首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
焦化废水深度处理试验研究   总被引:1,自引:0,他引:1  
王娟  刘玉学  范迪 《环境工程学报》2009,3(10):1804-1807
采用BC法+复合过滤技术工艺对焦化废水生化出水进行深度处理试验。结果表明,在SE混凝剂投药量为30 mg/L、BC池停留时间为1.5 h、复合过滤器水力负荷为2.4 m3/(m2·h)的条件下,当深度处理进水水质为COD=196.1 mg/L、色度=120倍、NH3-N=35.1 mg/L时,其去除率分别为74.7%、86.7%和69.7%,出水可达回用水要求。  相似文献   

2.
开发了一种处理农村污水的低能耗地埋式一体化溅水充氧生物滤池装置,通过拔风和溅水复合充氧技术实现了大幅度节能条件下的好氧生物处理.考察了在不同水力负荷及COD、NH4 -N容积负荷条件下本装置的处理效果,结果表明,在水力负荷小于10 m3/(m2·d)、COD及NH4 -N容积负荷分别小于0.3 kg COD/(m3·d)和0.08 kg NH4 -N/(m3·d)的条件下,可以取得较高的去除效果和良好的出水水质,COD、NH4 -N和TN的平均出水浓度分别为58.94 mg/L、2.78 mg/L和8.23 mg/L,平均去除率分别为51.7%、86.4%和70.6%.  相似文献   

3.
Many rivers in China and other newly industrialized countries have suffered from severe degradation of water quality in the context of rapid economic growth. An accounting method was developed to investigate the source and mass fluxes of the main contaminants in the Ziya River, a severely polluted and heavily modified river in a semiarid area of the North China Plain, where chemical oxygen demand (COD) and ammonia nitrogen (NH4-N) were the most important indicators of pollution. The results showed that the urban sewage with high concentration of COD and NH4-N dominated the streams, contributing to 80.7 % of the streamflow, 92.2 % of COD, and 94.5 % of NH4-N. The concentrations of COD and NH4-N in streams varied from 24.0–195.0 to 5.8–43.8 mg/L, respectively. Mass fluxes of COD and NH4-N of all pathways were quantified. Much of the polluted water was diverted to irrigation, and some eventually flowed into the Bohai Sea. Installation of adequate wastewater treatment facilities and making strict discharge standards can help improve the water quality. Our findings imply that a simple accounting method provides an extremely well-documented example for load estimation and can be useful for intervention strategies in heavily polluted and modified rivers in newly industrialized countries.  相似文献   

4.
厌氧-好氧工艺处理制药废水的中试研究   总被引:3,自引:0,他引:3  
将由厌氧折流板反应器(ABR)、移动床生物膜反应器(MBBR)和膜生物反应器(MBR)组合而成的厌氧-好氧工艺用于处理制药废水的中试研究.试验结果表明,当原水SS平均值为1000 mg/L,COD为10 000 mg/L,NH3-N为500 mg/L时,出水浊度、COD和NH3-N分别为3 NTU、500 mg/L以及10 mg/L以下,去除率分别为98%、95%和98%以上.  相似文献   

5.
介绍了内蒙古某抗生素废水处理厂的处理工艺流程、处理单元类型及其详细设计参数,通过对该污水处理厂半年内运行效果的调研,分析评价该污水处理系统的处理效果及出水指标;该水厂工艺流程对COD、TOC、氨氮、总氮、总磷、BOD和急性毒性的平均去除率分别为96.52%、95.83%、50.24%、55.20%、62.05%、98.52%和99.14%,COD、氨氮、总氮、总磷出水水质分别为477、438、556.7和7.69 mg/L,达到排放到城区下水道要求,园区内所有废水汇集到园区污水处理厂进行集中深度处理达标后排放水体。通过对该水厂工艺的介绍和水质分析,为我国抗生素生产企业面临的废水处理工艺类型选择及工程改造升级提供一定参考。  相似文献   

6.
邹高龙 《环境工程学报》2014,8(6):2467-2472
针对城市生活污水,研究了两点进水倒置A2/O-MBR(平板膜)系统(以下简称系统)对COD、NH+4-N、TN、TP、出水SS影响。结果表明,该系统对COD、NH+4-N具有较高的去除率,出水符合GB18918-2002中一级A标准;当混合液回流比为200%时,系统出水TN浓度小于15 mg/L;正常排泥后,系统对TP的去除率达83%左右;平板膜破损会导致出水SS、COD会受到影响。膜对COD、TP、SS有直接截留作用,由于系统出水几乎没有固体损失,可以精确控制污泥龄,有利于世代周期较长的硝化菌和反硝化菌生长;系统中的污泥浓度可以提高至15 000 mg/L,此时,即使进水量提高0.5倍,出水水质仍保持良好。  相似文献   

7.
采用Fenton氧化-序批式膜生物反应器(SBMBR)组合工艺处理干法腈纶废水。结果表明,在废水初始pH值为3.0,H2O2投加量为90.0 mmol/L,Fe2+投加量为20.0 mmol/L,反应时间为2.0 h的条件下,Fenton氧化预处理对腈纶生产废水的COD去除率达到47.0%以上,COD由1 091 mg/L降至560 mg/L,废水的BOD5/COD由0.32升至0.69,废水的可生化性得到显著提高。Fenton处理出水与丙烯腈废水等比例混合后,采用SBMBR进行生化处理,在水力停留时间为24 h,90 min缺氧/150 min好氧交替运行的条件下,COD、NH4+-N和TN的平均去除率分别为71.7%、97.2%和47.4%,碳源不足是限制TN去除效果的主要影响因素。在无外加碳源的条件下,组合工艺处理后出水COD和NH4+-N浓度分别为117 mg/L和1.7 mg/L,出水水质可以稳定达到国家一级排放标准(GB8978-1996)。  相似文献   

8.
垃圾渗滤液是公认的一种成分复杂且难以处理的高浓度有机废水,笔者在北京市海淀区六里屯垃圾填埋场通过2007—2010年垃圾渗滤液处理的工程实践,以COD和氨氮的去除率为指标,研究了不同的垃圾渗滤液处理工艺组合,以及不同运行参数条件下对垃圾渗滤液的处理效果。结果表明,在中温UASB和A/O的平均水力停留时间(HRT)缩短1/3的情况下,通过改进A/O段曝气方式,优化系统的pH、DO等运行参数,用MBR替代絮凝工艺,使整个组合工艺对COD的年平均去除率达到了94.3%,氨氮的去除率维持在99.5%以上,出水氨氮稳定在10 mg/L以内,而改造前的COD与氨氮的年平均去除率仅为82.2%与55.3%。与改造前的UASB+A/O+絮凝工艺组合相比,改造后的UASB+A/O+MBR工艺组合具有更高的污染物去除能力、更好的抗缓冲性和稳定性。  相似文献   

9.
朱毅  李晓霞  王俊  李春 《环境工程学报》2012,6(9):2995-3000
针对大豆深加工高浓度有机废水厌氧出水的特点,采用移动床生物膜反应器-沉淀池-厌氧池(MBBR-SA)工艺进行处理,重点考察了其COD去除、脱氮以及污泥减量化的性能。处理前厌氧出水水质参数为COD 1 350~1 851 mg/L、TN 45~73 mg/L和TP 35~55 mg/L。结果表明,经过70 d的运行,在最佳水力停留时间(HRT)1.68 d与最佳回流比0.75条件下,出水平均COD、TN和NH4+-N浓度分别为91.5、12.4和11.4 mg/L,分别达到了《城镇污水处理厂污染物排放标准》二级标准、二级标准和一级B标准,其平均去除率分别为96.0%、87.4%和88.3%;该工艺未排放剩余污泥,其表观污泥产率为0.13,比MBBR降低了43.5%,具有明显的污泥减量化特性。  相似文献   

10.
Biostyr曝气生物滤池处理城市污水的沿程生化特性   总被引:1,自引:0,他引:1  
王琳  窦娜莎 《环境工程学报》2013,7(8):2942-2946
青岛市麦岛污水处理厂采用曝气生物滤池(BAF)处理城市污水,以稳定运行的Biostyr为研究载体,考察滤池COD、NH3-N、SS和细菌数量等生化特性的沿程变化.结果表明,在气水比为4∶1~5∶1、进水COD负荷为2.5 ~3.7 kg/(m3·d)、进水NH3-N负荷为0.18~0.57 kg/(m3·d)时,滤池对COD的降解主要在150 cm填料以下处,COD的去除率可达58.9%;NH3-N去除率沿滤柱高度的变化与COD有所不同,在100 cm以下填料处,NH3-N的去除率仅为3.6%,在100 ~350 cm填料之间,NH3-N的去除率增加迅速,可达56.1%;对SS的去除主要发生在100 cm填料以下,去除率达51.7%.  相似文献   

11.
介绍了美国某污水处理厂的处理工艺流程、主要构筑物构成及其设计参数,通过对该污水处理厂一年内运行效果的调研,分析评价了该污水厂的进出水水质指标;该水厂工艺流程对TSS、BOD5、COD、NH3-N、TP和浊度的年平均去除率分别可以达到97.7%、97.7%、93.5%、82.6%、95.2%和97.9%,各项出水水质均优于我国《城镇污水处理厂污染物排放标准》(GB18918-2002)一级A标准,通过对该水厂工艺的介绍和分析,为我国污水厂的建设及改造升级提供了一定的参考依据.  相似文献   

12.
The present study was aimed to characterize physico-chemical and microbial population of distillery effluent and isolate a novel thermotolerant bacterium for color, COD, and BOD reduction of spentwash. The level of alkalinity, TSS, DO, COD, BOD, TN, ammonical nitrogen, nitrate nitrogen, phosphorous, potassium, chloride, and calcium of spentwash (SW), bioreactor effluent (BE), and secondary treated effluent (STE) were well above the permissible limits. The level of color, TS, and TDS were under the permissible limits for STE but not for SW and BE. The microbial population was higher in BE. The results revealed that effluent was highly polluted and require suitable treatment before discharge. A novel thermotolerant bacterium, identified as Pediococcus acidilactici, was isolated which exhibited maximum 79 % decolorization, 85 % COD, and 94 % BOD reduction at 45 °C using 0.1 %, glucose; 0.1 %, peptone; 0.05 %, MgSO4; 0.05 %, K2HPO4; pH 6.0 within 24 h under static condition. The ability of this strain to decolorize melanoidin at minimum carbon and nitrogen supplementation warrants its possible application for effluent treatment at industrial level. In addition, it is first instance when melanoidin decolorization was reported by P. acidilactici. This study could be an approach towards control of environmental pollution and health hazards of people in and around the effluent distillery unit.  相似文献   

13.
In order to investigate the treatment performance and microorganism mechanism of IVCW for domestic wastewater in central of China, two parallel pilot-scale IVCW systems were built to evaluate purification efficiencies, microbial community structure and enzyme activities. The results showed that mean removal efficiencies were 81.03 % for COD, 51.66 % for total nitrogen (TN), 42.50 % for NH4 +-N, and 68.01 % for TP. Significant positive correlations between nitrate reductase activities and TN and NH4 +-N removal efficiencies, along with a significant correlation between substrate enzyme activity and operation time, were observed. Redundancy analysis demonstrated gram-negative bacteria were mainly responsible for urease and phosphatase activities, and also played a major role in dehydrogenase and nitrate reductase activities. Meanwhile, anaerobic bacteria, gram-negative bacteria, and saturated FA groups, gram-positive bacteria exhibited good correlations with the removal of COD (p?=?0.388), N (p?=?0.236), and TP (p?=?0.074), respectively. The IVCW system can be used to treat domestic wastewater effectively.  相似文献   

14.
固硫灰渣深度处理焦化废水的实验研究   总被引:1,自引:1,他引:0  
选用同硫灰渣深度处理经生化处理后焦化废水,采用分光光度计法评价焦化废水的处理效果,采用XRD、XRF、SEM和IR等分析材料的成分、结构和微观形貌等.结果表明,固硫灰渣用量60 g/L、吸附时间15 min,焦化废水的脱色率可达94.22%,COD从原水的76.01 mg/L降低到处理后的5.76 mg/L,NH+4-...  相似文献   

15.
采用超声波-膜生物法(MBR)联合处理垃圾渗滤液,探讨了超声波辐射时间和MBR的水力负荷对COD、NH3-N和TP去除的影响。结果表明,(1)超声波单独处理时,超声波辐射时间在30~90 s时,COD、NH3-N最大增加率分别34.31%、3.36%,而对TP的去除没有影响;(2)超声波-膜生物(MBR)联合处理时,超声波辐射时间为300 s,MBR的水力负荷为6.4 L/(m2.d)时,COD、NH3-N和TP的最佳去除率分别为92.20%、80.10%和91.12%;MBR的水力负荷为12.8 L/(m2.d),超声波辐射时间在5~20 min时,COD、NH3-N的最佳去除率分别为92.34%、79.93%,TP的浓度低于0.2 mg/L;MBR反应时间为7 h,超声波辐射时间为5~20 min,与未进行超声波辐射处理(超声波辐射时间为0 min)相比,COD、NH3-N的去除率增加了11.37%、15.26%;超声波预处理有助于提高后续MBR对COD、NH3-N的去除作用。  相似文献   

16.
改进型波形潜流人工湿地处理猪场废水   总被引:1,自引:0,他引:1  
提出了一种改进型波形潜流人工湿地(improved wavy subsurface flow constructed wetland,IW-SFCW)并研究了该湿地系统在5个水力停留时间(hydraulic retention time,HRT)(2、3、4、6和8 d)下对猪场废水的处理效果。结果表明,该湿地系统对猪场废水中各污染物有较好的去除效果。在水力停留时间为4 d,进水COD、TN、NH4+-N和TP浓度分别为511、120、110和10 mg/L左右时,该湿地系统对COD、TN、NH4+-N和TP的去除率分别为86.0%、54.4%、70.1%和91.6%。此外,该湿地系统对废水中COD、TP的去除效率随水力停留时间的延长逐渐提高,在HRT=8 d时去除效果最好,去除率分别达到92.7%和96.8%;但对TN、NH4+-N的去除率却随水力停留时间的延长出现先上升后下降的趋势,在HRT=4 d时去除率最高,分别为54.4%和70.1%。  相似文献   

17.
实验基于企业污水站的改造工程,研究了MBR对玉米深加工废水的处理效果并对工艺运行参数优化提出建议.结果表明,该工艺对COD的去除率可以达到90%以上,出水稳定在26 mg/L左右;出水NH4-N达到1 mg/L以下;TN去除率达到70%以上,出水TN达到10 mg/L以下,出水完全达到排放标准.通过4种工况的比较,说明在污泥浓度8 g/L左右,曝气池内DO在3 mg/L左右,MBR内DO>4 mg/L,好氧段停留时间13.5 h,并保证3h以上的缺氧段水力停留段时间的条件下,A/O+ MBR工艺可以有效去除玉米深加工废水中的污染物.  相似文献   

18.
Degradation of total phenol (TPh) and organic matter, (expressed as total organic carbon TOC), of a simulated olive mill wastewater was evaluated by the Fenton oxidation process under batch and continuous mode conditions. A mixture of six phenolic acids usually found in these agro-industrial wastewaters was used for this purpose. The study focused on the optimization of key operational parameters of the Fenton process in a batch reactor, namely Fe2+ dosage, hydrogen peroxide concentration, pH, and reaction temperature. On the assessment of the process efficiency, > 99% of TPh and > 56% of TOC removal were attained when [Fe2+] = 100 ppm, [H2O2] = 2.0 g/L, T = 30 °C, and initial pH = 5.0, after 300 min of reaction. Under those operational conditions, experiments on a continuous stirred-tank reactor (CSTR) were performed for different space-time values (τ). TOC and TPh removals of 47.5 and 96.9%, respectively, were reached at steady-state (for τ = 120 min). High removal of COD (> 75%) and BOD5 (> 70%) was achieved for both batch and CSTR optimum conditions; analysis of the BOD5/COD ratio also revealed an increase in the effluent’s biodegradability. Despite the high removal of lumped parameters, the treated effluent did not met the Portuguese legal limits for direct discharge of wastewaters into water bodies, which indicates that coupled chemical-biological process may be the best solution for real olive mill wastewater treatment.  相似文献   

19.
活性污泥与生物膜复合工艺处理石化废水的研究   总被引:1,自引:0,他引:1  
实验研究了活性污泥与生物膜复合工艺(HP)对石化废水的处理效果,并与活性污泥工艺(ASP)进行对比研究.结果表明,HP对石化废水中COD的去除效果略好于ASP,而对NH3-N的去除效果明显优于ASP.另外,两种工艺对硫化物和油的去除效果类似.提高进水负荷时,HP表现出较强的耐冲击负荷能力.以2L/h连续运行时,石化废水...  相似文献   

20.
ABSTRACT

In this study, granular activated carbon (GAC) was used as an adsorbent for biogas desulfurization. Biogas containing 932–2,350 ppm of H2S was collected from an anaerobic digester to treat the wastewater from a dairy farm with about 200 cows. An adsorption test was performed by introducing the biogas to a column that was packed with approximately 50 L of commercial GAC. The operation ceased if the effluent gas had an H2S concentration of over 100 ppm. The GAC was replaced by a given weight of new GAC in a subsequent test. According to the results, for H2S concentrations in the range of 932–1,560 ppm (average±SD = 1,260 ± 256 ppm), 1 kg of the GAC yielded biogas treatment capacities of 568 ± 112 m3 and H2S adsorption capacities of 979 ± 235 g. For the higher influent H2S concentrations of 2,110 ± 219 ppm, the biogas treatment and H2S-adsorption capacities decreased to 229 ± 18 m3 and 668 ± 47 g, respectively. An estimation indicated a requisite cost of US$16.5 for the purification of 1,000 m3 of biogas containing 2,110 ppm of H2S. This cost is approximately 5% of US$330, the value of 1,000 m3 of biogas.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏