momentary CO exposures experienced behind red lights vary with the intersection; and (4) an averaging time model can simulate exposures during short trips (20 minutes or less) on urban arterial highways.  相似文献   

20.
Commuters’ exposure measurements were taken for PM2.5, carbon monoxide (CO) and benzene in minibuses, buses and metro during morning and evening rush hours during January–March 2003 in Mexico City. For PM2.5, the chemical composition was characterized. Total carbon was the most abundant species in fine particles (approximately 50%). Minibuses (49 μg m−3) and buses had similar concentrations of exposure for PM2.5 (53 μg m−3). For CO and benzene the concentrations were higher in minibuses. Morning rush hour was the commuting period with the highest concentrations for minibuses and buses. Metro was the mode of transport with lower concentrations for all pollutants. Carbon monoxide concentrations were similar to those identified in a previous campaign in 2002 and approximately 3.5 times lower than those in a study conducted in 1991. Benzene was characterized systematically in the selected modes of transport. A strong association was observed between wind speed and pollutant concentrations in buses.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏