共查询到12条相似文献,搜索用时 0 毫秒
1.
Lukas Hörtnagl Robert Clement Martin Graus Albin Hammerle Armin Hansel Georg Wohlfahrt 《Atmospheric environment (Oxford, England : 1994)》2010,44(16):2024-2032
Using proton transfer reaction mass spectrometry equipped with a quadrupol mass analyser to quantify the biosphere-atmosphere exchange of volatile organic compounds (VOC), concentrations of different VOC are measured sequentially. Depending on how many VOC species are targeted and their respective integration times, each VOC is measured at repeat rates on the order of a few seconds. This represents an order of magnitude longer sample interval compared to the standard eddy covariance (EC) method (5–20 Hz sampling rates). Here we simulate the effect of disjunct sampling on EC flux estimates by decreasing the time resolution of CO2 and H2O concentrations measured at 20 Hz above a temperate mountain grassland in the Austrian Alps. Fluxes for one month are calculated with the standard EC method and compared to fluxes calculated based on the disjunct data (1, 3 and 5 s sampling rates) using the following approaches: i) imputation of missing concentrations based on the nearest neighbouring samples (iDECnn), ii) imputation by linear interpolation (iDECli), and iii) virtual disjunct EC (vDEC), i.e. flux calculation based solely on the disjunct concentrations. It is shown that the two imputation methods result in additional low-pass filtering, longer lag times (as determined with the maximum cross-correlation method) and a flux loss of 3–30% as compared to the standard EC method. A novel procedure, based on a transfer function approach, which specifically corrects for the effect of data treatment, was developed, resulting in improved correspondence (to within 2%). The vDEC method yields fluxes which approximate the true (20 Hz) fluxes to within 3–7% and it is this approach we recommend because it involves no additional empirical corrections. The only drawback of the vDEC method is the noisy nature of the cross-correlations, which poses problems with lag determination – practical approaches to overcome this limitation are discussed. 相似文献
2.
A.J. Nunn U. Metzger R. Matyssek 《Environmental pollution (Barking, Essex : 1987)》2010,158(6):2014-2022
Stomatal O3 fluxes to a mixed beech/spruce stand (Fagus sylvatica/Picea abies) in Central Europe were determined using two different approaches. The sap flow technique yielded the tree-level transpiration, whereas the eddy covariance method provided the stand-level evapotranspiration. Both data were then converted into stomatal ozone fluxes, exemplifying this novel concept for July 2007. Sap flow-based stomatal O3 flux was 33% of the total O3 flux, whereas derivation from evapotranspiration rates in combination with the Penman-Monteith algorithm amounted to 47%. In addition to this proportional difference, the sap flow-based assessment yielded lower levels of stomatal O3 flux and reflected stomatal regulation rather than O3 exposure, paralleling the daily courses of canopy conductance for water vapor and eddy covariance-based total stand-level O3 flux. The demonstrated combination of sap flow and eddy covariance approaches supports the development of O3 risk assessment in forests from O3 exposure towards flux-based concepts. 相似文献
3.
城市节假日前后碳通量特征及其与车流量关系 总被引:3,自引:0,他引:3
全球变化背景下,城市作为主要的碳源,对其碳循环的研究成为陆地生态系统碳循环的重点内容之一。以上海市奉贤区为研究对象,基于涡度相关技术,结合定点连续观测的车流量数据,分析节假日(元旦)前后CO2浓度和碳通量的变化特征,及其与车流量的关系。结果表明,CO2浓度和通量日变化呈现明显的双峰型曲线,节假日CO2浓度(385.6mg/L)平均值低于工作日(401.1 mg/L)。在本研究时段内该系统表现为碳源,尽管在白天的某些时段是碳汇,表明城市系统碳通量受自然和人为2个因素共同作用,自然因素比如该系统中的香樟、雪松等常绿植物的光合作用,人为因素由人类活动造成。基于车流量与交通流量的线性回归分析表明,机动车量碳排放对于碳通量变化产生18%的贡献。 相似文献
4.
《Atmospheric environment (Oxford, England : 1994)》2007,41(20):4190-4209
A DeHavilland DHC-6 Twin Otter, operated by the National Oceanic and Atmospheric Administration, was deployed in Tampa, FL to measure aerosols and primary and secondary trace gases in support of the Bay Regional Atmospheric Chemistry Experiment (BRACE). The Twin Otter repeatedly overflew the surface chemistry monitoring super site near Sydney, FL to assess the comparability of surface and airborne datasets and the spatial representativeness of the surface measurements. Prior to comparing the chemical datasets, we evaluated the comparability of the standards used to calibrate surface and airborne detectors, as well as the uniformity of wind fields aloft and at the surface. Under easterly flow, when the dearth of significant upwind emission sources promoted chemical homogeneity at Sydney, trace gas concentrations at the surface and aloft were generally well correlated; R2 ranged from 0.4396 for H2O2 to 0.9738 for O3, and was typically better than 0.70 for NO, NO2, NOY, HNO3, HCHO, and SO2. Mean ratios of aircraft-to-surface concentrations during 10 overflights of Sydney were as follows: 1.002±0.265 (NO), 0.948±0.183 (NO2), 1.010±0.214 (NOY), 0.941±0.263 (HCHO), and 0.952±0.046 (O3). Poorer agreement and larger variability in measured ratios were noted for SO2 (1.764±0.559), HNO3 (1.291±0.391), and H2O2 (1.200±0.657). Under easterly flow, surface measurements at Sydney were representative of conditions over horizontal scales as large as 50 km and agreed well with airborne values throughout the depth of the turbulently mixed boundary layer at mid-day. Westerly flow advected the Tampa urban plume over the site; under these conditions, as well as during transitional periods associated with the development of the land–sea breeze, surface conditions were representative of smaller spatial scales. Finally, we estimate possible errors in future measurement-model comparisons likely to arise from fine scale (or subgrid;<2 km) variability of trace gas concentrations. Large subgrid variations in concentration fields were observed downwind of large emission point sources, and persisted across multiple model grid cells (distances>4 km) in coherent plumes. Variability at the edges of the well-mixed urban plume, and at the interface of the land–sea breeze circulation, was significantly smaller. This suggests that even a failure of modeled wind fields to resolve the sea breeze return can induce moderate, but not overwhelming, errors in simulated concentration fields and dependent chemical processes. 相似文献
5.
Influence of temporally variable groundwater flow conditions on point measurements and contaminant mass flux estimations 总被引:2,自引:0,他引:2
Arno Rein Sebastian Bauer Peter Dietrich Christof Beyer 《Journal of contaminant hydrology》2009,108(3-4):118-133
Monitoring of contaminant concentrations, e.g., for the estimation of mass discharge or contaminant degradation rates, often is based on point measurements at observation wells. In addition to the problem, that point measurements may not be spatially representative, a further complication may arise due to the temporal dynamics of groundwater flow, which may cause a concentration measurement to be not temporally representative. This paper presents results from a numerical modeling study focusing on temporal variations of the groundwater flow direction. “Measurements” are obtained from point information representing observation wells installed along control planes using different well frequencies and configurations. Results of the scenario simulations show that temporally variable flow conditions can lead to significant temporal fluctuations of the concentration and thus are a substantial source of uncertainty for point measurements. Temporal variation of point concentration measurements may be as high as the average concentration determined, especially near the plume fringe, even when assuming a homogeneous distribution of the hydraulic conductivity. If a heterogeneous hydraulic conductivity field is present, the concentration variability due to a fluctuating groundwater flow direction varies significantly within the control plane and between the different realizations. Determination of contaminant mass fluxes is also influenced by the temporal variability of the concentration measurement, especially for large spacings of the observation wells. Passive dosimeter sampling is found to be appropriate for evaluating the stationarity of contaminant plumes as well as for estimating average concentrations over time when the plume has fully developed. Representative sampling has to be performed over several periods of groundwater flow fluctuation. For the determination of mass fluxes at heterogeneous sites, however, local fluxes, which may vary considerably along a control plane, have to be accounted for. Here, dosimeter sampling in combination with time integrated local water flux measurements can improve mass flux estimates under dynamic flow conditions. 相似文献
6.
We present a user-friendly tool for footprint calculations of flux measurements in the surface layer. The calculations are based on the analytical footprint model by Kormann, R. and Meixner, F.X. [2001. An analytical footprint model for Non-neutral Stratification. Boundary-Layer Meteorology 99, 207-224]. The footprint density function of a flux sensor is determined using readily available data from standard eddy covariance measurements. This footprint density function is integrated over defined surface areas given as quadrangular polygons representing e.g. agricultural fields. We illustrate the use and performance of the tool by applying it to CO2 flux measurements with three eddy covariance system at the Swiss CarboEurope grassland site. Two flux towers were positioned in the centre of two neighbouring fields, respectively, that showed a very different CO2 flux during the study period. The third tower was located near the border of the two fields and was frequently influenced by both fields to a similar degree. The calculated footprint fractions were used to simulate the latter flux from the other two systems. The measured and simulated fluxes showed a good agreement and thus support the reliability of the footprint calculation. The presented simple footprint tool can be used as a routine quality check for flux monitoring stations influenced by surface areas with varying vegetation covers and/or land-use. 相似文献
7.
8.
Luciane G. Dos Santos Carolina Lourencetti Alício A. Pinto Wanderlei A. Pignati Eliana F. G. C. Dores 《Journal of environmental science and health. Part. B》2013,48(2):150-162
A method for determining atmospheric concentrations of eight pesticides applied to corn and soybean crops in Mato Grosso state, Brazil is presented. The method involved a XAD-2 resin cartridge coupled to a low volume air pump at 2 L min?1 over 8 hours. Pesticides were recovered from the resin using sonication with n-hexane:ethyl acetate and determined by GC-MS. Good accuracy (76–128%) and precision (CV < 20%) were obtained for atrazine, chlorpyrifos, alpha- and beta-endosulfan, endosulfan sulfate, flutriafol, malathion, metolachlor and permethrin. Method detection ranged from 9.0 to 17.9 ng m?3. This method was applied to 61 gas phase samples collected between December 2008 and June 2009. Atrazine and endosulfan were detected both in urban and rural areas indicating the importance of atmospheric dispersion of pesticides in tropical areas. The simple and efficient extraction method and sampling system employed was considered suitable for identifying pesticides in areas of intense agricultural production. 相似文献
9.
A long-term sampling method for PCDF/D in emissions from combustion facilities is presented. The sampling of PCDF/D was performed over a four week period. The results are compared to results of four one-week measurements. 相似文献
10.
Integration of traditional and innovative characterization techniques for flux-based assessment of Dense Non-aqueous Phase Liquid (DNAPL) sites 总被引:1,自引:0,他引:1
Nandita B. Basu P. Suresh C. Rao Irene C. Poyer Subhas Nandy Megharaj Mallavarapu Ravi Naidu Greg B. Davis Bradley M. Patterson Michael D. Annable Kirk Hatfield 《Journal of contaminant hydrology》2009,105(3-4):161-172
Key attributes of the source zone and the expanding dissolved plume at a trichloroethene (TCE) site in Australia were evaluated using trends in groundwater monitoring data along with data from on-line volatile organic compound (VOC) samplers and passive flux meters (PFMs) deployed in selected wells. These data indicate that: (1) residual TCE source mass in the saturated zone, estimated using two innovative techniques, is small ( 10 kg), which is also reflected in small source mass discharge ( 3 g/day); (2) the plume is disconnecting, based on TCE concentration contours and TCE fluxes in wells along a longitudinal transect; (3) there is minimal biodegradation, based on TCE mass discharge of 6 g/day at a plume control plane 175 m from source, which is also consistent with aerobic geochemical conditions observed in the plume; and (4) residual TCE in the vadose zone provides episodic inputs of TCE mass to the plume during infiltration/recharge events. TCE flux data also suggest that the small residual TCE source mass is present in the low-permeability zones, thus making source treatment difficult. Our analysis, based on a synthesis of the archived data and new data, suggests that source treatment is unwarranted, and that containment of the large TCE plume ( 1.2 km long, 0.3 km wide; 17 m deep; 2000–2500 kg TCE mass) or institutional controls, along with a long-term flux monitoring program, might be necessary. The flux-based site management approach outlined in this paper provides a novel way of looking beyond the complexities of groundwater contamination in heterogeneous domains, to make intelligent and informed site decisions based on strategic measurement of the appropriate metrics. 相似文献
11.
A comparison of mussels (Perna viridis) and semi-permeable membrane devices (SPMDs) was carried out at five sites, representing a gradient of contaminant concentrations, in Hong Kong coastal waters. Mussels, originally collected from a “clean” location, were deployed along with SPMDs at each site for 30 days. Analyses for chlorinated pesticides and polychlorinated biphenyls (PCBs) indicated that SPMDs have potential as monitoring tools, and to some extent can overcome the problems associated with mussels, such as natural variability, differing age, sex, and physical condition. However, in most cases, SPMDs failed to rank the sites in the same order as mussels in terms of contaminant concentrations. Nonetheless, in localities where mussels cannot survive – as shown at Kwun Tong in the present experiment – SPMDs may be valuable in providing an indication of potentially bio-available lipophilic pollutants. 相似文献
12.
Xu T Cho IK Wang D Rubio FM Shelver WL Gasc AM Li J Li QX 《Environmental pollution (Barking, Essex : 1987)》2009,157(2):417-422
A gas chromatograph/electron capture detector-ion trap mass spectrometer (GC/ECD-ITMS) was used for the determination of polybrominated diphenyl ethers (PBDEs) in euryhaline fish and crabs. GC/ECD-ITMS results showed that average recoveries from the spiked fish samples are in a range of 58-123% with relative standard deviations (RSDs) of 5-19%. PBDE concentrations obtained from GC/ECD-ITMS ranged from 28 ng/g to 1845 ng/g lipid weight (lw) in all aquatic species collected from Hawaiian brackish waters. The general BDE congener concentration profile observed in this study is BDE-47 > BDE-100 > BDE-154 > BDE-99 > BDE-153 > BDE-28 > BDE-183. The ELISA results expressed as BDE-47 equivalents correlated well with those of GC/ECD-ITMS, with a correlation coefficient (R2 = 0.68) and regression coefficient (slope = 0.82). Comparison of ELISA with GC/ECD-ITMS results demonstrated that ELISA provides a timely and cost-effective method to screen PBDEs in fish and crab samples. 相似文献