首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This paper describes a micro method for the determination of the fluoride content of plant materials, particularly the leaves. The samples are dried and ground to a fine powder. Fifty milligram samples are burned in oxygen in 250-ml separatory funnels or in 300-ml Erienmeyer flasks. The gaseous products of the combustion are absorbed in 0.1 N NaOH in the closed funnel or flask and transferred to a small covered plastic dish in which the fluoride is diffused to tiny droplets of 3N sodium hydroxide solution distributed over the lower side of a tight fitting cover. The diffused fluoride is dissolved in water and determined colori-metrically by the SPADNS reagent.  相似文献   

2.
The body of the information presented in this paper is of general interest to those concerned with air quality. This paper reports data for ambient atmospheric concentrations of water-soluble fluorides determined in samples of suspended particulate matter collected on glass-fiber filters by the National Air Surveillance Network. Data for over 12,000 samples collected in calendar years 1966, 1967, and 1968 are examined. The purpose of the examination of the data is to give an estimation of current air quality with respect to fluoride content.

The samples are extracted with pure boiling water, and the fluoride concentration of the extracts measured using a fluoride-ion selective electrode. The data engendered are tabulated on an annual basis, and a table is presented summarizing the results. Comparative data will be presented showing the distribution of urban and non-urban stations that exhibit various specified fluoride levels. The results show that the fluoride content in the majority of the samples is below the minimum detectable amount of 0.05 µgF/m3. Conclusions that can be drawn include the observations that: few of the urban samples contain over 1.00 µg/m 3 of fluoride, very few of all samples exceeded 1.00 µ/m3 of fluoride, and no non-urban sample contained over 0.16 µg/m3 of fluoride. It was also concluded that only in rare instances would the fluoride concentrations at the sites sampled be in excess of published standards.  相似文献   

3.
The objective of this study was to determine the concentrations of polycyclic aromatic hydrocarbons (PAHs) in cow's milk from industrial farms that are located near an industrial park in Hidalgo, Mexico. It was found that the concentrations of PAHs in the raw milk of cattle from industrial farms have increased in recent years. Composite samples were collected between 2008 and 2010 and analysis carried out according to 8100 EPA procedures and analyzed by gas chromatography with FID detection. The results show that combustion PAHs were mostly Ace, Acy, and Fla (0.25, 0.32, and 0.22 µg g?1, respectively). Diagnostic ratios were used to show that the probable sources were grass and fuel combustion. The sum of concentrations of 16 individual PAHs did not breach permissible levels in milk (25 µg g?1 according to the United States EPA), indicating a limited health risk to animals and humans in the study area. The industrial park has adequate pollutant emission regulations.  相似文献   

4.
The nitrate ion selective electrode was investigated as an alternative approach to the present colorimetric determination of nitrate resulting from oxidative absorption of nitrogen oxides from combustion effluents. The electrode offers advantages of speed and relatively simple experimental procedure. Replicate measurements of 10?4–10?2M nitric acid solutions using bracketing standards show that the electrode approach is capable of good precision (coefficient of variation = ±4%). Comparison of a method utilizing the nitrate electrode with the more laborious phenol disulfonic acid method for the measurement of nitrogen oxides in both oil and gas fired combustion effluents showed agreement within 4% of the mean even in the presence of high levels of SO2. The correlation coefficient found for PDS vs nitrate electrode is 0.987.  相似文献   

5.
A carbon paste electrode was used for the electrochemical quantification of carbendazim in water and orange juice samples. Carbendazim oxidation on the electrode surface was found to be controlled by adsorption. The novel electrochemical procedure for carbendazim quantification employed differential pulse voltammetry using a carbon paste electrode under optimal conditions. Carbendazim oxidation currents were linear at concentrations of 2.84 to 45.44 µg L?1, with a limit of detection of 0.96 µg L?1. The proposed method was applied to carbendazim quantification in ultrapurified water, river water, and orange juice. Recovery rates in water and orange juice samples were in the 97%–101% range, indicating that the method can be employed to determine carbendazim in these matrices, with advantages including shorter analysis time and lower cost than routine methods such as chromatography or spectroscopy. The electrode showed good reproducibility, remarkable stability, and especially good surface renewability by simple mechanical polishing. The recovery rates observed were highly concordant with those obtained for high-performance liquid chromatography, having a relative standard deviation of less than 1.3%.  相似文献   

6.
采用自制的炭气凝胶平板电极进行模拟水样中氟的电吸附去除研究,通过单因子实验优化了该电吸附技术的操作参数和适用的溶液条件,并研究了反接电极法的再生效果。研究结果表明,自制的炭气凝胶平板由纳米颗粒组成三维网络结构,比表面积为670.90 m2/g,具有良好的充放电可逆性和迅速形成表面双电层的特点。静态电吸附除氟效果最佳的条件为:水样氟离子浓度6 mg/L,pH 7.0,极板间距4 cm,电压1.6 V;共存物质硝酸根、腐殖酸、碳酸根和碳酸氢根等对氟离子的电吸附具有一定的促进作用。吸附氟离子后的炭气凝胶材料的比表面、孔体积、电容值有所减小。对于吸附氟离子后的炭气凝胶平板电极,采用反接电极法取得较好再生效果的条件为:流动状态、电压1.6 V、极板间距4 cm。再生后的炭气凝胶电极与原始炭气凝胶相比,依然具有良好的充放电可逆性。  相似文献   

7.
The body of information presented in this paper is directed to those individuals concerned with methods for the sampling and measurement of fluorides contained in stack gases produced during the manufacture of phosphate fertilizer or aluminum. An air stream containing gaseous hydrogen fluoride (HF), at concentrations of from 87 to 1700 µg F m-3, was generated and passed through 193 to 198 cm lengths of Pyrex glass, type 316 stainless steel, TFE Teflon, and methyl methacrylate-coated aluminum probes at flow rates of 28 I min-1. HF passing through the probes was collected in deionized water contained in a Greenburg-Smith impinger. The Teflon probe exhibited no loss of HF and no trend toward increased passage of HF with time. Significant amounts of fluoride were lost in 18 out of 20 tests with the methacrylate probe and in 4 out of 20 tests with the Pyrex and stainless steel probes. Trends toward increased passage of HF with time occurred with the latter three probe materials. The selective ion electrode and semiautomated methods gave equivalent results when samples were made alkaline to avoid sorption of fluoride by Tygon tubing used in the semiautomated method. These results demonstrated that a Teflon probe gave the most representative sample of gaseous HF. However, additional tests are needed before a final recommendation is made for a probe to sample fluorides in stack gases.  相似文献   

8.

Fluoride is highly present in the environment, especially in water and its derivatives. Excessive fluoride contribution to diet poses a health risk. Tea leaves accumulate fluoride and the consumption of tea (Camellia sinensis) could pose a risk to human by the excessive fluoride intake. Ninety tea samples were analyzed by potentiometry using a selective fluoride ion electrode. Mixed tea samples (2.82?±?1.11 mg/L) and black tea samples (2.28?±?0.79 mg/L) recorded the highest fluoride levels. The contribution of drinking water is important for increasing fluoride levels in teas. The daily consumption of two cups (250 mL per cup) of mixed and black teas prepared with La Laguna tap water does pose a health risk for children (4–8 years old) because of the high contribution percentages (74.4% and 63.6%, respectively) of the Tolerable Upper Intake Level set in 2.5 mg/day by the EFSA (European Food Safety Authority). A minor consumption in children (4–8 years old) and adults during pregnancy is advisable.

  相似文献   

9.
MC analysis of biological tissue is considered to be very difficult due to the lack of validated methods. This is the primary limiting factor for monitoring potential risks in both the flesh of aquatic organisms and the aquatic ecosystem. In this study, an effective method to determine free MCs (MC-LR and MC-RR) in the muscle and liver tissues of freshwater cultured fish was developed using solid-phase extraction (SPE) and liquid chromatography-tandem mass spectrometry (LC/MS-MS). The extraction solvent, time of extraction, eluent and purification of the extract were optimized. Various SPE cartridges were also investigated. In this optimized analytical procedure, an 85% methanol/water solution (v/v) was selected as the extraction solvent, after which the extracts were purified by removing fats and proteins; a HLB cartridge was chosen for MCs enrichment; and 90% methanol containing 0.02% formic acid/water solution (v/v) was used as the eluent. Under the optimized pretreatment conditions and instrument parameters, good recoveries of MC-LR and MC-RR were obtained at three concentrations (0.5, 1.0 and 2.0 µg g?1 dry weight (DW)), with values ranging from 92.5 to 98.3% and 92.1 to 98.6%, respectively. The method detection limit (MDL) for muscle samples was 0.5 µg kg?1 and 0.4 µg kg?1 (DW) for MC-LR and MC-RR, respectively. The MDL for the liver samples was 0.8 µg kg?1 (DW) for both MC-LR and MC-RR. The developed procedure was successfully applied to analyze MCs in the muscle and liver of fish samples collected from a Chinese freshwater aquaculture pond during bloom seasons. The MC-LR concentrations ranged from below the MDL to 4.17 µg kg?1 and the MC-RR concentrations ranged from below the MDL to 2.64 µg kg?1.  相似文献   

10.
采用溶胶-凝胶法制备TiO2凝胶,将TiO2凝胶涂覆在活性炭纤维表面并进行热处理制备改性电极(TiO2/ACF),利用扫描电子显微镜(SEM)、X射线衍射光谱仪(XRD)、比表面和孔隙度分析仪对负载前后电极的表面特性进行表征,并探讨了其对NaF溶液的电吸附效果。结果表明,电极负载TiO2后表面变得粗糙,比表面积和总孔体积减小,而介孔体积和平均孔径增大。此外,表面的TiO2同时以金红石和锐钛矿的晶型存在。电吸附实验结果显示,加电可以提高吸附容量,而且电压、pH和初始氟离子浓度均对电吸附容量产生影响:电压增大,吸附容量增加,当施加电压为2 V时,电吸附容量为1.03 mg/g,比开路电位时提高40%;pH可以通过影响氟离子在溶液中的存在形态和TiO2/ACF电极表面的羟基基团对电吸附容量产生影响;初始氟离子浓度升高,电极吸附容量增大,但是去除率降低。在处理初始氟离子浓度为4 mg/L的NaF溶液时,在2 V电压、中性pH和12 h的吸附时间下,改性ACF为电极的吸附量为1.32 mg/g。  相似文献   

11.
ABSTRACT

The aim of this study was to determine the level of chlorinated hydrocarbon residues in selected edible mushrooms from north-eastern Poland. The experiment was carried out on 45 samples consisting of 15 fruiting bodies each of the following species: Boletus edulis, Imleria badia and Cantharellus cibarius. Dried samples were subjected to extraction of lipids with a Soxhlet and a standard procedure—based on the decomposition of lipids by concentrated sulfuric acid and the release of organic insecticides to the hexane layer—was used to determine chlorinated hydrocarbons. The quantitative determination of DDT, DDE, DDD and γ-HCH were conducted using gas chromatography with electron capture detection (GC-ECD). Chlorinated hydrocarbons were found in all tested samples. The contents of these compounds varied between all three species. Mean content of γ-HCH in B. edulis, I. badia and C. cibarius was: 2.60; 4.83; 7.52 µg kg?1 of lipids, while the content of ΣDDT was: 57.02; 25.20; 127.10 µg kg?1 of lipids, respectively. These results show that mushrooms from the north-eastern part of Poland can be used as potential bio-indicators of environmental contamination with chlorinated hydrocarbons. Moreover, the studied fungi could still be used as food due to the low levels of analyzed organochlorine compounds.  相似文献   

12.
负载TiO2的活性炭纤维改性电极电吸附除氟   总被引:2,自引:1,他引:1  
采用溶胶-凝胶法制备TiO2凝胶,将TiO2凝胶涂覆在活性炭纤维表面并进行热处理制备改性电极(TiO2/ACF),利用扫描电子显微镜(SEM)、X射线衍射光谱仪(XRD)、比表面和孔隙度分析仪对负载前后电极的表面特性进行表征,并探讨了其对NaF溶液的电吸附效果。结果表明,电极负载TiO2后表面变得粗糙,比表面积和总孔体积减小,而介孔体积和平均孔径增大。此外,表面的TiO2同时以金红石和锐钛矿的晶型存在。电吸附实验结果显示,加电可以提高吸附容量,而且电压、pH和初始氟离子浓度均对电吸附容量产生影响:电压增大,吸附容量增加,当施加电压为2 V时,电吸附容量为1.03 mg/g,比开路电位时提高40%;pH可以通过影响氟离子在溶液中的存在形态和TiO2/ACF电极表面的羟基基团对电吸附容量产生影响;初始氟离子浓度升高,电极吸附容量增大,但是去除率降低。在处理初始氟离子浓度为4 mg/L的NaF溶液时,在2 V电压、中性pH和12 h的吸附时间下,改性ACF为电极的吸附量为1.32 mg/g。  相似文献   

13.
Chemically chlorinated organic matter as well as natural background humic acids contain significant amounts of organically bound halogens that must be determined for assessment of environmental pollution. In this work the use of ion chromatography (IC) and inductively coupled plasma mass spectrometry (ICP-MS) is proposed for the determination of total organic Cl, Br and I concentration in humic acids extracted from various forest soil horizons after a single digestion by microwave-induced combustion (MIC). Samples were pressed as pellets and combusted using 20 bar of oxygen and ammonium nitrate solution as igniter. Analytes were absorbed in diluted alkaline solution (50 mM (NH4)2CO3) and a reflux step was applied after combustion to improve analyte recoveries (5 min, microwave power of 1400 W). The accuracy was evaluated using certified reference materials (CRM) and spiked samples. Using MIC the agreement with CRM values and spike recoveries was higher than 97% for all analytes. As an advantage over conventional procedures, using MIC it was possible to digest up to eight samples in only 25 min, obtaining a single solution suitable for all halogens determination in humic acids samples by different techniques (IC and ICP-MS). The limit of detection (3σ) for Cl, Br and I obtained by IC was 1.2, 2.5 and 4.3 μg g−1 and by ICP-MS it was 1.4, 0.03 and 0.002 μg g−1, respectively.  相似文献   

14.
Abstract

This article demonstrates the first application of a copper-based porous coordination polymer (BTCA-P-Cu-CP) as a carbon paste electrode (CPE) modifier for the detection of malathion. The electrochemical behavior of BTCA-P-Cu-CP/CPE was explored using cyclic voltammetry (CV) while chrono-amperometry methods were applied for the analytical evaluation of the sensor performance. Under optimized conditions, the developed sensor exhibited high reproducibility, stability, and wide dynamic range (0.6–24?nM) with the limits of detection and sensitivity equal to 0.17?nM and 5.7 µAnMcm?1, respectively, based on inhibition signal measurement. Furthermore, the presence of common coexisting interfering species showed a minor change in signals (<4.4%). The developed sensor has been applied in the determination of malathion in spiked vegetable extracts. It exhibited promising results in term of fast and sensitive determination of malathion in real samples at trace level with recoveries of 91.0 to 104.4%. (RSDs < 5%, n?=?3). A comparison of the two studied techniques showed that the HPLC technique is unable to detect malathion when the concentration is lower than 1.8?µM while 0.006 µM is detected with appropriate RSDs 0.2–5.2% (n?=?3) by amperometric method. Due to the high sensitivity and selectivity, this new electrochemical sensor will be useful for monitoring trace malathion in real samples.  相似文献   

15.
Ambient aerosols were sampled at three selected sites in the coastal region of central Taiwan to obtain composition data for use in receptor modeling. All the samples were analyzed for 20 elements with an x&#x0002D;ray fluorescence spectrometer. The mass percentage of sulfates in particle samples was determined by ion chromatography, and mass percentages of elemental carbon (EC) and organic carbon (OC) were determined by an elemental analyzer.

Because the three sampling sites were located within 25 km of each other, the average chemical compositions were similar for particle samples taken at the three sites on the same day. However, the variation in composition from day to day was significantly influenced by wind direction and change in local sources, such as the burning of agricultural wastes. The abundant species in the coarse fraction (2.5&#x0002D;10 µm) were Al (0.5&#x0002D;4.0 µg/m3), Cl (0.1&#x0002D;4.8 µg/m3), Ca (0.2&#x0002D;3.4 µg/m3), Fe (0.2&#x0002D;2.8 µg/ m3), and K (0.1&#x0002D;1.4 µg/m3), while the abundant species in the fine fraction (<2.5 µm) were S (0.3&#x0002D;3.5 µg/m3), Cl (0.01&#x0002D;1.9 µg/ m3), K (0.04&#x0002D;0.98 µg/m3), organic carbon (0.01&#x0002D;10.5 µg/m3), elemental carbon (0&#x0002D;10.7 µg/m3), and sulfates (1.2&#x0002D;15.7 µg/m3).

Calculations for source apportionment were carried out using the CMB7 software developed by the U.S. Environmental Protection Agency (EPA). The main sources for the coarse fraction of ambient aerosols in the region were found to be marine aerosol, coal and fuel oil combustion, burning

of agricultural wastes, and paved road dust. The main sources for the fine fraction were burning of agricultural wastes, diesel exhaust, coal and oil combustion, and sulfates. Source apportionment for the fine fraction was relatively sensitive to the types of sources selected for calculations and the compositions of the sources. The problem can be ameliorated by careful examination of possible sources and by use of local source profiles.  相似文献   

16.
Ambient aerosols were sampled at three selected sites in the coastal region of central Taiwan to obtain composition data for use in receptor modeling. All the samples were analyzed for 20 elements with an x&#x002D;ray fluorescence spectrometer. The mass percentage of sulfates in particle samples was determined by ion chromatography, and mass percentages of elemental carbon (EC) and organic carbon (OC) were determined by an elemental analyzer.

Because the three sampling sites were located within 25 km of each other, the average chemical compositions were similar for particle samples taken at the three sites on the same day. However, the variation in composition from day to day was significantly influenced by wind direction and change in local sources, such as the burning of agricultural wastes. The abundant species in the coarse fraction (2.5&#x002D;10 µm) were Al (0.5&#x002D;4.0 µg/m3), Cl (0.1&#x002D;4.8 µg/m3), Ca (0.2&#x002D;3.4 µg/m3), Fe (0.2&#x002D;2.8 µg/ m3), and K (0.1&#x002D;1.4 µg/m3), while the abundant species in the fine fraction (&#x003C;2.5 µm) were S (0.3&#x002D;3.5 µg/m3), Cl (0.01&#x002D;1.9 µg/ m3), K (0.04&#x002D;0.98 µg/m3), organic carbon (0.01&#x002D;10.5 µg/m3), elemental carbon (0&#x002D;10.7 µg/m3), and sulfates (1.2&#x002D;15.7 µg/m3).

Calculations for source apportionment were carried out using the CMB7 software developed by the U.S. Environmental Protection Agency (EPA). The main sources for the coarse fraction of ambient aerosols in the region were found to be marine aerosol, coal and fuel oil combustion, burning of agricultural wastes, and paved road dust. The main sources for the fine fraction were burning of agricultural wastes, diesel exhaust, coal and oil combustion, and sulfates. Source apportionment for the fine fraction was relatively sensitive to the types of sources selected for calculations and the compositions of the sources. The problem can be ameliorated by careful examination of possible sources and by use of local source profiles.  相似文献   

17.
A rapid and sensitive liquid chromatography tandem mass spectrometry (LC/MS/MS) method for the determination of trace dioctyl sulfosuccinate (DOSS) concentrations in seawater samples has been established. The method is well suited to aquatic environment impact monitoring following application of the dispersant Corexit EC9500A. Linearity of the method was demonstrated down to 0.05 ng/mL?1 (0.05 µgL?1) DOSS in seawater, with a 2.4% relative standard deviation precision for preparation replicates. A US EPA method limit of detection of <0.02 ng/mL?1 (<0.02 µgL?1) was calculated and specificity was confirmed by monitoring of two qualifier ions at 291.1 m/z and 227.1 m/z. These transitions were confirmed by QToF analysis to be associated with the DOSS precursor ion at 421.2 m/z. For application to seawater samples and samples containing oil particulates, a practical and repeatable calibration range of 0.5 ng/mL?1 (0.5 µgL?1) to 25.0 ng/mL?1 (25.0 µgL?1) DOSS is reported. The method was shown to have excellent precision and accuracy, with a consistent ≤1.6% relative standard deviation for system suitability standards at 0.5 ng/mL?1 (0.5 µgL?1) and linear weighted (1/x) regression coefficients of determination ≥0.995. The surfactant nature of the analyte is discussed in relation to detection limit and loss of analyte. Speculation of a relationship between DOSS in association or aggregation with divalent cations, such as Ca2+ present in salt water and hard water, is suggested. The consequent effects on cell ionic balance and membrane function are discussed.  相似文献   

18.
A procedure was developed for the 24-h determination of SO2 and CO2 in effluent gas from fossil fuel combustion sources. Laboratory experiments were conducted to test absorption of SO2 in hydrogen peroxide solution and absorption of CO2 by sodium hydroxide on an inert substrate at expected ambient temperatures of 15 to 45°C. Isopropyl alcohol cannot be used to trap sulfuric acid and particulates because it permeates the sampling train and prevents complete absorption of CO2. Elemental analysis of stack particulates revealed that at least 31 elements were present. Iron and other elements interfered with SO2 analysis. These particulates were completely removed by a heated borosilicate glass filter. Both laboratory and field experiments showed that molecular sieves are a promising alternative for CO2 absorption. Statistical evaluation of data collected at three units equipped with flue gas desulfurization scrubbers proved that the new procedure is accurate and precise.  相似文献   

19.
Organochlorine pesticides present in sewage sludge can contaminate soil and water when they are used as either fertilizer or agricultural soil conditioner. In this study, the technique solid–liquid extraction with low temperature purification was optimized and validated for determination of ten organochlorine pesticides in sewage sludge and soil samples. Liquid–liquid extraction with low temperature purification was also validated for the same compounds in water. Analyses were performed by gas chromatography-mass spectrometry operating in the selective ion monitoring mode. After optimization, the methods showed recoveries between 70% and 115% with relative standard deviation lower than 13% for all target analytes in the three matrices. The linearity was demonstrated in the range of 20 to 70 µg L?1, 0.5 to 60 µg L?1, and 3 to 13 µg L?1, for sludge, soil, and acetonitrile, respectively. The limit of quantification ranged between 2 and 40 µg kg?1, 1 and 6 µg kg?1, and 0.5 µg L?1 for sludge, soil, and water, respectively. The methods were used in the study of pesticide lixiviation carried out in a poly vinyl chlorine column filled with soil, which had its surface layer mixed with sludge. The results showed that pesticides are not leached into soil, part of them is adsorbed by the sewage sludge (4–40%), and most pesticides are lost by volatilization.  相似文献   

20.
离子选择电极分析法测定标样中氟化物的不确定度评定   总被引:1,自引:0,他引:1  
陆军  杨仁燕 《污染防治技术》2006,19(6):47-48,72
通过对离子选择电极法测定标样中氟化物的过程研究,分析了该方法测量不确定度的来源,给出了相对不确定度分量,得出测量扩展不确定度的结果。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号