1.
Pulse-jet fabric filters rely on the filtration of dirty flue gas by the outside surface of the bags, which are then cleaned by a shock wave generated by an air pulse entering each bag from the top. As it travels down the length of the bag, the shock wave flexes the fabric and dislodges the dust cake. Enhancement of the pulse may be achieved by using a venturi, and cleaning may be on-line or off-line. This paper summarizes the results of an exhaustive study conducted for the Electric Power Research Institute to provide a convenient and versatile information base about the use of pulse-jet fabric filters on coal-fired boilers. Predominant features of the many pulse-jet installations identified by vendor survey and literature survey are shown in graphical and tabular form.  相似文献   

2.
Stringent particulate emissions limits and increasing awareness of stack opacity is leading the utility industry to use high efficiency particulate control systems. In response to this trend, the Electric Power Research Institute (EPRI) is conducting several research programs aimed at improving the operation, maintenance and performance of particulate control systems. One of these programs, RP-1401, “Reliability Assessment of Particulate Control Systems,” is developing operation, maintenance and design data bases for both electrostatic precipitators and fabric filters. This paper discusses some of the intermediate findings of the work done on fabric filters.  相似文献   

3.
Compliance with particulate standards for utility boilers burning low sulfur western coal has resulted in the installation and proposed installation of several fabric filter collectors where cold or hot electrostatic precipitators would have traditionally been applied. Recently, SO3 conditioning has been used to improve cold precipitator performance resulting in considerable reduction in specific collection area (SCA). All this suggests that trade-offs exist indicating ranges of SCA, A/C ratio, and power plant size (Mw) where fabric filters become competitive with electrostatic precipitators. Conceptual cost models are presented which indicate total capital investment and annual costs for the control devices. Precipitator costs are correlated with collecting area, gas flow rate, and power input and are presented as functions of SCA and Mw. Fabric filter costs are keyed to gross filter area, pressure drop, and gas flow rate. Fabric filters become competitive when a cold precipitator requires SCAs in excess of 600 to 800 and competitive when a hot precipitator requires equivalent cold precipitator SCAs in excess of 600 to 1000 depending on A/C ratio, Mw, and hot precipitator SCA credit allowance. The S03 conditioned precipitator scenario is shown to be economically competitive with fabric filters.  相似文献   

4.
New kinds of fabric filtration devices are reviewed in this paper. The industry is on the threshold of a period of innovation and development in this field which should see the advancement of new concepts of the way filters function.  相似文献   

5.
Some of the features of the fluidized-bed combustion (FBC) process have a direct bearing on the particulate properties that most strongly influence filtering pressure drop. A laboratory program was conducted to experimentally determine the relative pressure drop characteristics of ashes from the TVA-EPRI 20-MW bubbling bed, atmospheric pressure FBC (AFBC) pilot plant and six pulverized-coal combustion (PC) units. The combined influences of measured particle and dust cake properties on filtering pressure drop were estimated with existing filtration theories. These theories predict a higher pressure drop for a dust cake produced with the AFBC ash than for one consisting of any of the PC ashes. Laboratory measurements were made of the flow resistance of idealized, simulated dust cakes to confirm these predictions. Field operating data from the fabric filters collecting some of the tested ashes were available to validate the laboratory results. The laboratory and field data show relatively good agreement. The AFBC ash must be treated as a special case for fabric filters, and careful selection of cleaning method and fabric must be made to minimize the inherently high pressure drop characteristics of this ash.  相似文献   

6.
Performance data for fabric filters using either woven or felt bags can be better understood when fault processes such as pinhole bypass and seepage are considered. Penetration straight through the dust cake and fabric may not be important by comparison. Observed trends of increased penetration with increased filtration velocity, constant or slightly increased penetration with increasing particle diameter, and constant penetration with additional dust loading can be explained by fault processes. The pulse-jet experimental work described here, done over many filtration and cleaning cycles, shows that penetration increases substantially with increasing filtration velocity and that this increase is due entirely to seepage.  相似文献   

7.
This paper summarizes information and results presented at the Third Conference on Fabric Filter Technology for Coal-Fired Power Plants held November 19-21, 1985 in Scottsdale, Arizona. Sponsored by the Electric Power Research Institute (EPRI), in cooperation with the Arizona Public Service Co. and Salt River Project, the conference focused on recent technological developments in the design and operation of fabric filters (baghouses) in electric utility settings. Papers were presented by individuals representing utilities, fabric filter manufacturers, research and development organizations, and regulatory agencies. Approximately 200 individuals attended the sessions. Summaries of the first two conferences and results of other fabric Biter research sponsored bv EPRI have been published previously in JAPCA.1–9  相似文献   

8.
Closing Comments     
“Industrial fabric filtration, the sleeping giant, is stirring. It appears that we are about to experience a new period of innovation and development similar to the one that occurred during the 1950’s.” The above remarks by Professor First, as presented in the Symposium, unerscore the renewed interest in filtration as a means for controlling submicron particulate emissions. Bur-chard and others pointed out the significance of fine particulate emissions, especially with regard to health effects and visibility degradation, and Walsh discussed the data required to employ fabric filters appropriately for particulate emission control.  相似文献   

9.
The analysis of pressure loss characteristics for pulse jet filters suggests that the relationship between dust adhesion to the fabric and the opposing force generated by pulse jet action plays a major role in dust removal. Hence, fabric cleanability is examined in terms of the adhesion-cohesion forces bonding the dust to the fabric vs. the intensity and frequency of the dust dislodgement forces produced by the high energy air pulses. The effect of jet size and location, jet air volume, and the intensity (pressure) and duration of the jet pulses is related to operating pressure loss.

The mechanics of energy transfer from the jet pulse to the dustladen fabric are explored in terms of jet pressure, solenoid valve action, the ratio of delivered pulse air volume to bag (tube) volume, and the elastic and flex properties of the felt bags. Effective and actual fabric dust holdings before and after cleaning are discussed with respect to steady-state dust deposition and removal rates, and operating pressure losses. Finally, predictive equations are proposed for estimating pressure loss over a broad range of design and operating parameters.  相似文献   

10.
Encouraged by the successes attained with fly ash control by fabric filters in Pennsylvania Power & Light and Colorado Ute, other utilities are installing, planning, and/or considering baghouses as a practical and economical means for controlling emissions from the burning of low sulfur coals. Where deposits of alkaline reagents (i.e. nahcolite) are available, some power plants are also considering a process for dry scrubbing SO2 from the flue gas. By introducing such reagents with the emission ahead of the fabric collector, both partlculates and SO2 are removed.  相似文献   

11.
Operation and maintenance and performing correct system monitoring of fabric filters is discussed. The anticipation of future problems at the time of start-up and the necessity of maintaining correct records on the system to assist in later troubleshooting is stressed. When all is going well, the fabric filter requires little but routine maintenance on moving parts, which is usually well identified in the service manuals. Problems usually appear as excessive emissions, high pressure drop, or inadequate bag life. In order to find the cause of these problems, one must have maintained sufficient Information on the system to identify what changed and when. With this information, there are logical paths to follow to the proper solutions.  相似文献   

12.
A study was conducted to evaluate performance and cost comparisons of fabric filters and alternate fine particulate control techniques. In relating the removal of fine particulate to costs, due to the lack of fractional efficiency data, it was found necessary to treat a specific application in order to make the study manageable. The case chosen is that of the coal fired industrial boiler since Enviro-Systems has a pilot program in this application area.  相似文献   

13.
This is the first installment of a 4-part series which will present capital and operating costs of selected air pollution control systems. The objective of the Series is to identify the individual component costs so that realistic system cost estimates can be determined for any specific application. In Part I, cost estimating procedures and curves are provided to develop the equipment costs for electrostatic pre-cipitators, venturi scrubbers, fabric filters, incinerators, and adsorbers.  相似文献   

14.
This report summarizes information and results presented at the 2nd Conference on Fabric Filter Technology for Coal-Fired Power Plants. Sponsored by the Air Quality Control Program, Coal Combustion Systems Division, of the Electric Power Research Institute, in cooperation with the Public Service Company of Colorado, the conference focused on recent technological developments in the design and operation of fabric filters (baghouses) in utility settings. The information presented was designed to assist utilities currently operating baghouses, preparing engineering specifications for new units, or contemplating installation of baghouses for the first time.  相似文献   

15.
This paper documents operation of reverse air fabric filters on Baltimore Gas and Electric’s C. P. Crane Units 1 and 2 cyclone boilers. Beginning immediately after startup, tubesheet pressure drop increased to high levels. Following stabilization with sonic horns and spare reverse air fans, an investigation was mounted. Diagnostic tools included both laboratory and slipstream pilot baghouses to determine cause and evaluate candidate methods of reducing pressure drop. Fundamental ash properties determined through laboratory pilot testing were in conformance with predictions. Alternate fabrics and coatings did not eliminate the problem. The root cause of the problem was that the amount of variable cake, i.e. that ash removed during cleaning, plays an important role in the dynamics of bag cleaning. These dynamics were absent in the C. P. Crane filters. Confirmation was obtained in the full scale baghouse through modification of the variable cake weight using ash reinfection. Finally, offsetting pressure drop and power consumption reductions have been obtained to achieve satisfactory operation of the baghouses.  相似文献   

16.
Pulse-jet fabric filters (PJFFs) are widely used in U.S. industrial boiler applications and in utility and industrial boilers abroad. Their small size and reduced cost relative to more conventional reverse-gas baghouses makes the use of PJFFs appear to be an attractive particulate control option for utility boilers. This paper (Part 2 of a three-part series) summarizes the results of pilot PJFF studies sponsored by the Electric Power Research Institute at different utility sites in the United States. The purpose of these tests is to evaluate PJFF performance for U.S. fossil-fuel-fired applications. These data are also used to corroborate the results of a recent worldwide survey of PJFF user experience, as described in Part 1 of this series. Part 3 will provide a cost comparison of PJFFs to other particulate control options such as electrostatic precipitators and reverse-gas baghouses.  相似文献   

17.
Pulse jet fabric filters (PJFFs) have become an attractive option of particulate collection utilities, because they can meet stringent particulate emission limits regardless of variation in operating conditions. Despite their wide applications, the present control algorithm for PJFFs can best be described as rudimentary. In this paper, a modeling and control strategy based on the local model network (LMN) is proposed. An extended self-organizing map (ESOM) network is developed to construct the LMN model of the filtration process using the filter's input-output data. Subsequently, these ESOM local models are incorporated into the design of local generalized predictive controllers (GPC), and the proposed controller design is obtained as the weighted sum of these local controllers. Simulation results show that the proposed controller design yields a better performance than both conventional GPC and proportional plus integral (PI) controllers yield.  相似文献   

18.
Wang D  Xu X  Chu S  Zhang D 《Chemosphere》2003,53(5):495-503
Chlorinated polycyclic aromatic hydrocarbons (Cl-PAHs) released from combustion of polyvinylchloride (PVC) at different furnace temperatures were investigated. A laboratory-scale tube-type furnace with electric heating was utilized to control combustion conditions. Glass fabric filters and adsorbents were used to collect the combustion emissions. Following Soxhlet extraction, concentration and column chromatography purification, isomers separation, selective detection and identification of Cl-PAHs were performed on GC/MS system on the basis of retention data and mass spectra. Their quantification was accomplished by using external standard calibration technique. About 18 Cl-PAHs were determined, most of which were monochlorinated derivatives of naphthalene, biphenyl, fluorene, phenanthrene, anthracene, fluoranthene and pyrene. Only two dichlorophenanthrenes or anthracenes were identified. The possible positions of chlorine atoms attached to the aromatic rings are predicted by quantitative structure-property relationship. The levels of these compounds were in the range of 0.30-29.08 microg/g PVC. The relationship between the formation of Cl-PAHs and PAHs was discussed.  相似文献   

19.
响应面法优化袋式除尘器脉冲清灰性能   总被引:1,自引:0,他引:1  
基于计算流体动力学的方法采用三维、可压缩、非稳态流动数学模型对袋式除尘器脉冲清灰过程进行了数值模拟,得到了滤袋内外压差,并与文献实验值进行了比较,验证了仿真模型的可靠性。基于响应面法研究了喷吹压力、喷吹高度、滤袋直径和滤袋长度对脉冲清灰性能的影响,得到这4个影响因子的二次多项式预测模型,并进行优化。结果表明,喷吹压力为0.3 MPa,喷吹高度为0.2 m,滤袋直径为0.16 m,滤袋长度为6 m时,内外压差峰值最优,优化结果与仿真模拟结果相差小于3%。研究结果为袋式除尘器脉冲清灰系统的设计与优化提供了重要参考。  相似文献   

20.
ABSTRACT

Pulse jet fabric filters (PJFFs) have become an attractive option of particulate collection utilities, because they can meet stringent particulate emission limits regardless of variation in operating conditions. Despite their wide applications, the present control algorithm for PJFFs can best be described as rudimentary. In this paper, a modeling and control strategy based on the local model network (LMN) is proposed. An extended self-organizing map (ESOM) network is developed to construct the LMN model of the filtration process using the filter's input-output data. Subsequently, these ESOM local models are incorporated into the design of local generalized predictive controllers (GPC), and the proposed controller design is obtained as the weighted sum of these local controllers. Simulation results show that the proposed controller design yields a better performance than both conventional GPC and proportional plus integral (PI) controllers yield.  相似文献   