首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Use of vent-free gas heating appliances for supplemental heating in U.S. homes is increasing. However, there is currently a lack of information on the potential impact of these appliances on indoor air quality for homes constructed according to energy-efficient and green building standards. A probabilistic analysis was conducted to estimate the impact of vent-free gas heating appliances on indoor air concentrations of carbon monoxide (CO), nitrogen dioxide (NO2), carbon dioxide (CO2), water vapor, and oxygen in “tight” energy-efficient homes in the United States. A total of 20,000 simulations were conducted for each Department of Energy (DOE) heating region to capture a wide range of home sizes, appliance features, and conditions, by varying a number of parameters, e.g., room volume, house volume, outdoor humidity, air exchange rates, appliance input rates (Btu/hr), and house heat loss factors. Predicted airborne levels of CO were below the U.S. Environmental Protection Agency (EPA) standard of 9 ppm for all modeled cases. The airborne concentrations of NO2 were below the U.S. Consumer Product Safety Commission (CPSC) guideline of 0.3 ppm and the Health Canada benchmark of 0.25 ppm in all cases and were below the World Health Organization (WHO) standard of 0.11 ppm in 99–100% of all cases. Predicted levels of CO2 were below the Health Canada standard of 3500 ppm for all simulated cases. Oxygen levels in the room of vent-free heating appliance use were not significantly reduced. The great majority of cases in all DOE regions were associated with relative humidity (RH) levels from all indoor water vapor sources that were less than the EPA-recommended 70% RH maximum to avoid active mold and mildew growth. The conclusion of this investigation is that when installed in accordance with the manufacturer’s instructions, vent-free gas heating appliances maintain acceptable indoor air quality in tight energy-efficient homes, as defined by the standards referenced in this report.

Implications: Probabilistic modeling of indoor air concentrations of carbon monoxide (CO), nitrogen dioxide (NO2), carbon dioxide (CO2), water vapor, and oxygen associated with use of vent-free gas heating appliances provides new data indicating that uses of these devices are consistent with acceptable indoor air quality in “tight” energy-efficient homes in the United States. This study will provide authoritative bodies such as the International Code Council with definitive information that will assist in the development of future versions of national building codes, and will provide evaluation of the performance of unvented gas heating products in energy conservation homes.  相似文献   


2.
Abstract

The two primary factors influencing ambient air pollutant concentrations are emission rate and dispersion rate. Gaussian dispersion modeling studies for odors, and often other air pollutants, vary dispersion rates using hourly meteorological data. However, emission rates are typically held constant, based on one measured value. Using constant emission rates can be especially inaccurate for open liquid area sources, like wastewater treatment plant units, which have greater emissions during warmer weather, when volatilization and biological activity increase. If emission rates for a wastewater odor study are measured on a cooler day and input directly into a dispersion model as constant values, odor impact will likely be underestimated. Unfortunately, because of project schedules, not all emissions sampling from open liquid area sources can be conducted under worst-case summertime conditions. To address this problem, this paper presents a method of varying emission rates based on temperature and time of the day to predict worst-case emissions. Emissions are varied as a linear function of temperature, according to Henry’s law, and a tenth order polynomial function of time. Equation coefficients are developed for a specific area source using concentration and temperature measurements, captured over a multiday period using a data-logging monitor. As a test case, time/temperature concentration correlation coefficients were estimated from field measurements of hydrogen sulfide (H2S) at the Rowlett Creek Wastewater Treatment Plant in Garland, TX. The correlations were then used to scale a flux chamber emission rate measurement according to hourly readings of time and temperature, to create an hourly emission rate file for input to the dispersion model ISCST3. ISCST3 was then used to predict hourly atmospheric concentrations of H2S. With emission rates varying hourly, ISCST3 predicted 384 acres of odor impact, compared with 103 acres for constant emissions. Because field sampling had been conducted on relatively cool days (85–90 °F), the constant emission rate underestimated odor impact significantly (by 73%).  相似文献   

3.
This paper characterizes the emission rates of size fractionated particulate matter, inorganic aerosols, acid gases, ammonia and methane measured over four flocks at a commercial broiler chicken facility. Mean emission rates of each pollutant, along with sampling notes, were reported in this paper, the first in a series of two. Sampling notes were needed because inherent gaps in data may bias the mean emission rates.The mean emission rates of PM10 and PM2.5 were 5.0 and 0.78 g day?1 [Animal Unit, AU]?1, respectively, while inorganic aerosols mean emission rates ranged from 0.15 to 0.46 g day?1 AU?1 depending on the season. The average total acid gas emission rate was 0.43 g day?1 AU?1 with the greatest contribution from nitrous and nitric acids and little contribution from sulfuric acid (as SO2).Ammonia emissions were seasonally dependent, with a mean emission rate of 66.0 g day?1 AU?1 in the cooler seasons and 94.5 g day?1 AU?1 during the warmer seasons. Methane emissions were relatively consistent with a mean emission rate of 208 g day?1 AU?1.The diurnal pattern in each pollutant’s emission rate was relatively consistent after normalizing the hourly emissions according to each daily mean emission rate. Over the duration of a production cycle, all the measured pollutants’ emissions increased proportionally to the total live mass of birds in the house, with the exception of ammonia.Interrelationships between pollutants provide evidence of mutually dependent release mechanisms, which suggests that it may be possible to fill data gaps with minimal data requirements. In the second paper (Roumeliotis, T.S., Dixon, B.J., Van Heyst, B.J. Characterization of gaseous pollutants and particulate matter emission rates from a commercial broiler operation part II: correlated emission rates. Atmospheric Environment, 2010.), regression correlations are developed to estimate daily mean emission rates for data gaps and, using the normalized hourly diurnal patterns from this paper, emission factors were generated for each pollutant.  相似文献   

4.
单波  陈杰  肖岩 《环境工程学报》2013,7(2):649-656
胶合竹材GluBam的甲醛释放情况是现代竹结构住宅环保性的一个重要方面,也是竹结构住宅推广中最受关注的指标之一。采用1 m3气候箱对温度、相对湿度和封边情况与GluBam的甲醛释放量和释放速率的相关关系进行了测试,并以一阶单衰减模型为基础提出了GluBam的甲醛释放分析模型。测试和分析结果表明:GluBam板材在各模拟条件下甲醛浓度峰值均小于规范要求;初始甲醛释放量E0和衰减率常数k可以用来评价GluBam的甲醛释放特征;GluBam的醛释放量和释放速率随环境温度和湿度增加而显著增大,且温度因素的影响更大;封边处理可以有效降低GluBam板材的甲醛释放量。  相似文献   

5.

Wastewater treatment plants (WWTPs) have been recognized as important sources for anthropogenic greenhouse gas (GHG) emission. The objective of the study was to thoroughly investigate a typical industrial WWTP in southern Taiwan in winter and summer which possesses the emission factors close to those reported values, with the analyses of emission factors, mass fluxes, fugacity, lab-scale in situ experiments, and impact assessment. The activated sludge was the important source in winter and summer, and nitrous oxide (N2O) was the main contributor (e.g., 57 to 91 % of total GHG emission in a unit of kg carbon dioxide-equivalent/kg chemical oxygen demand). Albeit important for the GHGs in the atmosphere, the fractional contribution of the GHG emission to the carbon or nitrogen removal in wastewater treatment was negligible (e.g., less than 1.5 %). In comparison with the sludge concentration or retention time, adjusting the aeration rate was more effective to diminish the GHG emission in the activated sludge without significantly affecting the treated water quality. When the aeration rate in the activated sludge simulation was reduced by 75 %, the mass flux of N2O could be diminished by up to 53 % (from 9.6 to 4.5 mg/m2-day). The total emission in the WWTP (including carbon dioxide, methane, and N2O) would decrease by 46 % (from 0.67 to 0.36 kg CO2-equiv/kg COD). However, the more important benefit of changing the aeration rate was lowering the energy consumption in operation of the WWTP, as the fractional contribution of pumping to the total emission from the WWTP ranged from 46 to 93 % within the range of the aeration rate tested. Under the circumstance in which reducing the burden of climate change is a global campaign, the findings provide insight regarding the GHG emission from treatment of industrial wastewater and the associated impact on the treatment performance and possible mitigation strategies by operational modifications.

  相似文献   

6.
ABSTRACT

Gaseous chlorine dioxide (ClO2) is one of the most promising air disinfectants. In this study, an ultra-low concentration of ClO2 gas (< 1.2 mg/m3) was generated in an office at various levels of humidity and illuminance to investigate the decay law. The disinfection efficiency and metal corrosiveness of ultra-low concentrations of ClO2 gas were also studied using an experimental chamber. At 48% and 75% humidity, the decay rate constants of ClO2 gas were 0.0034 min?1 and 0.0036 min?1, respectively. The rate of decline of the ClO2 concentration increased as the humidity of the environment increased. The decay rate constant of ClO2 gas at an illuminance of 76 lux and 3429 lux was 0.0034 min?1 and 0.00427 min?1, respectively; hence, the decay rate increased with increased illumination. At a humidity of 72% and illuminance of 2112 lux, the decay rate constant reached 0.00880 min?1. The effects of humidity and illuminance on the attenuation of the ClO2 concentration were strongly synergistic. When the gas concentration was maintained below 0.9 mg/m3, the disinfection rate of ClO2 on bacteria (P. aeruginosa, V. mimicus and S. aureus) exceeded 99.9%; thus, ClO2 gas exhibited a high disinfection efficiency. In addition, there was no corrosion to various metals by ClO2 under the same conditions. Consequently, gaseous ClO2 at ultra-low concentrations has a high sterilization efficiency and is non-corrosive to metals.  相似文献   

7.
The method and example results for the determination of organic air emissions from a common indoor material are presented. A well instrumented and characterized 0.166-m3 stainless steel test chamber is used to ventilate sample materials at controlled air change rates, temperature and relative humidity. The test chamber outlet air stream is sampled using Tenax® (1.6g) filled glass cartridges. The Tenax® sample cartridges are then thermally desorbed for further concentration onto a Nutech® model 8528 purge and trap system and desorption to a packed column gas Chromatograph for analysis. Organic emissions are quantified on a species specific basis and total organics basis. Test chamber concentrations of total organics for a waterbased adhesive are observed to diminish with time. Calculated emission rates for the floor adhesive were determined to be 95μg g−1 h−1 after ventilation at 1.77 air changes per hour for 10 h and 259 μg g−1 h−1 after 24-h ventilation at 3.6 air changes per hour.  相似文献   

8.
Unvented combustion sources in indoor environments generate emissions that contribute to indoor air pollution. Both the direct and mass-balance methods have been used to measure emission rates from these sources in field houses, test houses and chambers. In particular, emission rates have been obtained for pollutants from kerosene space heaters and from unvented gas appliances such as range-top burners, ovens, dryers and gas space heaters.Most studies have focused on the emission rates of the inorganic air constituents (NO, NO2, CO and a few others). This paper compares the two methods of emission rate measurement, and summarizes the emission rates of NO, NO2 and CO from range-top burners.The emission rates of NO, NO2 and CO from range-top burners are well quantified, but vary widely as a function of the source condition. The experiments described herein found that the two methods provide comparable emission rates. Consequently, in support of the research needed to establish the distribution of emission rates from range-top burners in the U.S. housing stock, the method to be employed should be the one that provides the required information cost effectively.  相似文献   

9.
The controlled atmosphere aspects of the environmental chambers at the University of Utah are described. Control of wind velocity, CO2, concentration, temperature, relative humidity, and pollutant concentration are discussed. Requirements of our research program dictating the chamber design include: (1) ability to expose plants to air pollutants under the same environmental conditions at different times; (2) ability to simulate field environmental conditions within acceptable limits; (3) ability to study the effects of temperature, light, relative humidity, and wind velocity on response of plants to air pollutants; (4) ability to measure growth suppression, respiration, and transpiration; and (5) ability to measure the pollutant uptake rate of the plants.  相似文献   

10.
ABSTRACT

Pig production systems in China are shifting from small to industrial scale. Significant variation in housing ammonia (NH3) emissions can exist due to differences in diet, housing design, and management practices. However, there is a knowledge gap regarding the impacts of farm-scale in China, which may be critical in identifying hotspots and mitigation targets. Here, continuous in-situ NH3 concentration measurements were made at pig farms of different scales for sows and fattening pigs over periods of 3–6 days during two different seasons (summer vs. winter). For the sow farms, NH3 emission rates were greater at the small farm (summer: 0.52 g pig?1 hr?1; winter: 0.21 g pig?1 hr?1) than at the large farm (summer: 0.34 g pig?1 hr?1; winter: 0.12 g pig?1 hr?1). For the fattening pig farms, NH3 emission rates were greater at the large farm (summer: 0.22 g pig?1 hr?1; winter: 0.16 g pig?1 hr?1) than at the small farm (summer: 0.19 g pig?1 hr?1; winter: 0.07 g pig?1 hr?1). Regardless of farm scale, the NH3 emission rates measured in summer were greater than those in winter; the NH3 emission rates were greater in the daytime than at the nighttime; a positive relationship (R2 = 0.06–0.68) was established between temperature and NH3 emission rate, whereas a negative relationship (R2 = 0.10–0.47) was found between relative humidity and NH3 emission rate. The effect of farm-scale on indoor NH3 concentration could mostly be explained by the differences in ventilation rates between farms. The diurnal variation in NH3 concentration could be partly explained by ventilation rate (R2 = 0.48–0.78) in the small traditional farms and by emission rate (R2 = 0.26–0.85) in the large industrial farms, except for the large fattening pig farm in summer. Overall, mitigation of NH3 emissions from sow farms should be a top priority in the North China Plain.

Implications: The present study firstly examined the farm-scale effect of ammonia emissions in the North China Plain. Of all farms, the sow farm was identified as the greatest source of ammonia emission. Regardless of farm scale, ammonia emission rates were observed to be higher in summer. Ammonia concentrations were mostly higher in the large industrial farms partly due to lower ventilation rates than in the small traditional farms.  相似文献   

11.
The surface emission of landfill gas (LFG) was studied to estimate the amount of LFG efflux from solid waste landfills using an air flux chamber. LFG efflux increased as atmospheric temperature increased during the day, and the same pattern for the surface emission was observed for the change of seasons. LFG efflux rate decreased from summer through winter. The average LFG efflux rates of winter, spring and summer were 0.1584, 0.3013 and 0.8597 m3 m−2 h−1 respectively. The total amount of surface emission was calculated based on the seasonal LFG efflux rate and the landfill surface area. From the estimates of LFG generation, it is expected that about 30% of the generated LFG may be released through the surface without extraction process. As forced extraction with a blower proceeded, the extraction well pressure decreased from 1100 to –100 mm H2O, and the LFG surface efflux decreased markedly above 80%. Thus, the utilization of LFG by forced extraction would be the good solution for global warming and air pollution by LFG.  相似文献   

12.
曝气对潜流人工湿地污染物沿程降解规律的影响   总被引:1,自引:0,他引:1  
通过构建曝气及未曝气潜流人工湿地小试实验系统,研究曝气对人工湿地床体中污染物沿程变化规律的影响。实验结果表明,曝气对污染物沿程降解规律的影响与污染物种类有关,在净化COD和氨氮时,曝气人工湿地污染物主要以水平推流式降解为主,未曝气系统床体中则出现分层现象,深度为40 cm以上的床体区域中污染物以水平推流式降解为主,40 cm以下区域则以垂直梯度降解方式为主。对于磷来说,两对比系统均以水平推流降解方式为主,但不同深度上的降解速率有所差异,曝气系统30~50 cm的床体中间层降解速率较快,而未曝气系统50 cm以下的床体底层降解速率较快。将对比系统总体净化效果进一步比较发现,对于COD的去除来说,温度的影响大些,而对于氨氮和TP的去除来说,曝气的影响则更为显著。  相似文献   

13.
Direct emissions and emission of precursor compounds of acetic and formic acid from higher plants are a significant source of these acids in the atmosphere. To travel from the plant cell to the atmosphere, a gas molecule must first leave the liquid phase and then enter the internal leaf gas phase. The apoplast (cell wall) is the last barrier before the molecule can escape through the stomata. During field experiments we monitored the gas exchange (H2O, CO2, organic acids) of Quercus ilex L. leaves. The exchange rates of acetic and formic acid under field conditions followed a typical diurnal pattern and ranged between −10 (uptake) and 52 (emission) nmol m-2 leaf area min-1 with the maximum around noon. Growth chamber experiments indicate that the emission is related to the stomatal conductance. We discussed the exchange rate of organic acids between the cell wall and the atmosphere in connection with Henry’s law, and the physicochemical conditions in the cell wall. The evaluation showed that for apoplastic pH values between 4 and 5, 26–130% of the measured acetic acid emission based on leaf area could be predicted.  相似文献   

14.
Emission rates of ammonia, acid gases, inorganic aerosols, methane, and size fractionated particulate matter were measured from a commercial broiler facility. This paper discusses the statistically influential parameters on numerous pollutants’ emission from a broiler chicken facility and generates emission correlations to fill data gaps and develop averaged emission factors.Live mass of the birds was commonly a significant variable to each pollutant’s emission. Some variables significantly impacted the pollutants’ emissions, such as litter moisture content, but were measured discretely and cannot be used for filling in data gaps.House parameter correlations were, therefore, developed using parameters measured at the facility, such as indoor temperature, relative humidity, and the live mass of the birds, and relied on the mutual behaviour of discretely measured explanatory parameters and continuously monitored confounding variables. The live mass and the difference in the indoor temperature and the house set-point temperature were the most significant variables in each pollutant’s correlation.The correlations predicted each pollutants emission to within 20% (total mass basis) over most broiler production cycles. Their validation on independent datasets also successfully estimated the flocks’ emissions to within 3%.Emission factors (EFs) were developed for methane, ammonia, and size fractionated particulate matter using measured data and correlated emissions to fill in data gaps. PM10 (particulate matter ≤10 microns) EFs were estimated to be 4.6 and 5.9 g d?1 [Animal Unit, AU]?1 for five and six week production cycles, respectively. PM2.5 (PM ≤ 2.5 microns) EFs were 0.8 and 1.4 g d?1 AU?1 for five and six week cycles, respectively. Ammonia and methane emission factors were estimated at 120.8 and 197.0 g d?1 AU?1, respectively for a five week production cycle.  相似文献   

15.
Municipal solid waste management (MSWM) is an important environmental challenge and subject in urban planning. A sustainable MSWM strategy should consider not only economic efficiency but also life-cycle assessment of environmental impact. This study employs the fuzzy multiobjective linear programming (FMOLP) technique to find the optimal compromise between economic optimization and pollutant emission reduction for the MSWM strategy. Taichung City in Taiwan is evaluated as a case study. The results indicate that the optimal compromise MSWM strategy can reduce significant amounts of pollutant emissions and still achieve positive net profits. Minimization of the sulfur oxide (SOx) and nitrogen oxide (NOx) emissions are the two major priorities in achieving this optimal compromise strategy when recyclables recovery rate is lower; however, minimization of the carbon monoxide (CO) and particulate matter (PM) emissions become priority factors when recovery rate is higher.

Implications: This paper applied the multiobjective optimization model to find the optimal compromise municipal solid waste management (MSWM) strategy, which minimizes both life-cycle operating cost and air pollutant emissions, and also to analyze the correlation between recyclables recovery rates and optimal compromise strategies. It is different from past studies, which only consider economic optimization or environmental impacts of the MSWM system. The result shows that optimal compromise MSWM strategy can achieve a net profit and reduce air pollution emission. In addition, scenario investigation of recyclables recovery rates indicates that resource recycling is beneficial for both economic optimization and air pollutant emission minimization.  相似文献   

16.
Since emission regulations in Korea concentrate mainly on the limitation of pollutant concentration in the stack gas, it is difficult to achieve a desirable air quality in a heavily industralized city like Ulsan. To ensure a suitable air quality in the future, a total emission control method is proposed with a stack height formula of H = 10.6 q0.5, where H is the stack height (m) and q is the SO2 emission rate (m3 h−1 reduced to 0°C). The total emission permitted can be allocated to industries
  • 1.(1) at an uniform reduction rate,
  • 2.(2) by the formula Q = aQo0.925, where Q is the emission allowed (g s−1), a is a constant, and Qo is the emission before control (g s−1), or
  • 3.(3) by using a linear programming technique.
The above three approaches were evaluated using the TCM 2 air quality model. In order to achieve the air quality goal set for the area, the first approach requires 38.7 % reduction of SO2 emission from industries, the second 53.3 %, and the third 4.3 %. The linear programming method is found to be very economical, but there are some administrative difficulties in enforcement.  相似文献   

17.
孔口分布及空气流速对充氧性能的影响   总被引:1,自引:0,他引:1  
实验采用鼓风曝气,改变曝气量,研究孔口分布及空气流速对清水充氧性能的影响。通过考察氧总转移系数KLa(20)、充氧能力N0和氧转移效率E3项指标,得出该曝气设备的最佳运行条件:在曝气量为9 m3/h时,选用曝气器B进行曝气。这样可以得到较高的KLa(20)(1.816 h-1)、N0(0.105 kg/h)和E(4.151%),为曝气设备的实际应用提供参考。  相似文献   

18.
Abstract

There is a dearth of information on dust emissions from sources that are unique to the U.S. Department of Defense testing and training activities. However, accurate emissions factors are needed for these sources so that military installations can prepare accurate particulate matter (PM) emission inventories. One such source, coarse and fine PM (PM10 and PM2.5) emissions from artillery backblast testing on improved gun positions, was characterized at the Yuma Proving Ground near Yuma, AZ, in October 2005. Fugitive emissions are created by the shockwave from artillery pieces, which ejects dust from the surface on which the artillery is resting. Other contributions of PM can be attributed to the combustion of the propellants. For a 155–mm howitzer firing a range of propellant charges or zones, amounts of emitted PM10 ranged from ~19 g of PM10 per firing event for a zone 1 charge to 92 g of PM10 per firing event for a zone 5. The corresponding rates for PM2.5 were ~9 g of PM2.5 and 49 g of PM2.5 per firing. The average measured emission rates for PM10 and PM2.5 appear to scale with the zone charge value. The measurements show that the estimated annual contributions of PM10 (52.2 t) and PM2.5 (28.5 t) from artillery backblast are insignificant in the context of the 2002 U.S. Environment Protection Agency (EPA) PM emission inventory. Using national–level activity data for artillery fire, the most conservative estimate is that backblast would contribute the equivalent of 5 x 10–4% and 1.6 x 10–3% of the annual total PM10 and PM2.5 fugitive dust contributions, respectively, based on 2002 EPA inventory data.  相似文献   

19.
Concentration profiles for hydrogen fluoride(HF), sulfur dioxide(SO2), ozone (O3), nitrogen dioxide(NO2), and nitric oxide(NO) generated in a standardized alfalfa canopy are presented. Wind, light, temperature, and carbon dioxide(CO2) profiles, canopy pollutant uptake rates, and canopy structural data are also given. Canopy pollutant concentration profile characteristics were studied to evaluate the relative potentials for major air pollutants to penetrate into canopies. The study was conducted in an environmental growth chamber equipped to control automatically environmental conditions and monitor continuously gas exchange rates. HF, SO2, and NO2 profiles suggested that these gases were removed efficiently by the upper portion of the canopy as well as by the immediate subsurface vegetation. The steady state HF profile showed the greatest displacement within the canopy. The NO profile was displaced the least. The uptake rate of NO by plants was apparently too slow in comparison with gas transport and mixing within the canopy to affect the internal profile substantially. O3 appeared to be readily deposited on the surface tissues, but the deeper tissues in the canopy had less effect on the concentration profile. Data are also presented to show the relationship between NO2 concentration within the canopy and changes in the air concentration above the vegetation. The results indicated that gas transport between the atmosphere and canopy interior was rapid. The data presented should be of current interest to agriculturists, researchers, administrators, and environmental planners concerned with effects of air pollutants on plants and on the fate of pollutants in the microenvironment.  相似文献   

20.

Ammonia emission during composting results in anthropogenic odor nuisance and reduces the agronomic value of the compost due to the loss of nitrogen. Adjusting the operating parameters during composting is an emerging in situ odor control technique that is cheap and highly efficient. The effects of in situ NH3 emission control were investigated in this study by simultaneously adjusting key operating parameters (such as C/N ratio, aeration rate, and moisture content) during the composting processes (C1–C9). Results showed that the average NH3 emission concentrations for different treatments were in the order of C1 > C4 > C2 > C5 > C3 > C6 > C7 > C8 > C9. The total content of NH3 emission (21.02 g/kg) in C9 (C/N ratio = 35, aeration rate = 15 L/min, and moisture content = 60%) was much lower than that (65.95 g/kg) in C1 (C/N ratio = 15, aeration rate = 5 L/min, and moisture content = 60%). The nitrogen loss ratio was 27.36% for C1, while 16.15% for C9. The microbial diversity and abundance in C9 and C1 were compared using high-throughput sequencing. The relationship between NH3 emission, operating parameters, and the related functional microbial communities was also investigated. Results revealed that Nitrosospira, Nitrosomonas, Nitrobacter, Pseudomonas, Methanosaeta, Rhodobacter, Paracoccus, and Sphingobacterium were negatively related to NH3 emission. According to the above results, the optimal values for different operating parameters for the in situ NH3 control during kitchen waste composting were, respectively, moisture content of 70%, C/N ratio of 35, and aeration rate of 15 L/min, with the order of effectiveness from high to low being aeration rate > C/N > moisture. This information could be used as a valuable reference for the in situ NH3 emission control during kitchen waste composting.

  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号