首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The need for ambient gaseous ammonia (NH(3)) measurements has increased in the last decade as reactive NH(3) concentrations and deposition fluxes show little change even with tightening standards on nitrogen oxides (NO(x)) emissions. Currently, there are several networks developing methods for adding NH(3) measurements in the U.S. Gaseous NH(3) measurements will provide scientists and policymakers data which can be used to estimate ecosystem inputs, validate air quality models including trends and regional variability, and evaluate changes to the environment based on additional emission reduction requirements and estimates of critical nitrogen load exceedances. The passive samplers described in this paper were deployed in duplicate or triplicate and collocated with annular denuders or continuous instruments to determine their accuracy. The samplers assessed included the Adapted Low-Cost Passive High Absorption (ALPHA), Radiello(?), and Ogawa passive samplers. The median relative percent differences (MRPD) between the reference method and passive samplers for the ALPHA, Radiello(?) and Ogawa were -2.4%, -37% and -44%, respectively. The precision between duplicate samplers for the ALPHA and Ogawa samplers, was 7% and 6%, respectively. Triplicate Radiello(?) precision was assessed using the coefficient of variation (CV). The CV for the Radiello(?) samplers was 10%. This article discusses the statistical results from these studies.  相似文献   

2.
A study of the equivalence to the reference methods of the Radiello samplers for ozone (O(3)) and benzene as well as the membrane-closed Palmes tube (MCPT) for nitrogen dioxide (NO(2)) is presented. These samplers benefit from new model equations capable of estimating their uptake rate. For O(3), the aim here was to demonstrate the equivalence for the reference period of 8 h and 120 microg m(-3), the target value of the 3rd European Daughter Directive. For benzene, the demonstration of equivalence to the annual limit value of 5 microg m(-3) of the 2nd European Daughter Directive was examined. In the case of NO(2), the equivalence to the annual limit value of the 1st European Daughter Directive (40 microg m(-3)) was considered. Results show that the radial sampler for O(3) fails to meet the Data Quality Objective (DQO) for continuous monitoring. However, with an expanded uncertainty of less than 30%, the O(3) diffusive sampler fulfils the DQO for indicative measurements. For benzene, the Radiello sampler exposed for 7 days gave satisfying results showing the ability of the sampler to meet the DQO of the reference method. Nevertheless, the field tests should be complemented by measurements for a wider range of benzene concentrations. In the case of NO(2), all the results of the laboratory and field experiments respected the requirements necessary for the demonstration of equivalence. Overall, these findings thus show that the Radiello sampler and the MCPT are equivalent to the reference methods only for assessment of benzene and NO(2), respectively.  相似文献   

3.
The effect of different sampling exposure times and ambient air pollutant concentrations on the performance of Radiello? samplers for analysis of volatile organic compounds (VOCs) is evaluated. Quadruplicate samples of Radiello? passive tubes were taken for 3, 4, 7 and 14 days. Samples were taken indoors during February and March 2010 and outdoors during July 2010 in La Canonja (Tarragona, Spain). The analysis was performed by automatic thermal desorption (ATD) coupled with capillary gas chromatography (GC)/mass spectrometry detection (MS). The results show significant differences (t-test, p < 0.05) between the amounts of VOCs obtained from the sum of two short sampling periods and a single equivalent longer sampling period for 65% of all the data. 17% of the results show significantly larger amounts of pollutant in the sum of two short sampling periods. Back diffusion due to changes in concentrations together with saturation and competitive effects between the compounds during longer sampling periods could be responsible for these differences. The other 48% of the results that are different show significantly larger amounts in the single equivalent longer sampling period. The remaining 35% of the results do not show significant differences. Although significant differences are observed in the amount of several VOCs collected over two shorter sampling intervals compared to the amount collected during a single equivalent longer sampling period, the ratios obtained are very close to unity (between 0.7 and 1.2 in 75% of cases). We conclude that Radiello? passive samplers are useful tools if their limitations are taken into account and the manufacturer's recommendations are followed.  相似文献   

4.
This study describes the field evaluation of a tailor-made new glass passive sampler developed for the determination of NO(2), based on the collection on triethanolemine (TEA)-coated fibre filter paper. The sampler has been derived from a Palmes design. The overall uncertainty of the sampler was determined by using Griess-Saltzman ASTM D 1607 standard test method as a reference method. The agreement between the results of the passive sampler and the reference method was +/-7.90% with the correlation coefficient of 0.90. Method precision in terms of coefficient of variance (CV) for three simultaneously applied passive samplers was 8.80%. The uptake rate of NO(2) was found to be 2.49 ml/min in a very good agreement with the value calculated from theory (2.63 ml/min). Sampler detection limit was 1.99 microg/m(3) for an exposure period of 1 week and the sampler can be stored safely for a period of up to 6 weeks before exposure. A comparison of the sampler performance was conducted against a commercially available diffusion tube (Gradko diffusion tube). The results from the applied statistical paired t test indicated that there was no significant difference between the performances of two passive samplers (R (2) > 0.90). Also, another statistical comparison was carried out between the dark and transparent glass passive samplers. The results from the dark-colour sampler were higher than that from the transparent sampler (approximately 25%) during the summer season because of the possible photodegradation of NO(2)-TEA complex.  相似文献   

5.
Two-week average NO2 concentrations were measured in Amsterdam (NL), Huddersfield (UK) and Prague (CZ) at 80 sites in each study area, to assess small area spatial variation, using a tube type and a badge type passive sampler. The badges appeared to be less robust than the tubes. The lower detection limit for tubes and badges was 3.7 and 0.91 µg/m3, respectively for fortnightly measurements. Accuracy of the samplers was determined with reference methods (chemiluminescence). The mean ratio of the concentration measured by diffusion tube over that by the reference method was 1.16, 1.03 and 0.77 in Amsterdam, Huddersfield and Prague, respectively. Standardizing the badges for the results obtained in Amsterdam, the relative mean ratio of the concentration measured by the badges over that by the reference method was 0.95 and 0.58 in Huddersfield and Prague, respectively. NO2 concentrations measured by the two designs did not differ significantly. Mean NO2 concentrations were 36, 26 and 22 µg/m3 in Amsterdam, Huddersfield and Prague, respectively. The precision of duplicate tubes and badges was 8% and 11%, respectively. Both samplers are suitable for determining real variation in small area NO2 concentrations in the ranges which occurred. It is concluded that low-cost, simple NO2 passive samplers can provide reliable information about variation in NO2 concentrations within urban or rural areas on a small spatial scale. Based on its robustness and its precision, tubes were preferred over badges.  相似文献   

6.
Ambient ammonia concentrations, mainly originating from agricultural activities, have increased in the last few decades in Europe. As a consequence, critical loads on oligotrophic ecosystems such as forests and mires are greatly exceeded. Monitoring of ambient ammonia concentrations is necessary in order to investigate source-receptor relationships. Measuring ambient ammonia concentrations continuously with high time resolution is very expensive and cost-efficient systems are required. Where time resolution is of minor importance, several cost-effective systems, mainly dry denuder and passive samplers, can be applied. In this paper the Zürcher passive sampler, a diffusive sampling system, is presented. It is a Palmes type sampler with an acidic solution as absorbent and is easy to handle. It was tested at 46 sites in Switzerland over one year. The average concentration in ambient air was 2.5 microg m(-3) +/- 0.4 microg m(-3). The average of the blank values were 0.21 microg m(-3). The detection limit (double the standard deviation of the blank values) was 0.36 microg m(-3). Three passive samplers were exposed at each site and each period. The mean standard deviation of these triplicate measurements was 9.5%. Compared with a discontinuous tubular denuder system and a continuous annular denuder system, the deviation was less than 10%. The Zürcher passive sampler is a useful and cost-efficient tool to determine long-term average ammonia concentrations (one- to four-week periods) in ambient air for mean concentrations above 1 microg m(-3).  相似文献   

7.
Ambient ammonia monitoring using Ogawa passive samplers was conducted in the Four Corners area and eastern Oklahoma, USA during 2007. The resulting data will be useful in the multipollutant management of ozone, nitrogen oxides, and visibility (atmospheric regional haze) in the Four Corners area, an area with growing oil/gas production and increasing coal-based power plant construction. The passive monitoring data also add new ambient ammonia concentration information for the U.S. and will be useful to scientists involved in present and future visibility modeling exercises. Three week integrated passive ammonia samples were taken at five sites in the Four Corners area and two sites in eastern Oklahoma from December, 2006 through December, 2007 (January, 2008 for two sites). Results show significantly higher regional background ammonia concentrations in eastern Oklahoma (1.8 parts per billion (ppb) arithmetic mean) compared to the Four Corners area (0.2 ppb arithmetic mean). Annual mean ammonia concentrations for all Four Corners area sites for the 2007 study ranged from 0.2 ppb to 1.5 ppb. Peak ambient ammonia concentrations occurred in the spring and summer in both areas. The passive samplers deployed at the Stilwell, Oklahoma site compared favorably with other passive samplers and a continuous ammonia monitoring instrument.  相似文献   

8.
A combined NO2-SO2 Radiello radial-type diffusive sampler was validated under controlled laboratory conditions and compared with NO2-SO2 results of 3 other type of samplers in a field comparison at two locations Ghent-Mariakerke and Borgerhout in Flanders. Laboratory exposures at different temperatures (-5, 10 and 30 degrees C) and relative humidities (0, 50 and 80% RH) in combination with varying concentration levels and exposure times were carried out, with a focus on extreme conditions. Concentration level and exposure time were changed together following suppliers linear working range of samplers and assuring absolute amounts of compounds on the sampler corresponding to those of environmental levels. The average uptake rate for NO2 for 24 hour exposures at 10 degrees C and 50% RH and tested concentration levels (+/-73, 146 and 293 ppb NO2) was 0.076 +/- 0.011 ng ppb(-1) min(-1). Uptake rates during all experiments were lower than the uptake rate given in the instruction manual of the sampler. A significant effect of temperature and relative humidity on NO2 uptake rate was observed. The temperature effect from 10 to 30 degrees C corresponds to the temperature effect given by the supplier of the samplers. High relative humidity (70 to 80%) caused a strong non-reproducible decrease of uptake rate for NO2 at 24 hour experiments but this effect was not observed at longer exposures except for the tests at -5 degrees C. At the tested temperature below zero in combination with high relative humidity the sampler showed anomalous behaviour for NO2. The possible effect of concentration level and exposure time for NO2 needs further research. The average uptake rate for SO2 calculated from all exposures is 0.478 +/- 0.075 ng of sulfate ion each ppb min of SO2 and accords to suppliers uptake rate. No clear effects of temperature, relative humidity or concentration level/exposure time on the uptake rate for SO2 were found, partly due to the large scatter of results. Although NO2 accuracy of Radiello samplers was better during field campaigns than during laboratory validation, IVL and OGAWA samplers gave better results for NO2. In the field, IVL samplers showed best agreement with the continuous analyzers for both NO2 and SO2.  相似文献   

9.
Long-term phenol, cresols and BTEX monitoring in urban air   总被引:1,自引:0,他引:1  
This paper reports the results of a long-term monitoring of benzene, toluene, ethylbenzene, xylenes (BTEX), phenol and cresols in the air of Padua during a wide period of the year 2007 using two radial passive samplers (Radiello system) equipped with BTEX- and phenol-specific cartridges. Two sites were monitored, one in the industrial area and one close to the town centre. Relevant pollution episodes have been observed during both the winter and summer periods. Benzene, together with toluene, ethylbenzene and xylenes showed their maximum concentrations during the winter season, but the secondary pollutant phenol was higher than benzene for a large period of the year when the meteorological conditions blocked the pollutants in the lower layers of the atmosphere and solar radiation increased the benzene photo-oxidation process.  相似文献   

10.
This study describes the determination of trace levels of copper by slotted quartz tube atomic absorption spectrometry after dispersive liquid-liquid microextraction. A ligand synthesized from the reaction of salicylaldehyde and 1-naphthylamine was used to form coordinate copper complex prior to extraction. All parameters that influence the output of complex formation, extraction, and instrumental measurement were optimized to enhance the absorbance signal of copper. Under the optimum conditions, about 104-fold enhancement in sensitivity was recorded over the conventional flame atomic absorption spectrometer, corresponding to a 0.51 ng/mL detection limit. The percent relative standard deviation calculated for the lowest concentration (4.8%) indicated high precision for the experimental procedure. Accuracy and applicability of the optimum method were determined by performing spiked recovery tests on urine, lake water, and mineral water samples. Satisfactory recovery results were obtained between 82.2 and 106.3% at four different concentrations. Matrix matching method was also performed to increase the accuracy of quantification, and the percent recovery calculated for 175 ng/mL was 105.14%.  相似文献   

11.
Assessment of population exposure to VOC in ambient atmospheres is receiving heightened interest as the adverse health effects of chronic exposure to certain of these compounds are identified. Active (pumped) and passive samplers are the most commonly used devices for this type of monitoring. It has been shown, however, that these devices, along with all other preconcentration techniques, are susceptible to ozone interference. It is demonstrated that this interference occurs even at low ozone concentrations and that it may result in the under-estimation of population exposure. A convenient and effective ozone scrubbing method is identified and successfully applied and validated for both active and passive samplers for a range of VOC.  相似文献   

12.
Two studies at three sites in the UK provided confirmation that systematic positive bias in NO2 diffusion tube measurement occurred because of changes to "within-tube" chemistry, rather than eddy diffusion at the mouth of the tube. In the first study in Cambridge, UK, sampler overestimation for 1 and 2 week exposures was compared to corresponding time-averaged monitor measurements (NO-NO2-NOx, O3) and weather variables. Noninearity between sampler and monitor NO2 measurements was interpreted in terms of spatial and temporal variations in relative and absolute availability of NO, NO2 and O3 at the site. A maximum overestimation occurred for an exposure mean NO2/NOx approximately 0.5. The separate contributions of reduced NO2 photolysis and eddy diffusion were compared in Study II using samplers of two materials, acrylic and quartz, and of different lengths (40, 55, 71 and 120 mm) at three sites: Norwich background, Cambridge intermediate, London kerbside. For compared sites, NO2 measured by acrylic samplers was significantly higher than for equivalent quartz samplers. For quartz samplers [NO2]mean was only just above the monitor at Norwich and London; sampler/monitor NO2 = 1.04 (P = 0.59) and 1.01(P = 0.76), respectively. For acrylic samplers the order of [NO2]mean was 40 mm > 120 mm > 71 mm > or = 55 mm. Excepting 40 mm samplers, this accords with a chemical bias where co-diffusing NO and 03 molecules in longer tubes have more time to react to form excess NO2. Bias in 40 mm samplers is discussed. Eddy diffusion is negligible for standard samplers because [NO2]mean was equivalent for 55 mm and 71 mm acrylic samplers and close to monitor NO2 for 71 mm quartz tubes. Both studies showed that sampler accuracy was dependent on location. Significantly, overestimation was greatest (approximately 3-4 ppb) where the NO2 annual mean was approximately 20 ppb, close to the UK and EU air quality standard of 21 ppb.  相似文献   

13.
Low flow active sampling techniques collecting vapors and gases using thermally desorbable adsorbents are now feasible and desirable in many applications as they permit long integration times, the potential for miniaturized sampling configurations, and other advantages. At very low air flow rates (< 1 ml min(-1)), diffusive uptake on adsorbents in conventional sorbent tubes may equal or exceed the active (pumped) uptake rate, and even at low flow rates (1-4 ml min(-1)), diffusive uptake may significantly bias measurements. Thus, corrections to account for the diffusive flux or means to limit the diffusive uptake are needed in low flow applications. This paper presents (1) a theoretical analysis of the role of diffusive and advective uptake for several sampling geometries of tube-type samplers; (2) experimental confirmation using both laboratory and field studies; (3) estimates of the tortuosity and porosity of the glass wool packing used to retain the adsorbent, parameters needed to estimate diffusive fluxes in passive and active sampling; (4) a demonstration that orifice-equipped low flow active samplers can reduce diffusive uptake and improve precision, and (5) a model predicting the saturated adsorbent layer that helps to account for the gradual decline in uptake rates seen in passive sampling. Diffusive uptake will depend on the tube configuration and diffusion coefficient of the substance of interest, but for conventional sampling tubes (0.4-0.5 cm id, 1.5 cm air gap), sample flow rates should be maintained above 1 to 4 ml min(-1) to keep errors below 5%. Laboratory experiments showed close agreement with theoretical calculations, and the field study using 1 to 4 d sampling periods and 0.3 ml min(-1) flows demonstrated that the orifice-equipped samplers essentially eliminated diffusive uptake. No significant practical difficulties are encountered using orifices, e.g., pressure drop is minimal. Experimental estimates of tortuosity (0.79 +/- 0.02) and porosity (0.92 +/- 0.10) of the glass wool packing (0.3 cm length) represent relatively little resistance to diffusion; however, variation in the packing and adsorbent placement can degrade the precision achievable by passive samplers. Diffusion barriers, consisting most simply of an orifice, may be used to lower the diffusive uptake. A needle-type orifice permits flows below 0.1 ml min(-1) and is suitable for sampling periods as long as several weeks, and it provided greater precision than conventional open-ended sampling tubes (8% compared to 13%). Finally, the gradual decrease in diffusive fluxes often seen in passive sampling is attributed to additional resistance posed by a saturated adsorbent layer, in agreement with a simple model based on total VOCs and specific adsorptivity of the adsorbent.  相似文献   

14.
A method is presented for the determination of antimony in whole human blood samples with an ICP-MS instrument using a quadrupole mass analyzer. A nitric acid/hydrogen peroxide open digestion procedure was employed for the blood sample treatment and preparation for analysis. The precision and accuracy of the method were evaluated by analyzing several Seronorm trace elements whole blood reference materials. The precision of the method at various antimony levels was better than 4% RSD and the recovery was greater than 92% at all levels. The detection limit, calculated as three times the standard deviation of the blank (3sigma, n= 12), was 0.03 microg L(-1). The method was successfully applied for the determination of antimony in blood samples from school children in rural areas of Kwazulu/Natal, South Africa and adults from Dearborn, Michigan. Blood antimony levels ranged from <0.03 to 3.82 microg L(-1) in children and 1.40 to 4.35 microg L(-1) for adults.  相似文献   

15.
研究了便携式X荧光光谱仪(PXRF)测定土壤中砷、铅、铬、铜、锌和镍的性能,评估其检出限、精密度和准确度,探索了土壤水分和粒径对测定结果的影响程度,并与常规实验室分析方法测定结果进行比对。结果表明,PXRF测定土壤中砷、铅、铬、铜、锌和镍的检出限为5~15mg/kg,标准物质测定结果的相对标准偏差(RSD)≤8.6%,相对误差在±15%以内。随着土壤水分含量的增加,各金属元素测定结果均呈下降趋势,而RSD有上升趋势。土壤粒径对测定结果的影响较小,随着土壤粒径减少,各金属元素测定结果的RSD略有下降趋势。PXRF可以简单、快速地测定多种重金属元素,适用于污染地块重金属元素的现场实时监测。  相似文献   

16.
A biennial integrated survey, based on the use of vascular plants for the bioindication of the effects of tropospheric ozone, was performed in the area of Pisa (Tuscany, Central Italy). It also investigated the distribution of selected trace elements in plants and the data were compared with those obtained from the use of passive samplers, automatic analysers of ozone and lichen biodiversity. Photochemically produced ozone proved to be present during the warm season, with maximum hourly means surpassing 100 ppb: the use of supersensitive tobacco Bel-W3 confirmed the value of detailed, cost-effective, monitoring surveys. Trials with clover clones demonstrate that sensitive plants undergo severe biomass reduction in the current ozone regime. The mean NC-S (clover clone sensitive to ozone):NC-R (resistant) biomass ratio ranged from 0.7 (in 1999) to 0.5 (in 2000). The economic impact of these reductions deserves attention. The data obtained using passive ozone samplers exceeded those obtained using an automatic analyser. The mapping of epiphytic lichen biodiversity was not related to the geographical ozone distribution as can be seen from the tobacco's response. Lettuce plants grown under standardized conditions were used positively as bioaccumulators of trace elements: Pb was abundantly recovered, but a large portion of this element was removed by washing.  相似文献   

17.
阐述了GC/MS内标法测定土壤中多环芳烃时质量控制的基本内容、基本方法和基本操作。测定结果为:空白分析结果均小于检出限;空白加标精密度和准确度分别在7.80%~25.2%和49.2%~96.6%之间;样品加标精密度和准确度分别在7.77%~19.8%和67.2%~122%之间;检出限在0.05~0.08 mg/kg之间...  相似文献   

18.
通过标准曲线、检出限和测定范围、方法精密度、方法准确度、实际海水样品测定结果、加标回收率、分析效率和物料消耗这几方面比较了过硫酸钾氧化法、流动注射分析法和高温氧化-化学发光检测法这3种测定海水中总氮(TN)方法的优缺点。结果表明,流动注射分析法和高温氧化-化学发光检测法的测定范围更宽,精密度、准确度更好,3种样品的加标回收率达到96.2%~101%;高温氧化-化学发光检测法分析效率高、物料消耗少、节能环保,适用于一般海水样品的批量分析,且由于测定范围大,该法也适用于TN浓度较高的海水样品的批量分析,流动注射分析法因其较低的检出限更适用于TN浓度较低的海水样品的批量分析。  相似文献   

19.
A rapid, empirical method is described for estimating weekly AOT40 from ozone concentrations measured with passive samplers at forest sites. The method is based on linear regression and was developed after three years of measurements in Trentino (northern Italy). It was tested against an independent set of data from passive sampler sites across Italy. It provides good weekly estimates compared with those measured by conventional monitors (0.85 ≤R(2)≤ 0.970; 97 ≤ RMSE ≤ 302). Estimates obtained using passive sampling at forest sites are comparable to those obtained by another estimation method based on modelling hourly concentrations (R(2) = 0.94; 131 ≤ RMSE ≤ 351). Regression coefficients of passive sampling are similar to those obtained with conventional monitors at forest sites. Testing against an independent dataset generated by passive sampling provided similar results (0.86 ≤R(2)≤ 0.99; 65 ≤ RMSE ≤ 478). Errors tend to accumulate when weekly AOT40 estimates are summed to obtain the total AOT40 over the May-July period, and the median deviation between the two estimation methods based on passive sampling is 11%. The method proposed does not require any assumptions, complex calculation or modelling technique, and can be useful when other estimation methods are not feasible, either in principle or in practice. However, the method is not useful when estimates of hourly concentrations are of interest.  相似文献   

20.
对便携式催化氧化-FID法测定非甲烷总烃的检出限、精密度、准确度、催化效率等性能指标开展研究,考察该方法测定固定污染源废气中非甲烷总烃的适用性。结果表明:催化氧化装置的转化效率为98.1%~99.7%,方法检出限为0.05 mg/m3(以碳计);2个质量浓度水平的甲烷和丙烷混合标准气体测定结果的相对误差分别为-6.4%~6.1%、-4.7%~-0.5%,实验室内、实验室间测定结果的RSD分别为2.9%~5.9%和1.6%~2.5%、1.5%和0.6%。用该方法和国标法同时测定实际样品,两种方法测定结果的相对误差为6.4%~21.4%。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏