首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 936 毫秒
1.
为了进一步提高电除尘器的收尘效率,尤其是对高比电阻粉尘的收尘效率,依据非稳态静电收集理论,对影响电除尘器粉尘收集性能各项因素的作用程度及机理进行了进一步研究。实验研究了粉尘收尘效率与不同比电阻粉尘的最优极间距、最优工作电压、粉尘层厚度和比电阻之间的相互关系。研究结果表明,随着极间距的增加,对应比收尘极面积,对于不同比电阻粉尘的收尘效率的增加幅度是不同的,其中高比电阻粉尘的收尘效率增加的趋势更加显著;粉尘比电阻越高,所对应的最优极间距越大,宽间距电除尘器对捕集高比电阻粉尘具有一定优越性;在最优极间距条件下,粉尘比电阻越高,其所对应的最优工作电压越小;相对于正常比电阻粉尘,随极板沉积粉尘层厚度的增加,高比电阻粉尘的最佳收尘效率所对应的最优工作电压升高幅度较大,而且最优工作电压所对应的收尘效率下降显著。随粉尘比电阻的增大,电除尘器收尘效率逐渐降低,特别是当粉尘比电阻大于1011Ω.cm后,粉尘收尘效率显著下降。研究结果与非稳态静电收尘理论提出的观点相吻合,有助于透彻理解电场结构和运行参数与粉尘收集性能的关系,特别是对于今后研发提高高比电阻粉尘收集性能的针对性技术措施具有指导作用。  相似文献   

2.
The object of this program was to study particle collection efficiency in venturi scrubbers in order to account for the effects of particle size and wettability, venturi size, and fluid flow rates. The body of information is directed to those interested in the prediction of particle collection efficiency in venturi scrubbers.  相似文献   

3.
Dust collection efficiency data were analyzed to determine better operating conditions for a two-dimensional circulating granular bed filter (CGBF). The dust collection efficiency in the granular bed was affected by the following operating parameters: the louver angle, the solids mass flow rate, and the particle size of the bed material. Experimental results showed that higher dust collection efficiency occurs when the solids mass flow rates were 20.34 +/- 0.24, 21.50 +/- 0.11, and 30.51 +/- 0.57 g/sec at louver angles of 45 degrees, 30 degrees, and 20 degrees, respectively. Optimal dust collection efficiency peaked with a louver angle of 30 degrees. Average particle sizes of bed material by sieve diameters (microm) of 795 microm had higher dust collection efficiency than the average collector particle size of 1500 microm. Dust collection efficiency is influenced by bed material attrition phenomenon, causing dust collection efficiency to decrease rapidly. The dust collection efficiency analysis not only found the system free of design defects but also assisted in the operation of the two-dimensional CGBF system.  相似文献   

4.
A novel two-stage wet electrostatic precipitator (ESP) has been developed using a carbon brush pre-charger and collection plates with a thin water film. The electrical and particle collection performance was evaluated for submicrometer particles smaller than 0.01- 0.5 micrometer in diameter by varying the voltages applied to the pre-charger and collection plates as well as the polarity of the voltage. The collection efficiency was compared with that calculated by the theoretical models. The long-term performances of the ESP with and without water films were also compared in tests using Japanese Industrial Standards dust. The experimental results show that the carbon brush pre-charger of the two-stage wet ESP had approximately 10% particle capture, while producing ozone concentrations of less than 30 ppb. The produced amounts of ozone are significantly lower than the current limits set by international agencies. The ESP also achieved a high collection rate performance, averaging 90% for ultrafine particles, as based on the particle number concentration at an average velocity of 1 m/sec corresponding to a residence time of 0.17 sec. Higher particle collection efficiency for the ESP can be achieved by increasing the voltages applied to the pre-charger and the collection plates. The decreased collection efficiency that occurred during dust loading without water films was completely avoided by forming a thin water film on the collection plates at a water flow rate of 6.5 L/min/m(2).  相似文献   

5.
Abstract

Dust collection efficiency data were analyzed to determine better operating conditions for a two-dimensional circulating granular bed filter (CGBF). The dust collection efficiency in the granular bed was affected by the following operating parameters: the louver angle, the solids mass flow rate, and the particle size of the bed material. Experimental results showed that higher dust collection efficiency occurs when the solids mass flow rates were 20.34 ± 0.24, 21.50 ± 0.11, and 30.51 ± 0.57 g/sec at louver angles of 45°, 30°, and 20°, respectively. Optimal dust collection efficiency peaked with a louver angle of 30°. Average particle sizes of bed material by sieve diameters (μm) of 795 μm had higher dust collection efficiency than the average collector particle size of 1500 μm. Dust collection efficiency is influenced by bed material attrition phenomenon, causing dust collection efficiency to decrease rapidly. The dust collection efficiency analysis not only found the system free of design defects but also assisted in the operation of the two-dimensional CGBF system.  相似文献   

6.
A modified model of venturi scrubber performance has been developed that addresses two effects of liquid surface tension: its effect on droplet size and its effect on particle penetration into the droplet. The predictions of the model indicate that, in general, collection efficiency increases with a decrease in liquid surface tension, but the range over which this increase is significant depends on the particle size and on the scrubber operating parameters. The predictions further indicate that the increases in collection efficiency are almost totally due to the effect of liquid surface tension on the mean droplet size, and that the collection efficiency is not significantly affected by the ability of the particle to penetrate the droplet.  相似文献   

7.
在研究旋风除尘器内气固两相的运动状况及分离机理方面,计算机模拟替代部分实验的方法能够优化设计旋风除尘器结构参数,提高其对微细颗粒的捕集效率,减少运行压力损失。本研究采用RSM模型和随机轨道模型对旋风除尘器内流场及浓度场进行模拟及实验。研究表明,旋风除尘器压力损失模拟结果与实验结果吻合较好,对于大于5μm的颗粒其捕集效率模拟结果与实验结果基本吻合;旋风除尘器外壁的颗粒浓度呈螺旋带状分布;如将排气管管径减少至原直径0.8倍,可使其对2μm颗粒捕集效率提高6.6%,但压力损失提高36.5%;颗粒的凝并作用有利于提高旋风除尘器微细颗粒的捕集效率。  相似文献   

8.
A large number of pressurized coal gasification processes being developed propose to use venturi scrubbers for particulate removal at high pressures. Theoretical predictions based on venturi scrubber performance models indicate that particle collection efficiency will decrease severely in these high gas pressure applications.

An exploratory theoretical and experimental program was performed to study the effect of gas pressure on venturi scrubber performance. Experiments were done on a 0.47 m3/s (1000 acfm) pilot scale venturi scrubber. Particle collection performance was determined as a function of scrubber pressure drop for venturi scrubbers operating In the range of 1-10 atm total pressure. Experimental results confirmed that the particle collection efficiency of venturi scrubbers decreases for a given scrubber pressure drop as total gas pressure Is increased. To achieve the same particle collection efficiency, the pressure drop across a venturi scrubber operated at 10 atm Is about 10 times that of the same scrubber operated at 1 atm pressure.  相似文献   

9.
Abstract

Particle emissions of modern diesel engines are of a particular interest because of their negative health effects. The special interest is in nanosized solid particles. The effect of an open channel filter on particle emissions of a modern heavy-duty diesel engine (MAN D2066 LF31, model year 2006) was studied. Here, the authors show that the open channel filter made from metal screen efficiently reduced the number of the smallest particles and, notably, the number and mass concentration of soot particles. The filter used in this study reached 78% particle mass reduction over the European Steady Cycle. Considering the size-segregated number concentration reduction, the collection efficiency was over 95% for particles smaller than 10 nm. The diffusion is the dominant collection mechanism in small particle sizes, thus the collection efficiency decreased as particle size increased, attaining 50% at 100 nm. The overall particle number reduction was 66–99%, and for accumulation-mode particles the number concentration reduction was 62–69%, both depending on the engine load.  相似文献   

10.
The suppression of corona by particle space-charge is of considerable importance in electrostatic precipitators dealing with medium to high concentrations of particulates. However, the effect of the dust concentration on collection efficiency has found no direct answer in the literature. In addition to the expected reduction in corona current due to low mobility dust particles, the presence of these charged particles has two other main effects: 1. The electric field in the vicinity of the discharge electrode is weakened and hence the concentration of ions originating in the ionization zone and forming the charging current is decreased. 2. The resulting space-charge build-up causes an increase in the field strength adjacent to the collecting surface of the precipitator. The importance of each of these effects on the collection efficiency will be dependent on the relative decrease in particle charge as compared to the increase in the collection field. Experiments were carried out under both positive and negative corona with aerosol concentrations having specific surfaces in the range 0 to 44 m2/m3. These results showed: 1. For low values of corona current densities, as the specific surface area increases, the efficiency decreases. In this cqse, the charge per particle decreases as the particle concentration increases and becomes far below the normal charge attainable. Here the increase in the collection field is more than counteracted by the jarge reduction in particle charge. 2. For higher values of initial corona current densities, as the particle specific surface area increases, the efficiency either increases slightly or stays constant, in spite of major reductions in the measured corona current. In this case there should also be a reduction in the charge per particle with the increase in particle concentration, however, this is apparently offset by the increase in the collection field strength. Analysis of the results, coupled with an interpretation of existing theories, indicates that a major parameter that must be considered is the ratio of the initial corona current density and the specific surface of the particles.  相似文献   

11.
Electrostatic precipitation is considered as an effective technology for fine particle removal. A lab-scale wet electrostatic precipitator (ESP) with wire-to-plate configuration was developed to study particle migration and collection. The performance of the wet ESP was evaluated in terms of the corona discharge characteristics, total removal efficiency and fractional removal efficiency. The corona discharge characteristics and particle removal abilities of the wet ESP were investigated and compared with dry ESP. Particle removal efficiency was influenced by discharge electrode type, SO2 concentration, specific collection area (SCA) and particle/droplet interaction. Results showed that the particle removal efficiency of wet ESP was elevated to 97.86% from 93.75% of dry ESP. Three types of discharge electrodes were investigated. Higher particle removal efficiency and larger migration velocity could be obtained with fishbone electrode. Particle removal efficiency decreased by 2.87% when SO2 concentration increased from 0 ppm to 43 ppm as a result of the suppression of corona discharge and particle charging. The removal efficiency increased with higher SCA, but it changed by only 0.71% with the SCA increasing from 25.0 m2/(m3/s) to 32.5 m2/(m3/s). Meanwhile, the increasing of particle and droplet concentration was favorable to the particle aggregation and improved particle removal efficiency.

Implications: This work tends to study the particle migration and collection under spraying condition. The performance of a wet electrostatic precipitator (ESP) is evaluated in terms of the corona discharge characteristics, total particle removal efficiency, and fractional particle removal efficiency. The effects of water droplets on particle removal, especially on removal of particles with different sizes, is investigated. The optimization work was done to determine appropriate water consumption, discharge electrode type, and specific collection area, which can provide a basis for wet ESP design and application.  相似文献   


12.
Theoretical calculations and experimental measurements show that the collection of small aerosol particles (0.05 to 5 micron diameter range) by water droplets in spray scrubbers can be substantially increased by electrostatically charging the droplets and particles to opposite polarity. Measurements with a 140 acfm two chamber spray scrubber (7 seconds gas residence time) showed an increase in the overall particle collection efficiency from 68.8% tit uncharged conditions to 93.6% at charged conditions, with a dioctyl phthalate aerosol (1.05 μm particle mass mean diameter and 2.59 geometric standard deviation). The collection efficiency for 0.3 μm particles increased from 35 to 87% when charged. During 1973–1974 a 1000 acfm pilot plant electrostatic scrubber was constructed inside a 40 ft trailer for evaluation on controlling particu-late emissions from pulp mill operations (funded by Northwest Pulp and Paper Association). Field tests performed on the particle emissions exhausting from SO2 absorption towers treating the gases from a magnesium based sulfite recovery boiler have shown particle collection efficiencies ranging from about 60 to 99% by weight, depending on the electrostatic scrubber operating conditions. Energy requirements for the University of Washington electrostatic scrubber are about 0.5 hp/1000 acfm (350 Watts/1000 acfm) including gas pressure drop, water pressure drop, and electrostatic charging of the water spray droplets and the particles.  相似文献   

13.
在离心脉冲静电除尘器研究的基础上 ,进行了离心脉冲静电除尘器内的浓度场的测试分析 ,并得出了在一定入口风速、工作电压、入口粉尘浓度下其颗粒浓度场分布规律及实测回归方程。  相似文献   

14.
Impingers have been employed for collection of biological particles for a long time and the collection efficiency for submicron particles has been well studied for a few impinger models, like the SKC Biosampler and the AGI 30. These efficiency studies have been limited to particles larger than about 15 nm. The aim of this research is to determine the collection efficiency of ultrafine particles (from 3 to 100 nm) of a 25 ml midget impinger. The effect of different collection parameters (particle type, collection fluid volume and type and flow rate) was studied and results are presented here. All results showed minimum collection efficiencies from 3 to 10% at approximately 40–57 nm. Increasing the volume of the collection liquid and flow rate improved the collection efficiency of the impinger.  相似文献   

15.
偶极荷电静电凝并除尘器收尘机理及性能研究   总被引:2,自引:0,他引:2  
提出一种高效去除微细颗粒物的偶极荷电静电凝并除尘装置,其主要由凝并区和收尘区组成.对其凝并收尘机理进行了分析,并对收尘性能进行了实验研究.结果表明,偶极荷电静电凝并系数高于库仑凝并系数;偶极荷电静电凝并除尘器中颗粒的凝并效果好,且在相同的条件下,其对微细颗粒物的除尘效率明显高于普通静电除尘器.  相似文献   

16.
This paper presents an experimental investigation of the effects of impaction substrate designs and material in reducing particle bounce and reentrainment. Particle collection without coating by using combinations of different impaction substrate designs and surface materials was conducted using a personal particle sampler (PPS) developed by the University of Southern California. The PPS operates at flow rate of 4 l min-1 with a 50% cutpoint of approximately 0.9 μm in aerodynamic diameter. The laboratory results showed that the PPS collection efficiency for particles larger than 50% cutpoint is strikingly low (e.g., less than 50%) when an uncoated open cavity made of aluminum was used as an impaction substrate. The collection efficiency gradually increased when Teflon tape, Nuclepore, and glass fiber filters were used as impaction surfaces, respectively. Conical or partially enclosed cavity substrate designs increased collection efficiency of particles of 9 μm up to 80–90%. A conical cavity with glass fiber filter used as impaction surface was identified as the optimum configuration, resulting in a collection efficiency of 92% at Stokes numbers as high as 15.4 (corresponding to 9 μm in aerodynamic diameter). Particle losses were low (less than 10%) and relatively independent of particle size in any design with glass fiber filter. Losses seemed to increase slightly with particle size in all other configurations. Finally, outdoor PM1 concentrations obtained with the PPS (in its optimum configuration) and a modified micro-orifice uniform deposit impactor (MOUDI) with coated impaction stages were in excellent agreement. The mean ratio of the PPS-to-MOUDI concentration was 1.13(±0.17) with a correlation coefficient R2=0.95. Results from this investigation can be readily applied to design particle bounce-free impaction substrates without the use of coating. This is a very important feature of impactors, especially when chemical analysis of the collected particulate matter is desirable.  相似文献   

17.
The application of air pollution control devices requires the prediction of overall collection efficiency from the particle size distribution of the dust and the fractional efficiency of the air pollution control device. The cumulative particle size distribution of dust resulting from industrial processes can usually be represented by a straight line on logarithmic probability paper or a log normal function. The fractional efficiency curves of many air pollution control devices such as cyclones or wet scrubbers can also be adequately represented by a log normal function. Only two parameters are required to define a log normal function, a median diameter and a geometric standard deviation. Both of these can easily be obtained from a plot on logarithmic probability paper. The overall collection efficiency has been found to be Very simply related to the four parameters required to define the log normal functions representing the particle size distribution and the collector fractional efficiency. These four parameters are: the mass median diameter and the geometric standard deviation of the dust size distribution, the cut diameter (50% efficiency diameter), and geometric standard deviation of collector fractional efficiency curve. Using this relationship the prediction of overall collection efficiency is greatly simplified with no loss of accuracy.  相似文献   

18.
This investigation numerically examined the cutoff aerodynamic diameter (da50) and the sharpness (GSD) of the particle collection efficiency curve of impactors with a finite impaction plate diameter. Results revealed that the inertial impactors have a limited cutoff aerodynamic diameter at different air velocities. The extreme value of the cutoff aerodynamic diameter increases with the nozzle diameter (W)/the plate diameter (Dc). The computed da50/Dc values of the impactors increase with W/Dc at various Reynolds numbers (Re) and with the nozzle-toplate distance (S)/Dc when Re is 100. The value of GSD slightly increases with W/Dc for Re of 10 and 100, although the effect of S/Dc on GSD is not evident at various Res. The particle collection efficiency curve of the impactor with a lower Re is less sharp than that with a high Re at various W/Dc and S/Dc values. Statistical equations closely fitted the obtained numerical results for Res of 10-3000. The equations are useful for directly calculating the cutoff aerodynamic diameter and the sharpness of the particle collection efficiency curve for single round-nozzle impactors with a finite impaction Dc.  相似文献   

19.
Compliance with sulfur oxides standards will in many cases result in the installation of scrubbing devices. If these devices operate on an effluent gas stream containing particulate as well as sulfur oxides, simultaneous removal would be expected. Since effective simultaneous removal of particulate matter and sulfur oxides is economically desirable, it is of considerable import to characterize scrubber designs being considered as sulfur oxide absorbers as particulate control devices; especially, for fine particulate control.

Data on the fine particle collection efficiency of sulfur oxides scrubbers at two power generating stations is presented. At the first, a venturi and a turbulent contacting absorber (TCA) both with capacities of 30,000 cfm were tested. At the second, a venturi with 600,000 scfm capacity was tested. Fine particle collection efficiency was determined at three pressure drops for the TCA using a cascade impactor. Results for the TCA show high removal efficiencies. It collected more than 90% of submicron particles when the pressure drop was nearly 10 in. H20. The overall particulate removal in the TCA scrubber as determined by modified method 5 or by Brink impactor was greater than 99% when the pressure drop was greater than 6 in. H20. For both the venturi scrubber at the Shawnee Steam Plant and that at the Mystic Power Station, the collection efficiency decreased rapidly with decreasing particle size in the fine particle region.  相似文献   

20.
Environmental Science and Pollution Research - Semi-volatile organic compounds were monitored over a whole year, by collection of gas and particle phases every sixth day at a suburban site in...  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号