首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 110 毫秒
1.
建立了扩散吸附管采样,热脱附仪和气相色谱联用测定室内空气中BTEX的监测分析方法,方法的最低检出限为0.0002mg/m3。该方法使用方便、便于携带、无需电源,且与传统的泵采样方法具有较好的可比性,适合于室内空气中BTEX的监测。  相似文献   

2.
In the framework of new European directives in the field of ambient air quality assessment specific requirements for measurement methods for benzene will be defined and have to be met in the future. In a residential area in the vicinity of a cokery a comprehensive monitoring programme for BTX compounds (benzene, toluene, xylenes) was carried out with diffusive samplers. Measurement results from 20 sites show a distinct spatial distribution of benzene concentrations which is caused by the emissions of the plant. Comparisons with two pumped measurement methods reveal excellent agreement in the case of benzene. An assessment of measurement uncertainty for the diffusive method is presented in terms of standard deviations from parallel measurements (precision) and by comparison with a reference method according to national and international standards. Data quality objectives required by an upcoming European directive for benzene can be met by diffusive sampling.  相似文献   

3.
This study presents an evaluation of the extent of differences between measurements performed by O(3) and NO(2) diffusive samplers and by the reference methods for diffusive samplers commercially available. The tests were performed in an exposure chamber under extreme conditions of controlling factors and under field conditions. For NO(2), the results of the laboratory experiments showed that most of the diffusive samplers were affected by extreme exposure conditions. The agreement between the samplers and the reference method was better for the field tests than for the laboratory ones. The estimate of the uptake rate for the exposure conditions using a model equation improved the agreement between the diffusive samplers and the reference methods. The agreement between O(3) measured by the diffusive samplers and by the reference method was satisfactory for 1-week exposure. For 8-hour exposures, the diffusive samplers with high uptake rates quantified better the O(3) concentration than the samplers with low uptake rates. As for NO(2), the results of the O(3) field tests were in better agreement with the reference method than the ones of the laboratory tests. The field tests showed that the majority of diffusive samplers fulfils the 25% uncertainty requirement of the NO(2) European Directive and the 30% uncertainty requirement of the O(3) European Directive for 1-week exposure.  相似文献   

4.
Passive air sampling for nitrogen dioxide (NO(2)) and select volatile organic compounds (VOCs) was conducted at 24 fire stations and a compliance monitoring site in Dallas, Texas, USA during summer 2006 and winter 2008. This ambient air monitoring network was established to assess intra-urban gradients of air pollutants to evaluate the impact of traffic and urban emissions on air quality. Ambient air monitoring and GIS data from spatially representative fire station sites were collected to assess spatial variability. Pairwise comparisons were conducted on the ambient data from the selected sites based on city section. These weeklong samples yielded NO(2) and benzene levels that were generally higher during the winter than the summer. With respect to the location within the city, the central section of Dallas was generally higher for NO(2) and benzene than north and south. Land use regression (LUR) results revealed spatial gradients in NO(2) and selected VOCs in the central and some northern areas. The process used to select spatially representative sites for air sampling and the results of analyses of coarse- and fine-scale spatial variability of air pollutants on a seasonal basis provide insights to guide future ambient air exposure studies in assessing intra-urban gradients and traffic impacts.  相似文献   

5.
Results from a five month monitoring campaign of BTX (benzene, toluene and the sum of ethyl benzene, o-xylene, m-xylene and p-xylene), performed at Monterotondo, a little town 23 km NE of Rome, and correlation of the measured concentrations with meteorological and natural radioactivity data are presented and discussed. This campaign allowed us to extrapolate a pattern of the annual distribution of benzene in the town. A map, showing the average distribution of pollutants, is presented, as a useful tool to manage an appropriate policy of air pollution. A contemporary indoor-outdoor investigation has been performed at five homes and two classrooms of Monterotondo and at thirteen homes and thirteen classrooms in the outskirts of Rome. Non-smoking people and low polluted sites were chosen for this campaign, in order to highlight if commonly used domestic materials could act as internal sources. Data, obtained by employing long-term diffusive samplers, are compared with a parallel experiment showing the day-night indoor-outdoor trend. The obtained results, confirmed through statistical analysis of data, let us conclude that there is evidence of internal sources at homes whilst, in the schools, depletion phenomena prevail, probably due to the walls adsorption.  相似文献   

6.
A combined NO2-SO2 Radiello radial-type diffusive sampler was validated under controlled laboratory conditions and compared with NO2-SO2 results of 3 other type of samplers in a field comparison at two locations Ghent-Mariakerke and Borgerhout in Flanders. Laboratory exposures at different temperatures (-5, 10 and 30 degrees C) and relative humidities (0, 50 and 80% RH) in combination with varying concentration levels and exposure times were carried out, with a focus on extreme conditions. Concentration level and exposure time were changed together following suppliers linear working range of samplers and assuring absolute amounts of compounds on the sampler corresponding to those of environmental levels. The average uptake rate for NO2 for 24 hour exposures at 10 degrees C and 50% RH and tested concentration levels (+/-73, 146 and 293 ppb NO2) was 0.076 +/- 0.011 ng ppb(-1) min(-1). Uptake rates during all experiments were lower than the uptake rate given in the instruction manual of the sampler. A significant effect of temperature and relative humidity on NO2 uptake rate was observed. The temperature effect from 10 to 30 degrees C corresponds to the temperature effect given by the supplier of the samplers. High relative humidity (70 to 80%) caused a strong non-reproducible decrease of uptake rate for NO2 at 24 hour experiments but this effect was not observed at longer exposures except for the tests at -5 degrees C. At the tested temperature below zero in combination with high relative humidity the sampler showed anomalous behaviour for NO2. The possible effect of concentration level and exposure time for NO2 needs further research. The average uptake rate for SO2 calculated from all exposures is 0.478 +/- 0.075 ng of sulfate ion each ppb min of SO2 and accords to suppliers uptake rate. No clear effects of temperature, relative humidity or concentration level/exposure time on the uptake rate for SO2 were found, partly due to the large scatter of results. Although NO2 accuracy of Radiello samplers was better during field campaigns than during laboratory validation, IVL and OGAWA samplers gave better results for NO2. In the field, IVL samplers showed best agreement with the continuous analyzers for both NO2 and SO2.  相似文献   

7.
Multivariate techniques have been applied to the set of dataobtained after one year sampling of volatile organic compounds(VOCs), including volatile aldehydes in the area of Madrid inorder to evaluate the possible correspondence among groups ofanalysed compounds, as far as modelling of different emissionsources in relation to location and season. The measurements were carried out at four sites in Madrid, characteristic for urban and suburban areas. Additionally, as reference, a rural area 100 km far from the city was considered. Results of correlation analysis, factor and cluster analysis are presented.Higher correlations were found between variables related withtraffic emissions. Factor analysis results showed two mainsignificant variables related to anthropogenic and biogenicemissions respectively. In relation to cluster analysis, samples were grouped according to sampling site and seasonal variations.  相似文献   

8.
Factors concerning NO2 uptake by the absorbent triethanolamine (TEA) in NO2 diffusion tubes are examined. Although the nominal freezing point of TEA is 17.9-21.2 degrees C, we show that, for a range of aqueous TEA solutions (0-20%, H2O), no freezing occurs even at -10 degrees C. Therefore NO2 collection efficiency is unlikely to be impaired by low temperature exposure. The recovery of TEA from the meshes of exposed samplers is determined as approximately 98%, even after 42 days, showing that the stability in situ of TEA is unaffected by long-term exposure. A model of a diffusion tube sampling array for simultaneous exposures, with a 0.1 m sampler spacing, shows that NO2 uptake by individual samplers is not affected by the presence of neighbouring tubes in the array. This is confirmed by sampler precision at two Cambridge sites. Four sampler preparation methods are compared for differences in NO2 uptake of exposed samplers. All methods employ TEA as absorbent, transferred by either dipping meshes in a TEA-acetone solution or pipetting aliquots of a TEA-H2O solution onto the meshes. For samplers prepared by three of the methods, no difference in NO2 uptake is found, but for samplers prepared using a 50% v/v TEA-H2O solution, a mean reduction of 18% is found. Student's t-tests show that the difference is highly significant (P < or = 0.001). Reasons for the difference are discussed.  相似文献   

9.
Studies on health effects of air pollutants ideally define exposure through the collection of air samples in the participants' homes. Concentrations derived from these samples are then considered as an estimate for the average concentration of air pollutants in the homes. Conclusions drawn from such studies therefore depend very much on the validity of the measured air pollution concentrations. In this paper we analysed repeated BTEX and NO(2) measurements with a time period of several months lying between the two conducted home visits. We investigated the variability of their concentrations over time by determining correlation coefficients and calculating within- and between-home variances. Our population consisted of 631 homes of participants from two cohort studies within the framework of the German study on Indoor Factors and Genetics in Asthma. Air pollutants were measured using passive samplers both indoors and outdoors. The measured BTEX concentrations were poorly correlated, with Pearson's correlation coefficient r ranging from -0.19 to 0.27. Additionally, a considerable seasonal effect could be observed. A higher correlation was found for the NO(2) concentrations with r ranging between 0.24 and 0.55. For the BTEX, the between-home variance was bigger than the within-home variance, for NO(2) both variances were of about the same order. Our results indicate that in a setting of moderate climate like in Germany, the variability of BTEX and NO(2) concentrations over time is high and a single measurement is a poor surrogate for the long-term concentrations of these air pollutants.  相似文献   

10.
Two studies at three sites in the UK provided confirmation that systematic positive bias in NO2 diffusion tube measurement occurred because of changes to "within-tube" chemistry, rather than eddy diffusion at the mouth of the tube. In the first study in Cambridge, UK, sampler overestimation for 1 and 2 week exposures was compared to corresponding time-averaged monitor measurements (NO-NO2-NOx, O3) and weather variables. Noninearity between sampler and monitor NO2 measurements was interpreted in terms of spatial and temporal variations in relative and absolute availability of NO, NO2 and O3 at the site. A maximum overestimation occurred for an exposure mean NO2/NOx approximately 0.5. The separate contributions of reduced NO2 photolysis and eddy diffusion were compared in Study II using samplers of two materials, acrylic and quartz, and of different lengths (40, 55, 71 and 120 mm) at three sites: Norwich background, Cambridge intermediate, London kerbside. For compared sites, NO2 measured by acrylic samplers was significantly higher than for equivalent quartz samplers. For quartz samplers [NO2]mean was only just above the monitor at Norwich and London; sampler/monitor NO2 = 1.04 (P = 0.59) and 1.01(P = 0.76), respectively. For acrylic samplers the order of [NO2]mean was 40 mm > 120 mm > 71 mm > or = 55 mm. Excepting 40 mm samplers, this accords with a chemical bias where co-diffusing NO and 03 molecules in longer tubes have more time to react to form excess NO2. Bias in 40 mm samplers is discussed. Eddy diffusion is negligible for standard samplers because [NO2]mean was equivalent for 55 mm and 71 mm acrylic samplers and close to monitor NO2 for 71 mm quartz tubes. Both studies showed that sampler accuracy was dependent on location. Significantly, overestimation was greatest (approximately 3-4 ppb) where the NO2 annual mean was approximately 20 ppb, close to the UK and EU air quality standard of 21 ppb.  相似文献   

11.
Low flow active sampling techniques collecting vapors and gases using thermally desorbable adsorbents are now feasible and desirable in many applications as they permit long integration times, the potential for miniaturized sampling configurations, and other advantages. At very low air flow rates (< 1 ml min(-1)), diffusive uptake on adsorbents in conventional sorbent tubes may equal or exceed the active (pumped) uptake rate, and even at low flow rates (1-4 ml min(-1)), diffusive uptake may significantly bias measurements. Thus, corrections to account for the diffusive flux or means to limit the diffusive uptake are needed in low flow applications. This paper presents (1) a theoretical analysis of the role of diffusive and advective uptake for several sampling geometries of tube-type samplers; (2) experimental confirmation using both laboratory and field studies; (3) estimates of the tortuosity and porosity of the glass wool packing used to retain the adsorbent, parameters needed to estimate diffusive fluxes in passive and active sampling; (4) a demonstration that orifice-equipped low flow active samplers can reduce diffusive uptake and improve precision, and (5) a model predicting the saturated adsorbent layer that helps to account for the gradual decline in uptake rates seen in passive sampling. Diffusive uptake will depend on the tube configuration and diffusion coefficient of the substance of interest, but for conventional sampling tubes (0.4-0.5 cm id, 1.5 cm air gap), sample flow rates should be maintained above 1 to 4 ml min(-1) to keep errors below 5%. Laboratory experiments showed close agreement with theoretical calculations, and the field study using 1 to 4 d sampling periods and 0.3 ml min(-1) flows demonstrated that the orifice-equipped samplers essentially eliminated diffusive uptake. No significant practical difficulties are encountered using orifices, e.g., pressure drop is minimal. Experimental estimates of tortuosity (0.79 +/- 0.02) and porosity (0.92 +/- 0.10) of the glass wool packing (0.3 cm length) represent relatively little resistance to diffusion; however, variation in the packing and adsorbent placement can degrade the precision achievable by passive samplers. Diffusion barriers, consisting most simply of an orifice, may be used to lower the diffusive uptake. A needle-type orifice permits flows below 0.1 ml min(-1) and is suitable for sampling periods as long as several weeks, and it provided greater precision than conventional open-ended sampling tubes (8% compared to 13%). Finally, the gradual decrease in diffusive fluxes often seen in passive sampling is attributed to additional resistance posed by a saturated adsorbent layer, in agreement with a simple model based on total VOCs and specific adsorptivity of the adsorbent.  相似文献   

12.
Spatial mapping of city-wide PBDE levels using an exponential decay model   总被引:1,自引:0,他引:1  
Passive air samplers (PAS) consisting of polyurethane foam (PUF) disks were deployed at 6 outdoor air monitoring stations in different land use categories (commercial, industrial, residential and semi-rural) to assess the spatial distribution of polybrominated diphenyl ethers (PBDEs) in the Brisbane airshed. Air monitoring sites covered an area of ~1143 km(2) and PAS were allowed to accumulate PBDEs in the city's airshed over three consecutive seasons commencing in the winter of 2008. The average sum of five (∑(5)) PBDEs (BDEs 28, 47, 99, 100 and 209) levels were highest at the commercial and industrial sites (12.7 ± 5.2 ng PUF(-1)), which were relatively close to the city center and were a factor of 8 times higher than residential and semi-rural sites located in outer Brisbane. To estimate the magnitude of the urban 'plume' an empirical exponential decay model was used to fit PAS data vs. distance from the CBD, with the best correlation observed when the particulate bound BDE-209 was not included (∑(5)-209) (r(2) = 0.99), rather than ∑(5) (r(2) = 0.84). At 95% confidence intervals the model predicts that regardless of site characterization, ∑(5)-209 concentrations in a PAS sample taken between 4-10 km from the city centre would be half that from a sample taken from the city centre and reach a baseline or plateau (0.6 to 1.3 ng PUF(-1)), approximately 30 km from the CBD. The observed exponential decay in ∑(5)-209 levels over distance corresponded with Brisbane's decreasing population density (persons/km(2)) from the city center. The residual error associated with the model increased significantly when including BDE-209 levels, primarily due to the highest level (11.4 ± 1.8 ng PUF(-1)) being consistently detected at the industrial site, indicating a potential primary source at this site. Active air samples collected alongside the PAS at the industrial air monitoring site (B) indicated BDE-209 dominated congener composition and was entirely associated with the particulate phase. This study demonstrates that PAS are effective tools for monitoring citywide regional differences however, interpretation of spatial trends for POPs which are predominantly associated with the particulate phase such as BDE-209, may be restricted to identifying 'hotspots' rather than broad spatial trends.  相似文献   

13.
Atmospheric BTEX [benzene, toluene, ethylbenzene, o-xylene and (m + p)-xylene] concentrations have been determined in the Naples metropolitan area (NMA) and in two suburban areas located on the north within about 25 km, during 2006. The pollutants were collected by passive samplers (24-h samplings), and analysed by GC-MS. In all the areas analysed the average atmospheric benzene concentrations were higher than the limit value fixed by the European Union for 2010 and in NMA the average concentration (9.8 microg m(-3)) also exceeded the limit fixed for 2006. High linear correlation coefficients between the average daily concentrations of the different BTEX are indicative of a single major source, most likely the vehicular traffic. The temporal and spatial distribution of BTEX relative concentrations suggest that massive emissions in NMA negatively affect the quality of the air in northern suburban areas, prevalently during the hottest months of the year, probably due to transport by local seasonal winds. The ratios between BTEX daily concentrations showed a clear dependence on the intensity of solar actinic flow, indicating a major role of photochemical processes in the air cleaning from these volatile organic pollutants.  相似文献   

14.
Diffusive sampling of Volatile Organic Compounds (VOCs) onto thermal desorption tubes, followed by gas chromatography, is an established technique for area or personal monitoring of typical workplace concentrations and there has been increasing interest in extending the application to environmental levels, particularly for benzene, toluene and xylene (BTX). Diffusive sampling rates for BTX on Chromosorb 106 and Carbograph-1 (a graphitised carbon) were measured over periods of 1-4 weeks in field validation experiments using ambient air and parallel pumped sampling (the reference method) at the HSL site in central Sheffield. The reference method was also used to investigate the possible bias of an open-path spectrophotometer (OPSIS) used by Sheffield City Council. A bias for BTX was suspected from results of a two-week initial exercise in which several diffusive samplers were placed close to the light path. In the full field validation of the diffusive samplers carried out subsequently, the significant bias of BTX concentrations reported by OPSIS were confirmed when compared with concurrent results from the reference method. OPSIS gave benzene and toluene values up to eight times higher than expected from the GC measurements. Xylene discrepancies were smaller, but in one 3-day peak episode, OPSIS demonstrated a negative correlation with GC.  相似文献   

15.
Mass Concentration of ambient particulate matter with an aerodynamic diameter less than 10µm (PM10) are reported for the first time for a range of sites in Dublin City over a 6 month period from January 1st 1996 to June 30th 1996. PM10 gravimetric mass concentration measurements are made with low flow Partisol 2000 air samplers using an impaction type PM10 inlet and 47mm diameter glass fibre filters. In addition, much finer time resolution measurements (minimum sampling frequency of 30 minutes) are made using a tapered element oscillating microbalance (TEOM) PM10 mass monitor. These PM10 mass concentrations methods are also compared with mass concentration inferred using the standard black smoke method. Analysis of the ambient mass concentration data with reference to traffic density and meteorological influences are presented. Results for the first six months of 1996 show that the average PM10 values range from a high of 49 µg m-3 at the Dublin city centre site to 14 µg m-3 at one of the suburban sites. Intercomparison between PM10 and black smoke mass concentrations show that the relationship is site specific. Statistical analysis between PM10 levels and car traffic number show a positive correlation while a weak negative correlation is found between PM10 levels and rainfall amount, wind speed and air temperature.  相似文献   

16.
Exposure to various chemicals can cause adverse effects to health, such as asthma and allergies, especially in children. Data on personal exposure levels in children are scarce, thus small lightweight diffusive mini-samplers for aldehydes and volatile organic compounds (VOCs) were designed to measure the exposure level of children to these chemicals. The aim of the study was to validate and examine the applicability of these mini-samplers for measuring daily chemical exposure. The diffusive mini-samplers are 20 mm in length, 11 mm in diameter, and 1.67 g in weight. The devices are cylindrically shaped with polytetrafluoroethylene membrane filters placed at each end. To measure aldehydes and acetone, 20 mg of 2,4-dinitrophenylhydrazine was used as an absorbent. To measure VOCs, a carbon molecular sieve was used. The sampling rate for each chemical was determined by parallel sampling with active samplers in a closed exposure bag. The blank levels of the chemicals and the storage stability of the device were tested. The mini-samplers were compared to commercially available diffusive samplers. To examine the applicability of the samplers, 65 elementary school children carried them for 24 h. The sampling rates for formaldehyde, acetaldehyde, and acetone were 20.9, 22.9, and 19.7 mL min(-1), respectively. The limits of quantification (LOQ) for the 24-hour sampling by high-performance liquid chromatography/ultraviolet (HPLC/UV) analysis were 8.3, 7.6, and 8.8 μg m(-3) for formaldehyde, acetaldehyde, and acetone, respectively. The sampling rates for the 11 VOCs were determined and ranged from 3.3 mL min(-1) for styrene and 2-ethyl-1-hexanol to 11.7 mL min(-1) for benzene. The LOQ for the 24-hour sampling by gas chromatography-mass spectrometry (GC-MS) analysis ranged from 5.9-105.2 μg m(-3), 1.1-24.7 parts per billion. The storage stability after 5 days ranged from 94.8 to 118.2%. Formaldehyde, acetone, benzene, and toluene were detected above the LOQ in more than 90% of the children, and the median concentrations were 21.7, 20.9, 10.1, and 21.5 μg m(-3), respectively. This study shows that the diffusive samplers developed were suitable for children to carry and were capable of measuring the children's daily chemical exposure.  相似文献   

17.
This paper presents the results of a feasability study for the preparation and certification of reference materials (RMs) for nitrogen dioxide (NO(2)) and sulfur dioxide (SO(2)) in diffusive samplers. RMs for NO(2) were prepared by exposure to gas mixtures in a chamber while the RMs for SO(2) were prepared by liquid spiking. Certification of RMs for NO(2) was found feasible with a certified uncertainty of 5.8% and a proposed shelf life of 5 years. The uncertainty was calculated with contribution from the homogeneity of preparation, stability and transport of the CRMs and from an external verification of the certified value. To reach 5.8% of uncertainty, the contribution of the differences between the results of analysis by ion chromatography and colorimetry must be eliminated. It is proposed to solve this by pre-extracting the samplers with water before analysis. The results of this study indicate that the samplers are stable for at least two years before and after exposure when stored in a refrigerator. By contrast, the certification of RMs for SO(2) was found to not be feasible due to instability problems. This instability was attributed to reaction of sulfate on the walls of the samplers. Alternatively, the preparation of RMs by simultaneous exposure to SO(2) and NO(2) has been tested. Satisfying homogeneities has been reached both for NO(2) and SO(2).  相似文献   

18.
High-frequency, continuous monitoring using in situ sensors offers a comprehensive and improved insight into the temporal and spatial variability of any water body. In this paper, we describe a 7-month exploratory monitoring programme in Dublin Port, demonstrating the value of high-frequency data in enhancing knowledge of processes, informing discrete sampling, and ultimately increasing the efficiency of port and environmental management. Kruskal–Wallis and Mann–Whitney tests were used to show that shipping operating in Dublin Port has a small–medium effect on turbidity readings collected by in situ sensors. Turbidity events are largely related to vessel activity in Dublin Port, caused by re-suspension of sediments by vessel propulsion systems. The magnitudes of such events are strongly related to water level and tidal state at vessel arrival times. Crucially, measurements of Escherichia coli and enterococci contamination from discrete samples taken at key periods related to detected turbidity events were up to nine times higher after vessel arrival than prior to disturbance. Daily in situ turbidity patterns revealed time-dependent water quality “hot spots” during a 24-h period. We demonstrate conclusively that if representative environmental assessment of water quality is to be performed at such sites, sampling times, informed by continous monitoring data, should take into account these daily variations. This work outlines the potential of sensor technologies and continuous monitoring, to act as a decision support tool in both environmental and port management.  相似文献   

19.
Identification of representative sampling sites is a critical issue in establishing an effective water quality monitoring program. This is especially important at the urban-agriculture interface where water quality conditions can change rapidly over short distances. The objective of this research was to optimize the spatial allocation of discrete monitoring sites for synoptic water quality monitoring through analysis of continuous longitudinal monitoring data collected by attaching a water quality sonde and GPS to a boat. Sampling was conducted six times from March to October 2009 along a 6.5 km segment of the Wen-Rui Tang River in eastern China that represented an urban-agricultural interface. When travelling at a velocity of ~2.4 km h(-1), this resulted in water quality measurements at ~20 m interval. Ammonia nitrogen (NH(4)(+)-N), electrical conductivity (EC), dissolved oxygen (DO), and turbidity data were collected and analyzed using Cluster Analysis (CA) to identify optimal locations for establishment of long-term monitoring sites. The analysis identified two distinct water quality segments for NH(4)(+)-N and EC and three distinct segments for DO and turbidity. According to our research results, the current fixed-location sampling sites should be adjusted to more effectively capture the distinct differences in the spatial distribution of water quality conditions. In addition, this methodology identified river reaches that require more comprehensive study of the factors leading to the changes in water quality within the identified river segment. The study demonstrates that continuous longitudinal monitoring can be a highly effective method for optimizing monitoring site locations for water quality studies.  相似文献   

20.
Vehicular traffic is one of the main sources of antimony in highly populated urban areas like Buenos Aires where an overall traffic density of 1 500 000 vehicles per day (corresponding to 7500 vehicles km(-2)) is estimated. In this context, a study was undertaken to ascertain the levels of Sb and other traffic-related elements (TRE) in the atmosphere of this city. To this end, sixty-seven samples of PM-10 particulate matter were collected during eight days in nine representative sampling sites located downtown Buenos Aires and spread over an area of about 30 km2. The collection of particulate matter was performed on ash-free glass-fibre filters using high volume samplers with PM-10 sampling heads. A combination of aqua regia and perchloric acid was used for leaching metals from filters. The resulting solutions were evaporated and then diluted with 0.1 mol l(-1) HCl. Antimony was determined by inductively coupled plasma-quadrupole mass spectrometry (ICP-QMS) at ng g(-1) levels. Concentrations of Sb varied from 12.9 +/- 0.9 to 375 +/- 23 microg g(-1)(equivalent to 0.87 +/- 0.06 to 15.3 +/- 0.8 ng m(-3)). Statistical analysis was performed on the data set including the measured PM-10 mass and Sb concentrations for the monitored period. Correlations of Sb with other TRE namely, Cu and Mo were also assessed. The highest concentrations of Sb were detected at two sites (Hospital Alemán and Casa Rapallini) located in streets with traffic consisting mostly of passenger cars and showing a "stop-and-go" pattern in peak hours. Antimony levels in the Buenos Aires PM-10 are by far below the level of 0.5 mg m(-3)(for an 8 hour workday, 40 hour work week) set by the US Occupational Safety and Health Administration (OSHA) for occupational exposure. However, monitoring of Sb and other TRE should be carried out in a systematic fashion to detect the possibility of increases in from the present levels.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号