1.
A model based on Darcy's law allows prediction of pressure drop in a pulse-jet cleaned fabric filter. The model considers the effects of filtration velocity, dust areal density added during one filtration cycle, and pulse pressure. Data used to calibrate the model were collected in experiments with three fabric surface treatments and three dusts conducted at three filtration velocities, for a total of 27 different experimental conditions. The fabric used was polyester felt with untreated, singed, or PTFE-laminated surface. The dusts used were granite, limestone and fly ash. Filtration velocities were 50,75 and 100 mm s−1. Dust areal density added during one filtration cycle was constant, as was pulse pressure. Under these conditions, fabric surface treatment alone largely determined the values for two of the three constants in the model; the third constant depends on pressure drop characteristics of the venturi at the top of each filter bag.  相似文献   

2.
The fly ash collection characteristics of a pulse-jet fabric filter have been studied. Fly ash penetration was found to decrease as the dust deposit increased from 0 to 60 micrometers in thickness, to increase as face velocity through the bags increased from 5 to 15 cm/s, and to remain relatively constant for particles from 0.3 to 4.0 µm in diameter. Experiments employing chemically tagged fly ash were performed to investigate three dust penetration mechanisms. On resumption of filtering after cleaning, penetration by straight through dust loss declined rapidly from its maximum, reached a minimum, and then increased. Seepage of dust through the fabric was found to be constant throughout the filtration cycle. Dust lost as pinhole plugs increased after cleaning, passed through a maximum, and then declined. The pinholes appeared to open the way for further penetration by the straight through mechanism.  相似文献   

3.
在自建的脉冲喷吹实验台上,利用Y—YD-7044型压电式传感器和MYD-8801加速度传感器,测试0120×2000mm覆PTFE膜无纺布滤袋在不同喷吹压力下,加文丘里与不加文丘里时的最大侧壁压力峰值和最大反向加速度,并对比计算了获得同样清灰强度时的脉冲阀一次喷吹耗气量。结果显示,添加文丘里能显著增大滤袋中下部最大侧壁压力峰值和整条滤袋上的最大反向加速度,即提高脉冲喷吹清灰强度;对应同样的喷吹压力,加文丘里时的平均最大侧壁压力峰值和平均最大反向加速度比不加文丘里时分别平均提高大约70%和50%;加文丘里获得同样清灰强度时的脉冲阀一次喷吹耗气量比不加文丘里时节省40%左右。证实对于脉冲喷吹清灰系统,添加文丘里能有效改善清灰效果以及减小能量?肖耗。  相似文献   

4.
Pulse-jet fabric filters rely on the filtration of dirty flue gas by the outside surface of the bags, which are then cleaned by a shock wave generated by an air pulse entering each bag from the top. As it travels down the length of the bag, the shock wave flexes the fabric and dislodges the dust cake. Enhancement of the pulse may be achieved by using a venturi, and cleaning may be on-line or off-line. This paper summarizes the results of an exhaustive study conducted for the Electric Power Research Institute to provide a convenient and versatile information base about the use of pulse-jet fabric filters on coal-fired boilers. Predominant features of the many pulse-jet installations identified by vendor survey and literature survey are shown in graphical and tabular form.  相似文献   

5.
Pulse-jet filter cleaning is ineffective to the extent that collected dust redeposits rather than falls to the hopper. Dust tracer techniques were used to measure the amount of redeposition in a pilot scale pulse-jet filter. A mathematical model based on experimental results was developed to describe dust transfer from bag to bag, redeposition on the pulsed bag itself, and migration to the dust hopper. Dust redeposition upon the pulsed bag increased markedly with increasing filtration velocity, whereas migration and redeposition on bags adjacent to the pulsed bag decreased. For high velocity pulse-jet filters to operate at lowest possible pressure drop, filter cake redeposition must be minimized.  相似文献   

6.
To reveal the formation mechanism of a pulse-jet airflow’s cleaning effect in a filter bag, a theoretical model is built by using the theory of the gas jet and unitary adiabatic flow according to given specifications and dimensions of the bags and resistance characteristics of the cloth and dust layer. It is about the relationship between cleaning system structure and operating parameters. The model follows the principle that the flow and kinetic energy of jet flow injected into a filter bag should be consistent with the flow of cleaning airflow in the bag and the pressure drop flowing through the filter cloth and dust layer. The purpose of the model is to achieve the peak pressure of cleaning airflow, which dominates the effect of the pulse-jet cleaning process. The cleaning system structure includes air pressure in the nozzle, structure and size of nozzle, exit velocity of nozzle, jet distance, and diameter of jet cross section. Based on the condition of the cleaning system structure and operating parameters established by using the theoretical model, Fluent software is applied to carry out a numerical simulation of the jet airflow field at the nozzle’s outlet, jet airflow field between nozzle and bag top, and cleaning airflow field in the filter bag. Experimental results are used to verify the reliability of the theoretical model. They are obtained in a pilot-scale test filter with a single bag, with length 2 m and in general full-scale dimensions of the cleaning system. The results show that when any rectification measure is not installed at the bag opening, the cross-sectional area covered by the jet gas is hardly sufficient to cover the entire area of the bag opening. A large portion of the gases injected into the filter bag will overflow reversely upward from the edge due to pressure differences between the upper area and lower area inside the bag opening. This led to a serious shortage of the cleaning airflow and ar limited increase in static pressure. When a venturi-type rectifier tube is installed at the bag opening, the jet flow is converted to funnel flow for which the cross-section velocity distribution is more uniform at the throat of the rectifier tube due to the guided effects of the upper tapered pipe. Then it is transited to stressful flow below the bag opening via rectified effects of the lower dilated pipe. The results show that the gap between the static pressure of gas in the bag and the expected value is significantly reduced. The theoretical value of the nozzle diameter is enlarged to compensate for two aspects of adverse effects of cleaning airflow and energy. This is because the flow is not a purely free-form jet from the nozzle to the entrance of the rectifier tube and because the gas suffers from local resistance while flowing through the rectifier tube. The numerical simulation and experiment show that the peak pressure of cleaning airflow in the filter bag is able to reach the expected value. The results confirm that the mechanism of the pulse-jet cleaning airflow and the calculation method of the pulse-jet cleaning system structure and operating parameters offered in this study are correct. The study results provide a scientific basis for designing the system of pulse-jet fabric filters.

Implications: Pulse-jet cleaned fabric filters are commonly used for air pollution control in many industries. Pulse-jet cleaning is widely used for this purpose as it enables frequent cleaning while the filter is operating. However, the theoretical system of the forming mechanism of the pulse-jet cleaning has not formed so far. This indicates the theoretical model plays an important role in designing effective pulse-jet cleaned fabric filters.  相似文献   


7.
Presently, there is no effective way to interpret or predict dust penetration through a pulse-jet cleaned fabric filter. This paper presents a model which considers penetration straight through the filter and penetration by seepage. A considerable number of studies have been devoted to penetration by the straight through process; however, a comparison of data from the literature with the present model indicates that seepage and not straight through penetration accounts for virtually all penetrating dust. Although insufficient information is presently available to use the model to predict penetration, the model does show trends that should occur with changes in filter operating variables such as filtration velocity and pulse pressure, and suggests areas in which further research is necessary.  相似文献   

8.
响应面法优化袋式除尘器脉冲清灰性能   总被引:1,自引:0,他引:1  
基于计算流体动力学的方法采用三维、可压缩、非稳态流动数学模型对袋式除尘器脉冲清灰过程进行了数值模拟,得到了滤袋内外压差,并与文献实验值进行了比较,验证了仿真模型的可靠性。基于响应面法研究了喷吹压力、喷吹高度、滤袋直径和滤袋长度对脉冲清灰性能的影响,得到这4个影响因子的二次多项式预测模型,并进行优化。结果表明,喷吹压力为0.3 MPa,喷吹高度为0.2 m,滤袋直径为0.16 m,滤袋长度为6 m时,内外压差峰值最优,优化结果与仿真模拟结果相差小于3%。研究结果为袋式除尘器脉冲清灰系统的设计与优化提供了重要参考。  相似文献   

9.
The concept of electrostatic stimulation of fabric filtration (ESFF) has been investigated at pilot scale. The pilot unit consisted of a conventional baghouse in parallel with an ESFF baghouse, allowing direct comparison. All results reported in this paper are for pulse-cleaned bags in which the electric field was maintained parallel to the fabric surface. The performance of the ESFF baghouse has been superior to the parallel conventional baghouse by several measures. The ESFF baghouse demonstrated: (1) a reduced rate of pressure drop increase during a filtration cycle, (2) lower residual pressure drop, (3) stable operation at higher face velocities, and (4) improved particle removal efficiency. These benefits can be obtained with only minor modifications to conventional pulse-jet hardware and at low electrical power consumption. The indicated ability to operate at increased face velocities with only modest expenditure for electrical hardware leads to very favorable economic projections.  相似文献   

10.
Experiments have been carried out to assess the effect of ammonia injection upstream of a small-scale fabric filter which collects ash from the burning of coal in Australia. The ammonia injection resulted in an increase in the pressure drop across the filter. This was apparently due to an increase in the cohesivity of the ash, which made dislodgement during cleaning more difficult. There were some indications that the ammonia-conditioned ash formed a more porous dust cake during the filtration cycle.  相似文献   

11.
This paper documents the variation in pressure drop and collection efficiency for fiberglass/fly ash fabric filter systems caused by variations in cleaning intensity (reverse air and reverse pulse), air to cloth ratio, and dust loading. Reverse air rates greater than 2 fpm were required to produce stable pressure characteristics. Pulse jet pressure greater than 50 psi reduced collection efficiency. Increased air to cloth ratios produced decreased collection efficiency.  相似文献   

12.
Computer simulations were conducted to investigate potential pressure drop reductions obtainable by combining cyclones, as pre-collectors, with fabric filters. The Leith-Licht model was used to characterize cyclone emissions and the specific resistance (K2) of the fabric filter dust cake was calculated from an empirical correlation. Several important dimensionless groups were identified and evaluated. One group, the product of the ratio of the dust cake specific resistances expected with and without the cyclone and the mass penetration of the cyclone, (K2/K2) Pn, indicates whether a pressure drop reduction is possible. A correlation was developed for this group as a function of the size properties of the inlet dust (particle mass median diameter and geometric standard deviation) and the cyclone particle cut diameter. Expressions were derived for the break-even time, the duration of filtration with the cyclone needed to show a pressure drop reduction in comparison with filtration without the cyclone. It is shown that in previously reported experiments and simulations indicating an advantage for the combined cyclone-fabric filter system, filtration cycles were typically longer than the break-even time; those showing no improvement typically had filtration times shorter than the break-even time.  相似文献   

13.
The effect of (a) fixing the time interval between cleaning pulses or (b) fixing the maximum pressure drop at which cleaning is started, on the performance of the fabric filter was investigated.A maximum pressure drop value of 2500 Pa:
  • 1.(a) minimized the effect of the filter medium resistance;
  • 2.(b) reduced the energy consumption by the filter;
  • 3.(c) minimized the dust emission from the fabric filter to the surrounding atmosphere.
  相似文献   

14.
ABSTRACT

A new model for pulse jet fabric filtration is proposed. In contrast to the earlier model of Ravin and Humphries,1 which was formulated on the steady state assumption, the present study is aimed at developing a predictive capability for both transient and steady state operations, taking into account the compression effect of filter cakes. The model's relative simplicity allows frequent updating of the model parameter values, thus improving the accuracy of predictions. As a result, the model is particularly useful in developing control algorithms and designing controllers of pulse jet fabric filtration systems.  相似文献   

15.
The analysis of pressure loss characteristics for pulse jet filters suggests that the relationship between dust adhesion to the fabric and the opposing force generated by pulse jet action plays a major role in dust removal. Hence, fabric cleanability is examined in terms of the adhesion-cohesion forces bonding the dust to the fabric vs. the intensity and frequency of the dust dislodgement forces produced by the high energy air pulses. The effect of jet size and location, jet air volume, and the intensity (pressure) and duration of the jet pulses is related to operating pressure loss.

The mechanics of energy transfer from the jet pulse to the dustladen fabric are explored in terms of jet pressure, solenoid valve action, the ratio of delivered pulse air volume to bag (tube) volume, and the elastic and flex properties of the felt bags. Effective and actual fabric dust holdings before and after cleaning are discussed with respect to steady-state dust deposition and removal rates, and operating pressure losses. Finally, predictive equations are proposed for estimating pressure loss over a broad range of design and operating parameters.  相似文献   

16.
Performance data for fabric filters using either woven or felt bags can be better understood when fault processes such as pinhole bypass and seepage are considered. Penetration straight through the dust cake and fabric may not be important by comparison. Observed trends of increased penetration with increased filtration velocity, constant or slightly increased penetration with increasing particle diameter, and constant penetration with additional dust loading can be explained by fault processes. The pulse-jet experimental work described here, done over many filtration and cleaning cycles, shows that penetration increases substantially with increasing filtration velocity and that this increase is due entirely to seepage.  相似文献   

17.
The performance features of both industrial and experimental fabric filter systems with respect to the concentration and particle size properties of the collector effluents are examined. From a qualitative viewpoint the factors that should influence significantly the collection characteristics of a fabric filter are dust properties, fabric properties, operating parameters, filter cleaning method, and critical interdependencies. The quantitative prediction of performance and the establishment of design parameters are limited for a generalized approach but data have been reported that provide excellent support for limited applications.  相似文献   

18.
A new model for pulse jet fabric filtration is proposed. In contrast to the earlier model of Ravin and Humphries, which was formulated on the steady state assumption, the present study is aimed at developing a predictive capability for both transient and steady state operations, taking into account the compression effect of filter cakes. The model's relative simplicity allows frequent updating of the model parameter values, thus improving the accuracy of predictions. As a result, the model is particularly useful in developing control algorithms and designing controllers of pulse jet fabric filtration systems.  相似文献   

19.
Some of the features of the fluidized-bed combustion (FBC) process have a direct bearing on the particulate properties that most strongly influence filtering pressure drop. A laboratory program was conducted to experimentally determine the relative pressure drop characteristics of ashes from the TVA-EPRI 20-MW bubbling bed, atmospheric pressure FBC (AFBC) pilot plant and six pulverized-coal combustion (PC) units. The combined influences of measured particle and dust cake properties on filtering pressure drop were estimated with existing filtration theories. These theories predict a higher pressure drop for a dust cake produced with the AFBC ash than for one consisting of any of the PC ashes. Laboratory measurements were made of the flow resistance of idealized, simulated dust cakes to confirm these predictions. Field operating data from the fabric filters collecting some of the tested ashes were available to validate the laboratory results. The laboratory and field data show relatively good agreement. The AFBC ash must be treated as a special case for fabric filters, and careful selection of cleaning method and fabric must be made to minimize the inherently high pressure drop characteristics of this ash.  相似文献   

20.
Coke oven pushing emissions containing quantities of tars and dust require new approaches to adapt fabric filter collectors. This paper deals with the Wheelabrator/Taisei precoat filter systems being used on coke oven pushing operations. The Taisei test program and the filter installation at Tokyo Gas are discussed. The variables to be evaluated in the design of a fabric filter emission control system are examined.  相似文献   