首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 187 毫秒
1.
An electrostatic precipitator, furnished on a 500-Mw tan-gentially-fired steam generator burning coal, was to collect 99.6% of the fly ash being generated in the furnace of this unit. Preliminary measurements indicated that the installation was not meeting its collection guarantee. Precipitator outlet flue dust distribution indicated that poor gas flow distribution might be one of the causes of the low performance. When observation ports were installed in the outlet flue to permit a direct visual evaluation of the problem, it was found that high velocity jets were present in the collecting electrodes, and that hopper sweepage was present. A model study along with velocity distribution measurements of the installation were authorized. Flow analysis indicated that the field and model correlated well. Extensive changes were made in the model, which eliminated or minimized the high velocity jets and hopper sweepage. After these changes were made in the field installation, it was able to achieve the required dust collection efficiency.  相似文献   

2.
Dioxin, furan and combustion gas data from test programs conducted at the Pitts field, Prince Edward Island, and Peekskill municipal solid waste incinerators were compared to identify similar and discrepant results. Dioxin and furan concentrations sampled upstream of air pollution control devices are related to a variety of combustion gas variables monitored in the high temperature zones of the incinerators. The effects of temperature, excess oxygen, carbon monoxide, hydrochloric acid gas, flue gas moisture, particulate loading and refuse moisture and PVC content are discussed. Conclusions are made and future research needs are discussed.  相似文献   

3.
烟气和粉尘性质对除尘效率影响的仿真研究   总被引:1,自引:0,他引:1  
应用欧拉-拉格朗日多相流模型对影响电除尘器内部气流分布的烟气含尘浓度、烟气湿度、粉尘粒径及真密度等因素进行了数值仿真。分析了烟气和粉尘性质对除尘效率的影响。由于在仿真过程中考虑了烟气特性和粉尘性质等因素,不仅可获得各因素对气流分布均匀性的影响,而且仿真结果更能反映电除尘器气流分布的实际情况。提出的烟气和粉尘性质仿真方法可以为电除尘器除尘效率分析提供新的途径。  相似文献   

4.
A nonequilibrium-reaetion model is developed to predict the flue gas composition of an incinerator for solid waste combustion and gasification. The model may also be effectively utilized to predict the composition of exit gas from the primary chamber of an incinerator where invariably substoichiometrie combustion conditions exist The model assumes that the drying and pyrolysis of waste occurs in sequence followed by combustion of devolatilized gas and residue separately. The model is applied to the combustion of pine wood, and the flue gas compositions are computed as a function of operating parameters such as temperature (1100 to 1500 K), initial moisture content (0 to 40 percent), and percentage excess air (up to 100 percent). The model is extended to include substoichiometric combustion (to simulate the gasification process without steam injection) to compare its predictions with the available experimental data. The general agreement of theory and experiment is good.  相似文献   

5.
If many homeowners convert to solid fuels for heating, residential flue gases will be a large source of air pollution. Control of this pollution requires an inexpensive, reliable, and effective method of flue gas treatment. One such method is to force flue gases through soil beds. Such soil treatment removes all detectable smoke, odor, and polynuclear organic matter (POM), up to 97% of the CO, and at least 97% of the SO2 from flue gases of wood and coal combustion. The technique is low cost, reliable, almost maintenance-free, and also appears suitable for other small point sources of air pollution.  相似文献   

6.
Environmental Science and Pollution Research - SO3 in the copper smelting flue gas not only causes serious corrosion in heat exchange and dust collection equipment but also increases the amount of...  相似文献   

7.
烟气脱硫及硫资源化新工艺   总被引:2,自引:1,他引:2  
介绍了资源化法烟气脱硫技术的工艺原理和工艺流程.相关试验表明,资源化法烟气脱硫技术具有脱硫效率高、设备投资省、运行费用低、可靠性高、操作简便、实现硫资源的回收利用等优点.  相似文献   

8.
文中介绍了一种炉窑烟气调质、烟气除尘、烟气脱硫在一个单体结构中的一体化装置和在烟气除尘脱硫技术上的应用,并对该脱硫除尘装置与传统的半干法烟气脱硫除尘装置进行了比较。  相似文献   

9.
Concepts for controlling SO2 from fossil fuels can be separated into two main categories: (1) Residual and vacuum gas oil desulfurization and (2) Flue gas desulfurization. The Kiyoura-T.I.T. process confines itself to the desulfurization of flue gas. It employs vandium oxide as a catalyst which oxidizes the sulfur dioxide to trioxide, followed by a gaseous phase reaction of ammonia. The end product, ammonium sulfate is removed by an electrostatic precipitator. (The details were presented at annual meetings of APCA in 1966 and 1967 as 1 and II.) Flue gas is passed through cyclone and dust filter to remove dust. Under normal operating conditions almost all of the dust is removed at the filters. The author carried out experiments to determine whether there was any effect on the activity of the catalyst, assuming that a portion of the dust escapes into the stream along the flue. It has been generally accepted that in fuel oil firing steam power plants, about 100 mg./nm3 of dust including carbon, hydrocarbon, and ash are normally contained in the flue stream. The carbon and hydrocarbon is oxidized readily at the filters and exists only as ash. An amount of ash equivalent to the amount assumed to have settled on the catalyst over a period of 3–12 months, was placed on the catalyst, and experiments were carried out. The SO2 conversion efficiency was measured and found to be over 93%. The results showed that at the actual operational temperature of 450°C, ash had practically no effect at all.  相似文献   

10.
Energy recovery from refuse derived fuels (RDF) and packaging derived fuels (PDF) is one option in integrated waste management. Nine RDF and PDF co-combustion tests with peat and coal in a circulating fluidized bed boiler were carried out in this work. Heavy metal emissions in flue gas and fly ash were measured. Multivariate data analyses were used to find out the most important parameters affecting metal emissions in the flue gas.

The results showed that total heavy metal emissions were low. Although RDF and PDF had more heavy metals than peat and coal, the multivariate data analysis showed that an increase of the RDF or PDF share in the fuel mixture up to 20% did not correlate directly with the metal emissions in the flue gas. Distribution of Cd, Cu, Zn and Sn between flue gas and fly ash correlated with each other. Injection of limestone to bind sulphur and chlorine did not have a significant effect on heavy metal emissions in the flue gas. Heavy metals concentrated on the fly ash, but all fly ashes passed the EPA-TCLP tests.  相似文献   


11.
Choi KI  Lee DH  Osako M  Kim SC 《Chemosphere》2007,66(6):1131-1137
Wet scrubber is one of the most conventional types of air pollutant control devices (APCDs), which is specially designed to treat dust and acidic gases in the flue gas simultaneously. In spite of its outstanding ability to control them, however, wet scrubbers have been considered as potential contaminant sources that may increase PCDD/DF concentrations in the flue gas. In this study, we investigated the change of PCDD/DF concentrations at the inlets and outlets of seven wet scrubbers, and compared them with other published data. With a multi-regression analysis of dust concentrations and temperature at the inlets and outlets of given wet scrubbers, we developed an empirical model to understand factors dominating the change of PCDD/DF concentrations. As a result, we confirmed that the changes of PCDD/DF concentrations in wet scrubbers are closely related to their concentrations at the inlets, which would usually be determined by the type of APCDs installed upstream of the wet scrubber.  相似文献   

12.
以改进后的双循环多级水幕塔对烟气进行除尘脱硫性能的研究,利用双循环不同pH值控制的优点和多级水幕的效果,增加气液接触面积和传质动力,提高SO2吸收效果。在正交实验的最佳运行工况基础上,实验从烟气流量、上下两段pH、L/G和SO2进气浓度等方面进行单因素研究。结果表明,除尘效率维持在98%以上,进气SO2浓度在5 000 mg/m3以下时,脱硫率在93%以上。上段pH值为6、下段pH值为5、L/G在15左右的脱硫效率和运行工况最佳,无结垢现象发生。改进后的吸收塔具有良好的应用前景,实验结果对于现场脱硫设备的调试和运行有很好的参考价值。  相似文献   

13.
Gohlke O  Busch M 《Chemosphere》2001,42(5-7):545-550
The SYNCOM process involves oxygen enrichment of underfire air, recirculation of flue gas and a combustion control system using infrared thermography of the waste layer on the grate. At the demonstration plant in Coburg, operational reliability and plant availability using SYNCOM could be proven under real disposal conditions with a waste throughput of 7 t/h. Oxygen enrichment of the underfire air promotes the destruction of pollutants due to the high oxygen partial pressures and temperatures. This is then reflected in very low residual amounts of organic combustion by-products in the bottom ash and flue gas from the SYNCOM unit. The flue gas concentrations of organic pollutants are reduced, as compared with conventional operation, by over 35% (for CO, total hydrocarbons and PCDD/F) at the boiler outlet. As the flue gas flow is reduced by oxygen enrichment and flue gas recirculation, the resulting reduction in terms of kg of pollutant per Mg of waste is even higher. In the bottom ash, the level of organic residues is reduced, by 45% in the case of loss on ignition and by 55% in the case of TOC and dioxins (I-TE of PCDD/F). This is due to the higher oxygen partial pressures and the fuel bed temperature which is increased by 135 to 1200 degrees C. Other important features of the process include more intense sintering and thus improved immobilization of the bottom ash, as well as reduced flue gas and fly ash flows.  相似文献   

14.
The body of information presented in this paper is directed to those individuals concerned with the catalytic NOx removal reactor for a dirty (containing dust) flue gas. In the case of treating a dirty flue gas, the concentration of dust is the most important factor. While the dirty gas passes through the catalytic reactor, dust particles deposit and plug up the catalyst causing the reactor pressure loss to rise. As a result, the NOx reduction efficiency decreases more and more, and continuous operation becomes impossible. A new type of NOx removal reactor for dirty flue gas, the intermittent moving bed reactor, has been developed. The following characteristics have been evaluated: (1) method of calculating reactor pressure loss caused by dust particles, (2) static pressure distribution across the catalyst bed in the reactor, (3) method of evaluating uniform movement of catalyst and (4) reentrainment pattern of dust by catalyst movement. After carrying out various successful pilot plant tests, the information needed for construction and operation of a commercial plant has been developed.  相似文献   

15.
介绍了一种集多种湿法除尘技术之长于一体的新型组合式除尘装置,该装置不仅能有效地消除手烧锅炉燃烧时产生的烟尘,而且实现了除尘水的内循环,消除了其他湿式除尘器所带来的水的二次污染问题。  相似文献   

16.
介绍了一种集多种湿法除尘技术之长于一体的新型组合式除尘装置,该装置不仅能有效地消除手烧锅炉燃烧时产生的烟尘,而且实现了除尘水的内循环,消除了其他湿式除尘器所带来的水的二次污染问题。  相似文献   

17.
The nitrogen oxides (NOx) reduction technology by combustion modification which has economic benefits as a method of controlling NOx emitted in the combustion process, has recently been receiving a lot of attention. Especially, the moderate or intense low oxygen dilution (MILD) combustion which applied high temperature flue gas recirculation has been confirmed for its effectiveness with regard to solid fuel as well. MILD combustion is affected by the flue gas recirculation ratio and the composition of recirculation gas, so its NOx reduction efficiency is determined by them. In order to investigate the influence of factors which determine the reduction efficiency of NOx in MILD coal combustion, this study changed the flow rate and concentration of nitrogen (N2), carbon dioxide (CO2) and steam (H2O) which simulate the recirculation gas during the MILD coal combustion using our lab-scale drop tube furnace and performed the combustion experiment. As a result, its influence by the composition of recirculation gas was insignificant and it was shown that flue gas recirculation ratio influences the change of NOx concentration greatly. Implications: We investigated the influence of factors determining the nitrogen oxides (NOx) reduction efficiency in MILD coal combustion, which applied high-temperature flue gas recirculation. Using a lab-scale drop tube furnace and simulated recirculation gas, we conducted combustion testing changing the recirculation gas conditions. We found that the flue gas recirculation ratio influences the reduction of NOx emissions the most.  相似文献   

18.
The emission of polycyclic aromatic hydrocarbons (PAH) caused by municipal waste incineration varies according to waste composition and operating parameters such as furnace temperature and excess air. However, to obtain a sample sufficient to measure the emission of PAH at trace levels, it is necessary to operate the incinerator for many hours. Since during these lengthy periods it has not always been possible to maintain stable conditions, it is very difficult to determine the relationship between the emission and waste composition.

In our basic research, therefore, we used municipal waste with an artificially regulated composition for our combustion experiments, and by using an experimental Incinerator we examined the emission behavior of PAH with respect to changes in waste composition and combustion conditions. The following facts were revealed by the results: ? The PAH found in the flue gas were predominantly the more volatile compounds.

? When municipal waste was incinerated at over 850 °C, the concentration of PAH in the flue gas increased rapidly as the proportion of plastics in the waste increased from 0 to 24 percent.

? The elimination of plastics from municipal waste by separate collection and the improvement of combustion conditions can effectively diminish the emission of PAH.

  相似文献   

19.
Huber S  Haug LS  Schlabach M 《Chemosphere》2011,84(11):1686-1693
Polyfluorinated compounds (PFCs) are an extremely versatile class of compounds and are used in a variety of consumer applications and products. Recent studies have suggested that PFCs in indoor air and dust could act as sources of human exposure and outdoor air contamination. This study presents method development and analysis of a wide range of PFCs in dust and air using active sampling techniques with commercially available sampling equipment (forensic nozzles with filter housings for dust collection and polyurethane foam (PUF)-XAD2-PUF sandwich-tubes for air sampling) using both liquid and gas chromatography mass spectrometry. The developed method was validated and tested for applicability to analyze dust and air samples at both low and high concentrations (0.5 ng and 25 ng per analyte per air sample, respectively). Samples from private households and an office building were analyzed to explore differences in distribution patterns and concentrations. Perfluorooctane sulfonate, perfluorodecane sulfonate, perfluoroheptanoate, perfluorooctanoate and perfluorononanoate were observed in all samples of dust from private households, in the range from 1 to 80.1 ng g−1. Fluorotelomer alcohols (FTOHs) were the predominant PFCs in indoor air samples with ∑FTOHs ranging between 4.7 and 17.9 ng m−3. The concentrations found in the present study are generally lower than those previously reported. This variation may be due to differences associated with geographical locations and lifestyles. However, use of different sampling techniques and strategies among studies can introduce large variations in PFC concentration found, making direct comparisons challenging.  相似文献   

20.
测定了流化床垃圾焚烧炉焚烧产生的飞灰、烟尘和烟气中的2,3,7,8位氯取代二噁英同类物的含量及其毒性当量。结果表明,产生的二噁英主要存在于飞灰中,烟气中的含量很少。飞灰中二噁英总浓度和毒性当量分别为8.44ng/g和0.80ng/g,经过布袋除尘器后的烟尘和烟气中二噁英的浓度之和与毒性当量之和分别为0.34ng/m^3和0.02ng/m^3,而布袋除尘器前的烟尘和烟气中二噁英的浓度之和与毒性当量之和分别为40.78ng/m^3和3.0ng/m^3。飞灰和烟尘中2,3,7,8位氯取代二噁英同类物的分布相似,但是与烟气中2,3,7,8位氯取代二噁英同类物的分布差别较大。通过了解有毒二噁英同类物的分布,可以进一步优化流化床垃圾焚烧炉的焚烧条件,降低二噁英的排放量,减少垃圾焚烧对环境的污染。  相似文献   