首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Personal exposures and microenvironmental concentrations of benzene were measured in the residential indoor, residential outdoor and workplace environments for 201 participants in Helsinki, Finland, as a component of the EXPOLIS-Helsinki study. Median benzene personal exposures were 2.47 (arithmetic standard deviation (ASD)=1.62) μg m−3 for non-smokers, 2.89 (ASD=3.26) μg m−3 for those exposed to environmental tobacco smoke in any microenvironment and 3.08 (ASD=10.04) μg m−3 for active smokers. Median residential indoor benzene concentrations were 3.14 (ASD=1.51) μg m−3 and 1.87 (ASD=1.93) μg m−3 for environments with and without tobacco smoke, respectively. Median residential outdoor benzene concentrations were 1.51 (ASD=1.11) μg m−3 and median workplace benzene concentrations were 3.58 (ASD=1.96) μg m−3 and 2.13 (ASD=1.49) μg m−3 for environments with and without tobacco smoke, respectively. Multiple step-wise regression identified indoor benzene concentrations as the strongest predictor for personal benzene exposures of those not exposed to tobacco smoke, followed sequentially by time spent in a car, time in the indoor environment, indoor workplace concentrations and time in the home workshop. Relationships between indoor and outdoor microenvironment concentrations and personal exposures showed considerable variation between seasons, due to differences in ventilation patterns of homes in these northern latitudes. Automobile use-related activities were significantly associated with elevated benzene levels in personal and indoor measurements when tobacco smoke was not present, which demonstrates the importance of personal measurements in the assessment of exposure to benzene.  相似文献   

2.
A comprehensive assessment of indoor carbonyl compounds for the academic staff, workers, and students was conducted on a university campus in Xiamen, China. A total of 15 representative environment categories, including 12 indoor workplaces and three residential units, were selected. The potential indoor pollution sources were identified based on the variability in the molar compositions and correlation analyses for the target carbonyls. Furnishing materials, cooking emissions, and electronic equipment, such as photocopiers, can generate various carbonyls in the workplace. Comparison studies were conducted in the clerical offices, demonstrating that off-gases from wooden furniture and lacquer coatings, environmental tobacco smoke (ETS), and the use of cleaning reagents elevated the indoor carbonyl levels. The measured concentrations of formaldehyde and acetaldehyde in most locations surpassed the exposure limit levels. The lifetime cancer hazard risk (R) associated with formaldehyde was above the concern risk level (1 × 10?6) in all of the workplaces. The results indicate that formaldehyde exposure is a valid occupational health and safety concern. Wooden furniture and refurbishing materials can pose serious health threats to occupants. The information in this study could act as a basis for future indoor air quality monitoring in Mainland China.
Implications:A university campus represents a microscale city environment consisting of all the working, living, and commercial needs of staff and students. The scope of this investigation covers 21 hazardous carbonyl species based on samples collected from 15 categories of workplaces and residential building in a university campus in southern China. Findings of the study provide a comprehensive assessment of indoor air quality with regards to workers’ health and safety. No similar study has been carried out in China.  相似文献   

3.
ABSTRACT

As part of a pilot study into the chemical and physical properties of Australian fine particles, a suite of aerosol samples was collected at Ti Tree Bend in Launceston, Tasmania, during June and July 1997. This period represents midwinter in the Southern Hemisphere, a period when aerosol sources in Launceston are dominated by smoke from domestic wood burning. This paper describes the results from this measurement campaign, with the aim of assessing the effect of wood smoke on the chemical and physical characteristics of ambient aerosol. A micro orifice uniform deposit impactor (MOUDI) was used to measure the size distributions of the aerosol from 0.05 to 20 n m aerodynamic diameter. Continuous measurements of fine particle mass were made using a PM2.5 tapered element oscillating microbalance (TEOM) and light scattering coefficients at 530 nm were measured with nephelometers.

Mass size distributions tended to be bimodal, with the diameter of the dominant mode tending to smaller sizes with increases in total mass. Non-sea salt potassium and polycyclic aromatic hydrocarbons (PAHs) were used as chemical tracers for wood smoke. Wood smoke was found to increase absolute particle mass (enough to regularly exceed air quality standards), and to concentrate mass in a single mode below 1 μm aerodynamic diameter. The acid-base equilibrium of the aerosol was altered by the wood smoke source, with free acidity hydrogen ion, non-sea salt sulfate, and ammonium concentrations being higher and the concentration of all species, including nitrate (to differing extents), focused in the fine particle size ranges. The wood smoke source also heavily influenced the aerosol scattering efficiency, adding to a strong diurnal cycle in both mass concentration and light scattering.  相似文献   

4.
Smoke from large scale fuel reduction fires in Western Australia has been investigated from an aircraft; These fires are typically 10,000-20,000 acres in area with fuel loadings of 3-6 tons/acre. Measurements were made of mass concentration, scattering coefficient and total particulate production in the smoke. The results suggest that the mass concentration (g m-3) is equal to 0.24 times the scattering coefficient (m-1). About 1.8% of the fuel appears as particulate matter in the air above the fire.  相似文献   

5.
An apartment bedroom located in a residential area of Aveiro (Portugal) was selected with the aim of characterizing the cellulose content of indoor aerosol particles. Two sets of samples were taken: (1) PM10 collected simultaneously in indoor and outdoor air; (2) PM10 and PM2.5 collected simultaneously in indoor air. The aerosol particles were concentrated on quartz fibre filters with low-volume samplers equipped with size selective inlets. The filters were weighed and then extracted for cellulose analysis by an enzymatic method. The average indoor cellulose concentration was 1.01 ± 0.24 μg m?3, whereas the average outdoor cellulose concentration was 0.078 ± 0.047 μg m?3, accounting for 4.0% and 0.4%, respectively, of the PM10 mass. The corresponding average ratio between indoor and outdoor cellulose concentrations was 11.1 ± 4.9, indicating that cellulose particles were generated indoors, most likely due to the handling of cotton-made textiles as a result of routine daily activities in the bedroom. Indoor cellulose concentrations averaged 1.22 ± 0.53 μg m?3 in the aerosol coarse fraction (determined from the difference between PM10 and PM2.5 concentrations) and averaged 0.38 ± 0.13 μg m?3 in the aerosol fine fraction. The average ratio between the coarse and fine fractions of cellulose concentrations in the indoor air was 3.6 ± 2.1. This ratio is in line with the primary origin of this biopolymer. Results from this study provide the first experimental evidence in support of a significant contribution of cellulose to the mass of suspended particles in indoor air.  相似文献   

6.
ABSTRACT

Indoor air quality has become a critical issue because people spend most of their time in the indoor environment. The factors that influence indoor air quality are very important to environmental sanitation and air quality improvement. This study focuses on monitoring air quality, colony counts, and bacteria species of the indoor air of a nursing care institution. The regular colony counts in two different wards range from 55 to 600 cfu m?3. Regression analysis results indicate that the bacterial colony counts have close correlation with relative humidity or carbon dioxide (CO2) but not with carbon monoxide (CO) or ozone (O3). Real-time PCR was used to quantify the bacterial pathogens of nosocomial infection, including Acinetobacter baumannii, Citrobacter freundii, Escherichia coli, Klebsiella pneumoniae, and methicillin-sensitive Staphylococcus aureus. The most abundant bacteria species in the air of the nursing care institution is E. coli.
IMPLICATIONS Indoor temperature, humidity, ventilation, accumulation of biological pollutants, and potential infection problems will seriously affect the indoor environments. Studying these factors is important to indoor environmental sanitation and air quality improvements. Results of using real-time PCR to evaluate the bacterial pathogens of nosocomial infection for a nursing care institution in Taiwan reveal that the main bacteria species existing in the indoor air is E. coli.  相似文献   

7.
In developed nations people spend about 90% of their time indoors. The relationship between indoor and outdoor air pollution levels is important for the understanding of the health effects of outdoor air pollution. Although other studies describe both the outdoor and indoor atmospheric environment, few excluded a priori major indoor sources, measured the air exchange rate, included more than one micro-environment and included the presence of human activity. PM2.5, soot, NO2 and the air exchange rate were measured during winter and summer indoors and outdoors at 18 homes (mostly apartments) of 18 children (6–11-years-old) and also at the six schools and 10 pre-schools that the children attended. The three types of indoor environments were free of environmental tobacco smoke and gas appliances, as the aim was to asses to what extent PM2.5, soot and NO2 infiltrate from outdoors to indoors. The median indoor and outdoor PM2.5 levels were 8.4 μg m?3 and 9.3 μg m?3, respectively. The median indoor levels for soot and NO2 were 0.66 m?1 × 10?5 and 10.0 μg m?3, respectively. The respective outdoor levels were 0.96 m?1 × 10?5 and 12.4 μg m?3. The median indoor/outdoor (I/O) ratios were 0.93, 0.76 and 0.92 for PM2.5, soot and NO2, respectively. Their infiltration factors were influenced by the micro-environment, ventilation type and air exchange rate, with aggregated values of 0.25, 0.55 and 0.64, respectively. Indoor and outdoor NO2 levels were strongly associated (R2 = 0.71), followed by soot (R2 = 0.50) and PM2.5 (R2 = 0.16). In Stockholm, the three major indoor environments occupied by children offer little protection against combustion-related particles and gases in the outdoor air. Outdoor PM2.5 seems to infiltrate less, but indoor sources compensate.  相似文献   

8.
The Mechanistic Indicators of Childhood Asthma (MICA) study in Detroit, Michigan introduced a participant-based approach to reduce the resource burden associated with collection of indoor and outdoor residential air sampling data. A subset of participants designated as MICA-Air conducted indoor and outdoor residential sampling of nitrogen dioxide (NO2), volatile organic compounds (VOCs), and polycyclic aromatic hydrocarbons (PAHs). This participant-based methodology was subsequently adapted for use in the Vanguard phase of the U.S. National Children’s Study. The current paper examines residential indoor and outdoor concentrations of these pollutant species among health study participants in Detroit, Michigan.Pollutants measured under MICA-Air agreed well with other studies and continuous monitoring data collected in Detroit. For example, NO2 and BTEX concentrations reported for other Detroit area monitoring were generally within 10–15% of indoor and outdoor concentrations measured in MICA-Air households. Outdoor NO2 concentrations were typically higher than indoor NO2 concentration among MICA-Air homes, with a median indoor/outdoor (I/O) ratio of 0.6 in homes that were not impacted by environmental tobacco smoke (ETS) during air sampling. Indoor concentrations generally exceeded outdoor concentrations for VOC and PAH species measured among non-ETS homes in the study. I/O ratios for BTEX species (benzene, toluene, ethylbenzene, and m/p- and o-xylene) ranged from 1.2 for benzene to 3.1 for toluene. Outdoor NO2 concentrations were approximately 4.5 ppb higher on weekdays versus weekends. As expected, I/O ratios pollutants were generally higher for homes impacted by ETS.These findings suggest that participant-based air sampling can provide a cost-effective alternative to technician-based approaches for assessing indoor and outdoor residential air pollution in community health studies. We also introduced a technique for estimating daily concentrations at each home by weighting 2- and 7-day integrated concentrations using continuous measurements from regulatory monitoring sites. This approach may be applied to estimate short-term daily or hourly pollutant concentrations in future health studies.  相似文献   

9.
Abstract

An airborne lidar was used to study the smoke plume from the burning of a controlled oil spill on the ocean. The ratio of the amount of light (at a wavelength, λ, of 0.532 u.m) backscattered by the smoke to the amount of light extinguished by the smoke was determined by measuring the strength of a laser beam after it had passed through the smoke plume, been reflected from the ocean, and passed through the smoke plume again, and comparing this to the strength of the laser beam reflected directly from the ocean. The optical depth of the smoke (at λ = 0.532 µm) was typically between 0.2 and 0.5. The mass fluxes of smoke particles that passed through four vertical cross sections of the (nonsteady state) smoke plume were estimated from lidar measurements to be 142, 175, 423, and 414 g s-1, compared to an average smoke mass production rate of ~770 g s-1. The spatial distribution of smoke mass along the long axis of the plume was also estimated from the lidar measurements; derived smoke mass concentrations were generally <300 µg m-3, with a few isolated values up to ~800 µg m-3.  相似文献   

10.
Inhaling particulate matter (PM) in environmental tobacco smoke (ETS) endangers the health of nonsmokers. Menthol, an additive in cigarettes, attenuates respiratory irritation of tobacco smoke. It reduces perceptibility of smoke and therefore passive smokers may inhale ETS unnoticed. To investigate a possible effect of menthol on PM concentrations (PM10, PM2.5, and PM1), ETS of four mentholated cigarette brands (Elixyr Menthol, Winston Menthol, Reyno Classic, and Pall Mall Menthol Blast) with varying menthol content was analyzed. ETS was generated in a standardized way using an automatic environmental tobacco smoke emitter (AETSE), followed by laser aerosol spectrometry. This analysis shows that the tested cigarette brands, despite having different menthol concentrations, do not show differences with regard to PM emissions, with the exception of Reyno Classic, which shows an increased emission, although the menthol level ranged in the midfield. More than 90% of the emitted particles had a size smaller than or equal to 1 µm. Regardless of the menthol level, the count median diameter (CMD) and the mass median diameter (MMD) were found to be 0.3 µm and 0.5 µm, respectively. These results point out that there is no effect of menthol on PM emission and that other additives might influence the increased PM emission of Reyno Classic.

Implications: Particulate matter (PM) in ETS endangers the health of nonsmokers and smokers. This study considers the effect of menthol, an additive in cigarettes, on PM emissions. Does menthol increase the amount of PM? Due to the exposure to secondhand smoke nearly 900,000 people die each year worldwide. The aim of the study is to measure the particle concentration (L?1), mass concentration (µg m?3), and dust mass fractions shown as PM10, PM2.5, and PM1 of five different cigarette brands, including four with different menthol concentrations and one menthol-free reference cigarette, in a well-established standardized system.  相似文献   

11.
In this paper we present the development and application of a model for indoor air quality. The model represents a departure from the standard box models typically used for indoor environments which has applicability in residences and office buildings. The model has been developed for a physical system consisting of sequential compartments which communicate only with adjacent compartments. Each compartment may contain various source and sink terms for a pollutant as well as leakage, and air transfer from adjacent compartments. The mathematical derivation affords rapid calculation of equilibrium concentrations in an essentially unlimited number of compartments. The model has been applied to air quality in the passenger cabin of three commercial aircraft. Simulations have been performed for environmental tobacco smoke (ETS) under two scenarios, CO2 and water vapor. Additionally, concentrations in one aircraft have been simulated under conditions different from the standard configuration. Results of the simulations suggest the potential for elevated concentrations of ETS in smoking sections of non-air-recirculating aircraft and throughout the aircraft when air is recirculated. Concentrations of CO2 and water vapor are consistent with expected results. We conclude that this model may be a useful tool in understanding indoor air quality in general and on aircraft in particular.  相似文献   

12.
Abstract

A kinetic model for a cycling adsorbent/photocatalyst combination for formaldehyde removal in indoor air (Chin et al. J. Catalysis 2006, 237, 29-37) was previously developed in our lab, demonstrating agreement with lab-scale batch operation data of other researchers (Shiraishi et al. Chem. Engineer. Sci. 2003, 58, 929-934). Model parameters evaluated included adsorption equilibrium and rate constants for the adsorbent (activated carbon) honeycomb rotor, and catalytic rate constant for pseudo-first-order formaldehyde destruction in the titanium dioxide photoreactor. This paper explores design consequences for this novel system. In particular, the batch parameter values are used to model both adsorbent and photocatalyst behavior for continuous operation in typical residential home challenges. Design variables, including realistic make-up air fraction, adsorbent honeycomb rotation speed, and formaldehyde source emission rate, are considered to evaluate the ability of the system to achieve World Health Organization pollutant guidelines. In all circumstances, the size of the required rotating adsorbent bed and photoreactor for single-stage operation and the resultant formaldehyde concentration in the home are calculated. The ability of how well such a system might be accommodated within the typical dimensions of commercial ventilation ducts is also considered.  相似文献   

13.
ABSTRACT

Recently developed models and data describing the interactions of gas-phase semi-volatile organic compounds with indoor surfaces are employed to examine the effects of sorption on nicotine's suitability as an environmental tobacco smoke (ETS) marker. Using parameters from our studies of nicotine sorption on carpet, painted wallboard, and stainless steel and previously published data on ETS particle deposition, the dynamic behavior of nicotine was modeled in two different indoor environments: a house and a stainless steel chamber. The results show that apparently contradictory observations of nicotine's behavior in indoor air can be understood by considering the effects of sorption under different experimental conditions. In indoor environments in which smoking has occurred regularly for an extended period, the sorbed mass of nicotine is very large relative to the mass emitted by a single cigarette. The importance of nicotine adsorption relative to ventilation as a gas-phase removal mechanism is reduced. Where smoking occurs less regularly or the indoor surfaces are cleaned prior to smoking (as in a laboratory chamber), nicotine deposition is more significant. Nicotine concentrations closely track the levels of other ETS constituents in environments with habitual smoking if the data are averaged over a period significantly longer than the period between cigarette combustion episodes. However, nicotine is not a suitable tracer for predicting ETS exposures at fine time scales or in settings where smoking occurs infrequently and irregularly.  相似文献   

14.
Observations of smog over the Los Angeles Basin (LAB) links high oxidant mixing ratios with poor visibility, sometimes <5 km. By the 1970s, investigators recognized that most of the aerosol affecting visibility was from gaseous oxidation products, sulfate, nitrate, and organic carbon. This led to the 1972–1973 Aerosol Characterization Experiment (ACHEX), which included observations at the ground and from aircraft. Part of ACHEX was the measurement of smog by blimp in a Lagrangian-like format. The experiment on September 6, 1973, demonstrated that a blimp could travel with the wind across the LAB, observing ozone (O3) and precursors, and particles of different size ranges. These included condensation nuclei (CN) concentrations dominated by particles of ≤ 0.1 µm diameter and light scattering coefficient (bsc) representing mainly particles of 0.1–2.0 µm diameter. The results indicated a pollutant variation similar to that measured at a fixed site. Ozone was produced in an air mass, reaching a maximum of ~400 ppb in the presence of nitrogen oxides (NOx) and nonmethane hydrocarbons (NMHCs), then declined. Although the photochemistry was developing, bsc grew with O3 mixing ratio to a quasi-steady state at ~9–10 × 10?4 m?1, decreasing in value much later with decease in O3. The light scattering coefficient was found to be positively associated with the O3 mixing ratio, whereas CN concentrations were negatively proportional to O3 mixing ratio. The blimp experiment was supported with aircraft vertical profiles and ground-level observations from a mobile laboratory. The blimp flight obtained combined gas and particle changes aloft that could not be obtained by ground or fixed-wing aircraft measurements alone. The experiment was partially successful in achieving a true Lagrangian characterization of smog chemistry in a constrained or defined “open” air mass.

Implications: The Los Angeles experiment demonstrated the use of a blimp as a platform for measurement of air pollution traveling with an air mass across an urban area. The method added unique data showing the relationship between photochemical smog chemistry and aerosol dynamics in smog. The method offers an alternative to reliance on smog chamber and modeling observations to designing air quality management strategies for reactive pollutants.  相似文献   

15.
Because of the mutagenic and/or carcinogenic properties, Polycyclic Aromatic Hydrocarbons (PAH), have a direct impact on human population. Consequently, there is a widespread interest in analysing and evaluating the exposure to PAH in different indoor environments, influenced by different emission sources. The information on indoor PAH is still limited, mainly in terms of PAH distribution in indoor particles of different sizes; thus, this study evaluated the influence of tobacco smoke on PM10 and PM2.5 characteristics, namely on their PAH compositions, with further aim to understand the negative impact of tobacco smoke on human health. Samples were collected at one site influenced by tobacco smoke and at one reference (non-smoking) site using low-volume samplers; the analyses of 17 PAH were performed by Microwave Assisted Extraction combined with Liquid Chromatography (MAE–LC). At the site influenced by tobacco smoke PM concentrations were higher 650% for PM10, and 720% for PM2.5. When influenced by smoking, 4 ring PAH (fluoranthene, pyrene, and chrysene) were the most abundant PAH, with concentrations 4600–21 000% and 5100–20 800% higher than at the reference site for PM10 and PM2.5, respectively, accounting for 49% of total PAH (ΣPAH). Higher molecular weight PAH (5–6 rings) reached concentrations 300–1300% and 140–1700% higher for PM10 and PM2.5, respectively, at the site influenced by tobacco smoke. Considering 9 carcinogenic PAH this increase was 780% and 760% in PM10 and PM2.5, respectively, indicating the strong potential risk for human health. As different composition profiles of PAH in indoor PM were obtained for reference and smoking sites, those 9 carcinogens represented at the reference site 84% and 86% of ΣPAH in PM10 and PM2.5, respectively, and at the smoking site 56% and 55% of ΣPAH in PM10 and PM2.5, respectively. All PAH (including the carcinogenic ones) were mainly present in fine particles, which corresponds to a strong risk for cardiopulmonary disease and lung cancer; thus, these conclusions are relevant for the development of strategies to protect public health.  相似文献   

16.
Abstract

The purpose of this study was to characterize and measure indoor air quality in public facilities and office buildings. The pollutants of interest were particulate matter smaller than 2.5 μm in diameter, PM-2.5, and environmental tobacco smoke (ETS). Integrated PM- 2.5 samples were taken on Teflon membrane filters using Harvard Aerosol Impactors as a pre-size selector. Filters were analyzed by gravimetric analysis. Nicotine, which was used as a marker for ETS, was collected on sodium-bisulfate-impregnated, glass-fiber filters and was analyzed by gas chromatography. Twenty-one structures were monitored in Metropolitan Boston. Measured particle concentrations ranged from 6.0 μg/m3 to about 550 μg/m3. Nicotine concentrations were as high as 26 μg/m3 in a designated smoking room. Real-time measurements were also taken using two types of nephelometers; a Handheld Aerosol Monitor (HAM) and a Miniature Real-Time Aerosol Monitor (MINIRAM). Short-term field measurements with these instruments correlated better with the integrated PM-2.5 concentrations in smoking locations than with concentrations in non-smoking areas.  相似文献   

17.
Abstract

A high-efficiency particulate air (HEPA)-carbon filtration system was developed by the Access Business Group, LLC, to reduce the indoor levels of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). The HEPA filter removes the particle-bound PCDD/Fs, and the carbon filter removes the gaseous fraction. Because of the toxicity of PCDD/Fs, it is very difficult to handle them in the laboratory. In this study, mathematical modeling was performed to evaluate the performance of the HEPA-carbon filtration system for PCDD/Fs removal and to optimize its design and operation. The model was calibrated with experimental data conducted with toluene in a sealed room. Model simulations with four selected congeners demonstrated that it takes ~1 hr for the indoor air treatment system to reach the maximum removal efficiency and that the carbon air filter has a life time of 107 yr for dioxin removal. Given a zero emission from the HEPA filter, the overall removal efficiency is 78.7% for 2,3,7,8-tetrachloro dibenzo-p-dioxins, 89.8% for octa-chlorodibenzodioxin, 78% for tetra-chlorodibenzofuran, and 89.8% for octachlorodibenzofuran. The larger the mass emission from the HEPA filter, the lower the overall removal efficiency, and the larger the ratio of the filter flow rate (Qf) to the room flow rate (Q), the higher the overall removal efficiency. When the ratio of Qf/Q is 15, an overall removal efficiency of 90% can be reached for all four of the selected compounds. The removal of the four selected compounds does not change as the relative humidity increases ≤90%.  相似文献   

18.
Abstract

Two models for evaluating the contents and advection of manure moisture on odor causing volatile organic compounds (VOC‐odor) volatilization from stored swine manure were studied for their ability to predict the volatilization rate (indoor air concentration) and cumulative exposure dose: a MJ‐I model and a MJ‐II model. Both models simulating depletion of source contaminant via volatilization and degradation based on an analytical model adapted from the behavior assessment model of Jury et al. In the MJ‐I model, manure moisture movement was negligible, whereas in the MJ‐II model, time‐dependent indoor air concentrations was a function of constant manure moisture contents and steady‐state moisture advection. Predicted indoor air concentrations and inhaled doses for the study VOC‐odors of p‐cresol, toluene, and p‐xylene varied by up to two to three orders of magnitude depending on the manure moisture conditions. The sensitivity analysis of both models suggests that when manure moisture movement exists, simply MJ‐I model is inherently not sufficient to represent a more generally volatilization process, which can even become stringent as moisture content increases. The conclusion illustrates how one needs to include a wide variety of manure moisture values in order to fully assess the complex volatilization mechanisms that are present in a real situation.  相似文献   

19.
The relationship between particle mass and the number of ambient air particles for the submicrometer size range was examined using a tapered element oscillating microbalance (TEOM) to determine the mass concentration, and a scan-ning mobility particle sizer (SMPS) to determine the volume concentration and total number of particles. The techniques were validated through their application to the estimation of submicrometer particle density for two laboratory generated aerosols of known bulk density (sodium chloride and di-2-ethylhexyl-sebacate). Further evaluation was done with the submicrometer fraction of laboratory generated environmental tobacco smoke (ETS), for which the estimated density of 1.18±0.06 g/cm3 was very close to the previously reported literature value of 1.12 g cm3. Finally, ambient air particles were examined and an estimate of the average submicrometer particle densities for these aerosols was found to vary from 1.2 to 1.8 g cm-3 depending on the time of day. This high variation in the density of the ambient air submicrometer particles, makes it hard to estimate the mass concentration from the SMPS number concentration with better than 60% uncertainty, based on an assumed density value.  相似文献   

20.
Fine particulate matter (PM2.5) air pollution has been linked to adverse health impacts, and combustion sources including residential wood-burning may play an important role in some regions. Recent evidence suggests that indoor air quality may improve in homes where older, non-certified wood stoves are exchanged for lower emissions EPA-certified alternatives. As part of a wood stove exchange program in northern British Columbia, Canada, we sampled outdoor and indoor air at 15 homes during 6-day sampling sessions both before and after non-certified wood stoves were exchanged. During each sampling session two consecutive 3-day PM2.5 samples were collected onto Teflon filters, which were weighed and analyzed for the wood smoke tracer levoglucosan. Residential PM2.5 infiltration efficiencies (Finf) were estimated from continuous light scattering measurements made with nephelometers, and estimates of Finf were used to calculate the outdoor- and indoor-generated contributions to indoor air. There was not a consistent relationship between stove technology and outdoor or indoor concentrations of PM2.5 or levoglucosan. Mean Finf estimates were low and similar during pre- and post-exchange periods (0.32 ± 0.17 and 0.33 ± 0.17, respectively). Indoor sources contributed the majority (~65%) of the indoor PM2.5 concentrations, independent of stove technology, although low indoor-outdoor levoglucosan ratios (median ≤ 0.19) and low indoor PM2.5-levoglucosan correlations (r ≤ 0.19) suggested that wood smoke was not a major indoor PM2.5 source in most of these homes. In summary, despite the potential for extensive wood stove exchange programs to reduce outdoor PM2.5 concentrations in wood smoke-impacted communities, we did not find a consistent relationship between stove technology upgrades and indoor air quality improvements in homes where stoves were exchanged.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号