首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
ABSTRACT

Conversion varnishes are two-component, acid-catalyzed varnishes that are commonly used to finish cabinets. They are valued for their water and stain resistance, as well as their appearance. They have been found, however, to contribute to indoor emissions of organic compounds. For this project, three commercially available conversion varnish systems were selected. A U.S. Environmental Protection Agency (EPA) Method 24 analysis was performed to determine total volatile content, and a sodium sulfite titration method was used to determine uncombined (free) formaldehyde content of the varnish components. The resin component was also analyzed by gas chromatography/mass spectroscopy (GC/MS) (EPA Method 311 with an MS detector) to identify individual organic compounds. Dynamic small chamber tests were then performed to identify and quantify emissions following application to coupons of typical kitchen cabinet wood substrates, during both curing and aging. Because conversion varnishes cure by chemical reaction, the compounds emitted during curing and aging are not necessarily the same as those in the formulation. Results of small chamber tests showed that the amount of formaldehyde emitted from these coatings was 2.3–8.1 times the amount of free formaldehyde applied in the coatings. A long-term test showed a formaldehyde emission rate of 0.17 mg/m2/hr after 115 days.  相似文献   

2.
Abstract

Consumer products are potentially significant sources of volatile organic compounds (VOCs), which are precursors to the formation of ozone in photochemical smog. To address the problem of ozone formation in ambient air, the U.S. Environmental Protection Agency (EPA) has been involved in the development of test methods for measuring the VOC content of consumer products. This paper describes results of an interlaboratory study to estimate the repeatability (precision of analyses performed by a single laboratory) and reproducibility (precision of analyses performed by different laboratories) of the consumer products’ VOC measurement method based on EPA Method 24 (for VOCs in surface coatings).

The mean method repeatability was 2.7 wt % VOC, and the mean method reproducibility was 4.8 wt % VOC. Method repeatability ranged from 0.2 to 4.4 wt % VOC, and reproducibility ranged from 0.6 to 11.9 weight percent VOC. The precision of the VOC method for consumer

products is similar to the precision of EPA Method 24 for surface coatings.  相似文献   

3.
Abstract

Three new methods applicable to the determination of hazardous metal concentrations in stationary source emissions were developed and evaluated for use in U.S. Environmental Protection Agency (EPA) compliance applications. Two of the three independent methods, a continuous emissions monitor-based method (Xact) and an X-ray-based filter method (XFM), are used to measure metal emissions. The third method involves a quantitative aerosol generator (QAG), which produces a reference aerosol used to evaluate the measurement methods. A modification of EPA Method 301 was used to validate the three methods for As, Cd, Cr, Pb, and Hg, representing three hazardous waste combustor Maximum Achievable Control Technology (MACT) metal categories (low volatile, semivolatile, and volatile). The modified procedure tested the methods using more stringent criteria than EPA Method 301; these criteria included accuracy, precision, and linearity. The aerosol generation method was evaluated in the laboratory by comparing actual with theoretical aerosol concentrations. The measurement methods were evaluated at a hazardous waste combustor (HWC) by comparing measured with reference aerosol concentrations. The QAG, Xact, and XFM met the modified Method 301 validation criteria. All three of the methods demonstrated precisions and accuracies on the order of 5%. In addition, correlation coefficients for each method were on the order of 0.99, confirming the methods’ linear response and high precision over a wide range of concentrations. The measurement methods should be applicable to emissions from a wide range of sources, and the reference aerosol generator should be applicable to additional analytes. EPA recently approved an alternative monitoring petition for an HWC at Eli Lilly’s Tippecanoe site in Lafayette, IN, in which the Xact is used for demonstrating compliance with the HWC MACT metal emissions (low volatile, semivolatile, and volatile). The QAG reference aerosol generator was approved as a method for providing a quantitative reference aerosol, which is required for certification and continuing quality assurance of the Xact.  相似文献   

4.
Abstract

The main objective of this study was to monitor the volatile organic compounds (VOCs) in the stack gas released from organic chemical industrial plants to determine emission factors. Samples from 52 stacks, with or without air pollution control devices (APCDs), from seven industrial processes were taken and VOCs measured using U.S. Environmental Protection Agency (EPA) Method 18. These 7 processes, including 26 plants, were the manufacturers of acrylonitrile–butadiene–styrene (ABS), polyvinyl chloride (PVC), polystyrene (PS), acrylic resin (ACR), vinyl chloride (VC), para–terephthalic acid (PTA), and synthetic fiber (SYF). The results clearly indicate significant variations of emission factors among the various industrial processes, particularly emission factors for those without APCDs. As expected, those with APCDs yield much less emission factors. Regardless of those with or without APCDs, the order of manufacturing processes with regard to VOC emission factors is SYF > ABS > PS > ACR > PTA > PVC > VC. The emission factors for some processes also differ from those in EPA–42 data file. The VOC profiles further indicate that some VOCs are not listed in the U.S. VOC/Particulate Matter Speciation Data System (SPECIATE). The potential O3 formation is determined from the total amount of VOC emitted for each of seven processes. The resultant O3 yield varied from 0.22 (ACR) to 2.33 g O3 g–1 VOC (PTA). The significance of this O3 yield is discussed.  相似文献   

5.
Abstract

The objective of this research was to investigate a sequentially loaded and regenerated granular activated carbon (GAC) biofilter system and to determine whether regenerative ozonation/advanced oxidation could improve the removal and biodegradation of a volatile organic compound from a contaminated airstream. Bench-scale reactors were constructed to operate in a manner analogous to a commercially available system manufactured by Terr-Aqua Environmental Systems (only with longer contact time). The GAC system consisted of two GAC biofilter beds that operated in a cyclical manner. On a given day, the first GAC bed adsorbed methyl isobutyl ketone from a simulated waste airstream, while the second bed underwent regeneration; then on the next day, the second bed was in the adsorption mode while the first was regenerated.

Three bench-scale systems were used to compare the performance under three operating conditions: (1) ozone/ associated oxidant regeneration of a GAC biofilter system that was seeded with microorganisms from a field site, (2) a humid air regeneration of a seeded GAC biofilter, and (3) a humid air regeneration of an unseeded GAC biofilter. For the advanced oxidant regenerated GAC biofilter, a maximum removal efficiency of >95% was achieved with an empty bed contact time of 148 sec and an influent concentration of 125 ppm methyl isobutyl ketone, and 90–95% was achieved at 148-sec empty bed contact time and a 1150-ppm influent.  相似文献   

6.
ABSTRACT

The CHA Corporation has completed the U.S. Air Force Phase II Small Business Innovation Research program to investigate the feasibility of using a novel microwave-based process for the removal and destruction of volatile organic compounds (VOCs) in effluents from noncombustion sources, such as paint booth ventilation streams. Removal of solvents by adsorption, followed by the regeneration of saturated granular activated carbon (GAC) by microwave energy, was achieved in a single fixed-bed reactor. Microwave regeneration of the fixed-bed-saturated carbon restored the original GAC adsorption capacity. After 20 adsorption/regeneration cycles, the adsorption capacity dropped from 13.5 g methyl ethyl ketone (MEK)/100 g GAC to 12.5 g MEK/100 g GAC. During microwave regeneration of the GAC fixed bed, the concentrated desorbed paint solvent was oxidized by passing the solvent mixture through a fixed bed of an oxidation catalyst mixed with silicon carbide in a microwave reactor. A 98% oxidation efficiency was consistently achieved from the oxidation of VOCs in the microwave catalytic reactor.  相似文献   

7.
Under contract to the U.S. Environmental Protection Agency, Research Triangle Institute has been conducting research to improve the precision, accuracy and limit of detection attainable with the EPA Method 25 nonmethane organic (NMO) analyzer. In Method 25, volatile organic carbon (VOC) samples are collected by drawing gas from an emitting source through a dry ice cooled sample trap and into an evacuated collection tank. The hydrocarbon concentration emitted from the source is determined on a per-carbon basis by catalytically converting the trap and tank sample fractions to CO2 and quantitating the amount of CO2 produced using the NMO analyzer. A reduction catalyst evaluation led to the selection of an NMO analyzer reduction catalyst which operates at a moderate temperature and displays no appreciable effect on peak shape. A gas chromatographlc column system which provides better permanent gas separation and hydrocarbon quantitation was also selected for use in the NMO analyzer.  相似文献   

8.
Abstract

This study attempts to assess the effectiveness of control strategies for reducing volatile organic compound (VOC) emission from the polyvinyl chloride (PVC) wallpaper production industry. In Taiwan, methyl ethyl ketone, TOL, and cyclohexanone have comprised the major content of solvents, accounting for ~113,000 t/yr to avoid excessive viscosity of plasticizer dioctyl phthalate (DOP) and to increase facility in working. Emissions of these VOCs from solvents have caused serious odor and worse air quality problems. In this study, 80 stacks in five factories were tested to evaluate emission characteristics at each VOC source. After examining the VOC concentrations in the flue gases and contents, the VOC emission rate before treatment and from fugitive sources was 93,000 and 800 t/yr, respectively. In this study, the semiwet electrostatic precipitator is recommended for use as cost-effective control equipment.  相似文献   

9.
Select volatile organic compounds (VOCs) in ambient air were measured at four fenceline sites at a petroleum refinery in Whiting, IN, using modified EPA Method 325 A/B with passive tubes and EPA Compendium Method TO-15 with canister samplers. One-week, time-integrated samplers were deployed for 8 weeks with tubes and canister samplers deployed in duplicate. Good precision was obtained from the duplicate tubes (<7%) and duplicate canisters (≤10%) for BTEX, perchloroethylene, and styrene. The tubes yielded statistically significantly higher concentrations than canisters for benzene, toluene, ethylbenzene, and m,p-xylene. However, all differences were estimated to be <0.1 ppbv. No concentration differences among the four Whiting sites were found for any of the VOCs.

Implications: Recently enacted EPA Methods 325A/B use passive-diffusive tube samplers to measure benzene at refinery fenceline locations. This pilot study presents VOC data applying a modified version of EPA Method 325 A/B and its comparison to EPA Compendium Method TO-15 canister samplers at four refinery fenceline sites. The findings from this study provide additional confidence in application of the tube method at refineries to ascertain VOC source influence since tube and canister samplers were comparable and good precision was obtained from duplicate sampling for both methods. No overall difference in these reported VOC concentrations was found between Whiting sites for tubes or canisters.  相似文献   


10.
Three new methods applicable to the determination of hazardous metal concentrations in stationary source emissions were developed and evaluated for use in U.S. Environmental Protection Agency (EPA) compliance applications. Two of the three independent methods, a continuous emissions monitor-based method (Xact) and an X-ray-based filter method (XFM), are used to measure metal emissions. The third method involves a quantitative aerosol generator (QAG), which produces a reference aerosol used to evaluate the measurement methods. A modification of EPA Method 301 was used to validate the three methods for As, Cd, Cr, Pb, and Hg, representing three hazardous waste combustor Maximum Achievable Control Technology (MACT) metal categories (low volatile, semivolatile, and volatile). The modified procedure tested the methods using more stringent criteria than EPA Method 301; these criteria included accuracy, precision, and linearity. The aerosol generation method was evaluated in the laboratory by comparing actual with theoretical aerosol concentrations. The measurement methods were evaluated at a hazardous waste combustor (HWC) by comparing measured with reference aerosol concentrations. The QAG, Xact, and XFM met the modified Method 301 validation criteria. All three of the methods demonstrated precisions and accuracies on the order of 5%. In addition, correlation coefficients for each method were on the order of 0.99, confirming the methods' linear response and high precision over a wide range of concentrations. The measurement methods should be applicable to emissions from a wide range of sources, and the reference aerosol generator should be applicable to additional analytes. EPA recently approved an alternative monitoring petition for an HWC at Eli Lilly's Tippecanoe site in Lafayette, IN, in which the Xact is used for demonstrating compliance with the HWC MACT metal emissions (low volatile, semivolatile, and volatile). The QAG reference aerosol generator was approved as a method for providing a quantitative reference aerosol, which is required for certification and continuing quality assurance of the Xact.  相似文献   

11.
Abstract

Screening of biofiltering material for treatment of volatile organic compounds was performed by using a gas stream containing methyl ethyl ketone (MEK) as a target pollutant. Filtering media (FM) for screening were prepared by blending compost (such as pig and cow manure) and filling material (such as fern chips, wheat bran, and bagasse). Results show that a blend of pig manure/fern chips = 9:1 (wt basis) was superior with respect to the stability of the pH and the water-holding capacity of the FM and in the capacity for treating the target compound. Complete removal of the target compound was obtained at an organic loading of 100 g per cubic meter of filtering media per hour. By using the screened FM for treating MEK and toluene, long-term stability (>1,200 hours) and complete removal can be obtained at an organic loading of 50 g per cubic meter of FM per hour for either compound.  相似文献   

12.
Abstract

U.S. Environmental Protection Agency (EPA) Emission Measurement Center in conjunction with EPA Regions VI and VIII, the state of Utah, and the U.S. Department of Defense have conducted a series of long-term pilot and field tests to determine the accuracy and reliability of a visible opacity monitoring system consisting of a conventional digital camera and a separate computer software application for plume opacity determination. This technology, known as the Digital Opacity Compliance System (DOCS), has been successfully demonstrated at EPA-sponsored Method-9 “smoke schools,” as well as at a number of government and commercially operated industrial facilities.

Results from the current DOCS regulatory pilot study demonstrated that, under regulatory enforcement conditions, the average difference in opacity measurement between the DOCS technology and EPA Reference Method 9 (Method 9) was 1.12%. This opacity difference, which was computed from the evaluation of 241 regulated air sources, was found to be statistically significant at the 99% confidence level. In evaluating only those sources for which a nonzero visible opacity level was recorded, the average difference in opacity measurement between the DOCS technology and Method 9 was 1.20%. These results suggest that the two opacity measurement methods are essentially equivalent when measuring the opacity of visible emissions.

Given the costs and technical limitations associated with use of Method 9, there is a recognized need to develop accurate, reproducible, and scientifically defensible alternatives to the use of human observers. The use of digital imaging/processing brings current technology to bear on this important regulatory issue. Digital technology offers increased accuracy, a permanent record of measurement events, lower costs, and a scientifically defensible approach for opacity determination.  相似文献   

13.
Abstract

In an earlier paper the ozone-forming potential of n-propyl bromide (NPB) was studied with a new methodology designed to address issues associated with a marginal smog-forming compound. However, the U.S. Environmental Protection Agency (EPA) subsequently revised its policy and now recommends using the Maximum Incremental Reactivity (MIR) scale to rank the ozone-forming potential of all volatile organic compounds (VOCs), including those of marginal ozone productivity. Nevertheless, EPA contemplated exceptions to the box-model-derived MIR scale by allowing use of photochemical grid-model simulations for case specific reactivity assessments. The California Air Resources Board (CARB) also uses the MIR scale and CARB has a Reactivity Scientific Advisory Committee that can consider exceptions to the MIR scale. In this study, grid-model simulations that were recommended by EPA are used to evaluate the incremental ozone impacts of NPB using an update to the chemical mechanism developed in an earlier paper. New methods of analysis of the grid-model output are further developed here to quantify the relative reactivities between NPB and ethane over a wide range of conditions. The new grid-model-based analyses show that NPB is significantly different and generally less in ozone-forming potential (i.e., reactivity) than predicted by the box-model-based MIR scale relative to ethane, EPA’s “bright-line” test for non-VOC status. Although NPB has low reactivity compared to typical VOCs on any scale, the new grid-model analyses developed here show that NPB is far less reactive (and even has negative reactivity) compared to the reactivity predicted by the MIR scale.  相似文献   

14.
Abstract

Air quality is degraded by many factors, among which the emissions from on‐road vehicles play a significant role. Timely and accurate estimate of such emissions becomes very important for policy‐making and effective control measures. However, lack of traffic data and outdated emission software make this task difficult. This research has demonstrated a new method that facilitates the vehicular emission inventories at the local level by using shorter-time Highway Performance Monitoring System (HPMS) traffic data along with the latest U.S. Environment Protection Agency (EPA) emission modeling software, MOBILE6. The conversion methodology was developed for converting readily available HPMS traffic volume data into EPA MOBILE-based traffic classifications, and a corresponding software program was written for automating the process. EPA MOBILE6 model was used to obtain emissions of nitrogen oxides (NOx), volatile organic compound (VOC), and cabon monoxide (CO) emitted by the parent traffic and subsampled traffic data, and these emissions were additionally compared. The case study has shown that the difference of the magnitude between the emission estimates produced by certain subsampled and parent traffic data are minor, indicating that subsampled HPMS data can be used for reporting parent traffic emissions. It was also observed that traffic emissions follow a Weibull distribution, and NOx emissions were more sensitive to the traffic data composition than VOC and CO. Lastly, use of average emission values of 20 or 30 consecutive minutes appears to be valid for representing hourly emissions.  相似文献   

15.
Although widely used in air quality regulatory frameworks, the term “volatile organic compound” (VOC) is poorly defined. Numerous standardized tests are currently used in regulations to determine VOC content (and thus volatility), but in many cases the tests do not agree with each other, nor do they always accurately represent actual evaporation rates under ambient conditions. The parameters (time, temperature, reference material, column polarity, etc.) used in the definitions and the associated test methods were created without a significant evaluation of volatilization characteristics in real world settings. Not only do these differences lead to varying VOC content results, but occasionally they conflict with one another. An ambient evaporation study of selected compounds and a few formulated products was conducted and the results were compared to several current VOC test methodologies: SCAQMD Method 313 (M313), ASTM Standard Test Method E 1868-10 (E1868), and U.S. EPA Reference Method 24 (M24). The ambient evaporation study showed a definite distinction between nonvolatile, semivolatile, and volatile compounds. Some low vapor pressure (LVP) solvents, currently considered exempt as VOCs by some methods, volatilize at ambient conditions nearly as rapidly as the traditional high-volatility solvents they are meant to replace. Conversely, bio-based and heavy hydrocarbons did not readily volatilize, though they often are calculated as VOCs in some traditional test methods. The study suggests that regulatory standards should be reevaluated to more accurately reflect real-world emission from the use of VOC containing products.
Implications:The definition of VOC in current test methods may lead to regulations that exclude otherwise viable alternatives or allow substitutions of chemicals that may limit the environmental benefits sought in the regulation. A study was conducted to examine volatility of several compounds and a few formulated products under several current VOC test methodologies and ambient evaporation. This paper provides ample evidence to warrant a reevaluation of regulatory standards and provides a framework for progressive developments based on reasonable and scientifically justifiable definitions of VOCs.  相似文献   

16.
Frequent smog episodes occur during spring, summer, and autumn in Insubria, Northern Italy. On a test site in this area the atmospheric concentration of the photo-oxidants ozone and peroxyacetyl nitrate has been monitored over a year (2000) together with ozone precursors listed in the European Union Air Quality Directive 2002/3/EC, such as nitrous oxides (NOX) and volatile organic compounds (VOC) including hydrocarbons and carbonyls. The results of this study revealed a strong impact of biogenic isoprene on the air quality.In winter isoprene was detected at the ppt level and correlated with anthropogenic VOC. However, during the growing season isoprene exhibited a distinct diurnal variation with maximum concentrations late in the afternoon reaching up 70 ppbC attributed to strong emissions from the abundant vegetation of broad-leaf deciduous trees in this area. A new HPLC-MS method was developed for the determination of isoprene's primary atmospheric oxidation products methacrolein as its 2,4-dinitrophenylhydrazone and methyl vinyl ketone as an unusual double derivative with 2,4-dinitrophenylhydrazine. Methacrolein and methyl vinyl ketone followed the same diurnal and annual trends as isoprene. The average monthly concentration of isoprene and these products ranged from around 10 ppbC in June, July and September to 20 ppbC in August, which constitutes 15–30% of C3–C9 VOCs. The contribution from isoprene photo-oxidation to the ambient air formaldehyde concentrations was also found to be high during this period ranging from 30% to 60% in May, June, July and August.From the atmospheric VOC and NOX concentrations the local photochemical ozone formation was estimated by the incremental reactivity approach. The calculations showed that in summer isoprene's contribution to the local ozone formation was as high as 50–75%.  相似文献   

17.
Hunt GT  Lihzis MF 《Chemosphere》2011,85(11):1664-1671
The Connecticut Department of Environmental Protection (CTDEP) commenced monitoring for PCDDs/PCDFs (polychlorinated dibenzodioxins and polychlorinated dibenzofurans) in ambient air in 1987 and adopted the long term (30 d) sampling approach in 1993. The CTDEP method represents the first use of isotopically labeled PCDDs/PCDFs as field surrogates to monitor the behavior of native PCDDs/PCDFs present in actual ambient air samples. This feature first introduced in 1987 was later adopted by US EPA in revisions to sampling methods for PCDDs/PCDFs in ambient air (EPA Method TO9A) as well as development of EPA Reference Method 23 for measurement of PCDDs/PCFDs in stationary source emissions. Results are provided here for a total of twenty-three (23) samples (reported as pairs) representing twelve (12) 30 d sampling events conducted at a site located in metropolitan Hartford CT. Samples were collected in winter months during calendar years 2002-2008. PCDDs/PCDFs concentration data (pg m−3) are reported as both congener sums (Cl4-Cl8) and 2378-substitued congeners. Total PCDDs/PCDFs concentrations for these twelve (12) sampling events ranged from 0.68 pg m−3 (2003) to 4.18 pg m−3 (2004) with a mean concentration of 2.04 pg m−3.Method performance was monitored through use of collocated samples, in field isotopically labeled compounds, isotopically labeled laboratory applied internal standards and field blank samples. Method performance consistently exceeded goals established in USEPA Method TO9A for these same parameters. Average recoveries of in field labeled PCDDs/PCDFs ranged from 97.5% to 104.2%. Average (mean) recoveries for each of the ten (10) isotopically labeled internal standards ranged from 77.0% (13C-OCDF) to 95.5% (13C-2,3,7,8-TCDF). Method precision defined as % RPD data for collocated sampler pairs ranged from 8% to 14% for PCDDs and from 5% to 12% for PCDFs. The mean RPD for all PCDDs/PCDFs combined is 9.6%. Field monitoring results demonstrate method sensitivity for all PCDDs/PCDFs congeners and 2378-substituted congeners to be well below concentrations typically found for these compounds in ambient air (all reported data represent measured concentrations). Quantities (pg) found in field blanks represent the major determinant to achieving further enhancements in method sensitivity for selected congeners (OCDD < 42 fg m−3; 1,2,3,4,6,7,8-HpCDD < 5.7 fg m−3; and 1,2,3,4,6,7,8-HpCDF < 2.1 fg m−3). The CTDEP method represents a highly sensitive and reliable technique for monitoring of PCDDs/PCDFs congeners and other persistent organic pollutants (POPs) at ultra trace levels in ambient air (fg m−3).  相似文献   

18.
ABSTRACT

Under the Clean Air Act Amendments of 1990, the U.S. Environmental Protection Agency (EPA) determined that regulation of mercury emissions from coal-fired power plants is appropriate and necessary. To aid in this determination, preliminary estimates of the performance and cost of powdered activated carbon (PAC) injection-based mercury control technologies were developed. This paper presents these estimates and develops projections of costs for future applications.

Cost estimates were developed using PAC to achieve a minimum of 80% mercury removal at plants using electrostatic precipitators and a minimum of 90% removal at plants using fabric filters. These estimates ranged from 0.305 to 3.783 mills/kWh. However, the higher costs were associated with a minority of plants using hot-side electrostatic precipitators (HESPs). If these costs are excluded, the estimates range from 0.305 to 1.915 mills/kWh. Cost projections developed using a composite lime-PAC sorbent for mercury removal ranged from 0.183 to 2.270 mills/kWh, with the higher costs being associated with a minority of plants that used HESPs.  相似文献   

19.
ABSTRACT

A pilot apparatus of a regenerative catalytic oxidizer (RCO) equipped with two electrical heaters and two 20-cm i.d. × 200-cm height regenerative beds was used to treat methyl ethyl ketone (MEK) and toluene, respectively, in an airstream. The regenerative beds were packed with gravel (approximate particle size 1.25 cm, specific area 205 m2/m3, and specific heat capacity 840 J/kg °C) as a solid regenerative material and K-type thermal couples for measuring solid and gas temperatures, respectively. The catalyst bed temperature was kept around 400 °C and the gas superficial velocity was operated at 0.234 m/sec. This investigation measured and analyzed distributions of solid and gas temperatures with operating time and variations of volatile organic compound (VOC) concentrations in the regenerative beds. The overall VOC removal efficiency exceeded 98% for MEK and 95% for toluene. Degradation of VOCs will exist for MEK on the surface of solid material (gravel) in the temperature range of 330-400 °C, but toluene does not exhibit this phenomenon.  相似文献   

20.
ABSTRACT

A new technology for monitoring airborne heavy metals on aerosols and particulates based on spark-induced breakdown spectroscopy (SIBS) was evaluated at a joint U.S. Environmental Protection Agency (EPA)/U.S. Department of Energy test at the rotary kiln incinerator simulator (RKIS) facility at EPA/Research Triangle Park, NC, in September 1997. The instrument was configured to measure lead and chromium in a simulated combustion flue gas in real time and in situ at target levels of 15 and 75 u, g/dry standard cubic meters. Actual metal concentrations were measured during the tests using EPA Reference Method (RM) 29.

The SIBS technology detected both lead and chromium at the low- and high-level concentrations. Additionally, the hardware performed without failure for more than 100 hr of operation and acquired data for 100% of the RM tests. The chromium data were well correlated with concentration increases resulting from duct operations and pressure fluctuations that are known to entrain dust.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号