首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), and polychlorinated biphenyls (PCBs) in human have been studied extensively; however, polychlorinated naphthalenes (PCNs) have been studied less widely. The mean concentrations of PCNs, PCDDs, PCDFs, and PCBs in 61 healthy human volunteers were 2170 pg/g lipid, 452 pg/g lipid, 116 pg/g lipid, and 120 ng/g lipid respectively, and the mean toxic equivalents (TEQs) contributed by PCNs, PCDDs, PCDFs, and PCBs were 5.88, 5.22, 5.48, and 5.33 pg/g lipid, respectively. PCNs contributed to 26.8% of the total TEQs. 1,2,3,7,8-PeCDD, 2,3,4,7,8-PeCDF, PCB126, and hepta-CN-73 accounted for >62% of the total TEQs in the human serum samples. The overall serum PCN homologue profiles of all subjects were dominated by tetra- and penta-CN homologues, and the most predominant individual congener was hepta-CN-73, which contributed 17.5% of the total serum PCN concentration. Enrichment of hepta-CN-73 in the human serum samples might be due to contributors from combustion sources.  相似文献   

2.
Homologue and congener profiles of polychlorinated biphenyls (PCBs), polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) in commercial PCBs formulations are key information for the source identification of PCBs contamination as well as for the risk assessment caused by potential exposure. The isotope dilution technology in combination with high resolution gas chromatography-high resolution mass spectrometry (HRGC/HRMS) has made the accurate determination of such profiles possible. So far, various commercial PCB formulations except Chinese products have been successfully determined. Two PCBs containing insulating oil samples from stored Chinese electrical capacitors have been determined with the same methodology for comparability. The total concentration PCBs in two oil samples were 790 000 μg g−1 and 720 000 μg g−1, respectively. TriCBs, TetraCBs, and DiCBs were found to be most abundant. Concentration of dioxins contamination in two samples is 650-670 ngTEQ g−1, of which 69-71 ngTEQ g−1 from PCDD/Fs with the predominant congeners of 1,2,7,8-TeCDF; 2,3,7,8-TeCDF; 2,3,4,7,8-PeCDF and 1,2,3,7,8-PeCDF. The contributions of DL-PCBs in total TEQ in both samples were more than 85%. The dioxin-like toxicity in insulating oils contained in electrical capacitors could be considered receive attention as an important dioxins source if such wastes are not managed in an environmentally sound manner.  相似文献   

3.
Noma Y  Yamamoto T  Giraud R  Sakai S 《Chemosphere》2006,62(7):1183-1195
In the first known study to characterize the emissions of polychlorinated naphthalenes (PCNs), polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), and dioxin-like polychlorinated biphenyls (dl-PCBs) from the thermal treatment of wastes containing PCNs, the formation and decomposition behavior of these pollutants was investigated both at laboratory scale and at plant scale. Exhaust gas measurements from laboratory-scale combustion of rubber belts containing PCNs (FB belts) were used as the basis for calculations predicting that the incremental dioxin toxic equivalency (TEQ) emissions from municipal solid waste (MSW) incinerators would be less than 0.1 ng/m3 N. In order to directly examine co-incineration of FB belts with MSW and to address potential differences between the laboratory experiment and full-scale MSW incinerators, experiments were conducted using a larger scale thermal treatment test facility with sampling and analysis at several points in the thermal treatment process. Congener specific analysis of PCNs clearly showed that both destruction and synthesis simultaneously occurred during combustion in the kiln. Most of the PCNs were destroyed by secondary combustion, and almost all PCNs were removed after flue gas treatment. Almost all PCDDs/DFs were synthesized as by-products of kiln combustion, most of them were destroyed by the secondary combustion, and almost all dioxins (PCDDs/DFs and dl-PCBs) were removed after flue gas treatment. The TEQ emission levels were less than 0.1 ng/m3 N for all plant-scale tests, and differences in TEQ emission levels were very small. Adding wastes containing PCNs to MSW will not influence thermal treatment emissions to the environment from modern solid waste incinerators.  相似文献   

4.
We measured the concentrations of polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), dioxin-like polychlorinated biphenyls (PCBs), and non-dioxin-like PCBs in paired samples of blood and breast milk collected from 67 secundiparas in Sapporo City, Japan, and combined this data with those of the 30 secundiparas previously measured. The arithmetic mean total toxic equivalents (TEQ-WHO) concentrations of PCDDs, PCDFs, non-ortho PCBs, and mono-ortho PCBs in blood and breast milk of the 97 secundiparous subjects were 3.0-23 (mean: 13, median: 14) and 2.7-20 (mean: 8.6, median: 8.5) pg TEQ g−1 lipid, respectively. The sums of the concentrations of 56 non-dioxin-like PCB congeners that were measured in the subjects’ blood and breast milk were 16-326 (mean: 107, median: 100) and 12-252 (mean: 73, median: 67) ng g−1 lipid, respectively. The partitioning ratios of individual congeners of PCDDs, PCDFs, dioxin-like PCBs, and non-dioxin-like PCBs from blood to breast milk in secundiparas were almost the same as those of primiparas that have been recently reported, suggesting that the partitioning ratios of these compounds from maternal blood to breast milk in women is little affected by delivery. Furthermore, the partition of PCB congeners with chlorine at the 2-, 3-, 4′-, and 5-positions or the 2-, 4-, 4′-, and 5-positions of the biphenyl ring from the blood to the breast milk tended to occur at a higher level than that of other congeners. In particular, the levels of tetraCB-74 and hexaCB-146 in the breast milk for both primiparous and secundiparous mothers were slightly higher than those in the blood.  相似文献   

5.
This report presents our results in a low-temperature mechanochemical hydrodechlorination process applied to fly ash coming from a municipal waste incinerator in order to efficiently remove all traces of PCDDs, PCDFs and PCBs. We found that the most suitable degradation agent is a mixture of metallic calcium and calcium oxide. A sample of fly ash presenting a TEQ of 5200 pg g−1 was completely detoxified (no traces of PCDDs, PCDFs and PCBs detected) after ball-milling at 400 rpm over night.  相似文献   

6.
In a laboratory-scale combustion reactor, flue-gas samples were collected at two temperatures in the post-combustion zone, 700 °C and 400 °C, using two different water-cooled sampling probes. The probes were the cooled probe described in the European Standard method EN-1948:1, referred to as the original probe, and a modified probe that contained a salt/ice mixture to assist the cooling, referred to as the sub-zero probe. To determine the efficiency of the cooling probes, internal temperature measurements were recorded at 5 cm intervals inside the probes. Flue-gas samples were analyzed for polychlorinated dibenzo-p-dioxin and dibenzofurans (PCDD/Fs). Samples collected at 700 °C using the original cooling probe showed higher concentrations of PCDD/Fs compared to samples collected using the sub-zero probe. No significant differences were observed between samples collected at 400 °C. The results indicated that artifact formation of PCDD/Fs readily occurs during flue-gas sampling at high temperatures if the cooling within the probe is insufficient, as found for the original probe at 700 °C. It was also shown that this problem could be alleviated by using probes with an enhanced cooling capacity, such as the sub-zero probe.Although this may not affect samples collected for regulatory purposes in exit gases, it is of great importance for research conducted in the high-temperature region of the post-combustion zone.  相似文献   

7.
This study investigated the accumulation features and temporal trends of PCDD/Fs, dioxin-like PCBs (DL-PCBs) and non-dioxin-like PCBs (NDL-PCBs) in the blubber of Baikal seals collected in 1992 and 2005. DL-PCBs (480-3600 ng/g) and NDL-PCBs (980-35,000 ng/g) were dominant contaminants. Concentrations of PCDDs and PCBs in males were significantly higher than in females. In males, age-dependent accumulation was observed for PCDDs, mono-ortho PCBs and NDL-PCBs. PCDFs and non-ortho PCBs showed no such trends, implying that exposure of seals to these contaminants has been decreasing in recent years. No decreasing temporal trend was observed for PCDDs, mono-ortho PCBs and NDL-PCBs, suggesting that Baikal seals are still exposed to PCDDs and PCBs. TEQs of PCDDs and mono-ortho PCBs in seals collected in 2005 accounted for 62-77% of total TEQs. The TEQ levels in 40% of the specimens exceeded the threshold level for immunosuppression observed in harbor seals (209 pg/g).  相似文献   

8.
Emission factors for PCDD/PCDF determined from open combustion are used to estimate national emission budgets; therefore, it is important to have confidence in their accuracy. It has been suspected that artefacts may form due to the presence of hot metal surfaces of sampling equipment, thus skewing emission factors. In this study, emissions of PCDD/PCDF from open burning of forest biomass over a brick hearth were sampled. Five experiments were carried out using a portable sampler. Experiments were designed where the key variable, sample hood and inlet temperatures were manipulated. Other variables such as fuel origin, type and density were consistent. The measured concentration of PCDD/PCDF in the smoke samples ranged from 0.01 μg TEQ (t fuel)−1 at the lowest maximum hood temperature (185 °C) to 15 μg TEQ (t fuel)−1 at the highest maximum hood temperature (598 °C). when hood inlet temperatures exceeded 400 °C emission factors were significantly elevated and this is attributed to the formation of artefacts that can cause the over estimation of emission factors. The increase in hood temperature also resulted in a change in the PCDD/PCDF congener and homologue profile of the emissions. For example at the lowest temperature (Fire 1) the PCDD/PCDF ratio measured was 50:1, whereas at the highest temperature (Fire 5) this ratio was about 0.53:1. When the sampler hood and inlet temperatures were kept in the normal operating range of <200 °C, emission factors were comparable to those observed in many previous studies in Australia with emissions dominated by PCDD.  相似文献   

9.
Polychlorodibenzo-p-dioxins (PCDDs), polychlorodibenzofurans (PCDFs), polychloronaphthalenes (PCNs) and coplanar PCBs were measured in surface sediments from 18 lake areas in Central Finland. Toxic 2, 3, 7, 8-substituted PCDD and PCDF congeners occurred at low levels (<20 − 230 pg/g dw). PCNs appeared at few ng/g (total PCNs) levels. Pulp mills or any other local sources could not be associated with the sedimented PCDDs, PCDFs and PCNs. Coplanar PCB congeners 77 and 105 (IUPAC Nr) were generally found at 20–550 pg/g levels. The most toxic congener 126 was measured (110 pg/g) only at one area near a local PCB leakage. Pulp mill originated aromatic chlorocompounds which coelute with PCDDs and PCDFs in clean up, probably alkyl polychlorobibenzyls (R-PCBBs) appeared at ng/g levels and showed a clear gradient dowstreams from pulp mill effluent points.  相似文献   

10.
Suspended sediments from the Detroit River were collected in 1999 and 2000 using sediment traps at sites ranging from western Lake Erie to southern Lake St. Clair and analyzed to determine the spatial distributions of contaminants including polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDDs/PCDFs), dioxin-like PCBs (DLPCBs) and polychlorinated naphthalenes (PCNs). Concentrations of all three contaminant classes were clearly elevated at sites in the lower reaches of the river in the Trenton Channel. The potential influence of the Trenton Channel as a source of contamination to western Lake Erie was further evidenced by PCDD/PCDF homologue profiles, which indicated a contribution from chemical manufacturing in addition to the normal background combustion profile. Toxic equivalents (TEQs) for PCDDs/PCDFs generally exceeded those for DLPCBs; combined total TEQs in July 2000 for these two compound classes ranged from 2.30 pg/g in southern Lake St. Clair to 306 pg/g at a station just downstream of the outflow of Monguagon Creek in the Trenton Channel. The spatial distribution of PCN contamination was similar to that of PCDDs/PCDFs and DLPCBs, with the highest level of total PCNs (8200 ng/g) detected at a site in the Trenton Channel near Elizabeth Park; TEQs for PCNs in the Trenton Channel ranged from 73 to 3300 pg/g. The data indicate that PCNs represent a significant contribution to dioxin-like biological activity in Detroit River suspended sediments.  相似文献   

11.
Five fluidized bed incinerators combusting municipal solid waste were assessed for the impact of coplanar PCBs on total TEQ emission. In 17 stack measurements, the coplanar PCBs contributed on average less than 3% to total TEQ with a maximum contribution of 7.5% to total TEQ in one measurement. Differences in the design of the flue gas cooling section did not show an effect on the impact of coplanar PCBs on total TEQ. The effect of emission control devices on the impact of coplanar PCBs on the total TEQ was studied in more detail at one incinerator. The relative contribution of PCBs to total TEQ increased along the flue gas line. This was caused by a slightly higher removal efficiency for TEQ relevant PCDDs/PCDFs compared to coplanar PCBs by the bag filters and a higher destruction efficiency for PCDDs/PCDFs compared to PCBs by the SCR catalyst. Additionally, the removal efficiencies of the emission control devices (bag filters and catalyst) for other chlorinated aromatic compounds which have been proposed as TEQ indicator compounds (polychlorinated benzenes and polychlorinated phenols) were compared with those for PCDDs/PCDFs and coplanar PCBs. Removal efficiencies for polychlorinated benzenes or polychlorinated phenols considerably differed from those of PCDD/PCDF and coplanar PCBs. Implications for TEQ assessments using indicator compounds as proposed in the literature are discussed.  相似文献   

12.
In this paper the results of sampling for trace chlorinated organics at two municipal refuse incinerators in Ontario are presented. The information may be of Interest to individuals concerned with the assessment of PCDD/PCDF (polychlorinated dibenzo-p-dioxin/polychlorinated dibenzofuran) emissions from incineration of refuse and their impact on the energyfrom- waste program. PCDDs, PCDFs, PCBs (polychlorinated biphenyls), CBs (chlorobenzenes) and CPs (chlorophenols) were quantified in all process streams including refuse, ash and stack emissions. Manual sorting of refuse and collection of ash samples were carried out simultaneously with three 24-hour continuous stack sampling tests at each plant. The results suggested that the total output of PCDDs and PCDFs varied proportionately with their input at both incinerators. However, the input of PCDDs/PCDFs could not account for their total output. The chemistry of PCDDs/PCDFs in the input and output streams were different in that only heptachlorinated and octachlorinated species were present in significant quantities in the refuse while lower chlorinated species were predominant in stack emissions and ash streams. There was no correspondence between the Input of PCBs/CBs/CPs and the output of PCDDs/PCDFs. The output of PCDDs/PCDFs, however, varied Inversely with the total output of PCBs/CBs/CPs, suggesting that the latter compounds could have been partially responsible for the formation of PCDDs and PCDFs. The PCDF emissions were also affected by combustion conditions; they were higher in magnitude and consisted of predominantly tetrachlorinated and pentachlorinated species at the plant where the combustion temperatures were lower.  相似文献   

13.
P.E. desRosiers  A. Lee 《Chemosphere》1986,15(9-12):1313-1323
PCBs, PCDDs, and PCDFs are subject to new regulations promulgated under the Toxic Substances Control Act and the Resource Conservation and Recovery Act. The finding of PCDDs and PCDFs in PCBs could restrict disposal options for PCBs. A review of major fire incidents in the U.S., indicates that PCDDs have been found only in the Binghamton, N.Y., transformer fire incident. Laboratory combustion studies further support PCDFs formation from PCBs and PCDDs from chlorobenzenes. No PCDDs were found in analyses of fluids from transformers involved in transformer fire incidents. PCDFs do not appear to increase in PCBs askarel fluids from normal usage in electrical equipment.  相似文献   

14.
PCDDs/PCDFs, dl-PCBs and HCB in the flue gas from coal fired CFB boilers   总被引:1,自引:0,他引:1  
The aim of the project was to measure the actual emissions of polychlorinated dibenzodioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), dioxin-like polychlorinated biphenyls (dl-PCBs) and hexachlorobenzene (HCB) from four selected power plants in Poland in order to update the national inventory of PCDDs/PCDFs emission. Relatively low PCDDs/PCDFs as well as dl-PCBs concentrations in flue gas obtained in measurements in this study for four different circulated fluidized bed (CFB) boilers indicate practical absence of any hazards caused by PCDDs/PCDFs emission from these units. The results of PCDDs/PCDFs determination obtained in this study indicate that hard coal combustion in large CFB in the four central heating plants (CHP) is not a significant source of PCDDs/PCDFs emission to the environment even if operated by co-firing of waste coal. PCDDs/PCDFs concentration in flue gases as well as emission factors were recorded in the range of 0.012-0.060ngI-TEQ/m(n)(3) and 7.51-46.4mugI-TEQ/TJ, respectively. Dl-PCBs concentration was practically below the LOQ=0.006ng WHO-PCB TEQ/m(n)(3) in all experiments. HCB concentration as well as emission factors were recorded in the range of 11.5-42.0ng/m(n)(3) and 6.19-26.7mg/TJ, respectively, where the highest value was obtained for co-firing of waste coal, however. Obtained in this work emission factors will be used for national emission inventory purposes instead of the factors proposed by Toolkit or taken from previous measurements. However, consideration should be given to the fact that the measurements in most cases are related to single installations. Therefore, the need for further development of national factors for the power generation industry in Poland is desired.  相似文献   

15.
Hogarh JN  Seike N  Kobara Y  Habib A  Nam JJ  Lee JS  Li Q  Liu X  Li J  Zhang G  Masunaga S 《Chemosphere》2012,86(7):718-726
A comprehensive congener specific evaluation of polychlorinated biphenyls (PCBs) and polychlorinated naphthalenes (PCNs) in the atmosphere was conducted across East Asia in spring 2008, applying polyurethane foam (PUF) disk passive air sampler (PAS) as monitoring device. Mean concentrations derived for Japan, China and Korea were 184 ± 24, 1100 ± 118, and 156 ± 20 pg m−3 for ∑202 PCBs, and 9.5 ± 1.5, 61 ± 6, and 16 ± 2.4 pg m−3 for ∑63 PCNs, respectively. Relative to reported data from 2004, the present results suggest that air PCBs concentrations have not changed much in Japan and Korea, while it has increased by one order of magnitude in China. From principal component analysis, combustion emerged highly culpable in contemporary emissions of both PCBs and PCNs across the East Asian sub-region. Another factor derived as important to air PCBs was re-emissions/volatilization. Signals from PCBs formulations were also picked, but their general importance was virtually consigned to the re-emissions/volatilization tendencies. On the contrary, counterpart PCNs formulations did not appear to contribute much to air PCNs.  相似文献   

16.
Both long duration (>6 h) and high temperature (up to 139 °C) sampling efforts were conducted using ambient air sampling methods to determine if either high volume throughput or higher than ambient air sampling temperatures resulted in loss of target polychlorinated dibenzodioxins/dibenzofurans (PCDDs/PCDFs) from a polyurethane foam (PUF) sorbent. Emissions from open burning of simulated military forward operating base waste were sampled using EPA Method TO-9A for 185 min duration using a filter/PUF/PUF in series combination. After a 54 m3 sample was collected, the sampler was removed from the combustion source and the second PUF was replaced with a fresh, clean PUF. An additional 6 h of ambient air sampling (171 m3) was conducted and the second PUF was analyzed to determine if the PCDD/PCDF transferred from the filter and the first PUF. Less than 4.4% of the initial PCDD/PCDF was lost to the second PUF. To assess the potential for blow off of PCDD/PCDF analytes during open air sampling, the mobility of spiked mono- to hepta-PCDD/PCDF standards across a PUF sorbent was evaluated from ambient air temperatures to 145 °C with total volumes between 600 L and 2400 L. Lower molecular weight compounds and higher flow amounts increased release of the spiked standards consistent with vapor pressure values. At 600 L total sampled volume, the release temperature for 1% of the tetra-CDD (the lowest chlorinated homologue with a toxic compound) was 87 °C; increasing the volume fourfold reduced this temperature to 73 °C.  相似文献   

17.
Liver of blue shark (Prionace glauca) specimens from the South-Eastern Mediterranean Sea were analyzed for the presence of polychlorinated biphenyls (PCBs), including coplanar congeners, polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs). PCBs were the dominant chemicals, followed by PCDFs and PCDDs. The pattern of PCB congener concentrations in the hepatic tissue was dominated by higher chlorinated compounds. The specific profile of toxic PCDD/F congeners was characterized mainly by 2,3,7,8-TCDF and 2,3,7,8-TCDD, followed by 1,2,3,6,7,8-HxCDD and 2,3,4,6,7,8-HxCDF. The total 2,3,7,8-TCDD toxic equivalent (TEQs) was 149 pg g−1 lipid wt. The profile of TEQ shows that PCDDs present the greatest risk to this species contributing to total toxicity with a percentage approximately of 60%, while the contribution of PCDFs and DL-PCBs is almost the same being 22.4% and 21.6%, respectively. Further investigations are urgently needed to characterize the PCDD/Fs contamination levels not only in elasmobranch fish but in all Mediterranean marine biota.  相似文献   

18.
The association between dietary patterns and blood dioxin levels has not been fully investigated. The present study population consisted of 755 men and 901 women (aged 15-73 years) living in 90 different areas of 30 prefectures of Japan. Dietary habits were assessed by inquiring about the consumption frequency of 28 foods, food groups and beverages. In addition, the blood levels of 29 polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzo-furans (PCDFs), and dioxin-like polychlorinated biphenyl (DL-PCBs) congeners were determined by high-resolution gas chromatography/mass spectrometry. The median total toxicity equivalent (TEQ) in the blood, which was calculated on the basis of the toxicity equivalency factors of WHO (2005), was 16 pg TEQ g−1 lipid. Principal component analysis identified five dietary patterns: Healthy diet (high intake of vegetables and fruits); Meat/High fat intake (high intake of meat, meat products, and eggs); Seafood and Alcohol (high intake of fish, shellfish, and alcoholic beverages); Miscellaneous; and Milk products and Alcohol intake (high intake of milk, Milk products, and alcoholic beverages). After adjusting for sex, age, body mass index, and smoking habits, the Seafood and Alcohol pattern scores were significantly related to higher blood levels of total TEQ and PCDDs/PCDFs/DL-PCBs, and the Milk products and Alcohol pattern scores were correlated with higher blood levels of DL-PCBs. More detailed analysis showed that the intake frequencies for alcoholic beverages and seafood were independently and positively associated with total TEQ and the TEQ of PCDFs and DL-PCBs. The association between alcoholic beverage intake and PCDDs was also significant. Analysis of dietary patterns may be useful for identifying the dietary characteristics of individuals with a high dioxin body burden.  相似文献   

19.
Accumulated maternal dioxins are passed onto the fetus and neonate via the placenta and maternal milk. In Japan in 1968, an accidental human exposure to rice oil contaminated with polychlorinated biphenyls (PCBs) and other dioxin-related compounds, such as polychlorinated dibenzofurans (PCDFs), led to development of Yusho oil disease. We investigated differences in blood dioxin concentrations in mother-children pairs affected by the Yusho incident. From 2002 to 2008, blood samples were collected from 26 pairs of Yusho mothers and their children (19 mothers, 26 children). Specific congeners of seven polychlorinated dibenzo-p-dioxins (PCDDs), ten PCDFs, and four non-ortho PCBs were analyzed. The children had significantly lower TEQ concentrations of PCDDs, PCDFs, and coplanar PCBs compared to their mothers. The mother-child difference in blood concentrations varied with the congeners; the largest for 2,3,4,7,8-pentaCDF and the smallest for 1,2,3,4,6,7,8-heptaCDD. The level for 2,3,4,7,8-pentaCDF, which characterizes Yusho oil disease, was approximately 17-30 times higher in the mothers than in the general population, whereas there were no significant differences between children in the formula-fed group and the general population. In contrast, the mean level for 2,3,4,7,8-pentaCDF in the breast-fed group was approximately 1.5 times, (range 0.5-6.5 times) higher than that in the general population. Over 30 years after the Yusho incident, the mean blood dioxin levels in the offspring were only a fraction of the levels in their mothers. This is more consistent with exposure via breast milk than via transplacental transfer in the Yusho incident.  相似文献   

20.
The catalytic effects of copper and iron compounds were examined for their behavior in promoting formation of chlorine (Cl2), the major chlorinating agent of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs), in an environment simulating that of municipal waste fly ash. Formation of Cl2 occurred as a result of a metal-catalyzed reaction of HCl with O2. Catalytic activity was greatest at a temperature of approximately 400 °C, supporting a theory of de novo synthesis of PCDDs and PCDFs on fly ash particles downstream of waste combustion.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号