首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 343 毫秒
1.
BACKGROUND: Dye wastewater is one of the main pollution sources of water bodies in China. Conventional biological processes are relatively ineffective for color removal, the development of alternative treatment methods will become important. Our subjective was that of introducing a new biotreatment technology which combined a facultative biofilm reactor (FBR) with an aerobic reactor (AR) to treat a dye wastewater. The efficiencies of color and chemical oxygen demand (COD) removal and the mechanism of dye degradation were investigated. METHODS: The anthraquinone acid dye (acid blue BRLL) concentration, organic loading rate (OLR) and hydraulic retention time (HRT) were varied in the experiments to evaluate the treatment efficiency and process stability. The biodegradation products were detected by infrared (IR) and high performance liquid chromatography and mass spectrometry (HPLC-MS). RESULTS AND DISCUSSION: The results demonstrated that the facultative biofilm process was more effective for decolorization than the anaerobic stage of an anaerobic-aerobic process. Most color removal occurred in the facultative reaction (maximum to 88.5%) and the BOD (biochemical oxygen demand): COD of the FBR effluent increased by 82.2%, thus improving the biodegradability of dyes for further aerobic treatment. The dye concentration, OLR and HRT will be the factors affecting decolorization. Color removal efficiency falls as the influent dye concentration increases, but rises with increased HRT. The infrared and HPLC-MS analyses of the effluents of FBR and AR reveal that the dye parent compound was degraded in each reactor during the process. CONCLUSION: The Facultative-aerobic (F-A) system can effectively remove both color and COD from the dye wastewater. The FBR played an essential role in the process. The average overall color and COD in the system were removed by more than 93.9% and 97.1%, respectively, at an OLR of 1.1 kg COD m(-3) d(-1) and at the HRT of 18-20 hours in the FBR and 4-5 hours in the AR. The color removal mechanism in each reactor was not only a sort of biosorption on the floc materials, but even more an effect of biodegradation, especially in the facultative process. Recommendation and Outlook. In applying the F-A system to treat a dye wastewater, the control of facultative processes and the set up of appropriate operation conditions appear to be critical factors. Also, it is suggested a moderate COD loading rate and about a 24-hour HRT will favor the F-A system.  相似文献   

2.
BACKGROUND, AIMS AND SCOPE: Hexavalent chromium [Cr(VI)] cannot react with either carbonate or hydroxide to form chromium precipitates. However, by using a precipitation technology to treat plating wastewater containing Cr(VI), Cu(II), Ni(II) and Zn(II), approximately 78% of Cr(VI) (initial 60 mg/L) was co-removed with the precipitation of Cu(II), Ni(II) and Zn(II) (each 150 mg/L) by dosing with Na2CO3 (Sun 2003). Direct precipitation by forming Cu(II)-Cr(VI) precipitates followed by adsorption of Cr(VI) onto freshly formed Cu-precipitates was subsequently found to be the main mechanism(s) involved in Cr(VI) co-removal with Cu(II) precipitation by dosing Na2CO3 stepwise to various pH values (Sun et al. 2003). This study was. carried out to further characterize the formation of primary precipitates during the early stages of copper precipitation and simultaneous removal of Cr(VI) with Cu(II). METHODS: Test metal-solutions were prepared with industrial grade chemicals: CuCl2 x 2H2O, Na2SO4 and K2Cr2207. NaCO3 was added drop-wise to synthetic metal-solution to progressively increase pH. For each pH increment, removal of soluble metals was detected by atomic absorption spectrophotometer (AAS) and surface morphology of precipitates was analyzed by scanning electron microscope (SEM). To further characterize the formation of primary precipitates, a series of MINEQL+ thermodynamic calculations/analyses and equilibrium calculations/ analyses were conducted. RESULTS AND DISCUSSION: MINEQL+ thermodynamic calculation indicated that, for a system containing 150 mg/L Cu(II) and 60 mg/L Cr(VI) with gradual Na2CO3 dosing, if any precipitates can be formed at pH 5.0 or lower, it should be in the form of CuCrO4. Comparison tests using systems containing the same equivalent of Cu(II) plus Cr(VI) and Cu(II) plus SO4(2-) showed that the precipitation occurred at a pH of around 5.0 in the Cu(II)-Cr(VI) system and around 6.0 in the Cu(II)-SO4(2-) system. The discrepancy of the precipitation was indeed caused by the formation of Cu-Cr precipitates. The initiation of copper removal at pH around 5.0 for the Cu-Cr co-removal test was not attributable to the formation of Cu-CO3 precipitates, instead, it was most likely through the formation of insoluble Cu-Cr precipitates, such as CuCrO4 and CuCrO4 x 2Cu(OH)2. Experimental tests, equilibrium calculations, MINEQL+ thermodynamic calculations and surface morphologies for systems using higher concentrations of Cu(II) and Cr(VI) further verified the most probable composition of primary precipitates is copper-chromate. CONCLUSION: In the Cu-Cr co-removal test with Na2O3 dosing to increase pH and induce metal precipitation, copper-chromate precipitates are the primary precipitates produced and contribute to the initial simultaneous removal of copper and chromium.  相似文献   

3.
以含铜废水为处理对象,重点考察了诱晶载体的表面性质及表面负荷对诱导结晶过程的影响。结果表明,在工艺启动初期,白云石以及碱式碳酸铜为诱晶载体时,铜的去除率在90%以上,石英砂对铜的去除率较低,但石英砂经表面改性后对铜的去除效率亦可达90%以上。在运行稳定后,几类诱导载体对铜的去除率皆能稳定在95%,说明诱晶载体的表面性质对诱导结晶工艺的影响主要在于反应启动初期,选择与目标结晶产物结构、成分相同或相似的诱晶载体有利于诱导结晶过程的进行。此外,研究结果还表明,诱晶载体表面负荷对结晶过程影响较大,诱导结晶除铜工艺中载体表面负荷不宜高于0.054gCu/(m2·d)。  相似文献   

4.
Kim SK  Kim KH  Ihm SK 《Chemosphere》2007,68(2):287-292
The nature of active copper species is well-known to vary with copper loading, i.e., isolated Cu(2+) to bulk CuO. In this work, however, the effect of copper loading on the activity and the selectivity was investigated for the wet oxidation of phenol over CuO(x)/Al(2)O(3) catalysts. The activity and the mineralization selectivity of the catalysts increased with copper loading up to 7wt% and remained almost the same at a higher loading. The optimum copper loading was about 7wt% for the wet oxidation of phenol over CuO(x)/Al(2)O(3) catalysts in this work. The nature of copper species with different loading was characterized with TPR, XRD, and XANES. The chemical states of copper in the CuO(x)/Al(2)O(3) catalysts were confirmed as varying with copper loading: isolated Cu(2+) ions for 1wt%; highly dispersed Cu(2+) cluster for 5wt% and 7wt%, and bulk CuO for 10-25wt%. The stability of the CuO(x)/Al(2)O(3) catalysts with different copper loading was also studied with respect to carbonaceous deposits and copper leaching.  相似文献   

5.
Bioleaching processes have been demonstrated to be effective technologies in removing heavy metals from wastewater sludge, but long hydraulic retention times are typically required to operate these bioprocesses. A hybrid process (coupling biological and chemical processes) has been explored in laboratory pilot-scale experiments for heavy metals (cadmium [Cd], copper [Cu], chromium [Cr], and zinc [Zn]) removal from three types of sludge (primary sludge, secondary activated sludge, and a mixture of primary and secondary sludge). The hybrid process consisted of producing a concentrate ferric ion solution followed by chemical treatment of sludges. Ferric iron solution was produced biologically via oxidation of ferrous iron by A. ferrooxidans in a continuous-flow stirred tank (5.2 L) reactor (CSTR). Wastewater sludge filtrate (WSF) containing nutrients (phosphorus and nitrogen) has been used as culture media to support the growth and activity of indigenous iron-oxidizing bacteria. Results showed that total organic carbon (TOC) concentrations of the culture media in excess of 235 mg/L were found to be inhibitory to bacterial growth. The oxidation rate increased as ferrous iron concentrations ranged from 10 to 40 g Fe2+/L. The percentage of ferrous iron (Fe2+) oxidized to ferric iron (Fe3+) increased as the hydraulic retention time (HRT) increased from 12 to 48 h. Successful and complete Fe2+ oxidation was recorded at a HRT of 48 h using 10 g Fe2+/L. Subsequently, ferric ion solution produced by A. ferrooxidans in sludge filtrate was used to solubilize heavy metals contained in wastewater sludge. The best solubilization was obtained with a mixture of primary and secondary sludge, demonstrating a removal efficiency of 63, 71, 49, and 80% for Cd, Cu, Cr, and Zn, respectively.  相似文献   

6.
Removal of metal ions and humic acid from water by iron-coated filter media   总被引:8,自引:0,他引:8  
Lai CH  Chen CY 《Chemosphere》2001,44(5):1177-1184
Iron oxide is an excellent, regenerable adsorbent, and often controls free metals through adsorption reaction. The utilization of heating process for coating iron oxide on sand surface allowed the media to be used in a packed column. Iron-coated sand was investigated for adsorbing metal ions and natural organic matter from water by batch and column experiments. Chemical analysis (energy dispersive analysis of X-ray, EDAX) was used for characterizing the copper and lead adsorption sites on iron-coated sand. From the batch experiment results, the copper and lead ions could be removed simultaneously by the iron-coated sand in the competition adsorption system. The interaction between copper, lead ions and iron oxide on sand surface was primarily the chemical bonds. The maximum adsorption capacities of iron-coated sand for copper and lead were 0.259 mg Cu/g-sand and 1.211 mg Pb/g-sand, respectively. The presence of humic acid led to increase the adsorption of copper and lead. Results from column experiments indicated that the copper ions, lead ions and humic acid could be removed completely before the breakpoint. Consequently, the iron-coated sand may be applied for the adsorption/filtration of metal ions and natural organic matters from water.  相似文献   

7.
Lai CH  Lo SL  Chiang HL 《Chemosphere》2000,41(8):1249-1255
This study was conducted to develop a heating process for coating hydrated iron oxide on the sand surface to utilise the adsorbent properties of the coating and the filtration properties of the sand. BET and scanning electron microscope (SEM) analyses were used to investigate the surface properties of the coated layer. An energy dispersive X-ray (EDAX) technique of analysis was used for characterising metal adsorption sites on the iron-coated sand surface. The results indicated that the iron-coated sand had more micropores and higher specific surface area because of the attachment of iron oxide. Copper ions could penetrate into the micropores and mesopores of iron oxide on sand surface, and the regeneration of the iron-coated sand could be achieved by soaking with pH = 3.0 acid solution. Besides, the results of EDAX analysis showed that copper ions were chemisorbed on the surface of iron-coated sand. Results of the study developed an innovative technology for coating iron oxide on sand surface for the treatment of heavy metal in water.  相似文献   

8.
线路板废水中的铜主要以络合态存在,破络除铜是其处理稳定达标的关键环节。为了降低运行费用和产泥量,同时为后期的工程升级改造提供依据和参考,实验研究了碱法破络除铜最佳pH值、Na2S/Cu摩尔比、反应时间和絮凝剂种类的选择等,并从处理效率、投药成本、污泥产量多方面考核,确定最佳运行条件:以NaOH调节pH到10.5左右,Na2S与进水总铜摩尔比为1.5∶1~2∶1,反应30 min,再加100 mg/L的PAC和3 mg/L的PAM混凝反应,沉淀0.5 h,出水铜浓度低于0.3 mg/L,达到《电镀污染物排放标准》(GB 21900-2008)中的总铜排放标准。  相似文献   

9.
Iron oxide-loaded slag for arsenic removal from aqueous system   总被引:5,自引:0,他引:5  
Zhang FS  Itoh H 《Chemosphere》2005,60(3):319-325
An effective adsorbent for arsenic removal from aqueous system was synthesized by loading iron(III) oxide on municipal solid waste incinerator melted slag. The loading was accomplished via chemical processes and thermal coating technique. The key point of the technique was the simultaneous generation of amorphous FeOOH sol and silica sol in-situ and eventually led to the formation of Fe-Si surface complexes which combined the iron oxide with the melted slag tightly. The surface morphology of the iron oxide-loaded slag was examined and the loading mechanisms were discussed in detail. The adsorbent was effective for both arsenate and arsenite removal and its removal capabilities for As(V) and As(III) were 2.5 and 3 times of those of FeOOH, respectively. Both affinity adsorption and chemical reactions contributed to arsenic removal. The effects of solution pH, contact time, arsenic concentration and adsorbent dosage on arsenic removal were examined and the optimum removal conditions were established. Furthermore, leaching of hazardous elements such as Cr(VI), As, Se, Cd and Pb from the adsorbent at a pH range of 2.5-12.5 was below the regulation values. Accordingly, it is believed that the iron oxide-loaded slag developed in this study is environmentally acceptable and industrially applicable for wastewater treatment.  相似文献   

10.
In this study, several factors important for the design of a water supply treatment system for the removal of trace amounts of organic contaminants by microorganisms in a fixed-film were assessed. This entailed evaluating the effect of seeding with adapted microorganisms on the acclimation time, determining what depth of support material was required for removal of contaminants and observing the effect of hydraulic loading rate on the contaminant removal efficiency by the microorganisms. The study was conducted in the laboratory using sand columns as fixed-film biological reactors. Pentachlorophenol (PCP), 2,4,6 trichlorophenol and 2,4 dichlorophenol were used as the test contaminants. Dechlorinated Philadelphia tap water, which contained concentrations of dissolved organic matter (DOC) in the range of 1 to 4 mg/l, was used as the source water. The DOC of the source water served as a primary substrate for microbial growth in the sand columns. The total concentration of the contaminants added to the source water ranged between 200 and 800 μg/l, making them available as secondary carbon sources for the attached microorganisms. The columns were operated in a downflow mode and the hydraulic loading rates through the columns were varied from 0.5 gpm/ft² to 3 gpm/ft² (1.2 m/hr to 7.3 m/hr). It was observed that each cycle of operation of the treatment system could be divided into three different stages: acclimation; equilibrium removal; and clogging. Acclimation is the period of time between initial startup and equilibrium removal of the contaminants. Equilibrium removal was defined as the consistent removal of the contaminants for at least four days. Clogging of the sand with biological growth was found to occur after long term operation in shallow depths of sand. The acclimation time and the establishment of an adapted population were not shortened by seeding the sand columns with laboratory acclimated cultures. During the second stage, equilibrium removal, the removal of DOC decreased with depth as a first order relationship. However, the removal of the contaminants was observed to be zero order. Removal of the contaminants decreased with increasing hydraulic loading rate. Reductions of 80% or more of μg/l amounts of the chlorophenolic contaminants was achieved in a one inch depth of sand.  相似文献   

11.
以含铜废水为处理对象,重点考察了诱晶载体的表面性质及表面负荷对诱导结晶过程的影响。结果表明,在工艺启动初期,白云石以及碱式碳酸铜为诱晶载体时,铜的去除率在90%以上,石英砂对铜的去除率较低,但石英砂经表面改性后对铜的去除效率亦可达90%以上。在运行稳定后,几类诱导载体对铜的去除率皆能稳定在95%,说明诱晶载体的表面性质对诱导结晶工艺的影响主要在于反应启动初期,选择与目标结晶产物结构、成分相同或相似的诱晶载体有利于诱导结晶过程的进行。此外,研究结果还表明,诱晶载体表面负荷对结晶过程影响较大,诱导结晶除铜工艺中载体表面负荷不宜高于0.054 g Cu/(m2.d)。  相似文献   

12.
Zhou W  Imai T  Ukita M  Li F  Yuasa A 《Chemosphere》2007,66(5):924-929
Serious inhibition was found in the regular up-flow anaerobic sludge blanket (UASB) reactor in treating the evaporator condensate from a sulfite pulp mill, which contained high strength sulfur compounds. After applying the direct limited aeration in the UASB, the inhibition was alleviated gradually and the activity of the microorganisms was recovered. The COD removal rate increased from 40% to 80% at the organic loading rate of 8kgCODm(-3)d(-1) and a hydraulic retention time of 12h. Limited aeration caused no oxygen inhibition to the anaerobic microorganisms but instigated sulfide oxidization and H(2)S removal, which was beneficial to the methanogens. The experiment confirmed the feasibility of applying limited aeration in the anaerobic reactor to alleviate the sulfide inhibition. It also proved that the anaerobic system was actually aerotolerant. SEM observation showed that the predominant microorganisms partly changed from rod-shaped methanogens to cocci after the UASB reactor was aerated.  相似文献   

13.
采用厌氧流化床(AFB)-序批式反应器(SBR)工艺处理蓝皮制革工业废水。分别考察了水力停留时间(HRT)、容积负荷对厌氧流化床以及曝气时间、污泥浓度、溶解氧浓度对SBR反应器处理效果的影响。试验结果表明,AFB将实验废水的BOD_5/COD(B/C)值由0.19~0.26提高至0.35~0.42,有效提高了其可生化性;在进水COD浓度为1 700~1 890 mg/L、HRT为1 d、容积负荷为1.792 kg COD/(m~3·d)时,COD去除率达65.2%~68.5%,且具有良好的抗冲击负荷能力。SBR在进水COD浓度为628~712 mg/L、污泥浓度为2.9 g/L、曝气时间为10 h、溶解氧浓度为2 mg/L工况下,COD去除率达87.6%,NH_3-N去除率达93.6%,处理后出水水质符合污水综合排放标准(GB 8978-1996)中的一级标准要求。  相似文献   

14.
Anaerobically digested sewage sludges were treated for heavy metal removal through a biological solubilization process called bacterial leaching (bioleaching). The solubilization of copper and zinc from these sludges is described in this study: using continuously stirred tank reactors with and without sludge recycling at different mean hydraulic residence times (1, 2, 3 and 4 days). Significant linear equations were established for the solubilization of zinc and copper according to relevant parameters: oxygen reduction potential (ORP), pH and residence time (t). Zinc solubilization was related to the residence time with a r2 (explained variance) of 0.82. Considering only t=2 and 3 days explained variance of 0.31 and 0.24 were found between zinc solubilization as a function of ORP and pH indicating a minor importance of those two factors for this metal in the range of pH and ORP experimented. Cu solubilization was weakly correlated to mean hydraulic residence time (r2=0.48), while it was highly correlated to ORP (r2=0.80) and pH (r2=0.62) considering only t of 2 and 3 days in the case of pH and ORP. The ORP dependence of Cu solubilization has been clearly demonstrated in this study. In addition to this, the importance of the substrate concentration for Cu solubilization has been confirmed. The hypothesis of a biological solubilization of Cu by the indirect mechanism has been supported. The results permit, under optimum conditions, the drawing of linear equations which will allow prediction of metal solubilization efficiencies from the parameters pH (Cu), ORP (Cu) and residence time (Cu and Zn), during the treatment. The linear regressions will be a useful tool for routine operation of the process.  相似文献   

15.
Struvite precipitation has increasing interest as a technology for removing and recovering phosphorus from wastewater streams. Many chemical factors have been studied, such as optimum pH values and component-ion molar ratios, yet, understanding of physical aspects is lacking. Two physical parameters were tested: (1) seeding material addition and (2) mixing. Objectives were to evaluate three seeding materials and to optimize mixing conditions for struvite-crystal precipitation, growth, and subsequent sedimentation. Results confirm that mixing strength and proper seeding materials increase crystal size and improve settleability. For unseeded solutions, optimum phosphorus removal was achieved at a mixing strength of G = 76 s(-1). Struvite crystals that were added as the seeding material provided the best performance with respect to phosphorus removal and crystal-size distribution. Overall, this study provided information to improve the practical application of struvite precipitation as a phosphorous-treatment technology for wastewaters, while generating a marketable slow-release fertilizer as a product.  相似文献   

16.
Copper partitioning was studied in seven calcareous soils at moisture content corresponding to 1.2 times the field moisture content (soil water potential 7.84 J kg(-1)). Copper retention was accompanied by the release in soil solution of Ca(2+), Mg(2+), Na(+), and H(+), and the total amount of these cations released was 0.8 to 1.09 times the amount of Cu sorbed (mol(c):mol(c)). The relationships between Cu activity and pH, and the balance of cations in soils correspond with the surface precipitation of CuCO(3) as the main mechanism of Cu retention. The values of ion activity product of surface precipitate were close for all studied soils with the average log(IAP(CuCO(3)))=-15.51. The relationship between copper activity in soil solutions and soil properties is well fit by a regression relating pCu (-log copper ion activity) with soil pH, total Cu, and carbonate content.  相似文献   

17.
Lin CJ  Chang JE 《Chemosphere》2001,44(5):1185-1192
Fly ash is a particulate substance containing metal oxides, carbon and other microelements. In this study, fly ashes with different quantities of carbon and minerals prepared by a thermal process in the laboratory were used as adsorbents to investigate the contribution of precipitation and adsorption to the removal of aqueous Cu(II). Experimental results showed that the specific surface area of fly ash increased linearly with the quantity of carbon. The specific surface areas of the carbon and mineral fraction were 60 m2/g and 0.68 m2/g, respectively. The specific adsorption capacities of carbon ranged from 2.2 to 2.8 mg Cu/g carbon, while those for mineral were only about 0.63 to approximately 0.81 mg Cu/g mineral. Consequently, the carbon fraction in fly ash was important in the removal of Cu(II) at pH 5. However, Cu(II) removal owing to precipitation increases with a decreasing carbon fraction and the contribution of copper precipitation was estimated to be approximately 23% to approximately 82% of total removal, depending on the carbon fraction of fly ash.  相似文献   

18.
Wen Q  Chen Z  Shi H 《Chemosphere》2008,71(9):1683-1692
Steady simultaneous nitrification-denitrification (SND) was achieved in a fluidized bed reactor (FBR) by the control of DO concentration without physical separation of the aerobic and anoxic zones. The performance and composition of nitrifying bacteria were examined in this study. The ammonium removal efficiency was higher than 80% and the DO concentration (1-5 mg l(-1)) had little influence on it. More than 50% total nitrogen (TN) removal efficiency was achieved when DO was less than 3 mg l(-1) and in many cases the removal efficiency varied between 60-70%. The volumetric loading of TN varied between 0.12 and 0.20 kg Nm(-3)d(-1). 16S rRNA-based terminal restriction fragment length polymorphism analysis was used to characterize the diversity and distribution of the ammonia oxidizing bacteria (AOB) and nitrite-oxidizing bacteria (NOB) in the FBR. The results indicated that, the composition and number of both AOB and NOB changed with position in the reactor and operating time. Nitrosomonas sp. was found to be dominant species of the AOB community, and Nitrobacter sp. also existed in the system. The SND mechanism in the FBR was proved to be the vertical stratification of active populations; however, the presence of microenvironments within the biofilm cannot be ruled out.  相似文献   

19.
Xie L  Shang C 《Chemosphere》2006,64(6):919-930
Bromate reduction by Fe(0) with incorporation of copper or palladium was investigated in batch tests. The incorporation of copper led to an increase in the rate of bromate reduction, while incorporation of palladium did not show any effect on bromate reduction by Fe(0), regardless of the bimetal application techniques (either simultaneous addition of Cu(II) or Pd(IV) into the Fe-BrO3- reaction system or using copper or palladium amended iron for bromate removal). Surface analyses by X-ray photoelectron spectroscopy (XPS) and X-ray powder diffraction (XRD) techniques indicated that aqueous Cu(II) was reduced and incorporated into the iron surface to form Cu2O and Cu(0). Among these two species, pure Cu(0) is not an active electron donor to the bromate reduction reaction, as shown by there being no reduction from using Cu(0) powders alone and no enhancement by Fe(0) when physically mixed with Cu(0). Although it has been proposed in the literature that the enhancement of adsorption also contributes to the enhancement of chemical reduction, this is not the case here because adsorption decreased when Cu increased. The enhanced bromate reduction rate in the presence of copper observed here is most likely the result of the newly formed active Cu(I). The presence of PdO was evidenced by XPS but yielded no enhancement in bromate reduction. Finally, the Cu2O present on the iron surface because of copper impurities in commercially available iron was found to be involved in the bromate reduction and to accelerate the reduction rate.  相似文献   

20.
Natural pumice particles were used as granular support media and coated with iron oxides to investigate their adsorptive natural organic matter (NOM) removal from waters. The impacts of natural pumice source, particle size fraction, pumice dose, pumice surface chemistry and specific surface area, and NOM source on the ultimate extent and rate of NOM removal were studied. All adsorption isotherm experiments were conducted employing the variable-dose completely mixed batch reactor bottle-point method. Iron oxide coating overwhelmed the surface electrical properties of the underlying pumice particles. Surface areas as high as 20.6m(2)g(-1) were achieved after iron coating of pumice samples, which are above than those of iron coated sand samples reported in the literature. For all particle size fractions, iron coating of natural pumices significantly increased their NOM uptakes both on an adsorbent mass- and surface area-basis. The smallest size fractions (<63 microm) of coated pumices generally exhibited the highest NOM uptakes. A strong linear correlation between the iron contents of coated pumices and their Freundlich affinity parameters (K(F)) indicated that the enhanced NOM uptake is due to iron oxides bound on pumice surfaces. Iron oxide coated pumice surfaces preferentially removed high UV-absorbing fractions of NOM, with UV absorbance reductions up to 90%. Control experiments indicated that iron oxide species bound on pumice surfaces are stable, and potential iron release to the solution is not a concern at pH values of typical natural waters. Based on high NOM adsorption capacities, iron oxide coated pumice may be a promising novel adsorbent in removing NOM from waters. Furthermore, due to preferential removal of high UV-absorbing NOM fractions, iron oxide coated pumice may also be effective in controlling the formation of disinfection by-products in drinking water treatment.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏