首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 234 毫秒
1.
Theoretical calculations and experimental measurements show that the collection of small aerosol particles (0.05 to 5 micron diameter range) by water droplets in spray scrubbers can be substantially increased by electrostatically charging the droplets and particles to opposite polarity. Measurements with a 140 acfm two chamber spray scrubber (7 seconds gas residence time) showed an increase in the overall particle collection efficiency from 68.8% tit uncharged conditions to 93.6% at charged conditions, with a dioctyl phthalate aerosol (1.05 μm particle mass mean diameter and 2.59 geometric standard deviation). The collection efficiency for 0.3 μm particles increased from 35 to 87% when charged. During 1973–1974 a 1000 acfm pilot plant electrostatic scrubber was constructed inside a 40 ft trailer for evaluation on controlling particu-late emissions from pulp mill operations (funded by Northwest Pulp and Paper Association). Field tests performed on the particle emissions exhausting from SO2 absorption towers treating the gases from a magnesium based sulfite recovery boiler have shown particle collection efficiencies ranging from about 60 to 99% by weight, depending on the electrostatic scrubber operating conditions. Energy requirements for the University of Washington electrostatic scrubber are about 0.5 hp/1000 acfm (350 Watts/1000 acfm) including gas pressure drop, water pressure drop, and electrostatic charging of the water spray droplets and the particles.  相似文献   

2.
利用FLUENT软件和SIMPLE算法对新型旋流脱硫塔的气液两相流场进行了数值模拟。计算中气相采用了RSM湍流模型,颗粒相采用了Lagrange坐标系下的随机轨道模型。分析结果表明,气相流场具有强旋流特性;喷射液滴的直径、喷淋量和烟气流速影响其在塔内的分布:喷射液滴粒径越大、喷射量越小、烟气流速越大,入口段降温越少;塔体上方截面平均浓度随液滴粒径的增加而降低,随液气比的增加而增加,随烟气流速的增加会先增加至最高值然后降低。喷淋液滴在其他运行参数不变时,平均粒径范围为0.5~1 mm,会对进口烟气起到较好的净化与降温的作用,并使塔体上方喷淋液滴在截面z=4.15 m处浓度分布均匀且覆盖率高;在保证液滴粒径较小时,通过降低烟气流速或增加喷淋量可提高液滴喷淋覆盖率,使得烟气与喷淋充分接触。计算得到的气相流场分布与实测值吻合较好,证明了数学模型的合理性,为进一步优化分离器结构提供了可靠依据。  相似文献   

3.
A large number of pressurized coal gasification processes being developed propose to use venturi scrubbers for particulate removal at high pressures. Theoretical predictions based on venturi scrubber performance models indicate that particle collection efficiency will decrease severely in these high gas pressure applications.

An exploratory theoretical and experimental program was performed to study the effect of gas pressure on venturi scrubber performance. Experiments were done on a 0.47 m3/s (1000 acfm) pilot scale venturi scrubber. Particle collection performance was determined as a function of scrubber pressure drop for venturi scrubbers operating In the range of 1-10 atm total pressure. Experimental results confirmed that the particle collection efficiency of venturi scrubbers decreases for a given scrubber pressure drop as total gas pressure Is increased. To achieve the same particle collection efficiency, the pressure drop across a venturi scrubber operated at 10 atm Is about 10 times that of the same scrubber operated at 1 atm pressure.  相似文献   

4.
Electrolyzed water (EW) is an effective disinfectant with a wide range of pH. EW in acid range was proved to be an ammonia absorbent which make it valuable for wet scrubbers used in animal feeding operations (AFOs). This study aimed to optimize the design and operating parameters of a wet scrubber with EW spray for ammonia removal, based on the size distribution of droplets, the property of EW and the reduction efficiency of ammonia. The optimized parameters included droplet size, nozzle flow rates, pH and available chlorine concentration (ACC) of EW, nozzle number at single stage, stage number, initial ammonia concentration and air speed in the duct. The ammonia removal efficiency increased with the decrease of droplet size and the increase of flow rate. The pH values of EW showed significant influence on ammonia removal efficiency (P ? 0.05), while ACC of the EW showed no significant influence (P > 0.05). For inlet ammonia concentration of 70 ppm with one and three spray stages, the wet scrubber with EW (pH = 1.35) spray was able to reduce 55.8 ± 4.3 % and 97.2 ± 3.0 % of ammonia, respectively, when the nozzles with 0.9 mm orifice diameter operated at a flow rate of 1.20 L min-1. Response surface analysis showed that orifice diameter, nozzle flow rate, and their combination were all significant factors impacting ammonia removal efficiency for both pH =1.35 and 5.50 at a 95% confidence level. Optimal ammonia removal efficiency was obtained at orifice diameter 0.9 mm and flow rate 1.20 L min-1 within the selected range. The results of this study demonstrated that wet scrubber with EW spray could be a very effective and feasible ammonia mitigation technology for animal feeding operation.

Implications: It is difficult to effectively reduce ammonia emitted from the animal feeding operations (AFOs). Both the acidity and disinfection effects of electrolyzed water (EW) make it a potential absorbent used for spray in wet scrubber to reduce the ammonia and microorganisms. Based on some preliminary field test results, lab tests were conducted to optimize the design and operation parameters of a wet scrubber with EW spray to improve the ammonia removal efficiency. A better understanding of the application and influence factors of the wet scrubber with EW spray can contribute to effective mitigation of ammonia emission from animal houses and improve the atmosphere air quality.  相似文献   


5.
A simplified equation for specifying the optimum minimum length for commercial venturi scrubber throats is presented in this paper. This theoretical correlation is derived using an optimum velocity ratio (velocity of collector droplet at end of venturi throat to velocity of gas in throat) and is a function of throat gas velocity and liquid to gas ratio. This velocity ratio establishes the minimum throat length and is based on available literature data. Predicted venturi scrubber particle collection for throats specified by this procedure compare favorably with reported commercial venturi collection efficiencies and with modeled venturi efficiencies over the practical range of venturi scrubber operation.  相似文献   

6.
为提高烟尘净化用喷嘴的雾化性能,提出一种气液两相旋流喷嘴,用CFX软件对该喷嘴内部流场模拟的结果表明,强烈的气旋作用使液流呈环状,使气液混合流在达到喷嘴末端时易于破碎成雾。在实验室条件下,利用Winner313型喷雾激光粒度分析仪对喷嘴进行了雾化粒度测定,分析发现雾滴中位径与气液比的关系呈幂函数衰减,这一规律将有助于在工程应用时确定喷嘴工况。  相似文献   

7.
The control of fugitive process emissions (FPE) with Spray Charging and Trapping (SCAT) scrubber was evaluated both theoretically and experimentally. The SCAT uses air curtain and/or jets to contain, convey, and divert the FPE into a charged spray scrubber.

Experiments were performed on an 8000 cfm bench-scale spray scrubber to verify the theory and feasibility of collecting fugitive particles with charged water spray. The effects of charge levels on drops and particles, nozzle type, drop size, gas velocity, and liquid/gas ratio on collection efficiency were determined experimentally. The results of the experiments and the comparison between theory and data are presented.

An air curtain was developed for conveying the FPE to the spray scrubber, deflecting the crosswind, and containing hot buoyant plume. The design and air flow field for the air curtain are presented.  相似文献   

8.
A modified model of venturi scrubber performance has been developed that addresses two effects of liquid surface tension: its effect on droplet size and its effect on particle penetration into the droplet. The predictions of the model indicate that, in general, collection efficiency increases with a decrease in liquid surface tension, but the range over which this increase is significant depends on the particle size and on the scrubber operating parameters. The predictions further indicate that the increases in collection efficiency are almost totally due to the effect of liquid surface tension on the mean droplet size, and that the collection efficiency is not significantly affected by the ability of the particle to penetrate the droplet.  相似文献   

9.
Comparative gas cleaning performance of a pilot-scale venturi scrubber with throat dimensions of 6 in. wide × 1 2 in. long × 1 2 in. deep was obtained for the following three methods of water injection: a system of spray nozzles located along each short side of the throat (Figure 2a); a continuous slot located immediately above the nozzles, along each short side of the throat (Figure 2b); and a weir located 2 ft above the spray nozzles along long side of the throat (Figure 2c). For each method of water injection the gas cleaning performance, as a function of the pressure drop, was measured by two tests: absorption of SO2 and collection efficiency for particles of methylene blue of controlled size.  相似文献   

10.
In a coolside desulfurization process, partly unreacted sorbent from the boiler injection, or fresh sorbent injected into the flue-gas duct, is activated by a water spray. Primarily as a result of Inertial impactions between the sorbent particles and the water droplets, highly active slurry droplets are formed. In this paper, a theoretical model for the calculation of the sorbent activation efficiency is derived. The influence of design and operating parameters on the activation has been calculated with a simulation program. The initial mean value and standard deviation of the droplet diameter and the difference in Initial velocity between the droplets and the flue-gas are shown to be the most important parameters in addition to the water/gas ratio. The sorbent particles are activated primarily in the vicinity of the atomizing nozzles.  相似文献   

11.
The sorption of hydrochloric acid (HCI) by thermally decomposed sodium bicarbonate (NaHCO3) was investigated using a fixed-bed reactor containing sorbent particles dispersed in a bed of spherical glass beads. The gas flow rate (68° F and 760 mm Hg) was 0.039 cfm (1.1 liter/min) and the bed had a cross-sectional area of 0.0055 sq. ft. (5.1 sq. cm). The influence of particle diameter (10, 45 and 163 μm), temperature (225, 275, 375, 455, and 550° F), superficial gas velocity (11 and 21 fpm at reactor conditions, 375° F), and Inlet HCI gas concentration (415 ppm and 760 ppm in N2, 275 and 455° F) were studied. Results showed that HCI sorption increased strongly with increasing temperature but was only weakly dependent on particle diameter, superficial gas velocity, and HCI gas concentration.  相似文献   

12.
The properties of condensed polydisperse sulfuric acid aerosols in industrial flue gas were calculated. The condensed aqueous acid volume concentration, composition, droplet size distributions and condensed plume opacity were calculated for typical flue gas compositions, condensation nucleus size distributions and flue gas dilution ratios. The assumed initial flue gas at 170°C contained 0.035 g/acm fly ash particles, 1-20% water vapor, and 1-50 ppmv sulfuric acid vapor. The assumed gas cooling mechanism was by adiabatlc dilution with cool ambient air. Polydisperse droplet growth was calculated by assuming equal surface area increase for each particle. The calculations show that sulfuric acid condensation should have minimal effect on particles larger than 1 μm, but will form a high concentration of particles in the narrow size range of 0.05-0.5 μm diameter. Depending on the initial sulfuric acid and water vapor concentrations in the hot flue gas, the calculated maximum plume opacity following gas dilution ranged from 5% to 25%, compared to 4% for the dry condensation nucleus aerosol.  相似文献   

13.
The exact collection mechanism of a venturi scrubber has been unknown up to this time. Photographic stop-action techniques and glass venturi scrubbers have made it possible to establish where and how particles are captured and to speculate on possible gas removal possibilities. This report extends the knowledge of pneumatic atomization which is used in gas scrubbing and many other applications by providing further information on cloud-type atomization. Cloud-type atomization which is produced by pneumatic atomization of liquid streams (not drops) results in the formation of liquid droplets which appear to be less than 10 microns in diameter. These droplets coalesce and form clouds which move as single entities. Effective overall cloud diameters are determined to be a function of the velocity of the atomizing gas stream. The effective cloud diameters start at 170 [a and increase as throat gas velocities increase from 150 ft/sec. Throat velocities and liquid inlet nozzle diameters necessary to obtain water clouds of specific effective diameters can be estimated.

These large clouds are efficient impaction targets and stop most of the particulate matter within 0.5 cm from the throat scrubbing liquid inlets. High gas absorption is expected for the clouds of droplets because turbulent gas movement can exist inside and outside the clouds and the 10 μ droplets provide exceptional surface area.  相似文献   

14.
A mathematical model has been developed to predict pressure drop in an orifice scrubber. This model is based on a Lagrangian approach for droplet movement and a particle-source-in-cell (PSI-CELL) model for calculating droplet concentration distribution. The k-epsilon turbulent model including body force due to the drag force between fluid and droplets was used to evaluate the fluid velocity distribution. The effect of orifice size on pressure drop and the correlations for mean droplet diameter have been studied. The results from the model have been compared with experimental data. This comparison shows excellent agreement between the calculated results and the experimental data.  相似文献   

15.
A concise, quantitative picture of the state of the art of particle scrubbing is presented in the form of performance prediction methods. A new relationship between the particle diameter collected at 50% efficiency and scrubber pressure drop for several of the most common scrubber types is a design tool of great utility. Scrubber capability for the collection of submicron particles by diffusion is described in a graph for several scrubber types.  相似文献   

16.
Abstract

An efficient venturi scrubber system making use of heterogeneous nucleation and condensational growth of particles was designed and tested to remove fine particles from the exhaust of a local scrubber where residual SiH4 gas was abated and lots of fine SiO2 particles were generated. In front of the venturi scrubber, normal-temperature fine-water mist mixes with high-temperature exhaust gas to cool it to the saturation temperature, allowing submicron particles to grow into micron sizes. The grown particles are then scrubbed efficiently in the venturi scrubber. Test results show that the present venturi scrubber system is effective for removing submicron particles. For SiO2 particles greater than 0.1 μm, the removal efficiency is greater than 80–90%, depending on particle concentration. The corresponding pressure drop is relatively low. For example, the pressure drop of the venturi scrubber is ~15.4 ± 2.4 cm H2O when the liquid-to-gas ratio is 1.50 L/m3. A theoretical calculation has been conducted to simulate particle growth process and the removal efficiency of the venturi scrubber. The theoretical results agree with the experimental data reasonably well when SiO2 particle diameter is greater than 0.1 μm.  相似文献   

17.
A turbulent wet scrubber was designed and developed to scrub particulate matter (PM) at micrometer and submicrometer levels from the effluent gas stream of an industrial coal furnace. Experiments were conducted to estimate the particle removal efficiency of the turbulent scrubber with different gas flow rates and liquid heads above the nozzle. Particles larger than 1 µm were removed very efficiently, at nearly 100%, depending upon the flow rate, the concentration of the dust-laden air stream, and the water level in the reservoir. Particles smaller than 1 µm were also removed to a greater extent at higher gas flow rates and for greater liquid heads. Pressure-drop studies were also carried out to estimate the energy consumed by the scrubber for the entire range of particle sizes distributed in the carrier gas. A maximum pressure drop of 217 mm H2O was observed for a liquid head of 36 cm and a gas flow rate of 7 m3/min. The number of transfer units (NTU) analysis for the efficiencies achieved by the turbulent scrubber over the range of particles also reveals that the contacting power achieved by the scrubber is better except for smaller particles. The turbulent scrubber is more competent for scrubbing particulate matter, in particular PM2.5, than other higher energy or conventional scrubbers, and is comparable to other wet scrubbers of its kind for the amount of energy spent.

Implications: The evaluation of the turbulent scrubber is done to add a novel scrubber in the list of wet scrubbers for industrial applications, yet simple in design, easy to operate, with better compactness, and with high efficiencies at lower energy consumption. Hence the turbulent scrubber can be used to combat particulate from industrial gaseous effluents and also has a scope to absorb gaseous pollutants if the gases are soluble in the medium used for particles capture.  相似文献   

18.
Particle formation from showering may be attributed to dissolved mineral aerosols remaining after evaporation of micron-sized satellite droplets produced by the showerhead or from splashing of larger shower water droplets on surfaces. Duplicate continuous particle monitors measured particle size distributions in a ventilated residential bathroom under various showering conditions, using a full-size mannequin in the shower to simulate splashing effects during showering. Particle mass concentrations were estimated from measured shower particle number densities and used to develop emission factors for inhalable particles. Emission source strengths of 2.7-41.3 microg/ m3/min were estimated under the various test conditions using residential tap water in Columbus, OH. Calculated fine particulate matter (PM2.5) concentrations in the bathroom reached several hundred micrograms per cubic meter; calculated coarse particulate matter (PM10) levels approached 1000 microg/m3. Rates of particle formation tended to be highest for coarse shower spray settings with direct impact on the mannequin. No consistent effects of water temperature, water pressure, or spray setting on overall emission rates were apparent, although water temperature and spray setting did have an effect when varied within a single shower sampling run. Salt solutions were injected into the source water during some tests to assess the effects of total dissolved solids on particle emission rates. Injection of salts was shown to increase the PM2.5 particle formation rate by approximately one third, on average, for a doubling in tap water-dissolved solids content; PM10 source strengths approximately doubled under these conditions, because very few particles >10 microm were formed.  相似文献   

19.
One of the key elements in estimating the environmental effects associated with the deposition of airborne chemicals and, in particular, salt particles from cooling towers is the drift rate. Eight different experimental methods are currently employed to determine the drift rate from cooling towers. The difficulties associated with the various techniques vary from case to case, but they are mainly associated with collecting a representative sample, maintaining undisturbed air flow, determining the collection efficiency of the various sampling techniques and analyzing the samples for particle size.

Several approaches have been taken to predict the deposition of salt water drift droplets on ground surfaces. Some use a simple analogy with the deposition of industrial dust, others use a combination of plume rise theories in conjunction with the Gaussian diffusion model to predict the air concentration of water droplets from which the ground deposition is then calculated. Other methods calculate the trajectories of the drift droplets accounting for their evaporation or employ diffusion type equations. Estimates derived from the various models used to predict drift deposition appear to vary by a factor of ±10 from each other.

In contrast to the fast development in drift loss measurements, very few attempts have been made to measure actual drift deposition from fresh and salt water cooling towers and to compare experimental results with numerical models.

This paper presents a discussion on the state-of-the-art of measuring and computing drift losses. In particular, drift rate values, droplet size distribution and some typical measured and calculated ground deposition values are discussed.  相似文献   

20.
Abstract

A wind tunnel was used to characterize the droplet size spectra of liquid sprays from several different atomizers and nozzles used under simulated aerial application conditions. The atomizers included a D8–46 nozzle, a Through Valve Boom (TVB) nozzle, and rotary cage and drum atomizers.

The D8–46 hydraulic nozzle was evaluated, using water, at orientations of 0, 10, 20, 30, 40, 50, 60, 70, 80 and 90° relative to 145 and 180 km/h airstreams. The TVB nozzle was evaluated using water, water with isopropyl alcohol, and water with a non‐ionic surfactant at airstream velocities between 130 and 180 km/h. The rotary atomizers were evaluated at different rotation rates, flow rates of water and an insecticide, in 130 and 180 km/h airstreams.

The volumetric droplet size spectra parameters (Dvo.x) decreased as the angle of the D8–46 nozzle and the airstream velocity increased. Empirical models were developed to predict these values for different windspeed and nozzle angle conditions. The TVB nozzle produced larger droplets than the other atomizers under similar conditions, with a decrease in the Dvo.x parameter values as the airstream velocity increased.

The Dvo.x parameter values produced by the rotary atomizers increased as the liquid flow rate increased, and as the rotation rate and airstream velocity decreased, and were lower for the insecticide than for water. The slotted rotary drum atomizer gave the best control over droplet size, generally producing mono‐modal droplet size spectra where the other atomizers often produced bi‐ and multimodal spectra.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏