首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到19条相似文献,搜索用时 312 毫秒
1.
三级生物膜深度处理腈纶废水生化出水的脱氮研究   总被引:3,自引:3,他引:0  
针对腈纶废水生化出水用传统脱氮工艺深度脱氮时碳源不足的问题,采用三级生物膜反应器作为深度处理装置,研究了反应器的启动及进水pH、水力停留时间(HRT)、进水氨氮(NH4+-N)浓度对NH4+-N去除率的影响并确定其最佳运行条件及最佳条件下总氮(TN)的去除效果.结果表明,在HRT为24 h,进水pH为7.8~8.0条件下反应器对NH4+-N和TN的去除效果最佳,平均去除率分别为94.6%和53%;且进水NH4+-N浓度对其去除效果没有明显影响;反应器在不投加有机碳源情况下,对TN有明显去除效果,平均去除率53%,最高去除率达66%,表明三级生物膜反应器深度处理腈纶废水时脱氮效果明显.  相似文献   

2.
利用UAFB反应器富集培养了厌氧氨氧化细菌,并在此基础上考察水力停留时间(HRT)对厌氧氨氧化系统处理效果的影响。结果表明:HRT对厌氧氨氧化系统影响较大,当HRT为4 h时,系统出水NH4+-N、NO2--N去除率降至65%~60%,出水浓度则分别为15 mg/L、20 mg/L,表明过短HRT会导致含氮污染物去除不完全;HRT为6 h时,系统中NH4+-N去除率均在95%以上,出水NH4+-N≈1 mg/L。系统中NO2--N去除率均在92%以上,出水NO2--N≤5 mg/L;当HRT继续延长至10 h,去除效果无明显变化,出水NH4+-N≈1 mg/L,NO2--N≤5 mg/L,NO3--N平均5.6 mg/L。因此,在该研究中HRT为6 h效果最佳,总氮容积去除负荷为0.57 kg/(m3·d),厌氧氨氧化(ANAMMOX)反应器氨氮去除量、亚硝态氮去除量和硝态氮生成量之比为1∶1.19∶0.39。  相似文献   

3.
利用复合膜生物反应器工艺研究填埋场垃圾渗滤脱氨运行环境,在常温环境下运行结果表明:HSMBR反应器大量截留并使世代时间长的硝化菌在最短的时间富集成为优势菌种,对垃圾渗滤液中NH4+-N具有高效的去除效率;工艺运行参数在硝化池HRT为50~60 h环境下,NH4+-N的MLSS负荷为0.06~0.09 g/(g·d),DO质量浓度为3.0~3.5 mg/L,硝化池pH值在7.50~7.80,脱除NH4+-N的效果较好,去除率在95%~98%.  相似文献   

4.
设计了一种新型三相内循环生物流化反应器,对其硝化特性进行了试验研究.试验结果表明,水力停留时间(HRT)为4 h、溶解氧(DO)质量浓度为3 mg/L、温度(t)在25~30℃,单位CODCr有机负荷为4 kg/(m3·d)左右时,氨氮(NH4+-N)去除效果最佳,去除率可达80%以上.  相似文献   

5.
微污染原水的生物流化床预处理技术试验研究   总被引:7,自引:0,他引:7  
于鑫  李旭东 《环境工程》1999,17(5):13-16
以二相颗粒活性炭生物流化床(FBBR)为反应器,对以有机物和NH4+N为主要污染物的某大城市内河原水进行了预处理试验研究,在HRT12~18min,气水比20~25∶1,回流比3~4∶1的条件下FBBR对CODCr、NH4+N、NO2-N、浊度、色度的去除率分别为4132%、100%、97%~100%、6880%、30%~50%,而且对NH4+N和NO2+N有较强的抗冲击负荷能力。  相似文献   

6.
溶解氧对膜生物反应器处理高氨氮废水的影响   总被引:4,自引:0,他引:4  
采用膜生物反应器(MBR)处理高氨氮有机废水,探讨了溶解氧(DO)对有机物、氨氮、总氮等去除效果的影响。当进水COD1500mg/L,NH4+-N150mg/L,TP为15mg/L,pH7.5~8.0,MLSS控制在6000~7000mg/L,DO在0.5~4mg/L时对COD的去除效果没有明显影响,都可高达95%;在DO为4.0和2.0mg/L时对NH4+-N的去除率都很高,最高可达99.17%,在DO为0.5mg/L时明显降低,最低降至48.30%。在DO2.0mg/L时,取得了较好的同步硝化反硝化效果,COD、NH4+-N、TN去除率分别高达97%、97%、68%。MBR中硝化反应的比氨氮消耗速率与氨氮浓度成零级反应动力学,比氨氮硝化速率为0.0979/d,比常规处理系统中的污泥硝化活性高。  相似文献   

7.
城市生活垃圾渗滤液的ASBR-SBR生物脱氮研究   总被引:1,自引:0,他引:1  
将ASBR和SBR反应器组合起来,形成一种序批式操作的垃圾渗滤液处理工艺,两反应器的运行周期均为12h。将原水加入ASBR中进行厌氧消化,研究了废水在28.8h~72h四种不同水力停留时间(HRT)下的处理效果,结果表明,将ASBR的HRT控制在36h,在保持41.2%COD去除率的同时,出水BOD5/COD及BOD5/NH4+-N分别为0.41和4.6,对有机物和氮的后续好氧生物去除较为有利。以HRT为36h方式运行的ASBR出水为进水,研究了每周期进水量占反应器混合液比例R分别为0.67、0.50、0.33和0.17情况下,SBR去除有机物及脱氮的效果,结果表明,对于pH较低的垃圾渗滤液,R≤0.5时,反应器内反硝化反应产生的碱度和硝化反应消耗的碱度较为平衡,pH稳定在脱氮微生物适宜的范围内,脱氮及去除有机物的效果较好,对COD去除率在88%~90%,NH4+-N去除率在96%~98%,TN去除率在55%~84%,其中TN去除率与R存在较好的线性相关性,TN去除率随着R的减小而逐步提高.  相似文献   

8.
HRT对瓷粒BAF处理生活污水效能的影响   总被引:3,自引:1,他引:2  
通过实验室模型试验研究了瓷粒曝气生物滤池处理生活污水的效能,分析了在气水比一定的条件下,水力停留时间(HRT)变化对曝气生物滤池处理效能及运行特性的影响规律。考察了不同HRT运行下,COD、NH4+-N、NO2--N、NO3--N、TN、SS等指标的变化,结果表明,当进水COD为280~320mg/L,气水比为3:1,HRT为10h的条件下,处理效果最好,其中COD、NH4+-N、TN、SS的平均去除率分别为92.6%、97.8%、34.7%、84.2%。当HRT逐渐降低时,以上指标的去除效果都有所下降,但去除效能的下降与HRT的降低不呈线性关系。当HRT降至3h,去除效能有一定程度的上升,COD、NH4+-N、TN、SS的去除率有所增加。  相似文献   

9.
为提高煤矿生活污水脱氮效果并优化反应方式,采用限氧曝气生物膜反应器进行试验研究,分析了污染物去除效果和主要影响因素。结果表明:在第一反应室DO为1.5~2 mg/L、第二反应室DO为1~1.5 mg/L、HRT为3.13 h、ρ(COD)=69.8~85.2 mg/L、ρ(NH4+-N)=14. 6~17.9 mg/L、ρ(TN)=17.3~21.2 mg/L的进水条件下,反应器出水COD、NH4+-N、TN最大质量浓度分别为18.3 mg/L、0.23 mg/L和8.92 mg/L,平均去除率分别为80.8%、99.3%和59.3%,同步硝化反硝化效率(SND率)为45.4%~56.5%;在2.78 h≤HRT≤4.17 h范围内,反应器出水COD和NH4+-N浓度达到GB 3838—2002Ⅲ类标准要求,出水ρ(TN)10 mg/L且SND率达到52%。  相似文献   

10.
对气提反应器处理生活污水进行了试验研究,探讨了生物膜的形成和水力停留时间及曝气量时中低浓度生活污水处理效果的影响.结果表明:最优条件是在HRT为6h,曝气量为0.6 m3/h,进水COD和NH4+-N质量浓度分剐为240.2~298.7 mg/L和29.1~68.9 mg/L条件下,平均COD去除率为83%,NH4+-N去除率为95.1%.  相似文献   

11.
A self-design bioreactor system employing a fixed bed operation process with immobilized Bacillus subtilis AYC beads for NH4 +-N removal from slightly polluted water was proposed. Polyvinyl alcohol and Na-alginate were used as a gel matrix to entrap Bacillus subtilis AYC to form the immobilized beads. The NH4 +-N removal process was studied in a intermittent operation mode to examine the start-up and steady state behaviors of the immobilized AYC in the reactor. The results indicated that the reactor was in the start-up state during the first week. NH4 +-N began to be steadily removal since the second week, and the nitrogen removal rate was between 84.61% and 96.19% when the hydraulic retention time (HRT) was 30 min. To apply Bacillus subtilis AYC to develop a practical nitrogen removal system and further understand its nitrogen removal ability, the bioreactor was continuously operated under different experimental perameters. The results showed that under the optimum conditions of an HRT of 20 min and DO of 3.77–5.80 mg/L, the NH4 +-N removal rate reached 99.55%. The NH4 +-N removal rate increased as the C/N ratio increased. However, a high C/N may cause a high residual carbon level in the effluent, therefore, the most suitable C/N ratio was 10. In addition, the results showed that the bioreactor system could remove many types of nitrogen such as NH4 +-N, NO3??-N and organic-N, and had a good performance for inorganic nitrogen removal from sewage.  相似文献   

12.
A membrane aerated biofilm reactor is a promising technology for wastewater treatment. In this study, a carbon-membrane aerated biofilm reactor (CMABR) has been developed, to remove carbon organics and nitrogen simultaneously from one reactor. The results showed that CMABR has a high chemical oxygen demand (COD) and nitrogen removal efficiency, as it is operated with a hydraulic retention time (HRT) of 20 h, and it also showed a perfect performance, even if the HRT was shortened to 12 h. In this period, the removal efficiencies of COD, ammonia nitrogen (NH4^+-N), and total nitrogen (TN) reached 86%, 94%, and 84%, respectively. However, the removal efficiencies of NH4^+-N and TN declined rapidly as the HRT was shortened to 8 h. This is because of the excessive growth of biomass on the nonwoven fiber and very high organic loading rate. The fluorescence in situ hybridization (FISH) analysis indicated that the ammonia oxidizing bacteria (AOB) were mainly distributed in the inner layer of the biofilm. The coexistence of AOB and eubacteria in one biofilm can enhance the simultaneous removal of COD and nitrogen.  相似文献   

13.
研究了ANAMMOX耦合异养反硝化反应器的启动过程,考察了苯酚浓度对耦合反应器脱氮性能的影响.接种2L(占反应器有效容积的20%)挥发性悬浮固体(MLVSS)为6000mg/L的ANAMMOX颗粒污泥,在pH7.8、温度为25℃、HRT为1.5h的条件下经过86d的培养,ANAMMOX耦合异养反硝化启动成功.实验结果表明,在稳定运行阶段,NH4+-N、NO2--N和TN平均去除率分别为85.4%、86.1%和79.9%,TN平均容积负荷和TN平均去除负荷分别为2.63,2.10kg/(m3·d);ANAMMOX颗粒污泥外面包裹着苯酚反硝化菌;系统内异养反硝化与ANAMMOX存在协同和竞争关系.当苯酚浓度≥0.3mmol/L时,ANAMMOX菌的活性受到很大抑制,苯酚浓度的升高加剧了苯酚反硝化菌与ANAMMOX菌之间的竞争;从脱氮效果及系统稳定两方面综合考虑,当苯酚浓度为0.2mmol/L时,耦合效果最好,消耗的NH4+-N、NO2--N与生成的NO3--N之比为1:1.52:0.11.  相似文献   

14.
生物膜反应器厌氧氨氧化脱氮效能研究   总被引:7,自引:0,他引:7  
利用厌氧氨氧化生物膜反应器,分别研究提高基质浓度和缩短水力停留时间(HRT)对提高反应器总氮容积去除负荷的影响。实验之前总氮容积去除负荷达到2.11kgN(/m·3d),总氮去除率为87.9%。以提高基质浓度的方式经过50d的培养,总氮容积去除负荷稳定在4.0kgN(/m·3d),进水总氮浓度从300mg/L逐渐提高到700mg/L,NH4+-N、NO2--N出水浓度分别达到70mg/L和100mg/L;以缩短HRT的方式经过55d的培养,总氮容积去除负荷达到7.0kgN(/m·3d),HRT由3h缩短至0.67h,NH4+-N、NO2--N出水浓度分别达到40mg/L和60mg/L。实验结果表明随着进水基质浓度的增加水中游离氨和亚硝酸的浓度随之增加,从而抑制厌氧氨氧化菌活性,不利于反应器脱氮效能的提高。在相同总氮容积负荷下缩短HRT有利于厌氧氨氧化细菌的富集,但过短的HRT容易导致微生物流失。  相似文献   

15.
内循环移动床生物膜反应器的研究与应用   总被引:2,自引:0,他引:2  
对传统移动床生物膜反应器进行改进,开发了内循环移动床生物膜反应器,通过处理模拟生活污水的研究,考察了反应器去除有机物和脱氮的能力。结果表明,在填料投加率为35%、进水COD为200~800mg/L、HRT为6h、有机负荷为0.8~3.2kg/(m.3d)的条件下,系统COD的去除率在89%以上;同时反应器具有良好的同步硝化反硝化脱氮能力,在DO为2.0mg/L、C/N为25、HRT为6h的条件下,NH4-N和TN的平均去除率分别可以达到98%和93%。另外,内循环移动床生物膜反应器与移动床生物膜反应器的对比实验结果表明,前者对COD和氮的去除效果都优于后者。  相似文献   

16.
焦化废水厌氧氨氧化生物脱氮的研究   总被引:3,自引:1,他引:3       下载免费PDF全文
采用厌氧氨氧化(ANAMMOX)工艺处理焦化废水,在厌氧34℃、pH值7.5~8.5,HRT为33h的条件下,经过115d成功启动厌氧氨氧化反应器.当进水NH4+-N、NO2--N浓度分别为80、90mg/L左右时, TN负荷可达160mg/(L·d),系统NH4+-N和NO2--N的去除率最高分别达86%和98%,TN去除率可达75%. GC-MS分析结果表明,酚类是焦化废水中较易被生物利用的有机物,ANAMMOX过程对好氧短程硝化工艺出水残余低浓度酚类有机物有进一步去除作用.  相似文献   

17.
采用混合型(火山岩和陶瓷环)填料生物接触氧化工艺处理实际生活污水,研究了混合型填料挂膜情况,不同HRT、DO和进水COD浓度对水质净化效果的影响。实验结果表明:混合型填料挂膜效果好,15 d后反应器达到稳定状态,对COD的去除率达到75%以上;在水温为20~32℃,HRT为12 h,DO为5~6 mg/L的条件下,对COD、氨氮、TN和TP的平均去除率分别达到了75.8%、71.8%、45.9%和35.7%;当进水COD浓度为100~400 mg/L时,各个指标的去除率随着COD浓度的升高而升高,可见进水COD浓度会对污水净化效果产生影响。  相似文献   

18.
响应面法优化CANON工艺处理猪场沼液脱氮性能研究   总被引:1,自引:2,他引:1       下载免费PDF全文
王子凌  信欣  刘琴  杨豪  曹惜霜 《环境科学研究》2020,33(10):2326-2334
为了得到全程自养脱氮(completely autotrophic nitrogen removal over nitrite,CANON)工艺处理猪场沼液脱氮性能的最佳工艺条件,以处理实际猪场沼液的连续流CANON工艺为研究对象,采用BBD响应面法优化其关键运行参数,探究了HRT(水力停留时间)、温度和进水ρ(NH4+-N)各因素的交互作用.结果表明:①HRT、温度和进水ρ(NH4+-N)对反应器脱氮效率均有显著影响,且数学模型拟合度良好,各因素对TN、NH4+-N去除率的影响程度由强到弱依次为进水ρ(NH4+-N)> HRT >温度.②通过BBD响应面法获得最佳脱氮条件为HRT 1.35 d、温度34.4℃、进水ρ(NH4+-N)415 mg/L.在接近响应面优化后的条件下进行验证试验,得到出水ρ(NH4+-N)平均值为74.68 mg/L,NH4+-N去除率为83.05%;出水ρ(TN)平均值为108.28 mg/L,TN去除率为73.91%,与模型预测值较接近.研究显示,BBD响应面法能在较少的试验次数下检验影响因素之间的交互作用,可科学地优化CANON工艺处理猪场沼液的脱氮性能.   相似文献   

19.
To examine treatment and remediation of a wastewater lagoon with poor biodegradability, a typical wastewater lagoon in Tianjin, China, was treated and remedied using microelectrolysis and modified demand aeration tank (DAT)/intermittent aeration tank (IAT) methods. After pretreatment by microelectrolysis, the removal e ciency of chemical oxygen demand (COD) was up to 64.6% and the ratio of BOC/COD in the e uent increased from 0.013 to 0.609. The removal rates of CODCr and NH+4 -N were a ected by sludge backflow rate, mixed liquor suspended solids (MLSS), and hydraulic retention time (HRT) in the modified DAT/IAT reactor. The highest removal rates of CODCr and NH+4 -N were up to 78.9% and 62.6%, respectively, when the sludge backflow rate was 38.0 mL/min, the total HRT was 8.0 hr and MLSS was 4088.0 mg/L. In this case, some protozoa and metazoa were observed in activated sludge and biofilm carriers. Most of chrominance was removed by microelectrolysis treatment, while the modified DAT/IAT methods were more e ective for CODCr and NH+4 -N removal.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号