首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
River water from three sites in different streams in Derbyshire was sampled during different periods within 1 year to evaluate fluctuations in cadmium and lead concentration. The results indicate that most of the cadmium was in solution, while most of the lead was associated with particles at all sites. Period of sampling appeared to have a greater effect on the concentration of cadmium and lead than flow rate: metal levels were higher in spring than in autumn. Nevertheless, the total lead concentration increased with flow rate, presumably because more particles were then brought into suspension; however, the lead concentration in the filtrate was reduced at higher flow rates, presumably due to dilution in the greater water volume. Dissolved cadmium concentration increased with rising flow rate at relatively low flow rates and was diluted at high flow rates. The data suggest that particles with which most of the lead is associated remain in suspension for a considerable time even when flow rate decreases.  相似文献   

2.
A turbulent wet scrubber was designed and developed to scrub particulate matter (PM) at micrometer and submicrometer levels from the effluent gas stream of an industrial coal furnace. Experiments were conducted to estimate the particle removal efficiency of the turbulent scrubber with different gas flow rates and liquid heads above the nozzle. Particles larger than 1 µm were removed very efficiently, at nearly 100%, depending upon the flow rate, the concentration of the dust-laden air stream, and the water level in the reservoir. Particles smaller than 1 µm were also removed to a greater extent at higher gas flow rates and for greater liquid heads. Pressure-drop studies were also carried out to estimate the energy consumed by the scrubber for the entire range of particle sizes distributed in the carrier gas. A maximum pressure drop of 217 mm H2O was observed for a liquid head of 36 cm and a gas flow rate of 7 m3/min. The number of transfer units (NTU) analysis for the efficiencies achieved by the turbulent scrubber over the range of particles also reveals that the contacting power achieved by the scrubber is better except for smaller particles. The turbulent scrubber is more competent for scrubbing particulate matter, in particular PM2.5, than other higher energy or conventional scrubbers, and is comparable to other wet scrubbers of its kind for the amount of energy spent.

Implications: The evaluation of the turbulent scrubber is done to add a novel scrubber in the list of wet scrubbers for industrial applications, yet simple in design, easy to operate, with better compactness, and with high efficiencies at lower energy consumption. Hence the turbulent scrubber can be used to combat particulate from industrial gaseous effluents and also has a scope to absorb gaseous pollutants if the gases are soluble in the medium used for particles capture.  相似文献   

3.
The overall particle collection efficiencies of spray scrubbers using monodisperse droplets of 100,500, and 1000 microns diameter were calculated for the cases of evaporating and condensing droplets. The properties of the gas at the inlet to the spray scrubber were maintained constant at 150°F, 100% relative humidity, and 1 atmosphere pressure. At the liquid entrance to the spray scrubber, the water droplet temperature was 50° F for the condensing case and 180° F for the evaporating case. The liquid to gas flow rate ratio for all the calculations was held constant at 4 gal/1000 acf. The gas velocity in the co-current spray tower was 1 ft/sec in the downwind direction. The calculation results show that for the particles in the 0.01 to 10 Mm diameter range, the overall spray scrubber particle collection efficiency is greater with the cooler 50°F water (condensing case) than with the warmer 180°F water (evaporating case). The effect of diffusiophoresis and thermophoresis is noticeable for all the water droplet sizes considered, but is more significant for the larger water droplets. This greater effect for the larger water droplets compared to the smaller droplets is due to the longer existence of the temperature and water vapor concentration gradients between the water droplets and the surrounding gas.  相似文献   

4.
Fürhacker M  Pressl A  Allabashi R 《Chemosphere》2003,52(10):1743-1748
Mixtures of different amines including tertiary amines (methyldiethanolamine, MDEA) are commonly used for the removal of CO2 from gas mixtures or in gas sweetening processes for the extraction of CO2 and H2S. The absorber solutions used can be released into the industrial waste water due to continuous substitution of degraded MDEA, periodically cleaning processes or an accidental spill. In this study, the aerobic biodegradability of MDEA was investigated in a standardised batch test and a continuous flow experiment (40 l/d). The results of the batch test indicated that the MDEA-solution was non-biodegradable during the test period of 28 days, whereas the continuous flow experiments showed biodegradation of more than 96% based on TOC-measurements. This was probably due to the adaptation of the microorganisms to this particular waste water contamination during continuous flow experiment.  相似文献   

5.
Abstract

Gas-phase dispersion in granular biofilter materials with a wide range of particle sizes was investigated using atmospheric air and nitrogen as tracer gases. Two types of materials were used: (1) light extended clay aggregates (LECA), consisting of highly porous particles, and (2) gravel, consisting of solid particles. LECA is a commercial material that is used for insulation, as a soil conditioner, and as a carrier material in biofilters for air cleaning. These two materials were selected to have approximately the same particle shape. Column gas transport experiments were conducted for both materials using different mean particle diameters, different particle size ranges, and different gas flow velocities. Measured breakthrough curves were modeled using the advection-dispersion equation modified for mass transfer between mobile and immobile gas phases. The results showed that gas dispersivity increased with increasing mean particle diameter for LECA but was independent of mean particle diameter for gravel. Gas dispersivity also increased with increasing particle size range for both media. Dispersivities in LECA were generally higher than for gravel. The mobile gas content in both materials increased with increasing gas flow velocity but it did not show any strong dependency on mean particle diameter or particle size range. The relative fraction of mobile gas compared with total porosity was highest for gravel and lowest for LECA likely because of its high internal porosity.  相似文献   

6.
基于景区湖泊污染的多功能水域清理船设计   总被引:1,自引:0,他引:1  
针对我国城市景区湖泊富营养化和垃圾污染严重,传统景区水域清理存在各种不足等问题,设计研发多功能水域清理船灭杀蓝藻和清理垃圾,恢复景区湖泊生态环境。结合景区湖泊污染实际状况,提出把臭氧灭杀蓝藻应用于景区湖泊清理的新概念,研发一艘可无线遥控、集打捞垃圾、过滤小型悬浮微粒和灭杀蓝藻功能于一体的多功能水域清理船。通过无线遥控多功能水域清理船,能全面清理湖面垃圾,过滤小型悬浮微粒,臭氧灭杀率能达到90%以上。利用多功能水域清理船能维护景区小湖泊生态环境,在各类景观水体和小型湖泊的污染治理中具有很好的应用前景。  相似文献   

7.
Comparative gas cleaning performance of a pilot-scale venturi scrubber with throat dimensions of 6 in. wide × 1 2 in. long × 1 2 in. deep was obtained for the following three methods of water injection: a system of spray nozzles located along each short side of the throat (Figure 2a); a continuous slot located immediately above the nozzles, along each short side of the throat (Figure 2b); and a weir located 2 ft above the spray nozzles along long side of the throat (Figure 2c). For each method of water injection the gas cleaning performance, as a function of the pressure drop, was measured by two tests: absorption of SO2 and collection efficiency for particles of methylene blue of controlled size.  相似文献   

8.
The basic oxygen process of steel manufacture evolves a large volume of gas at high temperature during the oxygen blow. This gas contains finely divided oxide particles that are removed in gas-cleaning equipment. Either electrostatic precipitators or water scrubbers are commonly used for the purpose. These devices are quite efficient but breakdowns, usually in the auxiliary equipment, are frequent. Maintenance problems arise primarily from the high temperature of the gases which warps and cracks the plates in the hood that draws the gases to the cleaning device, and from erosion of piping caused by abrasive particles moving at high velocity. This paper presents a number of case histories of BOP gas-cleaning installations, details maintenance problems, and discusses corrective measures that have been adopted. It gives reasons why merely appropriating a large sum of money for cleaning devices does not always guarantee full abatement of air pollution from the basic oxygen process.  相似文献   

9.
The properties of condensed polydisperse sulfuric acid aerosols in industrial flue gas were calculated. The condensed aqueous acid volume concentration, composition, droplet size distributions and condensed plume opacity were calculated for typical flue gas compositions, condensation nucleus size distributions and flue gas dilution ratios. The assumed initial flue gas at 170°C contained 0.035 g/acm fly ash particles, 1-20% water vapor, and 1-50 ppmv sulfuric acid vapor. The assumed gas cooling mechanism was by adiabatlc dilution with cool ambient air. Polydisperse droplet growth was calculated by assuming equal surface area increase for each particle. The calculations show that sulfuric acid condensation should have minimal effect on particles larger than 1 μm, but will form a high concentration of particles in the narrow size range of 0.05-0.5 μm diameter. Depending on the initial sulfuric acid and water vapor concentrations in the hot flue gas, the calculated maximum plume opacity following gas dilution ranged from 5% to 25%, compared to 4% for the dry condensation nucleus aerosol.  相似文献   

10.
11.
不同类型清洗剂对含聚油泥清洗效果及界面性质的影响   总被引:4,自引:0,他引:4  
为解决聚驱采出液中产生的大量含聚油泥造成石油资源浪费和环境污染问题,选用化学清洗法对含聚油泥进行处理。不同类型化学清洗剂对含聚油泥清洗效果的规律是:无机型和非离子型清洗剂对含聚油泥清洗效果最好,阴离子型清洗剂次之,阳离子型清洗剂最差。优化了无机清洗剂Na2SiO3和非离子型清洗剂EL100的脱油条件,脱油率分别达到91.12%和85.59%。不同类型清洗剂清洗含聚油泥的脱油率与油水界面性质具有明显的关联性,即脱油率越高,水相电导率越小,油滴Zeta电位绝对值越小,油滴中值粒径越大,油水界面张力越小。  相似文献   

12.
An efficient venturi scrubber system making use of heterogeneous nucleation and condensational growth of particles was designed and tested to remove fine particles from the exhaust of a local scrubber where residual SiH4 gas was abated and lots of fine SiO2 particles were generated. In front of the venturi scrubber, normal-temperature fine-water mist mixes with high-temperature exhaust gas to cool it to the saturation temperature, allowing submicron particles to grow into micron sizes. The grown particles are then scrubbed efficiently in the venturi scrubber. Test results show that the present venturi scrubber system is effective for removing submicron particles. For SiO2 particles greater than 0.1microm, the removal efficiency is greater than 80-90%, depending on particle concentration. The corresponding pressure drop is relatively low. For example, the pressure drop of the venturi scrubber is approximately 15.4 +/- 2.4 cm H2O when the liquid-to-gas ratio is 1.50 L/m3. A theoretical calculation has been conducted to simulate particle growth process and the removal efficiency of the venturi scrubber. The theoretical results agree with the experimental data reasonably well when SiO2 particle diameter is greater than 0.1 microm.  相似文献   

13.
Two important factors that affect in-stack opacity--light extinction by emitted particles and that by water moisture after a flue gas desulfurization (FGD) unit--are investigated. The mass light extinction coefficients for particles and water moisture, k(p) and k(w), respectively, were determined using the Lambert-Beer law of opacity with a nonlinear least-squares regression method. The estimated k(p) and k(w) values vary from 0.199 to 0.316 m2/g and 0.000345 to 0.000426 m2/g, respectively, and the overall mean estimated values are 0.229 and 0.000397 m2/g, respectively. Although k(w) is 3 orders of magnitude smaller than k(p), experimental results show that the effect on light extinction by water moisture was comparable to that by particles because of the existence of a considerable mass of water moisture after a FGD unit. The mass light extinction coefficient was also estimated using Mie theory with measured particle size distributions and a complex refractive index of 1.5-ni for fly ash particles. The k(p) obtained using Mie theory ranges from 0.282 to 0.286 m2/g and is slightly greater than the averaged estimated k(p) of 0.229 m2/g from measured opacity. The discrepancy may be partly due to a difference in the microstructure of the fly ash from the assumption of solid spheres because the fly ash may have been formed as spheres attached with smaller particles or as hollow spheres that contained solid spheres. Previously reported values of measured k(p) obtained without considering the effects of water moisture are greater than that obtained in this study, which is reasonable because it reflects the effect of extinction by water moisture in the flue gas. Additionally, the moisture absorbed by particulate matter, corresponding to the effect of water moisture on the particulates, was clarified and found to be negligible.  相似文献   

14.
Hung PC  Lo WC  Chi KH  Chang SH  Chang MB 《Chemosphere》2011,82(1):72-77
A laboratory-scale multi-layer system was developed for the adsorption of PCDD/Fs from gas streams at various operating conditions, including gas flow rate, operating temperature and water vapor content. Excellent PCDD/F removal efficiency (>99.99%) was achieved with the multi-layer design with bead-shaped activated carbons (BACs). The PCDD/F removal efficiency achieved with the first layer adsorption bed decreased as the gas flow rate was increased due to the decrease of the gas retention time. The PCDD/F concentrations measured at the outlet of the third layer adsorption bed were all lower than 0.1 ng I-TEQ Nm−3. The PCDD/Fs desorbed from BAC were mainly lowly chlorinated congeners and the PCDD/F outlet concentrations increased as the operating temperature was increased. In addition, the results of pilot-scale experiment (real flue gases of an iron ore sintering plant) indicated that as the gas flow rate was controlled at 15 slpm, the removal efficiencies of PCDD/F congeners achieved with the multi-layer reactor with BAC were better than that in higher gas flow rate condition (20 slpm). Overall, the lab-scale and pilot-scale experiments indicated that PCDD/F removal achieved by multi-layer reactor with BAC strongly depended on the flow rate of the gas stream to be treated.  相似文献   

15.
Results from a detailed analysis of sulfur dioxide (SO2) reductions achievable through “deep” physical coal cleaning (PCC) at 20 coal-fired power plants in the Ohio-Indiana-Illinois region are presented here. These plants all have capacities larger than 500 MWe, are currently without any flue gas desulfurization (FGD) systems, and burn coal of greater than l%sulfur content (in 1980). Their aggregate emissions of 2.4 million tons of SO2 per year represents 55% of the SO2 inventory for these states. The principal coal supplies for each power plant were identified and characterized as to coal seam and county of origin, so that published coal-washability data could be matched to each supplier. The SO2 reductions that would result from deep cleaning each coal (Level 4) were calculated using an Argonne computer model that assumes a weight recovery of 80%. Percentage reductions in sulfur content ranged from zero to 52%, with a mean value of 29%, and costs ranged from a low of $364/ton SO2 removed to over $2000/ton SO2 removed. Because coal suppliers to these power plants employ some voluntary coal cleaning, the anticipated emissions reduction from current levels should be near 20%. Costs then were estimated for FGD systems designed to remove the same amount of SO2 as was achieved by PCC through the use of partial scrubbing with bypass of the remaining flue gas. On this basis, PCC was more cost-effective than FGD for about 50% of the plants studied and had comparable costs for another 25% of the plants. Possible governmental actions to either encourage or mandate coal cleaning were identified and evaluated  相似文献   

16.
A novel two-stage wet electrostatic precipitator (ESP) has been developed using a carbon brush pre-charger and collection plates with a thin water film. The electrical and particle collection performance was evaluated for submicrometer particles smaller than 0.01- 0.5 micrometer in diameter by varying the voltages applied to the pre-charger and collection plates as well as the polarity of the voltage. The collection efficiency was compared with that calculated by the theoretical models. The long-term performances of the ESP with and without water films were also compared in tests using Japanese Industrial Standards dust. The experimental results show that the carbon brush pre-charger of the two-stage wet ESP had approximately 10% particle capture, while producing ozone concentrations of less than 30 ppb. The produced amounts of ozone are significantly lower than the current limits set by international agencies. The ESP also achieved a high collection rate performance, averaging 90% for ultrafine particles, as based on the particle number concentration at an average velocity of 1 m/sec corresponding to a residence time of 0.17 sec. Higher particle collection efficiency for the ESP can be achieved by increasing the voltages applied to the pre-charger and the collection plates. The decreased collection efficiency that occurred during dust loading without water films was completely avoided by forming a thin water film on the collection plates at a water flow rate of 6.5 L/min/m(2).  相似文献   

17.
The mixing processes of the aerosol particles from an outdoor environment in a ventilated scale chamber were experimentally studied. The particles were classified into five groups by size: 0.3–0.5 μm, 0.5–1.0 μm, 1.0–3.0 μm, 3.0–5.0 μm and 5.0–10.0 μm. The developing process for the concentration of each particle group was measured in different kinds of flow fields.The results show that the flow field configuration can effectively influence the dispersion time rate of the particles at certain positions. The increase in particle diameter can decrease the dispersion time rate. When the gas flow velocity is high, the particle dispersion time rate is independent of particle size; but when the gas flow velocity is low, particle size can significantly affect the particle dispersion time rate because the turbulent diffusion becomes important in the air and particle transport. The uniformity of the particle concentration for certain positions in steady state tends to be controlled by the inflow velocity, flow field configuration and the particle diameters.  相似文献   

18.
The flow rate through an industrial gas-cleaning cyclone at a fixed pressure drop is greater when the incoming gas is dusty than when it is clean. This observation by Briggs for a single cyclone tube was extended to multiple tubes, and ike results compared to observations by Soo and Trezek that the fraction factor for turbulent flow in a pipe is less for dusty gas than for clean. Empirical considerations indicated tJtat both of these observations should be connected with a rather large reduction in gas viscosity due to the dust. This predicted viscosity decrease was later observed. A physical theory accounting for viscosity reduction by a dust cloud is proposed. This effect also offers a means for increasing the heat, transfer coefficient in gas heat exchangers.  相似文献   

19.
Abstract

A laboratory-scale electrostatic precipitator has been designed and constructed in which the grounded collector plate has been substituted by a set of wire screens placed perpendicularly to the gas flow. Particles are deposited onto the screens by two mechanisms—electrostatic deposition and diffusional deposition—which act simultaneously. On the one hand, electrostatic deposition is effective for relatively large particles, but it is quite ineffective for the smallest ones because their charging probability in the corona field is too low. On the other hand, the diffusional collection efficiency of particles on fibers is high for small particles but low for the larger ones. Therefore, the simultaneous diffusional-electrostatic precipitation may become a useful technique for efficient filtration of particles below 0.1 μm. A preliminary experimental evaluation of this filtering device has shown that submicrometer particles with diameters down to a few nanometers can be collected with number efficiencies greater than 99%.  相似文献   

20.
A plug-flow model is developed showing the way in which efficiency depends on unfluidized bed height, bed particle size, participate mobility, gas flow rate and applied electric field intensity. This model is successfully correlated with tests in which flow rate, bed particle size, and unfluidized bed height are varied. It is shown that efficiencies better than 90% can be achieved in collecting 0.4 µm DOP with a gas residence time less than 50 msec and a pressure drop of about 10 cm of water.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号