Emission factors for PCDD/PCDF determined from open combustion are used to estimate national emission budgets; therefore, it is important to have confidence in their accuracy. It has been suspected that artefacts may form due to the presence of hot metal surfaces of sampling equipment, thus skewing emission factors. In this study, emissions of PCDD/PCDF from open burning of forest biomass over a brick hearth were sampled. Five experiments were carried out using a portable sampler. Experiments were designed where the key variable, sample hood and inlet temperatures were manipulated. Other variables such as fuel origin, type and density were consistent. The measured concentration of PCDD/PCDF in the smoke samples ranged from 0.01 μg TEQ (t fuel)−1 at the lowest maximum hood temperature (185 °C) to 15 μg TEQ (t fuel)−1 at the highest maximum hood temperature (598 °C). when hood inlet temperatures exceeded 400 °C emission factors were significantly elevated and this is attributed to the formation of artefacts that can cause the over estimation of emission factors. The increase in hood temperature also resulted in a change in the PCDD/PCDF congener and homologue profile of the emissions. For example at the lowest temperature (Fire 1) the PCDD/PCDF ratio measured was 50:1, whereas at the highest temperature (Fire 5) this ratio was about 0.53:1. When the sampler hood and inlet temperatures were kept in the normal operating range of <200 °C, emission factors were comparable to those observed in many previous studies in Australia with emissions dominated by PCDD.  相似文献   

2.
Lundin L  Aurell J  Marklund S 《Chemosphere》2011,84(3):305-310
The polychlorinated dibenzo-p-dioxin (PCDD) and polychlorinated dibenzofuran (PCDF) content of three fly ash samples with different elemental compositions from different municipal waste incinerators were analyzed before and after thermal treatment at 300 °C or 500 °C. Gas phase emissions during the treatments were also collected and analyzed. Substantial reductions in the total PCCD/F content of the ashes were observed after treatment at 500 °C, seemingly due to degradation rather than dechlorination. Treatment at 300 °C resulted in an increase in the PCDD/F content of the three ashes. Initial concentration of PCDD/F in the untreated ashes did not reflect the outcome of the treatment at the different temperatures. In addition, the composition of the ash was found to influence the rate of decomposition and formation of PCDD and PCDF during thermal treatment; the results showed that Cu, Fe, Ca and S play important roles in these processes.  相似文献   

3.
Taking into account current environmental concerns, the main objective of this work focused a national inventory aiming to estimate the amount of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/PCDF) released in Portugal in 2006. The methodology used was based on the Standardized Toolkit for Identification and Quantification of Dioxins and Furan Releases, developed by UNEP Chemicals, in 2005. The method allows the assessment of the amount of PCDD/PCDF released into the environment along five vectors involving air, water, land, products and residues. Facing some difficulties mainly regarding to the availability of data for some activities known to produce PCDD/PCDF, three scenarios (Sc1 to Sc3) corresponding to lower, central and upper estimates were established. The Sc1 scenario (lower estimate) includes the situations where in case of doubt or scarce information, reduced or none emission values were assumed, Sc2 refers to a central estimate, which is believed to be the most realistic for the Portuguese situation, while Sc3 corresponds to the worst case (upper estimate). The results obtained pointed out that the total amount of PCDD/PCDF emitted in Portugal during the period under analysis was in the range of 51.2-217.9 g TEQ year−1, with the most likely value of 95.2 g TEQ year−1 achieved under the Sc2 scenario. This study also showed that the methodology developed by UNEP Chemicals is a very simple one, and the main difficulty is the availability of data. The main indicators calculated in this study were 8.98 μg TEQ/(year person) by taking into account the total amount of PCDD/PCDF released, and 3.63 μg TEQ/(year person) when only air emissions were considered.  相似文献   

4.
Particle-bound polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) in ambient air were monitored together with particulate matter less than 10 μm (PM10) at three sampling sites of the Andean city of Manizales, Colombia; during September 2009 and July 2010. PCDD/Fs ambient air emissions ranged from 1 fg WHO-TEQ m−3 to 52 fg WHO-TEQ m−3 in particulate fraction. The PM10 concentrations ranged from 23 μg m−3 to 54 μg m−3. Concentrations of PM10 and PCDD/Fs in ambient air observed for Manizales - a medium sized city with a population of 380 000 - were comparable to concentrations in larger cities. The highest concentrations of PCDD/Fs and PM10 found in this study were determined at the central zone of the city, characterized by public transportation density, where diesel as principal fuel is used. In addition, hypothetical gas fractions of PCDD/Fs were calculated from theoretical Kp data. Congener profiles of PCDD/Fs exhibited ratios associated with different combustion sources at the different sampling locations, ranging from steel recycling to gasoline and diesel engines. Taking into account particle and gas hypothetical fraction of PCDD/Fs, Manizales exhibited values of PCDD/Fs equivalent to rural and urban-industrial sites in the southeast and center of the city respectively. Poor correlation of PCDDs with PM10 (r = −0.55 and r = 0.52) suggests ambient air PCDDs were derived from various combustion sources. Stronger correlation was observed of PCDFs with PM10. Poor correlation between precipitation and reduced PM10 concentration in ambient air (r = −0.45) suggested low PM10 removal by rainfall.  相似文献   

5.
Open burning of waste is the most significant source of polychlorinated dibenzo-para-dioxins and dibenzofurans (PCDD/PCDF) in many national inventories prepared pursuant to the Stockholm Convention on Persistent Organic Pollutants. This is particularly true for developing countries. Emission factors for POPs such as PCDD/PCDF, dioxin-like polychlorinated biphenyls (dl-PCB) and penta- and hexachlorobenzenes (PeCBz/HCB) from open burning of municipal solid waste in China and Mexico are reported herein. Six different waste sources were studied varying from urban-industrial to semi-urban to rural. For PCDD/PCDF, the emission factors to air ranged from 3.0 to 650 ng TEQ kg−1 waste and for dl-PCB from 0.092 to 54 ng TEQ kg−1 waste. Emission factors for PeCBz (17-1200 ng kg−1 waste) and HCB (24-1300 ng kg−1 waste) spanned a wide but similar range. Within the datasets there is no indication of significant waste composition effect on emission factor with the exception of significantly higher Mexico rural samples.  相似文献   

6.
Polychlorinated dibenzo-p-dioxin and dibenzofuran (PCDD/PCDF) were overall measured and compared in ambient air, water, soils, and sediments along the upper reaches of the Haihe River of North China, so as to evaluate their concentrations, profiles, and to understand the processes of gas–particle partitioning and air–water/soil exchange. The following results were obtained: (1) The average concentrations (toxic equivalents, TEQs) of 2,3,7,8-PCDD/PCDF in air, water, sediment, and soil samples were 4,855 fg/m3, 9.5 pg/L, 99.2 pg/g dry weight (dw), and 56.4 pg/g (203 fg TEQ/m3, 0.46 pg TEQ/L, 2.2 pg TEQ/g dw, and 1.3 pg TEQ/g, respectively), respectively. (2) Although OCDF, 1,2,3,4,6,7,8-HpCDF, OCDD, and 1,2,3,4,6,7,8-HpCDD were the dominant congeners among four environmental sinks, obvious discrepancies of these congener and homologue patterns of PCDD/PCDF were observed still. (3) Significant linear correlations for PCDD/PCDF were observed between the gas–particle partition coefficient (K p) and the subcooled liquid vapor pressure (P L 0) and octanol–air partition coefficient (K oa). (4) Fugacity fraction values of air–water exchange indicated that most of PCDD/PCDF homologues were dominated by net volatilization from water into air. The low-chlorinated PCDD/PCDF (tetra- to hexa-) presented a strong net volatilization from the soil into air, while high-chlorinated PCDD/PCDF (hepta- to octa-) were mainly close to equilibrium for air–soil exchange.  相似文献   

7.
Fang M  Choi SD  Baek SY  Park H  Chang YS 《Chemosphere》2011,84(7):894-899
An IRA-743 resin bulk sampler was validated to monitor long-term bulk deposition of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). Six consecutive sampling campaigns (2008-2009) were conducted at four sites around steel complexes in Pohang, South Korea to investigate spatial and seasonal variations of PCDD/F bulk deposition. The bulk deposition within the steel complex showed the highest ∑4-8PCDD/F (Tetra-Octa) fluxes, ranging from 204 to 608 (mean: 352) pg m−2 d−1, indicating steel complexes were major sources of PCDD/Fs. The homologue profiles were dominated with lower chlorinated PCDFs. Furthermore, the prevailing winds were confirmed to influence the spatial distribution of PCDD/F deposition. There were apparent seasonal variations of the bulk deposition at each site, and seasonal homologue patterns of PCDD/Fs were clearly observed. According to the passive air sampling, however, no significant seasonal change of ambient air concentrations of PCDD/Fs was observed. Therefore, it was concluded that the seasonal variations of deposition fluxes of PCDD/Fs probably resulted from temperature-dependent gas/particle partitioning.  相似文献   

8.
Li X  Li Y  Zhang Q  Wang P  Yang H  Jiang G  Wei F 《Chemosphere》2011,84(7):957-963
The concern about emissions of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) polychlorinated biphenyls (PCBs), and polybrominated diphenyl ethers (PBDEs) from steel industrial parks has increased in the past decades. In this study, polyurethane foam (PUF)-disk based passive air samples were collected in and around a big steel industrial park of Anshan, Northeast China from June 2008 to March 2009. The levels, seasonal variations and potential sources of PCDD/Fs, PCBs and PBDEs in the atmosphere around the steel industrial complex were investigated, and potential contribution of these three groups of persistent organic pollutants (POPs) from iron and steel production was also assessed. The air concentrations of ∑17PCDD/Fs (summer: 0.02-2.77 pg m−3; winter: 0.20-9.79 pg m−3), ∑19PCBs (summer: 23.5-155.8 pg m−3; winter: 14.6-81.3 pg m−3) and ∑13PBDEs (summer: 2.91-10.7 pg m−3; winter: 1.10-3.89 pg m−3) in this targeted industrial park were relatively low in comparison to other studies, which implied that the industrial activities of iron and steel had not resulted in serious contamination to the ambient air in this area. On the whole, the air concentrations of PCDD/Fs in winter were higher than those of summer, whereas the concentrations of PCBs and PBDEs showed opposite trends. The result from principal component analysis indicated that coal combustion might be the main contributor of PCDD/F sources in this area.  相似文献   

9.
Levels of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) were determined in fourteen ambient air samples collected in twelve cities of five provinces and one large municipality in China. The PCDD/F concentrations varied from 2.6 to 120 pg m−3 (or from 0.04 to 1.93 pg I-TEQ m−3). Generally, TCDF was the dominant homologue group and as a rule the homologue concentration of PCDF decreased with rising chlorine substitution number of PCDF. In all cases 2,3,4,7,8-PeCDF was the most important contributor to the I-TEQ value, accounting for 35–57% of the total I-TEQ value. Higher PCDD/F levels in ambient air were found during winter. The highest PCDD/F levels were found in Chengdu, Sichuan Province. In general, the PCDD/F levels in this study were in the same range as in other studies in China.  相似文献   

10.
PCDD and PCDF were measured in air samples collected in Ohio in 1987. No 2,3,7,8-TCDD was detected in any of the samples with a detection limits of less than 240 fg/m3. Using a chemical mass balance model applied to PCDD/PCDF congener group profiles, major potential sources of these compounds to the atmosphere in Ohio were determined to be municipal solid waste combustion, and sewage sludge combustion. Cancer risk calculations for inhalation of PCDD/PCDF in ambient air in Ohio are approximately 10–6. Given the current knowledge of the health effects of exposure to PCDD/PCDF in air, there is no appreciable risk to public health for the levels of these compounds found in ambient air in Ohio.  相似文献   

11.
At a MSWI (municipal solid waste incinerator) plant PCDD/PCDF samples (gasphase and particulates) were taken simultaneously be a shock-freezing method in the incinerator combustion chamber at approx. 800°C and in four sampling sections in the boiler at about 490°C, 370°C, 330°C and 270°C. In this way PCDD/PCDF-formation in the flow through the boiler was determined. Two data sets were evaluated. A considerable PCDD/PCDF-formation had occurred already at boiler temperatures of about 490°C; the highest concentration, however, was found at the end of the boiler at about 300°C. The accompanying measuring program of plant parameters made the calculation of the PCDD/PCDF mass flows possible, which allowed the inclusion of the PCDD/PCDF-content in the ESP dust in the mass flow calculations.  相似文献   

12.
Shin SK  Jin GZ  Kim WI  Kim BH  Hwang SM  Hong JP  Park JS 《Chemosphere》2011,83(10):1339-1344
Polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) and dioxin-like polychlorinated biphenyls (DL-PCBs) were measured in ambient air samples collected from different parts of South Korea in 2008, and the measured levels were used for assessing the spatial and temporal distribution of atmospheric PCDDFs and DL-PCBs in South Korea. The average concentrations of atmospheric PCDD/Fs and DL-PCBs among the 37 sites were 28 fg I-TEQ m−3 (ND ∼ 617) and 1 fg WHO-TEQ m−3 (ND ∼ 0.016). Elevated atmospheric levels of PCDD/Fs and DL-PCBs observed at residential/industrial sites and in the north-west of Korea, indicated a potential contribution and impacts of anthropogenic sources of PCDD/Fs and DL-PCBs. These levels were similar or lower than those previously reported in other ambient air surveys. Average concentrations of PCDD/Fs showed small seasonal variations (ANOVA analysis, p = 0.144). The highest concentrations of PCDD/Fs were observed during winter, followed by spring, autumn and summer. Atmospheric PCDD/Fs and DL-PCBs in South Korea rapidly decreased during the last 10 years (1998-2008), demonstrating the efficiency of stricter regulations and the application of best available technologies/best environmental practices at emission sources. Comparison of the congener profiles and principal component analysis showed that current atmospheric PCDD/Fs are mostly influenced by industrial sources and PCBs from old commercial PCB uses. Nationwide POPs monitoring will continue and allows an effective evaluation of the implementation of the Stockholm Convention on POPs.  相似文献   

13.
Volatile organic compounds (VOCs) from several different municipal solid wastes’ treatment plants in Mallorca (Spain) have been analysed by thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS). Ambient (immission) air was collected during February and March 2011 by active sampling onto sorbents Tenax™ TA and Carboxen™ 1000. The study presents the chemical characterisation of 93 volatile organic compounds (VOCs) from an overall set of 84 immission air samples. 70 VOCs were positively identified.The linear fit for all 93 external standard calibration, from 10 mg L−1 to 150 mg L−1 (n = 4), was within the range 0.974 < r2 < 0.998. Limits of detection of the method (LOD) for all the standards were within the range 1.1-4,213 pg, as the absolute standard amount spiked into sorbent tubes in 1 μL standard mixture (dissolved in methanol).Overall results stated systematic correlation between waste’s nature and VOCs’ air composition. Organic wastes show main contribution of terpenes, waste water sludge residues’ of reduced sulphured compounds (RSCs) and municipal solid wastes show contribution of a wide sort of VOCs. The use of a chemometric approach for variable’s reduction to 12 principal components enables evaluation of similarities and dissimilarities between facilities. PCA clearly related samples to its corresponding facility on the basis of their VOCs composition and the ambient temperature.  相似文献   

14.
In a laboratory-scale combustion reactor, flue-gas samples were collected at two temperatures in the post-combustion zone, 700 °C and 400 °C, using two different water-cooled sampling probes. The probes were the cooled probe described in the European Standard method EN-1948:1, referred to as the original probe, and a modified probe that contained a salt/ice mixture to assist the cooling, referred to as the sub-zero probe. To determine the efficiency of the cooling probes, internal temperature measurements were recorded at 5 cm intervals inside the probes. Flue-gas samples were analyzed for polychlorinated dibenzo-p-dioxin and dibenzofurans (PCDD/Fs). Samples collected at 700 °C using the original cooling probe showed higher concentrations of PCDD/Fs compared to samples collected using the sub-zero probe. No significant differences were observed between samples collected at 400 °C. The results indicated that artifact formation of PCDD/Fs readily occurs during flue-gas sampling at high temperatures if the cooling within the probe is insufficient, as found for the original probe at 700 °C. It was also shown that this problem could be alleviated by using probes with an enhanced cooling capacity, such as the sub-zero probe.Although this may not affect samples collected for regulatory purposes in exit gases, it is of great importance for research conducted in the high-temperature region of the post-combustion zone.  相似文献   

15.
Open burning of crop residues has been identified as an important emission source of PCDD/PCDF to the environment. This paper presents the first known data on the emission of PCDD/PCDF to the land considering the influence of pesticides applied in crops planting. Emission factor for PCDD/PCDF to the land from open burning of corn straw with pesticides contamination ranged from 0.07 to 0.57 ng WHO2005-TEQ/kg straw burned with a mean value of 0.24 ng WHO2005-TEQ/kg straw burned and median value of 0.20 ng WHO2005-TEQ/kg straw burned, respectively. The concentration was 35 to 270 times higher than that without additional pesticide contaminated. Initial observation was that emission factor for PCDD/PCDF from open burning of crop residues was overestimated in the former UNEP Dioxin Toolkit. Pesticides contamination should be considered in some hotpots where special and over dosed pesticides has been sprayed especially in developing countries.  相似文献   

16.
Since the CALUX (Chemically Activated LUciferase gene eXpression) bioassay is a fast, sensitive and inexpensive tool for the analysis of a high number of samples, validation of new methods is urgently needed. In this study, a new method for the analysis of PCDD/Fs and dioxin-like PCBs in atmospheric deposition samples with the CALUX bioassay was developed, optimized and validated. The method consists of 4 steps: filtration, extraction, clean up and bioassay analysis. To avoid the use of large amounts of toxic solvents, new techniques were used for filtration and extraction: a C18 filter was used instead of a liquid/liquid extraction and an Accelerated Solvent Extractor (ASE) was used instead of the traditional soxhlet extraction. After pre-oxidation of the sample extract, clean up was done using a multi-layer silica gel column coupled to a carbon column. The PCDD/F and PCB fractions were finally analyzed with the H1L7.5c1 and/or the H1L6.1c3 mouse hepatoma cell lines. The limit of quantification was 1.4 pg CALUX-BEQ m−2 d−1 for the PCBs and 5.6 pg CALUX-BEQ m−2 d−1 for the PCDD/Fs, when using the new sensitive H1L7.5c1 cell line. The GC-HRMS recovery for all PCDD/F congeners was between 55% and 112%, with a mean recovery of 90%. CALUX recoveries of spiked procedural blanks were between the accepted ranges of 80-120%. Repeatability and reproducibility were satisfactory and no interferences from metals were detected. The first results from the Flemish measurement program showed good correlation between CALUX and GC-HRMS.  相似文献   

17.
In this study, ambient air samples from different atmospheric environments were examined for both PBDE and PCDD/F characteristics to verify that combustion is a significant PBDE emission source. The mean ± SD atmospheric PBDE concentrations were 165 ± 65.0 pg Nm−3 in the heavy steel complex area and 93.9 ± 24.5 pg Nm−3 in the metals complex areas, 4.7 and 2.7 times higher than that (35.3 ± 15.5 pg Nm−3) in the urban areas, respectively. The statistically high correlation (r = 0.871, p < 0.001) found between the atmospheric PBDE and PCDD/F concentrations reveals that the combustion sources are the most likely PBDE emission sources. Correspondence analysis shows the atmospheric PBDEs of the heavy steel and metals complex areas are associated with BDE-209, -203, -207, -208, indicative of combustion source contributions. Furthermore, the PBDEs in urban ambient air experience the influence of the evaporative releases of the commercial penta- and octa-BDE mixtures, as well as combustion source emissions. By comparing the PBDE homologues of indoor air, urban ambient air, and stack flue gases of combustion sources, we found that the lighter brominated PBDEs in urban ambient air were contributed by the indoor air, while their highly brominated ones were from the combustion sources, such as vehicles. The developed source identification measure can be used to clarify possible PBDE sources not only for Taiwanese atmosphere but also for other environmental media in other countries associated with various emission sources in the future.  相似文献   

18.
Open burning for waste disposal is, in many countries, the dominant source of polychlorinated dibenzodioxins, dibenzofurans and biphenyls (PCDD/PCDF/PCB) release to the environment. To generate emission factors for open burning, experimental pile burns of about 100 kg of household waste were conducted with emissions sampling. From these experiments and others conducted by the same authors it is found that less compaction of waste or active mixing during the fire - “stirring” - promotes better combustion (as evidenced by lower CO/CO2 ratio) and reduces emissions of PCDD/PCDF/PCB; an intuitive but previously undemonstrated result. These experiments also support previous results suggesting PCDD/PCDF/PCB generation in open burning - while still highly variable - tends to be greater in the later (smoldering) phases of burning when the CO/CO2 ratio increases.  相似文献   

19.
The yield of PCDD/F in relation to the presence of oxygenated PAH in model waste incinerator flyash has been investigated in a fixed bed laboratory scale reactor. Experiments were undertaken by thermal treatment of the model flyash at 250 and 350 °C under a simulated flue gas stream for 2 h. After reaction, the PCDD/F content of the reacted flyash and the PCDD/F released into the exhaust gas, and subsequently trapped by XAD-II resin in a down-stream condensation system were analyzed. The PAHs investigated were, dibenzofuran and benzo[b]naphtho[2,3-d]furan and were spiked onto the model flyash as reactant precursors for PCDD/F formation. The results showed significant formation of furans from both of the PAH investigated, however except from some highly chlorinated dioxin congeners, the formation of dioxins was not so common. Benzonaphthofuran was significantly more reactive than dibenzofuran in PCDD/F formation, in spite of the fact that dibenzofuran is structurally more similar to that of PCDD/F. Thus, there was no clear attribution between the chemical structure of PAH used and the formation of PCDD/F. There were considerable differences between the yields of PCDD/F congeners in the gaseous species and those in the reacted flyash under the same operational conditions. The concentration of PCDD/Fs was reduced at the higher reaction temperature of 350 °C; however, the higher temperature resulted in the majority of the PCDD/F formed on the flyash being released into the gas phase.  相似文献   

20.
The 2008 dioxin incident in Ireland resulted in elevated concentrations of polychlorinated dibenzo-p-dioxins (PCDDs), dibenzofurans (PCDFs) and polychlorinated biphenyls (PCBs) in Irish pork and pork products, due to the consumption of contaminated animal feed by pigs. In order to investigate any resulting impact on the Irish population, these contaminants were measured in pooled breast milk samples from 109 first-time mothers, collected in 2010. A comparison of the results with similar data from 2002 revealed generally lower concentrations of PCDD/Fs and dioxin-like PCBs in the 2010 samples, confirming the declining trend reported by many authors. Contaminant concentration levels for both 2002 and 2010 were generally slightly lower than those reported internationally, with a mean combined PCDD/F and PCB WHO-TEQ of 9.66 pg g−1 fat, for an overall pooled sample of milk from 2010. An apparent slight increase in PCDFs was observed between 2002 and 2010 (from 2.73 pg WHO-TEQ g−1 fat to 3.21 pg WHO-TEQ g−1 fat), with the main contributory congener being 2,3,4,7,8-PentaCDF. While it cannot be totally discounted that the slight increase in 2,3,4,7,8-PentaCDF and in the overall PCDF WHO-TEQ in breast milk could be attributable to consumption of Irish pork during the 2008 incident, we consider that it is more likely that this was due to other factors, including the predominantly urban/industrial sampling locations for the 2010 samples, compared to 2002.  相似文献   